{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T03:49:35Z","timestamp":1776743375651,"version":"3.51.2"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T00:00:00Z","timestamp":1753228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T00:00:00Z","timestamp":1753228800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The Bedrock technique involves fusion of the sacroiliac (SI) joint at the time of long construct spinal fusion extending to the pelvis. This is done with triangular titanium rods (TTR) placed parallel and cephalad to S2AI screws, requiring placement of two implants into the small bony corridor in the teardrop of the pelvis. In our initial 21 cases adopting this technique, we found a 7.1% rate of implant malposition requiring intraoperative repositioning. The objective of this follow-up study was to report on our implant malposition rates over a larger number of cases, to determine a potential learning curve, and to report on strategies for minimizing implant malpositioning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Surgeries in which SI joint fusion was performed concomitant with spinopelvic fixation using the Bedrock Technique with TTRs and CT-navigation between 5\/1\/2019 and 5\/27\/2021 were reviewed. Operative reports were analyzed and any intraoperative TTR\/S2AI screw malpositions were recorded. Demographic\/surgical information, TTR\/S2AI specifications, and PROMs were obtained and analyzed along with risk assessment and correlation of failure between cohorts (\u03b1\u2009&lt;\u20090.05).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 43 patients were included with a mean length of fusion of 4.8 (1\u201314 levels). Overall, 86 TTRs and S2AI screws were implanted of which, 4\/86 (4.7%) TTRs were repositioned intraoperatively and 1\/86 (1.2%) was removed and replaced with allograft, while 0\/86 (0%) S2AI screws were malpositioned. All TTR malpositions were medial and\/or cephalad. In the initial 21 cases, 3\/42 (7.1%) TTRs required intraoperative repositioning; this decreased in the subsequent 22 cases to 2\/44 (4.5%) with a non-significant relative risk of 1.57 (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.664). Malposition was non-significantly negatively correlated to time (r\u2009=\u2009-.135;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u2009.39). Our patients showed statistically significant (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u2009.001) one-year improvements in mean ODI, VAS back, and PROMIS-10 metrics, meeting MCID for ODI and VAS back.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Posterior placement of a TTR above an S2AI screw poses technical challenges due to the natural cephalad narrowing of the bony corridor in the teardrop and blunt tip of the implant which predisposes it to medial skiving as it is passes through the SI joint. Our overall intraoperative reposition rate for caudal S2AI screws was 0% compared to 5.8% for cephalad TTRs, which decreased from 7.1 to 4.5% between our first- and second-year cohorts, suggesting a potential learning curve. All malpositions occurred medially and\/or cephalad, and over time we transitioned our technique to placing implants as low as possible in the teardrop to minimize this risk.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00590-025-04431-0","type":"journal-article","created":{"date-parts":[[2025,7,23]],"date-time":"2025-07-23T04:14:25Z","timestamp":1753244065000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["The Bedrock technique with triangular titanium rods for spinopelvic fixation and sacroiliac joint fusion: is there a learning curve?"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-9004-6912","authenticated-orcid":false,"given":"Cale J.","family":"Hendricks","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8658-8137","authenticated-orcid":false,"given":"Jason J.","family":"Haselhuhn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2979-3214","authenticated-orcid":false,"given":"Paul Brian O.","family":"Soriano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-3595-4347","authenticated-orcid":false,"given":"James T.","family":"Longhurst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6505-4235","authenticated-orcid":false,"given":"Christopher T.","family":"Martin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9002-1774","authenticated-orcid":false,"given":"Jonathan N.","family":"Sembrano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7954-063X","authenticated-orcid":false,"given":"Nathan R.","family":"Hendrickson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2007-028X","authenticated-orcid":false,"given":"Kristen E.","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7572-6584","authenticated-orcid":false,"given":"David W.","family":"Polly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,23]]},"reference":[{"issue":"5","key":"4431_CR1","doi-asserted-by":"publisher","first-page":"E162","DOI":"10.1097\/BRS.0b013e3181978ea3","volume":"34","author":"AA Ivanov","year":"2009","unstructured":"Ivanov AA, Kiapour A, Ebraheim NA, Goel V (2009) Lumbar fusion leads to increases in angular motion and stress across sacroiliac joint. Spine (Phila Pa 1976) 34(5):E162\u2013E169. https:\/\/doi.org\/10.1097\/BRS.0b013e3181978ea3","journal-title":"Spine (Phila Pa 1976)"},{"issue":"17","key":"4431_CR2","doi-asserted-by":"publisher","first-page":"E1024","DOI":"10.1097\/BRS.0000000000003041","volume":"44","author":"E Unoki","year":"2019","unstructured":"Unoki E, Miyakoshi N, Abe E et al (2019) Sacropelvic fixation with s2 alar iliac screws may prevent sacroiliac joint pain after multisegment spinal fusion. Spine (Phila Pa 1976) 44(17):E1024\u2013E1030. https:\/\/doi.org\/10.1097\/BRS.0000000000003041","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"4431_CR3","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1097\/BSD.0000000000001341","volume":"36","author":"M Manzetti","year":"2023","unstructured":"Manzetti M, Ruffilli A, Barile F et al (2023) Sacroiliac joint degeneration and pain after spinal arthrodesis. Clin Spine Surg: Spine Public 36(4):169\u2013182. https:\/\/doi.org\/10.1097\/BSD.0000000000001341","journal-title":"Clin Spine Surg: Spine Public"},{"key":"4431_CR4","doi-asserted-by":"publisher","first-page":"e15","DOI":"10.1016\/j.wneu.2024.01.156","volume":"187","author":"D Polly","year":"2024","unstructured":"Polly D, Mundis G, Eastlack R et al (2024) Randomized trial of augmented pelvic fixation in patients undergoing thoracolumbar fusion for adult spine deformity: initial results from a multicenter randomized trial. World Neurosurg 187:e15\u2013e27. https:\/\/doi.org\/10.1016\/j.wneu.2024.01.156","journal-title":"World Neurosurg"},{"key":"4431_CR5","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1016\/j.wneu.2017.08.062","volume":"107","author":"M Cox","year":"2017","unstructured":"Cox M, Ng G, Mashriqi F et al (2017) Innervation of the anterior sacroiliac joint. World Neurosurg 107:750\u2013752. https:\/\/doi.org\/10.1016\/j.wneu.2017.08.062","journal-title":"World Neurosurg"},{"issue":"6","key":"4431_CR6","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1111\/j.1469-7580.2012.01564.x","volume":"221","author":"A Vleeming","year":"2012","unstructured":"Vleeming A, Schuenke MD, Masi AT, Carreiro JE, Danneels L, Willard FH (2012) The sacroiliac joint: an overview of its anatomy, function and potential clinical implications. J Anat 221(6):537\u2013567. https:\/\/doi.org\/10.1111\/j.1469-7580.2012.01564.x","journal-title":"J Anat"},{"issue":"2","key":"4431_CR7","doi-asserted-by":"publisher","first-page":"90","DOI":"10.22603\/ssrr.1.2016-0010","volume":"1","author":"E Unoki","year":"2017","unstructured":"Unoki E, Miyakoshi N, Abe E, Kobayashi T, Abe T, Shimada Y (2017) Sacroiliac joint pain after multiple-segment lumbar fusion: a long-term observational study-non-fused sacrum vs. fused sacrum. Spine Surg Relat Res 1(2):90\u201395. https:\/\/doi.org\/10.22603\/ssrr.1.2016-0010","journal-title":"Spine Surg Relat Res"},{"issue":"4","key":"4431_CR8","doi-asserted-by":"publisher","first-page":"334","DOI":"10.2106\/JBJS.17.00052","volume":"100","author":"JN Shillingford","year":"2018","unstructured":"Shillingford JN, Laratta JL, Tan LA et al (2018) The free-hand technique for S2-Alar-Iliac screw placement: a safe and effective method for Sacropelvic fixation in adult spinal deformity. J Bone Joint Surg Am 100(4):334\u2013342. https:\/\/doi.org\/10.2106\/JBJS.17.00052","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"4431_CR9","doi-asserted-by":"publisher","first-page":"86","DOI":"10.3171\/2021.3.SPINE202218","volume":"36","author":"CT Martin","year":"2022","unstructured":"Martin CT, Holton KJ, Jones KE, Sembrano JN, Polly DW (2022) Bilateral open sacroiliac joint fusion during adult spinal deformity surgery using triangular titanium implants: technique description and presentation of 21 cases. J Neurosurg Spine 36(1):86\u201392. https:\/\/doi.org\/10.3171\/2021.3.SPINE202218","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"4431_CR10","doi-asserted-by":"publisher","first-page":"122","DOI":"10.14444\/8387","volume":"17","author":"M Panico","year":"2023","unstructured":"Panico M, Chande RD, Polly DW et al (2023) Effect of Sacropelvic hardware on axis and center of rotation of the sacroiliac joint: a finite element study. Int J Spine Surg. 17(1):122\u2013131. https:\/\/doi.org\/10.14444\/8387","journal-title":"Int J Spine Surg."},{"key":"4431_CR11","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.2147\/JPR.S357076","volume":"15","author":"D Sayed","year":"2022","unstructured":"Sayed D, Khatri N, Rupp A et al (2022) Salvage of failed lateral sacroiliac joint fusion with a novel posterior sacroiliac fusion device: diagnostic approach, surgical technique, and multicenter case Series. J Pain Res 15:1411\u20131420. https:\/\/doi.org\/10.2147\/JPR.S357076","journal-title":"J Pain Res"},{"issue":"1","key":"4431_CR12","doi-asserted-by":"publisher","first-page":"42","DOI":"10.3171\/2021.3.SPINE202175","volume":"36","author":"PB de Andrada","year":"2022","unstructured":"de Andrada PB, Wangsawatwong P, Lehrman JN et al (2022) Biomechanics of a laterally placed sacroiliac joint fusion device supplemental to S2 alar-iliac fixation in a long-segment adult spinal deformity construct: a cadaveric study of stability and strain distribution. J Neurosurg Spine 36(1):42\u201352. https:\/\/doi.org\/10.3171\/2021.3.SPINE202175","journal-title":"J Neurosurg Spine"},{"issue":"7","key":"4431_CR13","doi-asserted-by":"publisher","first-page":"2751","DOI":"10.1007\/s00586-024-08241-6","volume":"33","author":"K Odland","year":"2024","unstructured":"Odland K, Chanbour H, Zuckerman SL, Polly DW (2024) Spinopelvic fixation failure in the adult spinal deformity population: systematic review and meta-analysis. Eur Spine J 33(7):2751\u20132762. https:\/\/doi.org\/10.1007\/s00586-024-08241-6","journal-title":"Eur Spine J"},{"key":"4431_CR14","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/j.jocn.2019.12.058","volume":"72","author":"S Lee","year":"2020","unstructured":"Lee S, Jung SK, Keshen SG, Lewis SJ, Park JH (2020) A distal start point facilitates safer insertion of S2-alar-iliac screws fixation. J Clin Neurosci 72:102\u2013107. https:\/\/doi.org\/10.1016\/j.jocn.2019.12.058","journal-title":"J Clin Neurosci"},{"key":"4431_CR15","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.wneu.2024.06.046","volume":"190","author":"NR Hendrickson","year":"2024","unstructured":"Hendrickson NR, Haselhuhn JJ, Odland K et al (2024) Sacropelvic fixation with porous fusion\/fixation screws: a technical note and retrospective review. World Neurosurg 190:172\u2013180. https:\/\/doi.org\/10.1016\/j.wneu.2024.06.046","journal-title":"World Neurosurg"},{"key":"4431_CR16","doi-asserted-by":"publisher","unstructured":"Holton KJ, Polly DW (2023) SI joint in the elderly. In: Treatment of spine disease in the elderly. Springer, pp 461\u2013471. https:\/\/doi.org\/10.1007\/978-3-031-12612-3_30","DOI":"10.1007\/978-3-031-12612-3_30"},{"issue":"10","key":"4431_CR17","doi-asserted-by":"publisher","first-page":"2587","DOI":"10.1007\/s00586-022-07268-x","volume":"31","author":"TA Sargut","year":"2022","unstructured":"Sargut TA, Hecht N, Xu R et al (2022) Intraoperative imaging and navigated spinopelvic instrumentation: S2-alar-iliac screws combined with tricortical S1 pedicle screw fixation. Eur Spine J 31(10):2587\u20132596. https:\/\/doi.org\/10.1007\/s00586-022-07268-x","journal-title":"Eur Spine J"},{"key":"4431_CR18","doi-asserted-by":"publisher","first-page":"e326","DOI":"10.1016\/j.wneu.2020.08.123","volume":"144","author":"R Tamaki","year":"2020","unstructured":"Tamaki R, Wada K, Okazaki K (2020) Surgical technique and accuracy of S2 Alar-Iliac screw insertion using intraoperative O-arm navigation: an analysis of 120 screws. World Neurosurg 144:e326\u2013e330. https:\/\/doi.org\/10.1016\/j.wneu.2020.08.123","journal-title":"World Neurosurg"},{"issue":"5","key":"4431_CR19","doi-asserted-by":"publisher","first-page":"490","DOI":"10.3171\/2013.2.SPINE12813","volume":"18","author":"WZ Ray","year":"2013","unstructured":"Ray WZ, Ravindra VM, Schmidt MH, Dailey AT (2013) Stereotactic navigation with the O-arm for placement of S-2 alar iliac screws in pelvic lumbar fixation. J Neurosurg Spine 18(5):490\u2013495. https:\/\/doi.org\/10.3171\/2013.2.SPINE12813","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"4431_CR20","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.jspd.2017.08.009","volume":"6","author":"JL Laratta","year":"2018","unstructured":"Laratta JL, Shillingford JN, Lombardi JM et al (2018) Accuracy of S2 alar-iliac screw placement under robotic guidance. Spine Deform 6(2):130\u2013136. https:\/\/doi.org\/10.1016\/j.jspd.2017.08.009","journal-title":"Spine Deform"},{"issue":"21","key":"4431_CR21","doi-asserted-by":"publisher","first-page":"E1297","DOI":"10.1097\/BRS.0000000000002694","volume":"43","author":"JN Shillingford","year":"2018","unstructured":"Shillingford JN, Laratta JL, Park PJ et al (2018) Human versus robot: a propensity-matched analysis of the accuracy of free hand versus robotic guidance for placement of S2 Alar-Iliac (S2AI) Screws. Spine (Phila Pa 1976) 43(21):E1297\u2013E1304. https:\/\/doi.org\/10.1097\/BRS.0000000000002694","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"4431_CR22","doi-asserted-by":"publisher","first-page":"326","DOI":"10.21037\/jss-21-14","volume":"7","author":"NJ Lee","year":"2021","unstructured":"Lee NJ, Khan A, Lombardi JM et al (2021) The accuracy of robot-assisted S2 alar-iliac screw placement at two different healthcare centers. J Spine Surg. 7(3):326\u2013334. https:\/\/doi.org\/10.21037\/jss-21-14","journal-title":"J Spine Surg."},{"issue":"1","key":"4431_CR23","first-page":"89","volume":"41","author":"JE San Miguel-Ruiz","year":"2021","unstructured":"San Miguel-Ruiz JE, Polly D, Albersheim M et al (2021) Is the implant in bone? The accuracy of CT and fluoroscopic imaging for detecting malpositioned pelvic screw and SI fusion implants. Iowa Orthop J 41(1):89\u201394","journal-title":"Iowa Orthop J"},{"key":"4431_CR24","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.wneu.2017.07.154","volume":"109","author":"JP Du","year":"2018","unstructured":"Du JP, Fan Y, Wu QN, Wang DH, Zhang J, Hao DJ (2018) Accuracy of pedicle screw insertion among 3 image-guided navigation systems: systematic review and meta-analysis. World Neurosurg 109:24\u201330. https:\/\/doi.org\/10.1016\/j.wneu.2017.07.154","journal-title":"World Neurosurg"},{"issue":"1","key":"4431_CR25","doi-asserted-by":"publisher","first-page":"495","DOI":"10.2174\/1874325001206010495","volume":"6","author":"L Rudolf","year":"2012","unstructured":"Rudolf L (2012) Sacroiliac joint arthrodesis-MIS technique with titanium implants: report of the First 50 patients and outcomes. Open Orthop J 6(1):495\u2013502. https:\/\/doi.org\/10.2174\/1874325001206010495","journal-title":"Open Orthop J"},{"issue":"6","key":"4431_CR26","doi-asserted-by":"publisher","first-page":"794","DOI":"10.14444\/8543","volume":"17","author":"PG Whang","year":"2023","unstructured":"Whang PG, Patel V, Duhon B et al (2023) Minimally invasive SI joint fusion procedures for chronic SI joint pain: systematic review and meta-analysis of safety and efficacy. Int J Spine Surg 17(6):794\u2013808. https:\/\/doi.org\/10.14444\/8543","journal-title":"Int J Spine Surg"},{"issue":"1","key":"4431_CR27","doi-asserted-by":"publisher","first-page":"E9","DOI":"10.3171\/2022.10.FOCUS22608","volume":"54","author":"SM Comadoll","year":"2023","unstructured":"Comadoll SM, Haselhuhn JJ, Sembrano JN et al (2023) Sacroiliac joint fusion navigation: how accurate is pin placement? Neurosurg Focus 54(1):E9. https:\/\/doi.org\/10.3171\/2022.10.FOCUS22608","journal-title":"Neurosurg Focus"},{"key":"4431_CR28","doi-asserted-by":"publisher","DOI":"10.2147\/MDER.S60370","author":"C Ledonio","year":"2014","unstructured":"Ledonio C, Polly D, Swiontkowski MF, Cummings J (2014) Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion. Med Devices Evid Res. https:\/\/doi.org\/10.2147\/MDER.S60370","journal-title":"Med Devices Evid Res"},{"issue":"1","key":"4431_CR29","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/1750-1164-7-12","volume":"7","author":"J Cummings","year":"2013","unstructured":"Cummings J, Capobianco RA (2013) Minimally invasive sacroiliac joint fusion: one-year outcomes in 18 patients. Ann Surg Innov Res 7(1):12. https:\/\/doi.org\/10.1186\/1750-1164-7-12","journal-title":"Ann Surg Innov Res"},{"issue":"1","key":"4431_CR30","doi-asserted-by":"publisher","first-page":"163","DOI":"10.2174\/1874325001307010163","volume":"7","author":"L Rudolf","year":"2013","unstructured":"Rudolf L (2013) MIS fusion of the SI joint: does prior lumbar spinal fusion affect patient outcomes? Open Orthop J 7(1):163\u2013168. https:\/\/doi.org\/10.2174\/1874325001307010163","journal-title":"Open Orthop J"},{"key":"4431_CR31","doi-asserted-by":"publisher","first-page":"13","DOI":"10.14444\/3013","volume":"10","author":"BS Duhon","year":"2016","unstructured":"Duhon BS, Bitan F, Lockstadt H et al (2016) Triangular titanium implants for minimally invasive sacroiliac joint fusion: 2-year follow-up from a prospective multicenter trial. Int J Spine Surg 10:13. https:\/\/doi.org\/10.14444\/3013","journal-title":"Int J Spine Surg"},{"key":"4431_CR32","doi-asserted-by":"publisher","first-page":"337","DOI":"10.2147\/MDER.S180958","volume":"11","author":"D Cher","year":"2018","unstructured":"Cher D, Wroe K, Reckling WC, Yerby S (2018) Postmarket surveillance of 3D-printed implants for sacroiliac joint fusion. Med Devices (Auckl) 11:337\u2013343. https:\/\/doi.org\/10.2147\/MDER.S180958","journal-title":"Med Devices (Auckl)"},{"issue":"1_suppl","key":"4431_CR33","doi-asserted-by":"publisher","first-page":"s-0036-1583109","DOI":"10.1055\/s-0036-1583109","volume":"6","author":"J Herseth","year":"2016","unstructured":"Herseth J, Ledonio C, Polly DW (2016) A CT-based analysis of implant position of sacroiliac joint fusion: is there a learning curve for safe placement? Global Spine J 6(1_suppl):s-0036-1583109. https:\/\/doi.org\/10.1055\/s-0036-1583109","journal-title":"Global Spine J"},{"issue":"2","key":"4431_CR34","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1111\/os.12453","volume":"11","author":"W Tian","year":"2019","unstructured":"Tian W, Liu Y, Liu B et al (2019) Guideline for thoracolumbar pedicle screw placement assisted by orthopaedic surgical robot. Orthop Surg 11(2):153\u2013159. https:\/\/doi.org\/10.1111\/os.12453","journal-title":"Orthop Surg"},{"key":"4431_CR35","doi-asserted-by":"publisher","first-page":"27","DOI":"10.14444\/1027","volume":"8","author":"MJ Wood","year":"2014","unstructured":"Wood MJ, McMillen J (2014) The surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring\u2014a retrospective review of 627 screws in 150 patients. Int J Spine Surg 8:27. https:\/\/doi.org\/10.14444\/1027","journal-title":"Int J Spine Surg"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-025-04431-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-025-04431-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-025-04431-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T13:42:46Z","timestamp":1767015766000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-025-04431-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,23]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4431"],"URL":"https:\/\/doi.org\/10.1007\/s00590-025-04431-0","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,23]]},"assertion":[{"value":"27 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"None of the authors report a conflict of interest related to the submitted work. CH, JH, PBS, and JL have nothing to disclose. DWP declares consulting fees from Globus Medical and Alexion; institutional grant\/research support from Medtronic and Mizuho OSI; consulting fees, royalties, and honoraria from SI Bone; and royalties from Springer. CJM reports paid consultancy for Medtronic and institutional research support from Stryker, Medtronic, and SI-Bone. JS declares institutional grant\/research support from Mizuho OSI, NuVasive, Orthofix, and SI Bone. KJ reports paid consultancy for SI-Bone and Medtronic, and institutional research support from Stryker, Medtronic and SI-Bone. NH has consultancies with Medtronic. The authors did not receive support from any organization for the submitted work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"317"}}