{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T12:43:56Z","timestamp":1787921036797,"version":"build-2784847793"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T00:00:00Z","timestamp":1712016000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T00:00:00Z","timestamp":1712016000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"DOI":"10.1007\/s00590-024-03919-5","type":"journal-article","created":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T15:02:46Z","timestamp":1712070166000},"page":"2147-2153","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?"],"prefix":"10.1007","volume":"34","author":[{"given":"Michael","family":"Kutzler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph T.","family":"Patterson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hayden","family":"Anz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Siahaan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen J.","family":"Warner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6326-2468","authenticated-orcid":false,"given":"Joshua L.","family":"Gary","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,2]]},"reference":[{"key":"3919_CR1","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.2174\/1874325001711011277","volume":"11","author":"AM Khan","year":"2017","unstructured":"Khan AM, Tang QO, Spicer D (2017) The epidemiology of adult distal femoral shaft fractures in a Central London major trauma centre over five years. Open Orthop J 11:1277\u20131291","journal-title":"Open Orthop J"},{"issue":"3","key":"3919_CR2","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/S0020-1383(00)80034-0","volume":"31","author":"O Martinet","year":"2000","unstructured":"Martinet O, Cordey J, Harder Y, Maier A, Buhler M, Barraud GE (2000) The epidemiology of fractures of the distal femur. Injury 31(3):62\u201394","journal-title":"Injury"},{"key":"3919_CR3","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/s00264-017-3665-1","volume":"42","author":"R Elsoe","year":"2018","unstructured":"Elsoe R, Ceccotti AA, Larsen P (2018) Population-based epidemiology and incidence of distal femur fractures. Int Orthop (SICOT) 42:191\u2013196","journal-title":"Int Orthop (SICOT)"},{"issue":"2","key":"3919_CR4","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1016\/j.injury.2021.11.037","volume":"53","author":"C Vemulapalli","year":"2022","unstructured":"Vemulapalli C, Pechero G, Warner S, Achor T, Gary JL, Munz J et al (2022) Is retrograde nailing superior to lateral locked plating for complete articular distal femur fractures? Injury 53(2):640\u2013644","journal-title":"Injury"},{"issue":"4","key":"3919_CR5","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1097\/BOT.0000000000002553","volume":"37","author":"R Cone","year":"2023","unstructured":"Cone R, Roszman A, Conway Y, Cichos K, McGwin G, Spitler C (2023) Risk factors for nonunion of distal femur fractures. J Orthop Trauma 37(4):175\u2013180","journal-title":"J Orthop Trauma"},{"key":"3919_CR6","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.jor.2019.09.022","volume":"18","author":"M Bologna","year":"2019","unstructured":"Bologna M, Claudio M, Shields K, Katz C, Salopek T, Westrick E (2019) Dual plate fixation results in improved union rates in comminuted distal femur fractures compared to single plate fixation. J Orthop 18:76\u201379","journal-title":"J Orthop"},{"key":"3919_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0020-1383(91)90123-V","volume":"22","author":"SM Perren","year":"1991","unstructured":"Perren SM (1991) The concept of biological plating using the limited contact \u2014 dynamic compression plate (LC-DCP). Injury 22:1\u201341","journal-title":"Injury"},{"issue":"10","key":"3919_CR8","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1097\/BOT.0b013e31823b8964","volume":"26","author":"MF Hoffmann","year":"2012","unstructured":"Hoffmann MF, Jnes CB, Sietsema DL, Maatman BT, Sink EM (2012) Determination of sagittal alignment measurements in distal femurs. J Orthop Trauma 26(10):183\u2013187","journal-title":"J Orthop Trauma"},{"key":"3919_CR9","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1016\/j.injury.2021.11.037","volume":"53","author":"KC Vemulapalli","year":"2022","unstructured":"Vemulapalli KC, Pechero GR, Warner SJ, Achor TS, Gary JL, Munz JW, Choo AM, Prasarn ML, RouttJr MC (2022) Is retrograde nailing superior to lateral locked plating for complete articular distal femur fractures? Injury 53:640\u2013644","journal-title":"Injury"},{"issue":"19","key":"3919_CR10","doi-asserted-by":"publisher","first-page":"867","DOI":"10.5435\/JAAOS-D-17-00706","volume":"27","author":"ME Hake","year":"2019","unstructured":"Hake ME, Davis M, Perdue A, Goulet J (2019) Modern implant options for the treatment of distal femur fractures. J Am Acad Orthop Surg 27(19):867\u2013875","journal-title":"J Am Acad Orthop Surg"},{"issue":"8","key":"3919_CR11","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1097\/00005131-200409000-00006","volume":"18","author":"PJ Kregor","year":"2004","unstructured":"Kregor PJ, Stannard JA, Zlowodzki M, Cole PA (2004) Treatment of distal femur fractures using the less invasive stabilization system. J Orthop Trauma 18(8):509\u2013520","journal-title":"J Orthop Trauma"},{"issue":"2","key":"3919_CR12","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1007\/s00402-004-0779-x","volume":"125","author":"M Sch\u00fctz","year":"2005","unstructured":"Sch\u00fctz M, Muller M, Regazzoni P, Hontzsch D, Krettek C, Van der Werken C et al (2005) Use of the Less Invasive Stabilization System (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study. Arch Orthop Trauma Surg 125(2):102\u2013108","journal-title":"Arch Orthop Trauma Surg"},{"issue":"11","key":"3919_CR13","doi-asserted-by":"publisher","first-page":"2597","DOI":"10.1016\/j.injury.2017.08.064","volume":"48","author":"WH Harvin","year":"2017","unstructured":"Harvin WH, Oladeji L, Rocca G, Murtha Y, Volags D, Stannard J et al (2017) Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures. Injury 48(11):2597\u20132601","journal-title":"Injury"},{"key":"3919_CR14","doi-asserted-by":"crossref","unstructured":"Urva M, Challa S, Haonga B, Eliezer E, Working Z, Naga A, et al (2022) Reliability of modified radiographic union score for tibia scores in the evaluation of femoral shaft fractures in a low-resource setting. J Am Acad Orthop Surg. Global Res Rev 6(5)","DOI":"10.5435\/JAAOSGlobal-D-21-00211"},{"issue":"8","key":"3919_CR15","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1097\/BOT.0000000000000593","volume":"30","author":"EK Rodriguez","year":"2016","unstructured":"Rodriguez EK, Zurakowski D, Herder L, Hall A, Walley K, Weaver M et al (2016) Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures. J Orthop Trauma 30(8):403\u2013408","journal-title":"J Orthop Trauma"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-024-03919-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-024-03919-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-024-03919-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T16:06:12Z","timestamp":1715961972000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-024-03919-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,2]]},"references-count":15,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,5]]}},"alternative-id":["3919"],"URL":"https:\/\/doi.org\/10.1007\/s00590-024-03919-5","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,2]]},"assertion":[{"value":"14 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"AOTrauma North America: Research support; Orthopaedic Trauma Association: Board or committee member; DePuy, A Johnson & Johnson Company: Paid consultant. None. AAOS: Board or committee member; DePuy, A Johnson & Johnson Company: Paid consultant; Globus Medical: Paid presenter or speaker; Orthopaedic Trauma Association: Board or committee member; Smith & Nephew: Paid presenter or speaker; Stryker: Paid presenter or speaker. AO North America: Board or committee member; Research support; Journal of Bone and Joint Surgery \u2013 American: Editorial or governing board; Journal of the American Academy of Orthopaedic Surgeons: Editorial or governing board; Orthopaedic Trauma Association: Board or committee member; Smith & Nephew: Paid presenter or speaker; Stryker: Paid presenter or speaker; Summitt Medventures: Stock or stock Options; Wolters Kluwer Health \u2013 Lippincott Williams & Wilkins: Editorial or governing board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the University of Texas Health Science Center at Houston Committee for the Protection of Human subjects: HSC-MS-20\u20131204.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This was a retrospective study from the medical record, and therefore, informed consent was not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}