{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:22:51Z","timestamp":1740136971336,"version":"3.37.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,7,8]],"date-time":"2021-07-08T00:00:00Z","timestamp":1625702400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,8]],"date-time":"2021-07-08T00:00:00Z","timestamp":1625702400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100010731","name":"Faculty of Medicine, Chiang Mai University","doi-asserted-by":"publisher","award":["ORT-2561-05759"],"award-info":[{"award-number":["ORT-2561-05759"]}],"id":[{"id":"10.13039\/501100010731","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"published-print":{"date-parts":[[2022,7]]},"DOI":"10.1007\/s00590-021-03072-3","type":"journal-article","created":{"date-parts":[[2021,7,8]],"date-time":"2021-07-08T14:03:59Z","timestamp":1625753039000},"page":"991-1000","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Reverse distal femoral locking compression plate (DF-LCP), does it fit and how to fit on Asian\u2019s proximal femurs? A cadaveric study"],"prefix":"10.1007","volume":"32","author":[{"given":"V.","family":"Apivatthakakul","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8374-9540","authenticated-orcid":false,"given":"T.","family":"Apivatthakakul","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,7,8]]},"reference":[{"issue":"7","key":"3072_CR1","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1007\/s00264-014-2306-1","volume":"38","author":"RU Haq","year":"2014","unstructured":"Haq RU, Manhas V, Pankaj A, Srivastava A, Dhammi IK, Jain AK (2014) Proximal femoral nails compared with reverse distal femoral locking plates in intertrochanteric fractures with a compromised lateral wall; a randomised controlled trial. Int Orthop 38(7):1443\u20131449","journal-title":"Int Orthop"},{"issue":"8","key":"3072_CR2","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.otsr.2014.07.023","volume":"100","author":"KL Ma","year":"2014","unstructured":"Ma KL, Wang X, Luan FJ, Xu HT, Fang Y, Min J et al (2014) Proximal femoral nails antirotation, gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: a meta-analysis. Orthop Traumatol Surg Res 100(8):859\u2013866","journal-title":"Orthop Traumatol Surg Res"},{"issue":"2","key":"3072_CR3","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1097\/BOT.0b013e3181e31ccc","volume":"25","author":"PJ Glassner","year":"2011","unstructured":"Glassner PJ, Tejwani NC (2011) Failure of proximal femoral locking compression plate: a case series. J Orthop Trauma 25(2):76\u201383","journal-title":"J Orthop Trauma"},{"issue":"10","key":"3072_CR4","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1007\/s00402-010-1074-7","volume":"130","author":"K Wieser","year":"2010","unstructured":"Wieser K, Babst R (2010) Fixation failure of the LCP proximal femoral plate 4.5\/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur. Arch Orthop Trauma Surg 130(10):1281\u20131287","journal-title":"Arch Orthop Trauma Surg"},{"issue":"27","key":"3072_CR5","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1097\/BOT.0b013e318251930d","volume":"2013","author":"PN Streubel","year":"2013","unstructured":"Streubel PN, Moustoukas MJ, Obremskey WT (2013) Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures. J Orthop Trauma 2013(27):22\u20138","journal-title":"J Orthop Trauma"},{"issue":"8","key":"3072_CR6","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1007\/s00590-017-1981-1","volume":"27","author":"S Hodel","year":"2017","unstructured":"Hodel S, Beeres FJP, Babst R, Link BC (2017) Complications following proximal femoral locking compression plating in unstable proximal femur fractures: medium-term follow-up. Eur J Orthop Surg Traumatol 27(8):1117\u20131124","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"3072_CR7","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.jcot.2016.11.005","volume":"8","author":"MD Shah","year":"2017","unstructured":"Shah MD, Kapoor CS, Soni RJ, Patwa JJ, Golwala PP (2017) Evaluation of outcome of proximal femur locking compression plate (PFLCP) in unstable proximal femur fractures. J Clin Orthop Trauma 8(4):308\u2013312","journal-title":"J Clin Orthop Trauma"},{"key":"3072_CR8","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1097\/BOT.0b013e3181e31ccc","volume":"25","author":"PJ Glassner","year":"2011","unstructured":"Glassner PJ, MaNCT MD (2011) Failure of proximal femoral locking compression plate: a case series. J Clin Orthop Trauma 25:76\u201383","journal-title":"J Clin Orthop Trauma"},{"issue":"6","key":"3072_CR9","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1016\/j.injury.2013.02.020","volume":"44","author":"C Wirtz","year":"2013","unstructured":"Wirtz C, Abbassi F, Evangelopoulos DS, Kohl S, Siebenrock KA, Kruger A (2013) High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate. Injury 44(6):751\u2013756","journal-title":"Injury"},{"issue":"5","key":"3072_CR10","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1097\/01.bot.0000435629.86640.6f","volume":"28","author":"B Johnson","year":"2014","unstructured":"Johnson B, Stevenson J, Chamma R, Patel A, Rhee SJ, Lever C et al (2014) Short-term follow-up of pertrochanteric fractures treated using the proximal femoral locking plate. J Orthop Trauma 28(5):283\u2013287","journal-title":"J Orthop Trauma"},{"issue":"9","key":"3072_CR11","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1097\/BOT.0000000000000602","volume":"30","author":"CA Collinge","year":"2016","unstructured":"Collinge CA, Hymes R, Archdeacon M, Streubel P, Obremskey W, Weber T et al (2016) Unstable proximal femur fractures treated with proximal femoral locking plates: a retrospective, multicenter study of 111 cases. J Orthop Trauma 30(9):489\u2013495","journal-title":"J Orthop Trauma"},{"issue":"1","key":"3072_CR12","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1097\/BOT.0b013e318251930d","volume":"27","author":"PN Streubel","year":"2013","unstructured":"Streubel PN, Moustoukas MJ, Obremskey WT (2013) Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures. J Orthop Trauma 27(1):22\u201328","journal-title":"J Orthop Trauma"},{"issue":"2","key":"3072_CR13","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.injury.2006.08.052","volume":"38","author":"JR Pryce Lewis","year":"2007","unstructured":"Pryce Lewis JR, Ashcroft GP (2007) Reverse LISS plating for proximal segmental femoral fractures in the polytrauma patient: a case report. Injury 38(2):235\u2013239","journal-title":"Injury"},{"issue":"4","key":"3072_CR14","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.injury.2009.05.033","volume":"41","author":"YP Acklin","year":"2010","unstructured":"Acklin YP, Bereiter H, Sommer C (2010) Reversed LISS-DF in selected cases of complex proximal femur fractures. Injury 41(4):427\u2013429","journal-title":"Injury"},{"issue":"8","key":"3072_CR15","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/j.injury.2010.03.028","volume":"41","author":"CH Ma","year":"2010","unstructured":"Ma CH, Tu YK, Yu SW, Yen CY, Yeh JH, Wu CH (2010) Reverse LISS plates for unstable proximal femoral fractures. Injury 41(8):827\u2013833","journal-title":"Injury"},{"key":"3072_CR16","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1186\/1471-2474-11-166","volume":"11","author":"CQ Zhang","year":"2010","unstructured":"Zhang CQ, Sun Y, Jin DX, Yao C, Chen SB, Zeng BF (2010) Reverse LISS plating for intertrochanteric hip fractures in elderly patients. BMC Musculoskelet Disord 11:166","journal-title":"BMC Musculoskelet Disord"},{"issue":"5","key":"3072_CR17","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.otsr.2010.12.007","volume":"97","author":"M Ehlinger","year":"2011","unstructured":"Ehlinger M, Brinkert D, Besse J, Adam P, Arlettaz Y, Bonnomet F (2011) Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation. Orthop Traumatol Surg Res 97(5):560\u2013564","journal-title":"Orthop Traumatol Surg Res"},{"issue":"3","key":"3072_CR18","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1097\/BOT.0b013e318225f793","volume":"26","author":"F Zhou","year":"2012","unstructured":"Zhou F, Zhang ZS, Yang H, Tian Y, Ji HQ, Guo Y et al (2012) Less invasive stabilization system (LISS) versus proximal femoral nail anti-rotation (PFNA) in treating proximal femoral fractures: a prospective randomized study. J Orthop Trauma 26(3):155\u2013162","journal-title":"J Orthop Trauma"},{"issue":"5","key":"3072_CR19","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.cjtee.2015.11.002","volume":"18","author":"P Gogna","year":"2015","unstructured":"Gogna P, Mukhopadhyay R, Singh A, Devgan A, Arora S, Batra A et al (2015) Contralateral reversed distal femoral locking plate for fixation of subtrochanteric femoral fractures. Chin J Traumatol 18(5):279\u2013283","journal-title":"Chin J Traumatol"},{"issue":"6","key":"3072_CR20","doi-asserted-by":"publisher","first-page":"e467","DOI":"10.3928\/01477447-20150603-53","volume":"38","author":"M Russo","year":"2015","unstructured":"Russo M, Malekzadeh AS, Hampton C, Hymes R, Schwartzbach C, Schulman J (2015) Reversed contralateral liss plate for vancouver b1 periprosthetic femoral shaft fractures. Orthopedics 38(6):e467\u2013e472","journal-title":"Orthopedics"},{"issue":"8","key":"3072_CR21","doi-asserted-by":"publisher","first-page":"1709","DOI":"10.1007\/s00264-015-3002-5","volume":"40","author":"R Vaishya","year":"2016","unstructured":"Vaishya R, Agarwal AK, Gupta N, Vijay V (2016) Reversed distal femoral locking plate for failed proximal femoral nail with non-union of proximal femoral fractures. Int Orthop 40(8):1709\u20131715","journal-title":"Int Orthop"},{"issue":"10","key":"3072_CR22","doi-asserted-by":"publisher","first-page":"2161","DOI":"10.1016\/j.injury.2016.07.015","volume":"47","author":"SJ Lin","year":"2016","unstructured":"Lin SJ, Huang KC, Chuang PY, Lee CY, Huang TW, Lee MS et al (2016) The outcome of unstable proximal femoral fracture treated with reverse LISS plates. Injury 47(10):2161\u20132168","journal-title":"Injury"},{"issue":"1","key":"3072_CR23","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1007\/s00402-011-1375-5","volume":"132","author":"JH Hwang","year":"2012","unstructured":"Hwang JH, Oh JK, Oh CW, Yoon YC, Choi HW (2012) Mismatch of anatomically pre-shaped locking plate on Asian femurs could lead to malalignment in the minimally invasive plating of distal femoral fractures: a cadaveric study. Arch Orthop Trauma Surg 132(1):51\u201356","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"3072_CR24","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1007\/s00264-008-0603-2","volume":"33","author":"T Apivatthakakul","year":"2009","unstructured":"Apivatthakakul T, Chiewcharntanakit S (2009) Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated. Int Orthop 33(4):1119\u20131126","journal-title":"Int Orthop"},{"key":"3072_CR25","first-page":"4124","volume":"2014","author":"C Ying","year":"2014","unstructured":"Ying C, Liu Shouyao LP, Yunting W, Jinhui W, Jianfeng T, Rongrong C (2014) Comparative biomechanical study of reversed less invasive stabilization system and proximal femoral nail antirotation for unstable intertrochanteric fractures. Chin Med J 2014:4124\u20134129","journal-title":"Chin Med J"},{"issue":"3","key":"3072_CR26","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.injury.2005.09.022","volume":"37","author":"SA Sidhom","year":"2006","unstructured":"Sidhom SA, Pinder R, Shaw DL (2006) Reverse LISS plate stabilisation of a subtrochanteric fracture of the femur in a patient with osteopetrosis: is this the answer? Injury Extra 37(3):113\u2013115","journal-title":"Injury Extra"},{"issue":"5","key":"3072_CR27","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.ijsu.2014.03.006","volume":"12","author":"G Li","year":"2014","unstructured":"Li G, Li Z, Han N, Lu Q (2014) A retrospective analysis of reversed femoral Less Invasive Stable System (LISS) for treatment of subtrochanteric femoral fracture. Int J Surg 12(5):432\u2013436","journal-title":"Int J Surg"},{"issue":"1","key":"3072_CR28","doi-asserted-by":"publisher","first-page":"68","DOI":"10.5371\/hp.2017.29.1.68","volume":"29","author":"JH Jang","year":"2017","unstructured":"Jang JH, Ahn JM, Lee HJ, Moon NH (2017) Surgical outcomes of biologic fixation for subtrochanteric fracture using locking compression plates. Hip Pelvis 29(1):68\u201376","journal-title":"Hip Pelvis"},{"issue":"3","key":"3072_CR29","doi-asserted-by":"publisher","first-page":"417","DOI":"10.18203\/issn.2455-4510.IntJResOrthop20191046","volume":"5","author":"J Singh","year":"2019","unstructured":"Singh J, Selhi HS, Gupta R, Kaur G (2019) Functional outcomes of reverse distal femoral locking plate in the extra capsular fractures of proximal femur. Int J Res Orthop 5(3):417","journal-title":"Int J Res Orthop"},{"issue":"5","key":"3072_CR30","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s00590-017-1900-5","volume":"27","author":"YS Shin","year":"2017","unstructured":"Shin YS, Han SB (2017) Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable. Eur J Orthop Surg Traumatol 27(5):623\u2013630","journal-title":"Eur J Orthop Surg Traumatol"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-021-03072-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-021-03072-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-021-03072-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,8]],"date-time":"2022-06-08T18:33:39Z","timestamp":1654713219000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-021-03072-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,8]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["3072"],"URL":"https:\/\/doi.org\/10.1007\/s00590-021-03072-3","relation":{},"ISSN":["1432-1068"],"issn-type":[{"type":"electronic","value":"1432-1068"}],"subject":[],"published":{"date-parts":[[2021,7,8]]},"assertion":[{"value":"26 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 June 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}