{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T18:23:05Z","timestamp":1793816585521,"version":"4.6.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T00:00:00Z","timestamp":1705622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T00:00:00Z","timestamp":1705622400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Globus Medical, Inc."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"DOI":"10.1007\/s00590-023-03821-6","type":"journal-article","created":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T12:02:41Z","timestamp":1705665761000},"page":"1457-1463","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["A feasibility cadaver study for placing screws in various pelvic osseous fracture pathways using a robotic arm"],"prefix":"10.1007","volume":"34","author":[{"given":"Austin F.","family":"Smith","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matin","family":"Lendhey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jalen","family":"Winfield","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan M.","family":"Mahoney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brandon S.","family":"Bucklen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jon B.","family":"Carlson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,19]]},"reference":[{"key":"3821_CR1","doi-asserted-by":"publisher","first-page":"899","DOI":"10.5435\/JAAOS-D-18-00102","volume":"27","author":"D Banaszek","year":"2019","unstructured":"Banaszek D, Starr AJ, Lefaivre KA (2019) Technical considerations and fluoroscopy in percutaneous fixation of the pelvis and acetabulum. J Am Acad Orthop Surg 27:899\u2013908","journal-title":"J Am Acad Orthop Surg"},{"key":"3821_CR2","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1097\/BOT.0b013e3181847a42","volume":"22","author":"SE Porter","year":"2008","unstructured":"Porter SE, Russell GV, Qin Z et al (2008) Operative fixation of acetabular fractures in the pregnant patient. J Orthop Trauma 22:508\u2013516","journal-title":"J Orthop Trauma"},{"key":"3821_CR3","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1097\/BOT.0b013e3181cf0404","volume":"24","author":"MJ Gardner","year":"2010","unstructured":"Gardner MJ, Morshed S, Nork SE et al (2010) Quantification of the upper and second sacral segment safe zones in normal and dysmorphic sacra. J Orthop Trauma 24:622\u2013629","journal-title":"J Orthop Trauma"},{"key":"3821_CR4","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s00402-013-1788-4","volume":"133","author":"J Zwingmann","year":"2013","unstructured":"Zwingmann J, Hauschild O, Bode G et al (2013) Malposition and revision rates of different imaging modalities for percutaneous iliosacral screw fixation following pelvic fractures: a systematic review and meta-analysis. Arch Orthop Trauma Surg 133:1257\u20131265","journal-title":"Arch Orthop Trauma Surg"},{"key":"3821_CR5","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1007\/s00464-017-5796-2","volume":"32","author":"M Zelhart","year":"2018","unstructured":"Zelhart M, Kaiser AM (2018) Robotic versus laparoscopic versus open colorectal surgery: towards defining criteria to the right choice. Surg Endosc 32:24\u201338","journal-title":"Surg Endosc"},{"key":"3821_CR6","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1097\/GRF.0000000000000274","volume":"60","author":"CA Matthews","year":"2017","unstructured":"Matthews CA (2017) New developments in robotics and single-site gynecologic surgery. Clin Obstet Gynecol 60:296\u2013311","journal-title":"Clin Obstet Gynecol"},{"issue":"7","key":"3821_CR7","doi-asserted-by":"publisher","first-page":"2329","DOI":"10.1007\/s00345-020-03508-1","volume":"39","author":"H John","year":"2021","unstructured":"John H, Wagner C, Padevit C, Witt JH (2021) From open simple to robotic-assisted simple prostatectomy (RASP) for large benign prostate hyperplasia: the time has come. World J Urol 39(7):2329\u20132336https:\/\/doi.org\/10.1007\/s00345-020-03508-1","journal-title":"World J Urol"},{"issue":"5","key":"3821_CR8","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1001\/jamasurg.2020.0034","volume":"155","author":"AS Prabhu","year":"2020","unstructured":"Prabhu AS, Carbonell A, Hope W, Warren J, Higgins R, Jacob B, Blatnik J, Haskins I, Alkhatib H, Tastaldi L, Fafaj A, Tu C, Rosen MJ (2020) Robotic inguinal vs transabdominal laparoscopic inguinal hernia repair: the RIVAL randomized clinical trial. JAMA Surg 155(5):380\u2013387. https:\/\/doi.org\/10.1001\/jamasurg.2020.0034","journal-title":"JAMA Surg"},{"key":"3821_CR9","doi-asserted-by":"publisher","first-page":"847","DOI":"10.5435\/JAAOS-D-19-00328","volume":"28","author":"BG Domb","year":"2020","unstructured":"Domb BG, Chen JW, Lall AC et al (2020) Minimum 5-year outcomes of robotic-assisted primary total hip arthroplasty with a nested comparison against manual primary total hip arthroplasty: a propensity score-matched study. J Am Acad Orthop Surg 28:847\u2013856","journal-title":"J Am Acad Orthop Surg"},{"key":"3821_CR10","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1302\/0301-620X.100B7.BJJ-2017-1449.R1","volume":"100-B","author":"B Kayani","year":"2018","unstructured":"Kayani B, Konan S, Tahmassebi J et al (2018) Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study. Bone Joint J 100-B:930\u2013937","journal-title":"Bone Joint J"},{"key":"3821_CR11","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1055\/s-0039-1700837","volume":"34","author":"AF Smith","year":"2021","unstructured":"Smith AF, Eccles CJ, Bhimani SJ et al (2021) Improved patient satisfaction following robotic-assisted total knee arthroplasty. J Knee Surg 34:730\u2013738","journal-title":"J Knee Surg"},{"key":"3821_CR12","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.ST.19.00020","volume":"10","author":"IH Lieberman","year":"2020","unstructured":"Lieberman IH, Kisinde S, Hesselbacher S (2020) Robotic-assisted pedicle screw placement during spine surgery. JBJS Essent Surg Tech 10:e0020","journal-title":"JBJS Essent Surg Tech"},{"issue":"11","key":"3821_CR13","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1097\/BOT.0000000000001796","volume":"34","author":"J Shaw","year":"2020","unstructured":"Shaw J, Gary J, Ambrose C, Routt MC (2020) Multidimensional pelvic fluoroscopy: a new and novel technique for assessing safety and accuracy of percutaneous iliosacral screw fixation. J Orthop Trauma 34(11):572\u2013577. https:\/\/doi.org\/10.1097\/BOT.0000000000001796","journal-title":"J Orthop Trauma"},{"issue":"2","key":"3821_CR14","doi-asserted-by":"publisher","first-page":"S37","DOI":"10.1097\/BOT.0000000000001403","volume":"33","author":"ML Routt Jr","year":"2019","unstructured":"Routt ML Jr, Gary JL, Kellam JF, Burgess AR (2019) Improved intraoperative fluoroscopy for pelvic and acetabular surgery. J Orthop Trauma 33(2):S37\u2013S42. https:\/\/doi.org\/10.1097\/BOT.0000000000001403","journal-title":"J Orthop Trauma"},{"key":"3821_CR15","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s40634-022-00476-w","volume":"9","author":"JB Carlson","year":"2022","unstructured":"Carlson JB, Zou J, Hartley B (2022) Placement of LC-II and trans-sacral screws using a robotic arm in a simulated bone model in the supine position\u2014a feasibility study. J Exp Orthop 9:36","journal-title":"J Exp Orthop"},{"key":"3821_CR16","doi-asserted-by":"publisher","first-page":"E14","DOI":"10.3171\/2017.3.FOCUS179","volume":"42","author":"G Molliqaj","year":"2017","unstructured":"Molliqaj G, Schatlo B, Alaid A et al (2017) Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery. Neurosurg Focus 42:E14","journal-title":"Neurosurg Focus"},{"key":"3821_CR17","doi-asserted-by":"publisher","first-page":"824","DOI":"10.21037\/atm-20-1106","volume":"8","author":"Y-N Peng","year":"2020","unstructured":"Peng Y-N, Tsai L-C, Hsu H-C et al (2020) Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials. Ann Transl Med 8:824","journal-title":"Ann Transl Med"},{"key":"3821_CR18","doi-asserted-by":"publisher","first-page":"636","DOI":"10.3171\/2014.3.SPINE13714","volume":"20","author":"B Schatlo","year":"2014","unstructured":"Schatlo B, Molliqaj G, Cuvinciuc V et al (2014) Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison. J Neurosurg Spine 20:636\u2013643","journal-title":"J Neurosurg Spine"},{"key":"3821_CR19","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s41016-018-0131-x","volume":"4","author":"B Jiang","year":"2018","unstructured":"Jiang B, Karim Ahmed A, Zygourakis CC et al (2018) Pedicle screw accuracy assessment in ExcelsiusGPS\u00ae robotic spine surgery: evaluation of deviation from pre-planned trajectory. Chin Neurosurg J 4:23","journal-title":"Chin Neurosurg J"},{"key":"3821_CR20","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1177\/2192568219879083","volume":"10","author":"AR Vaccaro","year":"2020","unstructured":"Vaccaro AR, Harris JA, Hussain MM et al (2020) Assessment of surgical procedural time, pedicle screw accuracy, and clinician radiation exposure of a novel robotic navigation system compared with conventional open and percutaneous freehand techniques: a cadaveric investigation. Global Spine J 10:814\u2013825","journal-title":"Global Spine J"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-023-03821-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-023-03821-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-023-03821-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,29]],"date-time":"2024-03-29T18:04:10Z","timestamp":1711735450000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-023-03821-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,19]]},"references-count":20,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["3821"],"URL":"https:\/\/doi.org\/10.1007\/s00590-023-03821-6","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,19]]},"assertion":[{"value":"25 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors report several conflicts of interest pertaining to this manuscript:","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"It is not required for this research investigation, as it involved no human or animal subjects.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent, and ethical approval"}}]}}