{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T02:19:37Z","timestamp":1772849977943,"version":"3.50.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2010,7,4]],"date-time":"2010-07-04T00:00:00Z","timestamp":1278201600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"published-print":{"date-parts":[[2010,10]]},"DOI":"10.1007\/s00701-010-0724-4","type":"journal-article","created":{"date-parts":[[2010,7,3]],"date-time":"2010-07-03T18:45:29Z","timestamp":1278182729000},"page":"1793-1800","source":"Crossref","is-referenced-by-count":8,"title":["Miethke DualSwitch Valve in lumboperitoneal shunts"],"prefix":"10.1007","volume":"152","author":[{"given":"Suhas","family":"Udayakumaran","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Roth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anat","family":"Kesler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shlomi","family":"Constantini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,7,4]]},"reference":[{"key":"724_CR1","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1055\/s-2008-1065337","volume":"51","author":"F Hertel","year":"2008","unstructured":"Hertel F, Zuchner M, Decker C, Schill S, Bosniak I, Bettag M (2008) The Miethke dual switch valve: experience in 169 adult patients with different kinds of hydrocephalus: an open field study. Minim Invasive Neurosurg 51:147\u2013153","journal-title":"Minim Invasive Neurosurg"},{"key":"724_CR2","doi-asserted-by":"crossref","first-page":"568","DOI":"10.3171\/jns.1993.78.4.0568","volume":"78","author":"PD Chumas","year":"1993","unstructured":"Chumas PD, Armstrong DC, Drake JM, Kulkarni AV, Hoffman HJ, Humphreys RP, Rutka JT, Hendrick EB (1993) Tonsillar herniation: the rule rather than the exception after lumboperitoneal shunting in the pediatric population. J Neurosurg 78:568\u2013573","journal-title":"J Neurosurg"},{"key":"724_CR3","first-page":"e8","volume":"7","author":"CC Chang","year":"1999","unstructured":"Chang CC, Kuwana N, Ito S (1999) Management of patients with normal-pressure hydrocephalus by using lumboperitoneal shunt system with the Codman Hakim programmable valve. Neurosurg Focus 7:e8","journal-title":"Neurosurg Focus"},{"key":"724_CR4","doi-asserted-by":"crossref","first-page":"19","DOI":"10.3171\/PED\/2008\/2\/7\/019","volume":"2","author":"TD Nadkarni","year":"2008","unstructured":"Nadkarni TD, Rekate HL, Wallace D (2008) Concurrent use of a lumboperitoneal shunt with programmable valve and ventricular access device in the treatment of pseudotumor cerebri: review of 40 cases. J Neurosurg Pediatr 2:19\u201324","journal-title":"J Neurosurg Pediatr"},{"key":"724_CR5","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1227\/01.NEU.0000255469.68129.81","volume":"60","author":"VY Wang","year":"2007","unstructured":"Wang VY, Barbaro NM, Lawton MT, Pitts L, Kunwar S, Parsa AT, Gupta N, McDermott MW (2007) Complications of lumboperitoneal shunts. Neurosurgery 60:1045\u20131048, discussion 1049","journal-title":"Neurosurgery"},{"key":"724_CR6","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.surneu.2003.05.003","volume":"61","author":"U Meier","year":"2004","unstructured":"Meier U, Kiefer M, Sprung C (2004) Evaluation of the Miethke dual- switch valve in patients with normal pressure hydrocephalus. Surg Neurol 61:119\u2013127, discussion 127-118","journal-title":"Surg Neurol"},{"issue":"Suppl 1","key":"724_CR7","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1055\/s-2008-1071248","volume":"8","author":"C Sprung","year":"1998","unstructured":"Sprung C, Miethke C, Shakeri K, Lanksch WR (1998) Pitfalls in shunting of hydrocephalus\u2013clinical reality and improvement by the hydrostatic dual-switch valve. Eur J Pediatr Surg 8(Suppl 1):26\u201330","journal-title":"Eur J Pediatr Surg"},{"key":"724_CR8","first-page":"360","volume":"71","author":"HA Trost","year":"1998","unstructured":"Trost HA, Sprung C, Lanksch W, Stolke D, Miethke C (1998) Dual-switch valve: clinical performance of a new hydrocephalus valve. Acta Neurochir Suppl 71:360\u2013363","journal-title":"Acta Neurochir Suppl"},{"key":"724_CR9","doi-asserted-by":"crossref","first-page":"403","DOI":"10.2176\/nmc.47.403","volume":"47","author":"A Tsunoda","year":"2007","unstructured":"Tsunoda A, Maruki C (2007) Clinical experience with a dual switch valve (Miethke) for the management of adult hydrocephalus. Neurol Med Chir (Tokyo) 47:403\u2013408, discussion 408","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"724_CR10","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1055\/s-2000-10997","volume":"61","author":"U Meier","year":"2000","unstructured":"Meier U, Zeilinger FS, Reyer T, Kintzel D (2000) Clinical experience with various shunt systems in normal pressure hydrocephalus. Zentralbl Neurochir 61:143\u2013149","journal-title":"Zentralbl Neurochir"},{"key":"724_CR11","doi-asserted-by":"crossref","first-page":"770","DOI":"10.3171\/jns.1975.43.6.0770","volume":"43","author":"RF Spetzler","year":"1975","unstructured":"Spetzler RF, Wilson CB, Grollmus JM (1975) Percutaneous lumboperitoneal shunt Technical note. J Neurosurg 43:770\u2013773","journal-title":"J Neurosurg"},{"key":"724_CR12","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1227\/00006123-198003000-00005","volume":"6","author":"WR Selman","year":"1980","unstructured":"Selman WR, Spetzler RF, Wilson CB, Grollmus JW (1980) Percutaneous lumboperitoneal shunt: review of 130 cases. Neurosurgery 6:255\u2013257","journal-title":"Neurosurgery"},{"key":"724_CR13","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1212\/WNL.49.3.734","volume":"49","author":"RA Burgett","year":"1997","unstructured":"Burgett RA, Purvin VA, Kawasaki A (1997) Lumboperitoneal shunting for pseudotumor cerebri. Neurology 49:734\u2013739","journal-title":"Neurology"},{"key":"724_CR14","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1227\/00006123-199303000-00007","volume":"32","author":"PD Chumas","year":"1993","unstructured":"Chumas PD, Kulkarni AV, Drake JM, Hoffman HJ, Humphreys RP, Rutka JT (1993) Lumboperitoneal shunting: a retrospective study in the pediatric population. Neurosurgery 32:376\u2013383, discussion 383","journal-title":"Neurosurgery"},{"key":"724_CR15","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1227\/00006123-199006000-00013","volume":"26","author":"N Aoki","year":"1990","unstructured":"Aoki N (1990) Lumboperitoneal shunt: clinical applications, complications, and comparison with ventriculoperitoneal shunt. Neurosurgery 26:998\u20131003, discussion 1003\u20131004","journal-title":"Neurosurgery"},{"key":"724_CR16","doi-asserted-by":"crossref","first-page":"875","DOI":"10.3171\/jns.1992.77.6.0875","volume":"77","author":"M Choux","year":"1992","unstructured":"Choux M, Genitori L, Lang D, Lena G (1992) Shunt implantation: Reducing the incidence Of shunt infection. J Neurosurg 77:875\u2013880","journal-title":"J Neurosurg"},{"key":"724_CR17","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1007\/s00701-004-0392-3","volume":"146","author":"K Karabatsou","year":"2004","unstructured":"Karabatsou K, Quigley G, Buxton N, Foy P, Mallucci C (2004) Lumboperitoneal shunts: are the complications acceptable? Acta Neurochir (Wien) 146:1193\u20131197","journal-title":"Acta Neurochir (Wien)"},{"key":"724_CR18","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1159\/000083739","volume":"40","author":"L Khorasani","year":"2004","unstructured":"Khorasani L, Sikorski CW, Frim DM (2004) Lumbar CSF shunting preferentially drains the cerebral subarachnoid over the ventricular spaces: implications for the treatment of slit ventricle syndrome. Pediatr Neurosurg 40:270\u2013276","journal-title":"Pediatr Neurosurg"},{"key":"724_CR19","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1212\/WNL.46.6.1524","volume":"46","author":"ER Eggenberger","year":"1996","unstructured":"Eggenberger ER, Miller NR, Vitale S (1996) Lumboperitoneal shunt for the treatment of pseudotumor cerebri. Neurology 46:1524\u20131530","journal-title":"Neurology"},{"key":"724_CR20","doi-asserted-by":"crossref","first-page":"627","DOI":"10.3171\/jns.2004.101.4.0627","volume":"101","author":"MJ McGirt","year":"2004","unstructured":"McGirt MJ, Woodworth G, Thomas G, Miller N, Williams M, Rigamonti D (2004) Cerebrospinal fluid shunt placement for pseudotumor cerebri-associated intractable headache: predictors of treatment response and an analysis of long-term outcomes. J Neurosurg 101:627\u2013632","journal-title":"J Neurosurg"},{"key":"724_CR21","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1212\/WNL.43.6.1071","volume":"43","author":"ML Rosenberg","year":"1993","unstructured":"Rosenberg ML, Corbett JJ, Smith C, Goodwin J, Sergott R, Savino P, Schatz N (1993) Cerebrospinal fluid diversion procedures in pseudotumor cerebri. Neurology 43:1071\u20131072","journal-title":"Neurology"},{"key":"724_CR22","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s00381-001-0544-1","volume":"18","author":"AA Virella","year":"2002","unstructured":"Virella AA, Galarza M, Masterman-Smith M, Lemus R, Lazareff JA (2002) Distal slit valve and clinically relevant CSF overdrainage in children with hydrocephalus. Childs Nerv Syst 18:15\u201318","journal-title":"Childs Nerv Syst"},{"key":"724_CR23","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1159\/000067562","volume":"38","author":"HL Rekate","year":"2003","unstructured":"Rekate HL, Wallace D (2003) Lumboperitoneal shunts in children. Pediatr Neurosurg 38:41\u201346","journal-title":"Pediatr Neurosurg"},{"key":"724_CR24","volume-title":"In-vitro-Testung von Hydrocephalus-Ventilen","author":"A Aschoff","year":"1994","unstructured":"Aschoff A (1994) In-vitro-Testung von Hydrocephalus-Ventilen. University of Heidelberg, Habilitation"},{"key":"724_CR25","doi-asserted-by":"crossref","first-page":"R51","DOI":"10.1088\/0967-3334\/25\/5\/R01","volume":"25","author":"M Czosnyka","year":"2004","unstructured":"Czosnyka M, Czosnyka Z, Momjian S, Pickard JD (2004) Cerebrospinal fluid dynamics. Physiol Meas 25:R51\u2013R76","journal-title":"Physiol Meas"},{"key":"724_CR26","first-page":"334","volume":"71","author":"Z Czosnyka","year":"1998","unstructured":"Czosnyka Z, Czosnyka M, Richards H, Pickard JD (1998) Hydrodynamic properties of hydrocephalus shunts. Acta Neurochir Suppl 71:334\u2013339","journal-title":"Acta Neurochir Suppl"},{"key":"724_CR27","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/00006123-199802000-00069","volume":"42","author":"Z Czosnyka","year":"1998","unstructured":"Czosnyka Z, Czosnyka M, Richards HK, Pickard JD (1998) Posture-related overdrainage: comparison of the performance of 10 hydrocephalus shunts in vitro. Neurosurgery 42:327\u2013333, discussion 333-324","journal-title":"Neurosurgery"},{"key":"724_CR28","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1017\/S0317167100006119","volume":"34","author":"FC Lam","year":"2007","unstructured":"Lam FC, Wheatley MB, Mehta V (2007) Treatment of secondary tonsillar herniation by lumboperitoneal shunt revision. Can J Neurol Sci 34:237\u2013242","journal-title":"Can J Neurol Sci"},{"key":"724_CR29","doi-asserted-by":"crossref","first-page":"750","DOI":"10.3171\/jns.2001.94.5.0750","volume":"94","author":"B Lundkvist","year":"2001","unstructured":"Lundkvist B, Eklund A, Kristensen B, Fagerlund M, Koskinen LO, Malm J (2001) Cerebrospinal fluid hydrodynamics after placement of a shunt with an antisiphon device: a long-term study. J Neurosurg 94:750\u2013756","journal-title":"J Neurosurg"},{"key":"724_CR30","unstructured":"Nissels R, inventor; Johnson & johnson Professional, Inc., assignee (1997) Fluid flow limiting device. US patent 6,126,628"},{"key":"724_CR31","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/BF00277653","volume":"11","author":"A Aschoff","year":"1995","unstructured":"Aschoff A, Kremer P, Benesch C, Fruh K, Klank A, Kunze S (1995) Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices. Childs Nerv Syst 11:193\u2013202","journal-title":"Childs Nerv Syst"},{"key":"724_CR32","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1080\/02688690120057637","volume":"15","author":"G Zemack","year":"2001","unstructured":"Zemack G, Romner B (2001) Do adjustable shunt valves pressure our budget? A retrospective analysis of 541 implanted Codman Hakim programmable valves. Br J Neurosurg 15:221\u2013227","journal-title":"Br J Neurosurg"},{"key":"724_CR33","doi-asserted-by":"crossref","first-page":"289","DOI":"10.3171\/2009.4.PEDS08204","volume":"4","author":"EJ Haberl","year":"2009","unstructured":"Haberl EJ, Messing-Juenger M, Schuhmann M, Eymann R, Cedzich C, Fritsch MJ, Kiefer M, Van Lindert EJ, Geyer C, Lehner M, Rohde V, Stroux A, von Berenberg P (2009) Experiences with a gravity-assisted valve in hydrocephalic children. J Neurosurg Pediatr 4:289\u2013294","journal-title":"J Neurosurg Pediatr"},{"key":"724_CR34","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1227\/01.NEU.0000134596.66114.E7","volume":"57","author":"M Kiefer","year":"2005","unstructured":"Kiefer M, Eymann R, Strowitzki M, Steudel WI (2005) Gravitational shunts in longstanding overt ventriculomegaly in adults. Neurosurgery 57:109\u2013119","journal-title":"Neurosurgery"},{"key":"724_CR35","doi-asserted-by":"crossref","first-page":"90","DOI":"10.3171\/2008.11.PEDS08154","volume":"3","author":"V Rohde","year":"2009","unstructured":"Rohde V, Haberl EJ, Ludwig H, Thomale UW (2009) First experiences with an adjustable gravitational valve in childhood hydrocephalus. J Neurosurg Pediatr 3:90\u201393","journal-title":"J Neurosurg Pediatr"},{"key":"724_CR36","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1007\/s00381-002-0577-0","volume":"18","author":"U Meier","year":"2002","unstructured":"Meier U, Kintzel D (2002) Clinical experiences with different valve systems in patients with normal-pressure hydrocephalus: evaluation of the Miethke dual-switch valve. Childs Nerv Syst 18:288\u2013294","journal-title":"Childs Nerv Syst"},{"key":"724_CR37","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1097\/00006123-199804000-00160","volume":"42","author":"A Aschoff","year":"1998","unstructured":"Aschoff A, Kremer P (1998) Determining the best cerebrospinal fluid shunt valve design: the pediatric valve design trial. Neurosurgery 42:949\u2013951","journal-title":"Neurosurgery"},{"key":"724_CR38","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1515\/bmte.1994.39.7-8.181","volume":"39","author":"C Miethke","year":"1994","unstructured":"Miethke C, Affeld K (1994) A new valve for the treatment of hydrocephalus. Biomed Tech (Berl, Z) 39:181\u2013187","journal-title":"Biomed Tech (Berl., Z.)"},{"key":"724_CR39","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/BF00261650","volume":"12","author":"C Sprung","year":"1996","unstructured":"Sprung C, Miethke C, Trost HA, Lanksch WR, Stolke D (1996) The dual-switch valve. A new hydrostatic valve for the treatment of hydrocephalus. Childs Nerv Syst 12:573\u2013581","journal-title":"Childs Nerv Syst"},{"key":"724_CR40","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/978-3-642-77997-8_19","volume":"21","author":"A Aschoff","year":"1993","unstructured":"Aschoff A, Benesch C, Kremer R, Haken MS, Klank A, Osterloh M, Fruh K (1993) The solved and unsolved problems of hydrocephalus valves: a critical comment. Adv Neurosurg 21:103\u2013114","journal-title":"Adv Neurosurg"},{"key":"724_CR41","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1159\/000120722","volume":"19","author":"C Sainte-Rose","year":"1993","unstructured":"Sainte-Rose C (1993) Shunt obstruction.A preventable complication? Pediatr Neurosurg 19:156\u2013164","journal-title":"Pediatr Neurosurg"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-010-0724-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00701-010-0724-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-010-0724-4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T04:16:27Z","timestamp":1559103387000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00701-010-0724-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,4]]},"references-count":41,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2010,10]]}},"alternative-id":["724"],"URL":"https:\/\/doi.org\/10.1007\/s00701-010-0724-4","relation":{},"ISSN":["0001-6268","0942-0940"],"issn-type":[{"value":"0001-6268","type":"print"},{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7,4]]}}}