{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T06:06:49Z","timestamp":1770271609088,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T00:00:00Z","timestamp":1749772800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T00:00:00Z","timestamp":1749772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"DOI":"10.1007\/s00590-025-04346-w","type":"journal-article","created":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T04:24:13Z","timestamp":1749788653000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Fatigue testing of a self-compression screw model in Pauwels III fracture: an in vitro analysis"],"prefix":"10.1007","volume":"35","author":[{"given":"Anderson","family":"Freitas","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincenzo","family":"Giordano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edvalson Francisco","family":"Neves Junior","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulo","family":"Alves Tavares","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robison","family":"Esteves Pires","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"Dias Belangero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro Jos\u00e9","family":"Labronici","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,13]]},"reference":[{"issue":"1","key":"4346_CR1","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1186\/s13018-016-0498-3","volume":"11","author":"M Shen","year":"2016","unstructured":"Shen M, Wang C, Chen H, Rui YF, Zhao S (2016) An update on the Pauwels classification. J Orthop Surg Res 11(1):161. https:\/\/doi.org\/10.1186\/s13018-016-0498-3","journal-title":"J Orthop Surg Res"},{"issue":"12","key":"4346_CR2","doi-asserted-by":"publisher","first-page":"3867","DOI":"10.1016\/j.injury.2022.10.012","volume":"53","author":"V Giordano","year":"2022","unstructured":"Giordano V, Rayes J, Buckley RE (2022) Femoral neck fracture in a young person - ORIF but do we use a medial buttress plate as well on the femoral neck?: OTG 23. Injury 53(12):3867\u20133868. https:\/\/doi.org\/10.1016\/j.injury.2022.10.012","journal-title":"Injury"},{"issue":"6","key":"4346_CR3","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1007\/s00402-017-2689-8","volume":"137","author":"O Filipov","year":"2017","unstructured":"Filipov O, Stoffel K, Gueorguiev B, Sommer C (2017) Femoral neck fracture osteosynthesis by the biplane double-supported screw fixation method (BDSF) reduces the risk of fixation failure: clinical outcomes in 207 patients. Arch Orthop Trauma Surg 137(6):779\u2013788. https:\/\/doi.org\/10.1007\/s00402-017-2689-8","journal-title":"Arch Orthop Trauma Surg"},{"issue":"7","key":"4346_CR4","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1007\/s00590-018-2207-x","volume":"28","author":"V Giordano","year":"2018","unstructured":"Giordano V, Paes RP, Alves DD, Amaral AB, Belangero WD, Giordano M, Freitas A, Koch HA (2018) Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical study. Eur J Orthop Surg Traumatol 28(7):1359\u20131367. https:\/\/doi.org\/10.1007\/s00590-018-2207-x","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"6","key":"4346_CR5","doi-asserted-by":"publisher","first-page":"673","DOI":"10.3944\/AOTT.2014.14.0088","volume":"48","author":"SA G\u00fcm\u00fc\u015fta\u015f","year":"2014","unstructured":"G\u00fcm\u00fc\u015fta\u015f SA, Tosun HB, A\u011f\u0131r \u0130, Orak MM, Onay T, Ok\u00e7u G (2014) Influence of number and orientation of screws on stability in the internal fixation of unstable femoral neck fractures. Acta Orthop Traumatol Turc 48(6):673\u2013678. https:\/\/doi.org\/10.3944\/AOTT.2014.14.0088","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"Suppl 1","key":"4346_CR6","doi-asserted-by":"publisher","first-page":"S33","DOI":"10.1097\/BOT.0000000000001368","volume":"33","author":"AE Levack","year":"2019","unstructured":"Levack AE, Gausden E, Dvorzhinskiy A, Lorich DG, Helfet DL (2019) Novel treatment options for the surgical management of young femoral neck fractures. J Orthop Trauma 33(Suppl 1):S33\u2013S37. https:\/\/doi.org\/10.1097\/BOT.0000000000001368","journal-title":"J Orthop Trauma"},{"issue":"Suppl 2","key":"4346_CR7","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1007\/s43465-021-00420-7","volume":"55","author":"A Freitas","year":"2021","unstructured":"Freitas A, Barin FR, Battaglion LR, da Costa HI, Santos ED, Rosado HA, Giordano M, Giordano V, Shimano AC (2021) Proposal for a new fixation method for Pauwels type III femoral neck fracture-metaphyseal stem: a finite-element analysis. Indian J Orthop 55(Suppl 2):378\u2013384. https:\/\/doi.org\/10.1007\/s43465-021-00420-7","journal-title":"Indian J Orthop"},{"issue":"4","key":"4346_CR8","doi-asserted-by":"publisher","first-page":"449","DOI":"10.4055\/cios20202","volume":"13","author":"T Hiranaka","year":"2021","unstructured":"Hiranaka T, Tanaka T, Okumura K, Fujishiro T, Shigemoto R, Araki S, Okada R, Nako R, Okamoto K (2021) Clinical results of dual SC screw: a mini-sliding hip screw with an anti-rotating screw for femoral neck fractures. Clin Orthop Surg 13(4):449\u2013455. https:\/\/doi.org\/10.4055\/cios20202","journal-title":"Clin Orthop Surg"},{"issue":"5","key":"4346_CR9","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/j.mehy.2015.01.029","volume":"84","author":"H Mir","year":"2015","unstructured":"Mir H, Collinge C (2015) Application of a medial buttress plate may prevent many treatment failures seen after fixation of vertical femoral neck fractures in young adults. Med Hypotheses 84(5):429\u2013433. https:\/\/doi.org\/10.1016\/j.mehy.2015.01.029","journal-title":"Med Hypotheses"},{"issue":"6","key":"4346_CR10","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1016\/j.injury.2011.09.012","volume":"43","author":"PJ Nowotarski","year":"2012","unstructured":"Nowotarski PJ, Ervin B, Weatherby B, Pettit J, Goulet R, Norris B (2012) Biomechanical analysis of a novel femoral neck locking plate for treatment of vertical shear Pauwel\u2019s type C femoral neck fractures. Injury 43(6):802\u2013806. https:\/\/doi.org\/10.1016\/j.injury.2011.09.012","journal-title":"Injury"},{"issue":"1","key":"4346_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4055\/cios.2019.11.1.1","volume":"11","author":"YH Cha","year":"2019","unstructured":"Cha YH, Yoo JI, Hwang SY, Kim KJ, Kim HY, Choy WS, Hwang SC (2019) Biomechanical evaluation of internal fixation of Pauwels type III femoral neck fractures: a systematic review of various fixation methods. Clin Orthop Surg 11(1):1\u201314. https:\/\/doi.org\/10.4055\/cios.2019.11.1.1","journal-title":"Clin Orthop Surg"},{"issue":"9","key":"4346_CR12","doi-asserted-by":"publisher","first-page":"2105","DOI":"10.1007\/s00264-022-05414-0","volume":"46","author":"A Davidson","year":"2022","unstructured":"Davidson A, Blum S, Harats E, Kachko E, Essa A, Efraty R, Peyser A, Giannoudis PV (2022) Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature review. Int Orthop 46(9):2105\u20132115. https:\/\/doi.org\/10.1007\/s00264-022-05414-0","journal-title":"Int Orthop"},{"key":"4346_CR13","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1590\/S0103-73312011000200004","volume":"21","author":"RA Fernandes","year":"2011","unstructured":"Fernandes RA, Ara\u00fajo DV, Takemoto MLS, Sauberman MV (2011) Hip fractures in the elderly: cost of illness study in a public hospital perspective, Rio de Janeiro. Brazil Physis 21:395\u2013416. https:\/\/doi.org\/10.1590\/S0103-73312011000200004","journal-title":"Brazil Physis"},{"key":"4346_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.mehy.2023.111098","volume":"176","author":"A Freitas","year":"2023","unstructured":"Freitas A, Giordano V, Pires RE, Oliveira MM, Battaglion LR, Belangero WD (2023) An anatomically designed implant for femoral neck fractures in young adults: a hypothesis on the role of interfragmentary compression in reducing nonunion and osteonecrosis. Med Hypotheses 176:111098. https:\/\/doi.org\/10.1016\/j.mehy.2023.111098","journal-title":"Med Hypotheses"},{"issue":"4","key":"4346_CR15","doi-asserted-by":"publisher","first-page":"210","DOI":"10.5327\/Z1984-4840201626173","volume":"18","author":"D Sansanovicz","year":"2017","unstructured":"Sansanovicz D, Baras FC, da Silva RJC, de MelloMarin D, da Prota ECB, Vieira LA, de Simoneti CA, Caetano EB (2017) The quality of life after a femoral neck fracture in elderly patients: a comparative study between internal fixation and arthroplasties. Rev Fac Ci\u00eanc M\u00e9d Sorocaba 18(4):210\u2013213. https:\/\/doi.org\/10.5327\/Z1984-4840201626173","journal-title":"Rev Fac Ci\u00eanc M\u00e9d Sorocaba"},{"issue":"1","key":"4346_CR16","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1186\/s13018-018-0901-3","volume":"13","author":"Z Wang","year":"2018","unstructured":"Wang Z, Yin Y, Li Q, Sun G, Peng X, Yin H, Ye Y (2018) Comparison of early complications between the use of a cannulated screw locking plate and multiple cancellous screws in the treatment of displaced intracapsular hip fractures in young adults: a randomized controlled clinical trial. J Orthop Surg Res 13(1):201. https:\/\/doi.org\/10.1186\/s13018-018-0901-3","journal-title":"J Orthop Surg Res"},{"issue":"9","key":"4346_CR17","doi-asserted-by":"publisher","first-page":"464","DOI":"10.3390\/bioengineering9090464","volume":"9","author":"V Giordano","year":"2022","unstructured":"Giordano V, Freitas A, Pires RE, Battaglion LR, Lobo MO, Belangero WD (2022) Evaluation of a locking autocompression screw model in Pauwels type-3 femoral neck fracture: in vitro analysis. Bioengineering (Basel) 9(9):464. https:\/\/doi.org\/10.3390\/bioengineering9090464","journal-title":"Bioengineering (Basel)"},{"issue":"1","key":"4346_CR18","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1186\/s13018-021-02517-z","volume":"16","author":"H Hu","year":"2021","unstructured":"Hu H, Cheng J, Feng M, Gao Z, Wu J, Lu S (2021) Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients. J Orthop Surg Res 16(1):370. https:\/\/doi.org\/10.1186\/s13018-021-02517-z","journal-title":"J Orthop Surg Res"},{"issue":"Suppl 6","key":"4346_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2023.05.041","volume":"54","author":"MM de Oliveira","year":"2023","unstructured":"de Oliveira MM, Freitas A, Giordano V, Moura CMDC, Ferreira BL, Lucas LG, Pires RE, Belangero WD (2023) In vitro biomechanical analysis of a locking self-compression screw model applied to Pauwels III and comminuted femoral neck fractures. Injury 54(Suppl 6):110810. https:\/\/doi.org\/10.1016\/j.injury.2023.05.041","journal-title":"Injury"},{"issue":"3","key":"4346_CR20","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.injury.2014.12.031","volume":"46","author":"M Panteli","year":"2015","unstructured":"Panteli M, Rodham P, Giannoudis PV (2015) Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly. Injury 46(3):445\u2013452. https:\/\/doi.org\/10.1016\/j.injury.2014.12.031","journal-title":"Injury"},{"key":"4346_CR21","doi-asserted-by":"publisher","first-page":"2814548","DOI":"10.1155\/2020\/2814548","volume":"2020","author":"Y Zhang","year":"2020","unstructured":"Zhang Y, Yan C, Zhang L, Zhang W, Wang G (2020) Comparison of ordinary cannulated compression screw and double-head cannulated compression screw fixation in vertical femoral neck fractures. Biomed Res Int 2020:2814548. https:\/\/doi.org\/10.1155\/2020\/2814548","journal-title":"Biomed Res Int"},{"issue":"3","key":"4346_CR22","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","volume":"31","author":"K Stoffel","year":"2017","unstructured":"Stoffel K, Zderic I, Gras F, Sommer C, Eberli U, Mueller D, Oswald M, Gueorguiev B (2017) Biomechanical evaluation of the Femoral Neck System in unstable Pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma 31(3):131\u2013137. https:\/\/doi.org\/10.1097\/BOT.0000000000000739","journal-title":"J Orthop Trauma"},{"issue":"1","key":"4346_CR23","doi-asserted-by":"publisher","first-page":"7915","DOI":"10.1038\/s41598-022-11914-1","volume":"12","author":"JK Moon","year":"2022","unstructured":"Moon JK, Lee JI, Hwang KT, Yang JH, Park YS, Park KC (2022) Biomechanical comparison of the femoral neck system and the dynamic hip screw in basicervical femoral neck fractures. Sci Rep 12(1):7915. https:\/\/doi.org\/10.1038\/s41598-022-11914-1","journal-title":"Sci Rep"},{"issue":"1","key":"4346_CR24","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1186\/s12891-023-06872-2","volume":"24","author":"JC Fisher 3rd","year":"2023","unstructured":"Fisher JC 3rd, Gerzina C, Rush K, Caroom C (2023) Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases. BMC Musculoskelet Disord 24(1):749. https:\/\/doi.org\/10.1186\/s12891-023-06872-2","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"4346_CR25","doi-asserted-by":"publisher","first-page":"e41","DOI":"10.5435\/JAAOS-D-17-00155","volume":"27","author":"J Johnson","year":"2019","unstructured":"Johnson J, Deren M, Chambers A, Cassidy D, Koruprolu S, Born C (2019) Biomechanical analysis of fixation devices for basicervical femoral neck fractures. J Am Acad Orthop Surg 27(1):e41\u2013e48. https:\/\/doi.org\/10.5435\/JAAOS-D-17-00155","journal-title":"J Am Acad Orthop Surg"},{"issue":"4","key":"4346_CR26","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/0021-9290(95)00084-4","volume":"29","author":"L Cristofolini","year":"1996","unstructured":"Cristofolini L, Viceconti M, Cappello A, Toni A (1996) Mechanical validation of whole bone composite femur models. J Biomech 29(4):525\u2013535. https:\/\/doi.org\/10.1016\/0021-9290(95)00084-4","journal-title":"J Biomech"},{"issue":"1","key":"4346_CR27","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1097\/00005131-200401000-00003","volume":"18","author":"EN Kubiak","year":"2004","unstructured":"Kubiak EN, Bong M, Park SS, Kummer F, Egol K, Koval KJ (2004) Intramedullary fixation of unstable intertrochanteric hip fractures: one or two lag screws. J Orthop Trauma 18(1):12\u201317. https:\/\/doi.org\/10.1097\/00005131-200401000-00003","journal-title":"J Orthop Trauma"},{"issue":"1","key":"4346_CR28","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1186\/s12938-022-01006-6","volume":"21","author":"Z Wang","year":"2022","unstructured":"Wang Z, Yang Y, Feng G, Guo H, Chen Z, Chen Y, Jin Q (2022) Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture. Biomed Eng Online 21(1):34. https:\/\/doi.org\/10.1186\/s12938-022-01006-6","journal-title":"Biomed Eng Online"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-025-04346-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-025-04346-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-025-04346-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T13:40:32Z","timestamp":1767015632000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-025-04346-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,13]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4346"],"URL":"https:\/\/doi.org\/10.1007\/s00590-025-04346-w","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,13]]},"assertion":[{"value":"20 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The experiments in this study comply with the current laws of Brazil.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"242"}}