{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,4,5]],"date-time":"2022-04-05T03:01:56Z","timestamp":1649127716018},"reference-count":6,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2012,12,13]],"date-time":"2012-12-13T00:00:00Z","timestamp":1355356800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Surg Today"],"published-print":{"date-parts":[[2013,6]]},"DOI":"10.1007\/s00595-012-0453-9","type":"journal-article","created":{"date-parts":[[2012,12,12]],"date-time":"2012-12-12T14:27:06Z","timestamp":1355322426000},"page":"705-707","source":"Crossref","is-referenced-by-count":2,"title":["The one-knot technique: a simple modification of the loop technique for mitral valve repair"],"prefix":"10.1007","volume":"43","author":[{"given":"Taichi","family":"Sakaguchi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Nishi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shigeru","family":"Miyagawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasushi","family":"Yoshikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satsuki","family":"Fukushima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Yoshioka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayoshi","family":"Ueno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiki","family":"Sawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,12,13]]},"reference":[{"key":"453_CR1","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.ejcts.2008.01.013","volume":"33","author":"T Kuntze","year":"2008","unstructured":"Kuntze T, Borger MA, Falk V, et al. Early and mid-term results of mitral valve repair using premeasured Gore-Tex loops (\u2018loop technique\u2019). Eur J Cardiothorac Surg. 2008;33:566\u201372.","journal-title":"Eur J Cardiothorac Surg"},{"key":"453_CR2","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1016\/j.jtcvs.2008.07.028","volume":"136","author":"N Falk","year":"2008","unstructured":"Falk N, Seeburger J, Vzesla M, et al. How does the use of polytetrafluoroethylene neochordae for posterior mitral valve prolapse (loop technique) compare with leaflet resection? A prospective randomized trial. J Thorac Cardiovasc Surg. 2008;136:1200\u20136.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"453_CR3","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1016\/j.athoracsur.2009.03.003","volume":"87","author":"J Seeburger","year":"2009","unstructured":"Seeburger J, Falk V, Borger MA, et al. Chordae replacement versus resection al for repair of isolated posteior mitral leaflet prolaspse: a Egalite. Ann Thorac Surg. 2009;87:1715\u201320.","journal-title":"Ann Thorac Surg"},{"key":"453_CR4","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/0003-4975(94)90413-8","volume":"57","author":"H Kasegawa","year":"1994","unstructured":"Kasegawa H, Kamata S, Hirata S, et al. Simple method for determining proper length of artificial chordae in mitral valve repair. Ann Thorac Surg. 1994;57:237\u20139.","journal-title":"Ann Thorac Surg"},{"key":"453_CR5","doi-asserted-by":"crossref","first-page":"2166","DOI":"10.1016\/S0003-4975(00)02047-6","volume":"70","author":"UO Oppell von","year":"2000","unstructured":"von Oppell UO, Mohr FW. Chordal replacement for both minimally invasive and conventional mitral valve surgery using premeasured Gore-Tex loops. Ann Thorac Surg. 2000;70:2166\u20138.","journal-title":"Ann Thorac Surg"},{"key":"453_CR6","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.athoracsur.2008.04.066","volume":"87","author":"M Kudo","year":"2009","unstructured":"Kudo M, Yozu R, Kokaji K, Kimura N. A simple method of prevention of systolic anterior motion in mitral valve repair by loop technique method. Ann Thorac Surg. 2009;87:324\u20135.","journal-title":"Ann Thorac Surg"}],"container-title":["Surgery Today"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00595-012-0453-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00595-012-0453-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00595-012-0453-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T14:05:26Z","timestamp":1559138726000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00595-012-0453-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12,13]]},"references-count":6,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,6]]}},"alternative-id":["453"],"URL":"https:\/\/doi.org\/10.1007\/s00595-012-0453-9","relation":{},"ISSN":["0941-1291","1436-2813"],"issn-type":[{"value":"0941-1291","type":"print"},{"value":"1436-2813","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,12,13]]}}}