{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T20:29:19Z","timestamp":1746476959563,"version":"3.37.3"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"DOI":"10.1007\/s00590-022-03298-9","type":"journal-article","created":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T15:02:58Z","timestamp":1653663778000},"page":"1307-1314","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Minimum 2-year results of the second-generation CFR-PEEK locking plate on the proximal humeral fracture"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3530-6726","authenticated-orcid":false,"given":"Rony-Orijit","family":"Dey Hazra","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karol","family":"Szewczyk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Ellwein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Blach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gunnar","family":"Jensen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"K\u00fchnapfel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Lill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mara","family":"Warnhoff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,27]]},"reference":[{"key":"3298_CR1","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1016\/j.injury.2017.02.021","volume":"48","author":"CM Court-Brown","year":"2017","unstructured":"Court-Brown CM, Clement ND, Duckworth AD et al (2017) The changing epidemiology of fall-related fractures in adults. Injury 48:819\u2013824","journal-title":"Injury"},{"key":"3298_CR2","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11020408","author":"RO Dey Hazra","year":"2022","unstructured":"Dey Hazra RO, Illner J, Szewczyk K et al (2022) Age-independent clinical outcome in proximal humeral fractures: 2-year results using the example of a precontoured locking plate. J Clin Med. https:\/\/doi.org\/10.3390\/jcm11020408","journal-title":"J Clin Med"},{"key":"3298_CR3","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/00005131-200604000-00004","volume":"20","author":"RA Meier","year":"2006","unstructured":"Meier RA, Messmer P, Regazzoni P et al (2006) Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade plate. J Orthop Trauma 20:253\u2013260. https:\/\/doi.org\/10.1097\/00005131-200604000-00004","journal-title":"J Orthop Trauma"},{"key":"3298_CR4","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","volume":"21","author":"J Agudelo","year":"2007","unstructured":"Agudelo J, Sch\u00fcrmann M, Stahel P et al (2007) Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma 21:676\u2013681. https:\/\/doi.org\/10.1097\/BOT.0b013e31815bb09d","journal-title":"J Orthop Trauma"},{"key":"3298_CR5","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1007\/s00068-020-01380-7","volume":"47","author":"G Lorenz","year":"2021","unstructured":"Lorenz G, Sch\u00f6nthaler W, Huf W et al (2021) Complication rate after operative treatment of three- and four-part fractures of the proximal humerus: locking plate osteosynthesis versus proximal humeral nail. Eur J Trauma Emerg Surg 47:2055\u20132064. https:\/\/doi.org\/10.1007\/s00068-020-01380-7","journal-title":"Eur J Trauma Emerg Surg"},{"key":"3298_CR6","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1007\/s00264-020-04577-y","volume":"44","author":"J Dauwe","year":"2020","unstructured":"Dauwe J, Walters G, Holzer LA et al (2020) Failure after proximal humeral fracture osteosynthesis: a one year analysis of hospital-related healthcare cost. Int Orthop 44:1217\u20131221. https:\/\/doi.org\/10.1007\/s00264-020-04577-y","journal-title":"Int Orthop"},{"key":"3298_CR7","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1080\/17453674.2018.1450207","volume":"89","author":"MR Kristensen","year":"2018","unstructured":"Kristensen MR, Rasmussen JV, Elmengaard B et al (2018) High risk for revision after shoulder arthroplasty for failed osteosynthesis of proximal humeral fractures: a matched pair analysis of 285 cases from the Danish Shoulder Arthroplasty Registry. Acta Orthop 89:345\u2013350. https:\/\/doi.org\/10.1080\/17453674.2018.1450207","journal-title":"Acta Orthop"},{"key":"3298_CR8","doi-asserted-by":"publisher","first-page":"e236","DOI":"10.1097\/BOT.0000000000000858","volume":"31","author":"E Sebastia-Forcada","year":"2017","unstructured":"Sebastia-Forcada E, Lizaur-Utrilla A, Cebrian-Gomez R et al (2017) Outcomes of reverse total shoulder arthroplasty for proximal humeral fractures: primary arthroplasty versus secondary arthroplasty after failed proximal humeral locking plate fixation. J Orthop Trauma 31:e236\u2013e240. https:\/\/doi.org\/10.1097\/BOT.0000000000000858","journal-title":"J Orthop Trauma"},{"key":"3298_CR9","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1097\/BOT.0b013e318169ef2a","volume":"22","author":"KA Egol","year":"2008","unstructured":"Egol KA, Ong CC, Walsh M et al (2008) Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates. J Orthop Trauma 22:159\u2013164. https:\/\/doi.org\/10.1097\/BOT.0b013e318169ef2a","journal-title":"J Orthop Trauma"},{"key":"3298_CR10","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.1002\/jor.22115","volume":"30","author":"I Nakahara","year":"2012","unstructured":"Nakahara I, Takao M, Goto T et al (2012) Interfacial shear strength of bioactive-coated carbon fiber reinforced polyetheretherketone after in vivo implantation. J Orthop Res Off Publ Orthop Res Soc 30:1618\u20131625. https:\/\/doi.org\/10.1002\/jor.22115","journal-title":"J Orthop Res Off Publ Orthop Res Soc"},{"key":"3298_CR11","doi-asserted-by":"publisher","DOI":"10.1055\/a-1333-3951","author":"R-O Dey Hazra","year":"2021","unstructured":"Dey Hazra R-O, Blach RM, Ellwein A et al (2021) Latest trends in the current treatment of proximal humeral fractures\u2014an analysis of 1162 cases at a level-1 trauma centre with a special focus on shoulder surgery. Z Orthop Unfall. https:\/\/doi.org\/10.1055\/a-1333-3951","journal-title":"Z Orthop Unfall"},{"key":"3298_CR12","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s10195-017-0457-8","volume":"18","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Huber M, Grabowski S, Ellwein A (2017) Failure and revision rates of proximal humeral fracture treatment with the use of a standardized treatment algorithm at a level-1 trauma center. J Orthop Traumatol 18:265\u2013274. https:\/\/doi.org\/10.1007\/s10195-017-0457-8","journal-title":"J Orthop Traumatol"},{"key":"3298_CR13","doi-asserted-by":"publisher","first-page":"440","DOI":"10.5435\/JAAOS-21-07-440","volume":"21","author":"EM Feerick","year":"2013","unstructured":"Feerick EM, McGarry JP (2013) Using computational simulation for analysis and development of next-generation orthopaedic devices. J Am Acad Orthop Surg 21:440\u2013442. https:\/\/doi.org\/10.5435\/JAAOS-21-07-440","journal-title":"J Am Acad Orthop Surg"},{"key":"3298_CR14","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","volume":"24","author":"B Schliemann","year":"2015","unstructured":"Schliemann B, Hartensuer R, Koch T et al (2015) Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elb Surg 24:1282\u20131288. https:\/\/doi.org\/10.1016\/j.jse.2014.12.028","journal-title":"J Shoulder Elb Surg"},{"issue":"Suppl 1","key":"3298_CR15","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1007\/s12306-015-0371-2","volume":"99","author":"R Rotini","year":"2015","unstructured":"Rotini R, Cavaciocchi M, Fabbri D et al (2015) Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate. Musculoskelet Surg 99(Suppl 1):S1-8. https:\/\/doi.org\/10.1007\/s12306-015-0371-2","journal-title":"Musculoskelet Surg"},{"key":"3298_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2016.01.004","author":"JC Katthagen","year":"2016","unstructured":"Katthagen JC, Schwarze M, Warnhoff M et al (2016) Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury. https:\/\/doi.org\/10.1016\/j.injury.2016.01.004","journal-title":"Injury"},{"key":"3298_CR17","doi-asserted-by":"publisher","first-page":"757","DOI":"10.3238\/arztebl.2019.0757","volume":"116","author":"P Ziegler","year":"2019","unstructured":"Ziegler P, Maier S, St\u00f6ckle U et al (2019) The treatment of proximal humerus fracture using internal fixation with fixed-angle plates. Dtsch Aerzteblatt Online 116:757\u2013763. https:\/\/doi.org\/10.3238\/arztebl.2019.0757","journal-title":"Dtsch Aerzteblatt Online"},{"key":"3298_CR18","volume-title":"Statistical power for the social sciences","author":"J Cohen","year":"1988","unstructured":"Cohen J (1988) Statistical power for the social sciences. Laurence Erlbaum Assoc, Hillsdale"},{"key":"3298_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.paid.2016.06.069","author":"GE Gignac","year":"2016","unstructured":"Gignac GE, Szodorai ET (2016) Effect size guidelines for individual differences researchers. Pers Individ Differ. https:\/\/doi.org\/10.1016\/j.paid.2016.06.069","journal-title":"Pers Individ Differ"},{"key":"3298_CR20","doi-asserted-by":"publisher","first-page":"e213","DOI":"10.1016\/j.jse.2018.11.028","volume":"28","author":"JD Barlow","year":"2019","unstructured":"Barlow JD, Logli AL, Steinmann SP et al (2019) Locking-plate fixation of proximal humerus fractures in patients over 60 continues to be associated with a high complication rate. J Shoulder Elb Surg 28:e213\u2013e214. https:\/\/doi.org\/10.1016\/j.jse.2018.11.028","journal-title":"J Shoulder Elb Surg"},{"key":"3298_CR21","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s10195-017-0457-8","volume":"18","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Huber M, Grabowski S et al (2017) Failure and revision rates of proximal humeral fracture treatment with the use of a standardized treatment algorithm at a level-1 trauma center. J Orthop Traumatol 18:265\u2013274. https:\/\/doi.org\/10.1007\/s10195-017-0457-8","journal-title":"J Orthop Traumatol"},{"key":"3298_CR22","doi-asserted-by":"publisher","first-page":"2129","DOI":"10.2106\/JBJS.19.00595","volume":"101","author":"CM Robinson","year":"2019","unstructured":"Robinson CM, Stirling PHC, Goudie EB et al (2019) Complications and long-term outcomes of open reduction and plate fixation of proximal humeral fractures. J Bone Jt Surg - Am 101:2129\u20132139. https:\/\/doi.org\/10.2106\/JBJS.19.00595","journal-title":"J Bone Jt Surg - Am"},{"key":"3298_CR23","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1016\/j.arthro.2014.04.092","volume":"30","author":"JC Katthagen","year":"2014","unstructured":"Katthagen JC, Hennecke D, Jensen G et al (2014) Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings. Arthrosc J Arthrosc Relat Surg 30:1061\u20131067. https:\/\/doi.org\/10.1016\/j.arthro.2014.04.092","journal-title":"Arthrosc J Arthrosc Relat Surg"},{"key":"3298_CR24","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1007\/s00402-002-0465-9","volume":"123","author":"H Lill","year":"2003","unstructured":"Lill H, Hepp P, Korner J et al (2003) Proximal humeral fractures: how stiff should an implant be? Arch Orthop Trauma Surg 123:74\u201381. https:\/\/doi.org\/10.1007\/s00402-002-0465-9","journal-title":"Arch Orthop Trauma Surg"},{"key":"3298_CR25","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s00590-016-1891-7","volume":"27","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Ellwein A, Lutz O et al (2017) Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating. Eur J Orthop Surg Traumatol 27:351\u2013358. https:\/\/doi.org\/10.1007\/s00590-016-1891-7","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3298_CR26","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1007\/s12306-018-0562-8","volume":"102","author":"A Padolino","year":"2018","unstructured":"Padolino A, Porcellini G, Guollo B et al (2018) Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes. Musculoskelet Surg 102:49\u201356. https:\/\/doi.org\/10.1007\/s12306-018-0562-8","journal-title":"Musculoskelet Surg"},{"key":"3298_CR27","doi-asserted-by":"publisher","first-page":"757","DOI":"10.3238\/arztebl.2019.0757","volume":"116","author":"P Ziegler","year":"2019","unstructured":"Ziegler P, Maier S, St\u00f6ckle U et al (2019) The treatment of proximal humerus fracture using internal fixation with fixed-angle plates. Dtsch Arztebl Int 116:757\u2013763. https:\/\/doi.org\/10.3238\/arztebl.2019.0757","journal-title":"Dtsch Arztebl Int"},{"key":"3298_CR28","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s00402-016-2620-8","volume":"137","author":"B Schliemann","year":"2017","unstructured":"Schliemann B, Seifert R, Theisen C et al (2017) PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures. Arch Orthop Trauma Surg 137:63\u201371. https:\/\/doi.org\/10.1007\/s00402-016-2620-8","journal-title":"Arch Orthop Trauma Surg"},{"key":"3298_CR29","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1016\/j.jseint.2021.06.004","volume":"5","author":"AM Foruria","year":"2021","unstructured":"Foruria AM, Martinez-Catalan N, Valencia M et al (2021) Proximal humeral fracture locking plate fixation with anatomic reduction, and a short-and-cemented-screws configuration, dramatically reduces the implant related failure rate in elderly patients. JSES Int 5:992\u20131000. https:\/\/doi.org\/10.1016\/j.jseint.2021.06.004","journal-title":"JSES Int"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-022-03298-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-022-03298-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-022-03298-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,25]],"date-time":"2023-04-25T04:04:24Z","timestamp":1682395464000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-022-03298-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,27]]},"references-count":29,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["3298"],"URL":"https:\/\/doi.org\/10.1007\/s00590-022-03298-9","relation":{},"ISSN":["1432-1068"],"issn-type":[{"type":"electronic","value":"1432-1068"}],"subject":[],"published":{"date-parts":[[2022,5,27]]},"assertion":[{"value":"12 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"H. Lill is consultant with Arthrex (Naples, USA) and DePuy Synthes (Umkirch, Deutschland). R-O Dey Hazra, M. Warnhoff, A. Ellwein. K. Szewczyk, G. Jensen, RM. Blach and A. K\u00fchnapfel state that there are no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was carried out after consulting with the local institutional ethics committee (Approval No. 2013\u20132015) and is in accordance with the national legal requirements. All procedures that were performed complied with the ethical standards of the institutional and\/or national research committee, as well as with the 1975 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all patients prior to their participation in this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Though all patient information is blinded, in this retrospective study, all participants gave their written informed consent to publish the obtained data of the current study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}