{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T23:56:28Z","timestamp":1791244588839,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2023,3,12]],"date-time":"2023-03-12T00:00:00Z","timestamp":1678579200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,3,12]],"date-time":"2023-03-12T00:00:00Z","timestamp":1678579200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"DOI":"10.1007\/s00590-023-03503-3","type":"journal-article","created":{"date-parts":[[2023,3,12]],"date-time":"2023-03-12T04:16:50Z","timestamp":1678594610000},"page":"2911-2920","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Intramedullary fixation of metacarpal and phalangeal bone fractures with bioabsorbable Mg K-wire in 20 cases"],"prefix":"10.1007","volume":"33","author":[{"given":"Bong-Ju","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4059-4969","authenticated-orcid":false,"given":"Chul-Hyung","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young-Ho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seungha","family":"Woo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,12]]},"reference":[{"key":"3503_CR1","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1097\/PRS.0000000000005478","volume":"143","author":"CM Beck","year":"2019","unstructured":"Beck CM, Horesh E, Taub PJ (2019) Intramedullary screw fixation of metacarpal fractures results in excellent functional outcomes: a literature review. Plast Reconstr Surg 143:1111\u20131118. https:\/\/doi.org\/10.1097\/PRS.0000000000005478","journal-title":"Plast Reconstr Surg"},{"key":"3503_CR2","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1016\/j.jhsa.2010.04.032","volume":"35","author":"CL Boulton","year":"2010","unstructured":"Boulton CL, Salzler M, Mudgal CS (2010) Intramedullary cannulated headless screw fixation of a comminuted subcaptial metacarpal fracture: case report. J Hand Surg Am 35:1260\u20131263. https:\/\/doi.org\/10.1016\/j.jhsa.2010.04.032","journal-title":"J Hand Surg Am"},{"key":"3503_CR3","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1053\/jhsu.2001.24145","volume":"26","author":"KJ Bozic","year":"2001","unstructured":"Bozic KJ, Perez LE, Wilson DR, Fitzgibbons PR, Jupiter JB (2001) Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation. J Hand Surg Am 26:755\u2013761. https:\/\/doi.org\/10.1053\/jhsu.2001.24145","journal-title":"J Hand Surg Am"},{"key":"3503_CR4","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/s1067-2516(98)80009-4","volume":"37","author":"AE Burns","year":"1998","unstructured":"Burns AE, Varin J (1998) Poly-l-lactic acid rod fixation results in foot surgery. J Foot Ankle Surg 37:37\u201341. https:\/\/doi.org\/10.1016\/s1067-2516(98)80009-4","journal-title":"J Foot Ankle Surg"},{"key":"3503_CR5","doi-asserted-by":"publisher","first-page":"2252","DOI":"10.1016\/j.injury.2019.10.018","volume":"50","author":"SM Cha","year":"2019","unstructured":"Cha SM, Shin HD, Kim YK (2019) Comparison of low-profile locking plate fixation versus antegrade intermedullary nailing for unstable metacarpal shaft fractures\u2014a prospective comparative study. Injury 50:2252\u20132258. https:\/\/doi.org\/10.1016\/j.injury.2019.10.018","journal-title":"Injury"},{"key":"3503_CR6","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.jhsa.2014.11.023","volume":"40","author":"F del Pi\u00f1al","year":"2015","unstructured":"del Pi\u00f1al F, Moraleda E, R\u00faas JS, de Piero GH, Cerezal L (2015) Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws. J Hand Surg Am 40:692\u2013700. https:\/\/doi.org\/10.1016\/j.jhsa.2014.11.023","journal-title":"J Hand Surg Am"},{"key":"3503_CR7","doi-asserted-by":"publisher","first-page":"2205","DOI":"10.1097\/PRS.0b013e3181f830ad","volume":"126","author":"JB Friedrich","year":"2010","unstructured":"Friedrich JB, Vedder NB (2010) An evidence-based approach to metacarpal fractures. Plast Reconstr Surg 126:2205\u20132209. https:\/\/doi.org\/10.1097\/PRS.0b013e3181f830ad","journal-title":"Plast Reconstr Surg"},{"key":"3503_CR8","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1080\/02841850802709201","volume":"50","author":"TE Gudmundsen","year":"2009","unstructured":"Gudmundsen TE, Borgen L (2009) Fractures of the fifth metacarpal. Acta Radiol 50:296\u2013300. https:\/\/doi.org\/10.1080\/02841850802709201","journal-title":"Acta Radiol"},{"key":"3503_CR9","first-page":"360","volume":"18","author":"C Huang","year":"2004","unstructured":"Huang C, Li J, Zhu J, Li P, Xie G, Gong Y (2004) A comparative study on two different absorbable intramedullary nails in treating metacarpal and phalanx fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 18:360\u2013363","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"3503_CR10","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1097\/01.blo.0000205884.81328.cc","volume":"445","author":"TB Hughes","year":"2006","unstructured":"Hughes TB (2006) Bioabsorbable implants in the treatment of hand fractures: an update. Clin Orthop Relat Res 445:169\u2013174. https:\/\/doi.org\/10.1097\/01.blo.0000205884.81328.cc","journal-title":"Clin Orthop Relat Res"},{"key":"3503_CR11","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/00006534-200207000-00006","volume":"110","author":"Y-K Kim","year":"2002","unstructured":"Kim Y-K, Kim S-G (2002) Treatment of mandible fractures using bioabsorbable plates. Plast Reconstr Surg 110:323. https:\/\/doi.org\/10.1097\/00006534-200207000-00006","journal-title":"Plast Reconstr Surg"},{"key":"3503_CR12","doi-asserted-by":"publisher","first-page":"8714","DOI":"10.1016\/j.actbio.2012.10.008","volume":"9","author":"J Kuhlmann","year":"2013","unstructured":"Kuhlmann J, Bartsch I, Willbold E et al (2013) Fast escape of hydrogen from gas cavities around corroding magnesium implants. Acta Biomater 9:8714\u20138721. https:\/\/doi.org\/10.1016\/j.actbio.2012.10.008","journal-title":"Acta Biomater"},{"key":"3503_CR13","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/s00590-019-02587-0","volume":"30","author":"P Lazarus","year":"2020","unstructured":"Lazarus P, Hidalgo Diaz JJ, Xaxier F, Gouzou S, Facca S, Fiverneaux P (2020) Transverse and oblique fractures of the diaphysis of the fifth metacarpal\u202f: surgical outcomes for antegrade intramedullary pinning versus combined antegrade and retrograde intramedullary pinning. Eur J Orthop Surg Traumatol 30:425\u2013433. https:\/\/doi.org\/10.1007\/s00590-019-02587-0","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3503_CR14","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1073\/pnas.1518238113","volume":"113","author":"J-W Lee","year":"2016","unstructured":"Lee J-W, Han H-S, Han K-J et al (2016) Long-term clinical study and multiscale analysis of in vivo biodegradation mechanism of Mg alloy. Proc Natl Acad Sci USA 113:716\u2013721. https:\/\/doi.org\/10.1073\/pnas.1518238113","journal-title":"Proc Natl Acad Sci USA"},{"key":"3503_CR15","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1016\/S0749-0712(21)00574-6","volume":"16","author":"SG Lee","year":"2000","unstructured":"Lee SG, Jupiter JB (2000) Phalangeal and metacarpal fractures of the hand. Hand Clin 16:323\u2013332","journal-title":"Hand Clin"},{"key":"3503_CR16","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1007\/s11552-012-9442-0","volume":"7","author":"MN Nakashian","year":"2012","unstructured":"Nakashian MN, Pointer L, Owens BD, Wolf JM (2012) Incidence of metacarpal fractures in the US population. HAND (NY) 7:426\u2013430. https:\/\/doi.org\/10.1007\/s11552-012-9442-0","journal-title":"HAND (NY)"},{"key":"3503_CR17","doi-asserted-by":"publisher","first-page":"2547","DOI":"10.1016\/j.jhsa.2012.09.022","volume":"37","author":"W Peiji","year":"2012","unstructured":"Peiji W, Qirong D, Jianzhong Q, Huayi W, Kailong Z, Nan Y (2012) Intramedullary fixation in digital replantation using bioabsorbable poly-dl-lactic acid rods. J Hand Surg Am 37:2547\u20132552. https:\/\/doi.org\/10.1016\/j.jhsa.2012.09.022","journal-title":"J Hand Surg Am"},{"key":"3503_CR18","doi-asserted-by":"publisher","first-page":"218","DOI":"10.5923\/j.ajbe.20120206.02","volume":"2","author":"GEJ Poinern","year":"2012","unstructured":"Poinern GEJ, Brundavanam S, Fawcett D (2012) Biomedical magnesium alloys: a review of material properties, surface modifications and potential as a biodegradable orthopaedic implant. Am J Biomed Eng 2:218\u2013240. https:\/\/doi.org\/10.5923\/j.ajbe.20120206.02","journal-title":"Am J Biomed Eng"},{"key":"3503_CR19","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1007\/s004020100279","volume":"121","author":"S Stahl","year":"2001","unstructured":"Stahl S, Schwartz O (2001) Complications of K-wire fixation of fractures and dislocations in the hand and wrist. Arch Orthop Trauma Surg 121:527\u2013530. https:\/\/doi.org\/10.1007\/s004020100279","journal-title":"Arch Orthop Trauma Surg"},{"key":"3503_CR20","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1053\/jhsu.2000.4214","volume":"25","author":"PJ Stern","year":"2000","unstructured":"Stern PJ (2000) Management of fractures of the hand over the last 25 years. J Hand Surg Am 25:817\u2013823. https:\/\/doi.org\/10.1053\/jhsu.2000.4214","journal-title":"J Hand Surg Am"},{"key":"3503_CR21","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1177\/1753193420919060","volume":"45","author":"L Urbanschitz","year":"2020","unstructured":"Urbanschitz L, Dreu M, Wagner J, Kaufmann R, Jeserschek JM, Borbas P (2020) Cartilage and extensor tendon defects after headless compression screw fixation of phalangeal and metacarpal fractures. J Hand Surg Eur 45:601\u2013607. https:\/\/doi.org\/10.1177\/1753193420919060","journal-title":"J Hand Surg Eur"},{"key":"3503_CR22","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1177\/0885328212472215","volume":"28","author":"H Waizy","year":"2014","unstructured":"Waizy H, Diekmann J, Weizbauer A et al (2014) In vivo study of a biodegradable orthopedic screw (MgYREZr-alloy) in a rabbit model for up to 12 months. J Biomater Appl 28:667\u2013675. https:\/\/doi.org\/10.1177\/0885328212472215","journal-title":"J Biomater Appl"},{"key":"3503_CR23","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1177\/1558944719836214","volume":"15","author":"WJ Warrender","year":"2020","unstructured":"Warrender WJ, Ruchelsman DE, Livesey MG, Mudgal CS, Rivlin M (2020) Low rate of complications following intramedullary headless compression screw fixation of metacarpal fractures. HAND (NY) 15:798\u2013804. https:\/\/doi.org\/10.1177\/1558944719836214","journal-title":"HAND (NY)"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-023-03503-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-023-03503-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-023-03503-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T04:08:31Z","timestamp":1694750911000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-023-03503-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,12]]},"references-count":23,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2023,10]]}},"alternative-id":["3503"],"URL":"https:\/\/doi.org\/10.1007\/s00590-023-03503-3","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,12]]},"assertion":[{"value":"4 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no potential conflict of interest with respect to the research, authorship, and\/or publication of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval to report these cases was obtained from the Institutional Review Board of Daejeon Sun Hospital (DSH-\uc778-22\u201304). The study conforms to the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from the patient(s) for their anonymized information to be published in this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}