{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T01:27:15Z","timestamp":1783733235759,"version":"3.55.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T00:00:00Z","timestamp":1779408000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T00:00:00Z","timestamp":1779408000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Orthop Surg Traumatol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Fibular non-union occurs at an unknown rate in patients with tibial shaft fractures. The purpose of this study was to assess the rate of fibular non-union in patients with tibial shaft fractures. We also assessed if any factors are associated with the rate of fibular non-union.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This was an Institutional Review Board (IRB) approved retrospective cohort study performed at a level one trauma center. We reviewed the collected data on 400 patients that had fibular fractures with associated tibial shaft fractures from June 2012 to June 2021. To meet the inclusion criteria for this study, patients 16 years and older needed a minimum of three months of follow-up and sustained fibular fractures with associated tibial shaft fractures fix with an intramedullary rod. The standard and modified radiographic union scale in tibia (RUST and mRUST) fractures score of 8 was used as the parameter to determine fibular union.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The rate of fibular non-union was 21% (84\/400). Distal 1\/3 fibular fractures had a higher non-union rate (25%, 46\/179) than proximal and middle 1\/3 fractures (12%, 10\/83; 20%, 28\/138 respectively) (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.036). Patients that had fibular fixation went on to form a non-union at a rate of 25% (31\/121) and patients that did not have fibular fixation went on to form non-union at a rate of 19% (52\/279) (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.114). Of the patients that did have fibular fixation, those fixed with intramedullary flexible nail (IMFN) or screw are less likely to form a non-union than those fixed with plates (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.049).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This study identified the rate of fibular non-union in patients with associated tibial shaft fractures treated with an intramedullary rod. We also identified that there is an increased risk of non-union when there is fibular fixation with plates and screws versus IMFN. We do not know the clinical implications of this, but it may be a source of pain in patients with healed tibia shaft fractures therefore we believe a prospective randomized controlled study may be warranted.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00590-026-04711-3","type":"journal-article","created":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T06:59:33Z","timestamp":1779433173000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Rate of fibular non-union in patients with tibial shaft fractures: a retrospective cohort study"],"prefix":"10.1007","volume":"36","author":[{"given":"W. Andrew","family":"Day","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"II","given":"C. Julian","family":"Clark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johnathan W.","family":"Riley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Drew P.","family":"Melancon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"III","given":"Isaac J.","family":"Spears","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. C.","family":"Davidson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauren","family":"Hopper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Peyton","family":"Parker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priyanka","family":"Nehete","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter N.","family":"Mittwede","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick F.","family":"Bergin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,22]]},"reference":[{"issue":"1","key":"4711_CR1","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1097\/00005373-199101000-00018","volume":"31","author":"O B\u00f6stman","year":"1991","unstructured":"B\u00f6stman O, Kyr\u00f6 A (1991) Delayed union of fibular fractures accompanying fractures of the tibial shaft. J Trauma 31(1):99\u2013102. https:\/\/doi.org\/10.1097\/00005373-199101000-00018","journal-title":"J Trauma"},{"issue":"184","key":"4711_CR2","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1097\/00003086-198404000-00047","volume":"184","author":"K Takebe","year":"1984","unstructured":"Takebe K, Nakagawa A, Minami H, Kanazawa H Hirohata K (1984) Role of the fibula in weight-bearing. Clin Orthop Relat Res 184:289\u2013292","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"4711_CR3","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1007\/s00264-012-1556-z","volume":"36","author":"AK Bhadra","year":"2012","unstructured":"Bhadra AK, Roberts CS, Giannoudis PV (2012) Non-union of fibula: a systematic review. Int Orthop 36(9):1757\u20131765. https:\/\/doi.org\/10.1007\/s00264-012-1556-z","journal-title":"Int Orthop"},{"issue":"3","key":"4711_CR4","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1097\/BOT.0b013e31825cf78a","volume":"27","author":"SB Ko","year":"2013","unstructured":"Ko SB, Lee SW (2013) Do fibula non-unions predict later tibia non-unions? J Orthop Trauma 27(3):150\u2013152. https:\/\/doi.org\/10.1097\/BOT.0b013e31825cf78a","journal-title":"J Orthop Trauma"},{"issue":"5","key":"4711_CR5","doi-asserted-by":"publisher","first-page":"704","DOI":"10.4055\/cios23036","volume":"15","author":"J-W Lee","year":"2023","unstructured":"Lee J-W, Byun S-E, Kim Y-W, Byun Y-S, Yoon Y-C, Sohn H-S (2023) Fibular fixation in same-level distal third tibiofibular fractures: is fibular fracture regarded as a secondary importance? Clin Orthop Surg 15(5):704. https:\/\/doi.org\/10.4055\/cios23036","journal-title":"Clin Orthop Surg"},{"issue":"Suppl 4","key":"4711_CR6","doi-asserted-by":"publisher","first-page":"S22","DOI":"10.1097\/BOT.0000000000000695","volume":"30","author":"D Torino","year":"2016","unstructured":"Torino D, Mehta S (2016) Fibular fixation in distal tibia fractures: reduction aid or non-union generator? J Orthop Trauma 30(Suppl 4):S22\u2013S5. https:\/\/doi.org\/10.1097\/BOT.0000000000000695","journal-title":"J Orthop Trauma"},{"issue":"7","key":"4711_CR7","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/j.fas.2021.11.007","volume":"28","author":"RG Kim","year":"2022","unstructured":"Kim RG, An VVG, Petchell JF (2022) Fibular fixation in mid and distal extra-articular tibia fractures - A systematic review and meta-analysis. Foot Ankle Surg 28(7):809\u2013816. https:\/\/doi.org\/10.1016\/j.fas.2021.11.007","journal-title":"Foot Ankle Surg"},{"issue":"2","key":"4711_CR8","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1053\/j.jfas.2022.09.003","volume":"62","author":"TT McClure","year":"2023","unstructured":"McClure TT, Taylor BC, Huber G, Glazier M, Myers DM, DeGenova DT (2023) Intramedullary screw fixation versus traditional plating for distal fibula fractures. J Foot Ankle Surg 62(2):355\u2013359. https:\/\/doi.org\/10.1053\/j.jfas.2022.09.003","journal-title":"J Foot Ankle Surg"},{"issue":"7","key":"4711_CR9","doi-asserted-by":"publisher","first-page":"e24","DOI":"10.5435\/JAAOSGlobal-D-24-00119","volume":"8","author":"Z Samuel","year":"2024","unstructured":"Samuel Z, Hong IS, Deliso M, Passannante L, Zapf CG, Tang A et al (2024) Intramedullary fixation versus plate fixation of distal fibular fractures: a systematic review. J Am Acad Orthop Surg Glob Res Rev 8(7):e24. https:\/\/doi.org\/10.5435\/JAAOSGlobal-D-24-00119","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"4711_CR10","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.jcot.2021.04.020","volume":"18","author":"HC B\u00e4cker","year":"2021","unstructured":"B\u00e4cker HC, Vosseller JT (2021) Intramedullary fixation of fibula fractures: a systematic review. J Clin Orthop Trauma 18:136\u2013143. https:\/\/doi.org\/10.1016\/j.jcot.2021.04.020","journal-title":"J Clin Orthop Trauma"},{"issue":"2","key":"4711_CR11","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.injury.2013.09.017","volume":"45","author":"M Berlusconi","year":"2014","unstructured":"Berlusconi M, Busnelli L, Chiodini F, Portinaro N (2014) To fix or not to fix? The role of fibular fixation in distal shaft fractures of the leg. Injury 45(2):408\u2013411. https:\/\/doi.org\/10.1016\/j.injury.2013.09.017","journal-title":"Injury"},{"key":"4711_CR12","volume-title":"EPIC Hyperspace. November 2023","author":"The EPIC Team","year":"1979","unstructured":"The EPIC Team (1979) EPIC Hyperspace. November 2023. Epic Systems Corporation, Verona, WI"},{"issue":"3","key":"4711_CR13","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1097\/TA.0b013e3181a7c16d","volume":"68","author":"DB Whelan","year":"2010","unstructured":"Whelan DB, Bhandari M, Stephen D, Kreder H, McKee MD, Zdero R et al (2010) Development of the radiographic union score for tibial fractures for the assessment of tibial fracture healing after intramedullary fixation. J Trauma 68(3):629\u2013632. https:\/\/doi.org\/10.1097\/TA.0b013e3181a7c16d","journal-title":"J Trauma"},{"issue":"11","key":"4711_CR14","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1097\/BOT.0000000000000390","volume":"29","author":"J Litrenta","year":"2015","unstructured":"Litrenta J, Tornetta P, Mehta S, Jones C, O\u2019Toole RV, Bhandari M et al (2015) Determination of radiographic healing: an assessment of consistency using RUST and modified RUST in metadiaphyseal fractures. J Orthop Trauma 29(11):516\u2013520. https:\/\/doi.org\/10.1097\/BOT.0000000000000390","journal-title":"J Orthop Trauma"},{"issue":"7","key":"4711_CR15","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1016\/j.fas.2021.12.007","volume":"28","author":"CC Hong","year":"2022","unstructured":"Hong CC, Tan SHS, Saha S, Pearce CJ (2022) Fibula fixation in the treatment of tibial pilon fractures\u2014is it really necessary? Foot Ankle Surg 28(7):891\u2013897. https:\/\/doi.org\/10.1016\/j.fas.2021.12.007","journal-title":"Foot Ankle Surg"},{"issue":"Suppl 1","key":"4711_CR16","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1016\/j.injury.2007.02.005","volume":"38","author":"M Jagodzinski","year":"2007","unstructured":"JagodzinskiM, Krettek C (2007) Effect of mechanical stability on fracture healing\u2013an update. Injury 38(Suppl 1):S3\u2013S10. https:\/\/doi.org\/10.1016\/j.injury.2007.02.005","journal-title":"Injury"},{"issue":"10","key":"4711_CR17","doi-asserted-by":"publisher","first-page":"711","DOI":"10.5435\/JAAOS-D-15-00175","volume":"24","author":"MJ Beltran","year":"2016","unstructured":"Beltran MJ, Collinge CA, Gardner MJ (2016) Stress modulation of fracture fixation implants. J Am Acad Orthop Surg 24(10):711\u2013719. https:\/\/doi.org\/10.5435\/JAAOS-D-15-00175","journal-title":"J Am Acad Orthop Surg"},{"issue":"Suppl 1","key":"4711_CR18","doi-asserted-by":"publisher","first-page":"S12","DOI":"10.1097\/BOT.0000000000001124","volume":"32","author":"BL Norris","year":"2018","unstructured":"Norris BL, Lang G, Russell TAT, Rothberg DL, Ricci WM, Borrelli J (2018) Absolute versus relative fracture fixation: impact on fracture healing. J Orthop Trauma 32(Suppl 1):S12\u2013S6. https:\/\/doi.org\/10.1097\/BOT.0000000000001124","journal-title":"J Orthop Trauma"},{"key":"4711_CR19","doi-asserted-by":"publisher","first-page":"678","DOI":"10.3389\/fphys.2016.00678","volume":"7","author":"V Glatt","year":"2017","unstructured":"Glatt V, Evans CH, Tetsworth K (2017) A concert between biology and biomechanics: the influence of the mechanical environment on bone healing. Front Physiol 7:678. https:\/\/doi.org\/10.3389\/fphys.2016.00678","journal-title":"Front Physiol"},{"issue":"7","key":"4711_CR20","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.injury.2006.07.041","volume":"38","author":"M Ahmed","year":"2007","unstructured":"Ahmed M, Wimhurst JA, Walton NP (2007) Non-union of Weber B fractures: a case series. Injury 38(7):861\u2013864. https:\/\/doi.org\/10.1016\/j.injury.2006.07.041","journal-title":"Injury"}],"container-title":["European Journal of Orthopaedic Surgery &amp; Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-026-04711-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00590-026-04711-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00590-026-04711-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,22]],"date-time":"2026-05-22T06:59:36Z","timestamp":1779433176000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00590-026-04711-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,22]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4711"],"URL":"https:\/\/doi.org\/10.1007\/s00590-026-04711-3","relation":{},"ISSN":["1432-1068"],"issn-type":[{"value":"1432-1068","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,22]]},"assertion":[{"value":"16 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"199"}}