{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T21:20:02Z","timestamp":1790112002101,"version":"4.0.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,3,29]],"date-time":"2024-03-29T00:00:00Z","timestamp":1711670400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,29]],"date-time":"2024-03-29T00:00:00Z","timestamp":1711670400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007833","name":"Hamad Medical Corporation","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100007833","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Minimally invasive percutaneous screw fixation for pelvic ring and acetabular fractures has become increasingly popular due to its numerous benefits. However, the precise placement of the screw remains a critical challenge, necessitating a modification of the current techniques. This paper introduces a refined technique employing a modified guidewire to enhance the precision and efficiency of percutaneous fixation in pelvic and acetabular fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This study details the surgical techniques implemented for correcting guidewire misdirection in percutaneous screw fixation and includes a retrospective analysis of patients treated with this modified approach over a three-year period.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In this study, 25 patients with pelvic ring and acetabular fractures underwent percutaneous screw fixation. The cohort, predominantly male (23 out of 25), had an average age of 38\u00a0years. The majority of injuries were due to traffic accidents (18 out of 25). Types of injuries included pelvic ring (6 cases), acetabular fractures (8 cases), and combined injuries (11 cases). Various screw types, including antegrade and retrograde anterior column screws, retrograde posterior column screws, and lateral compression screws, were used, tailored to each case. Over an average follow-up of 18\u00a0months, there were no additional procedures or complications, such as neurovascular injury or hardware failure, indicating successful outcomes in all cases.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This study introduces a simple yet effective method to address guidewire misdirection during percutaneous fixation for pelvic and acetabular fractures, offering enhanced precision and potentially better patient outcomes. Further research with a larger patient cohort is required for a more comprehensive understanding of its efficacy compared to traditional methods.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence <\/jats:title>\n                <jats:p> IV. Therapeutic Study (Surgical technique and Cases-series).<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00590-024-03905-x","type":"journal-article","created":{"date-parts":[[2024,3,29]],"date-time":"2024-03-29T04:48:21Z","timestamp":1711687701000},"page":"2107-2112","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Optimizing percutaneous reduction and fixation with guidewire modification in pelvic and acetabular fractures: surgical technique and case series"],"prefix":"10.1007","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0377-0209","authenticated-orcid":false,"given":"Aiman","family":"Mudawi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osama","family":"Alzobi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jawad Nouraldeen","family":"Derbas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghalib","family":"Ahmed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maamoun","family":"Abousamhadaneh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,29]]},"reference":[{"issue":"2","key":"3905_CR1","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1097\/TA.0b013e3182ab0cde","volume":"76","author":"H Yoshihara","year":"2014","unstructured":"Yoshihara H, Yoneoka D (2014) Demographic epidemiology of unstable pelvic fracture in the United States from 2000 to 2009: trends and in-hospital mortality. J Trauma Acute Care Surg 76(2):380\u2013385. https:\/\/doi.org\/10.1097\/TA.0b013e3182ab0cde","journal-title":"J Trauma Acute Care Surg"},{"issue":"3","key":"3905_CR2","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","volume":"9","author":"ML Routt","year":"1995","unstructured":"Routt ML, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9(3):207\u2013214. https:\/\/doi.org\/10.1097\/00005131-199506000-00005","journal-title":"J Orthop Trauma"},{"key":"3905_CR3","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-024-06087-7","author":"M Arbash","year":"2024","unstructured":"Arbash M, Alzobi OZ, Salameh M, Alkhayarin M, Ahmed G (2024) Incidence, risk factors, and prognosis of sciatic nerve injury in acetabular fractures: a retrospective cross-sectional study. Int Orthop. https:\/\/doi.org\/10.1007\/s00264-024-06087-7","journal-title":"Int Orthop"},{"issue":"5","key":"3905_CR4","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1302\/2058-5241.3.170054","volume":"3","author":"H Caviglia","year":"2018","unstructured":"Caviglia H, Mejail A, Landro ME, Vatani N (2018) Percutaneous fixation of acetabular fractures. EFORT Open Rev 3(5):326\u2013334. https:\/\/doi.org\/10.1302\/2058-5241.3.170054","journal-title":"EFORT Open Rev"},{"issue":"2","key":"3905_CR5","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1097\/BOT.0b013e318216b3e3","volume":"26","author":"N Kazemi","year":"2012","unstructured":"Kazemi N, Archdeacon MT (2012) Immediate full weightbearing after percutaneous fixation of anterior column acetabulum fractures. J Orthop Trauma 26(2):73\u201379. https:\/\/doi.org\/10.1097\/BOT.0b013e318216b3e3","journal-title":"J Orthop Trauma"},{"issue":"1","key":"3905_CR6","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1097\/BOT.0b013e318288c0c3","volume":"28","author":"C Yi","year":"2014","unstructured":"Yi C, Burns S, Hak DJ (2014) Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery. J Orthop Trauma 28(1):48\u201356. https:\/\/doi.org\/10.1097\/BOT.0b013e318288c0c3","journal-title":"J Orthop Trauma"},{"issue":"24","key":"3905_CR7","doi-asserted-by":"publisher","first-page":"899","DOI":"10.5435\/JAAOS-D-18-00102","volume":"27","author":"D Banaszek","year":"2019","unstructured":"Banaszek D, Starr AJ, Lefaivre KA (2019) Technical considerations and fluoroscopy in percutaneous fixation of the pelvis and acetabulum. J Am Acad Orthop Surg 27(24):899\u2013908. https:\/\/doi.org\/10.5435\/JAAOS-D-18-00102","journal-title":"J Am Acad Orthop Surg"},{"key":"3905_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-023-06002-6","author":"A Elmhiregh","year":"2023","unstructured":"Elmhiregh A, Hantouly AT, Alzobi O, George B, Ahmadi M, Ahmed G (2023) The optimal fluoroscopic views to rule out intra-articular screw penetration during acetabular fracture fixation. Int Orthop. https:\/\/doi.org\/10.1007\/s00264-023-06002-6","journal-title":"Int Orthop"},{"issue":"2","key":"3905_CR9","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1148\/radiology.160.2.3726125","volume":"160","author":"JW Young","year":"1986","unstructured":"Young JW, Burgess AR, Brumback RJ, Poka A (1986) Pelvic fractures: value of plain radiography in early assessment and management. Radiology 160(2):445\u2013451. https:\/\/doi.org\/10.1148\/radiology.160.2.3726125","journal-title":"Radiology"},{"key":"3905_CR10","doi-asserted-by":"crossref","unstructured":"Letournel E, Judet R (1981) Fractures of the acetabulum. In R. A. Elson (Ed.), Berlin (Heidelburg): SpringerVerlag.","DOI":"10.1007\/978-3-662-02325-9"},{"key":"3905_CR11","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/00005131-199801000-00009","volume":"12","author":"AJ Starr","year":"1998","unstructured":"Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12:51\u201358","journal-title":"J Orthop Trauma"},{"issue":"12","key":"3905_CR12","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1016\/j.injury.2010.07.502","volume":"41","author":"BG Ochs","year":"2010","unstructured":"Ochs BG, Gonser C, Shiozawa T, Badke A, Weise K, Rolauffs B, Stuby FM (2010) Computer-assisted periacetabular screw placement: comparison of different fluoroscopy-based navigation procedures with conventional technique. Injury 41(12):1297\u20131305. https:\/\/doi.org\/10.1016\/j.injury.2010.07.502","journal-title":"Injury"},{"key":"3905_CR13","doi-asserted-by":"publisher","first-page":"3107","DOI":"10.1007\/s00590-023-03543-9","volume":"33","author":"OZ Alzobi","year":"2023","unstructured":"Alzobi OZ, Alborno Y, Toubasi A et al (2023) Complications of conventional percutaneous sacroiliac screw fixation of traumatic pelvic ring injuries: a systematic review and meta-analysis. Eur J Orthop Surg Traumatol 33:3107\u20133117","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"10","key":"3905_CR14","doi-asserted-by":"publisher","first-page":"675","DOI":"10.3928\/01477447-20140924-04","volume":"37","author":"AE Bozzio","year":"2014","unstructured":"Bozzio AE, Wydra FB, Mitchell JJ, Ackerson RM, Mauffrey C (2014) Percutaneous fixation of anterior and posterior column acetabular fractures. Orthopedics 37(10):675\u2013678. https:\/\/doi.org\/10.3928\/01477447-20140924-04","journal-title":"Orthopedics"},{"key":"3905_CR15","doi-asserted-by":"publisher","first-page":"107701","DOI":"10.1016\/j.ijscr.2022.107701","volume":"99","author":"A Mudawi","year":"2022","unstructured":"Mudawi A, Moghamis IS, Alzobi O, Babikir E, Abdelsalam S, Samhadaneh MA (2022) Bilateral pelvic crescent fracture combined with left acetabular fracture: a case report. Int J Surg Case Rep 99:107701. https:\/\/doi.org\/10.1016\/j.ijscr.2022.107701","journal-title":"Int J Surg Case Rep"},{"key":"3905_CR16","doi-asserted-by":"publisher","DOI":"10.25259\/JMSR_127_2023","author":"AT Hantouly","year":"2023","unstructured":"Hantouly AT, Salman LA, Toubasi AT, Alzobi O, Alborno Y, Kayali H et al (2023) Prone or lateral patient positioning in Kocher Langenbeck approach in acetabular fractures fixation: a systematic review and meta-analysis. J Musculoskelet Surg Res. https:\/\/doi.org\/10.25259\/JMSR_127_2023","journal-title":"J Musculoskelet Surg Res"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-024-03905-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-024-03905-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-024-03905-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T16:06:00Z","timestamp":1715961960000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-024-03905-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,29]]},"references-count":16,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,5]]}},"alternative-id":["3905"],"URL":"https:\/\/doi.org\/10.1007\/s00590-024-03905-x","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,29]]},"assertion":[{"value":"27 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors, including Aiman Mudawi, Osama Alzobi, Jawad Nouraldeen Derbas, Ghalib Ahmed, and Maamoun Abousamhadaneh declare that they have no funding or commercial associations (e.g., consultancies, stock ownership, equity interest, patent\/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"There is a statement of the Institutional Review Board for this work.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"All authors have approved the publication.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}