{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T12:26:33Z","timestamp":1793190393813,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,1,15]],"date-time":"2016-01-15T00:00:00Z","timestamp":1452816000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1007\/s00701-016-2705-8","type":"journal-article","created":{"date-parts":[[2016,1,15]],"date-time":"2016-01-15T12:53:53Z","timestamp":1452862433000},"page":"465-471","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":94,"title":["Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation?"],"prefix":"10.1007","volume":"158","author":[{"given":"Keitaro","family":"Matsukawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiyuki","family":"Yato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideaki","family":"Imabayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naobumi","family":"Hosogane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichiro","family":"Abe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Asazuma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiro","family":"Chiba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,1,15]]},"reference":[{"key":"2705_CR1","doi-asserted-by":"crossref","first-page":"E1297","DOI":"10.1097\/BRS.0000000000000553","volume":"39","author":"DA Baluch","year":"2014","unstructured":"Baluch DA, Patel AA, Lullo B, Havey RM, Voronov LI, Nguyen NL, Carandang G, Ghanayem AJ, Patwardhan AG (2014) Effect of physiological loads on cortical and traditional pedicle screw fixation. Spine 39:E1297\u2013E1302","journal-title":"Spine"},{"key":"2705_CR2","author":"RJ Bianco","year":"2014","unstructured":"Bianco RJ, Arnoux PJ, Wagnac E, Mac-Thiong JM, Aubin C\u0114 (2014) Minimizing pedicle screw pullout risks: a detailed biomechanical analysis of screw design and placement. J Spinal Disord Tech. doi: 10.1097\/BSD.0000000000000151","journal-title":"J Spinal Disord Tech"},{"key":"2705_CR3","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1097\/00007632-199408000-00016","volume":"19","author":"AG Brantley","year":"1994","unstructured":"Brantley AG, Mayfield JK, Koeneman JB, Clark KR (1994) The effects of pedicle screw fit: an in vitro study. Spine 19:1752\u20131758","journal-title":"Spine"},{"key":"2705_CR4","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/S1350-4533(02)00219-9","volume":"25","author":"SI Chen","year":"2003","unstructured":"Chen SI, Lin RM, Chang CH (2003) Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions. Med Eng Phys 25:275\u2013282","journal-title":"Med Eng Phys"},{"key":"2705_CR5","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1097\/00007632-199407000-00014","volume":"19","author":"KMC Cheung","year":"1994","unstructured":"Cheung KMC, Ruan D, Chan FL, Fang D (1994) Computed tomographic osteometry of asian lumbar pedicle. Spine 19:1495\u20131498","journal-title":"Spine"},{"key":"2705_CR6","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","volume":"19","author":"TL Halvorson","year":"1994","unstructured":"Halvorson TL, Kelly LA, Thomas KA, Whitecloud TS III, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine 19:2415\u20132420","journal-title":"Spine"},{"key":"2705_CR7","doi-asserted-by":"crossref","first-page":"2504","DOI":"10.1097\/00007632-199711010-00007","volume":"22","author":"T Hirano","year":"1997","unstructured":"Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T, Sugiura T, Yokaichi M, Ikeda M (1997) Structural characteristics of the pedicle and its role in screw stability. Spine 22:2504\u20132510","journal-title":"Spine"},{"key":"2705_CR8","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1016\/j.orthres.2004.11.002","volume":"23","author":"CC Hsu","year":"2005","unstructured":"Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J (2005) Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 23:788\u2013794","journal-title":"J Orthop Res"},{"key":"2705_CR9","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1097\/01.brs.0000225993.57349.df","volume":"31","author":"K Imai","year":"2006","unstructured":"Imai K, Ohnishi I, Bessho M, Nakamura K (2006) Nonlinear finite element model predicts vertebral bone strength and fracture site. Spine 31:1789\u20131794","journal-title":"Spine"},{"key":"2705_CR10","author":"KJ Karami","year":"2014","unstructured":"Karami KJ, Buckenmeyer LE, Kiapour AM, Kelkar PS, Goel VK, Demetropoulos CK, Soo TM (2014) Biomechanical evaluation of the pedicle screw insertion depth effect on screw stability under cyclic loading and subsequent pullout. J Spinal Disord Tech. doi: 10.1097\/BSD.0000000000000178","journal-title":"J Spinal Disord Tech"},{"key":"2705_CR11","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/S0021-9290(97)00123-1","volume":"31","author":"JH Keyak","year":"1998","unstructured":"Keyak JH, Rossi SA, Jones KA, Skinner HB (1998) Prediction of femoral fracture load using automated finite element modeling. J Biomech 31:125\u2013133","journal-title":"J Biomech"},{"key":"2705_CR12","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1097\/00002517-198800140-00002","volume":"1","author":"MH Krag","year":"1989","unstructured":"Krag MH, Beynnon BD, Pope MH, DeCoster TA (1989) Depth of insertion of transpedicular vertebral screws into human vertebrae: effect upon screw-vertebra interface strength. J Spinal Disord 1:287\u2013294","journal-title":"J Spinal Disord"},{"key":"2705_CR13","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1097\/00007632-199312000-00012","volume":"18","author":"M Law","year":"1993","unstructured":"Law M, Tencer AF, Anderson PA (1993) Caudo-cephalad loading of pedicle screws: biomechanisms of loosening and methods of augmentation. Spine 18:2438\u20132443","journal-title":"Spine"},{"key":"2705_CR14","author":"GW Lee","year":"2015","unstructured":"Lee GW, Son JH, Ahn MW, Kim HJ, Yeom JS (2015) The comparison of pedicle screw and cortical screw in posterior lumbar inter-boy fusion: a prospective randomized non-inferiority trial. Spine J. doi: 10.1016\/j.spinee.2015.02.038","journal-title":"Spine J"},{"key":"2705_CR15","doi-asserted-by":"crossref","first-page":"2438","DOI":"10.1097\/01.brs.0000144355.50660.65","volume":"29","author":"B Li","year":"2004","unstructured":"Li B, Jiang B, Fu Z, Zhang D, Wang T (2004) Accurate determination of isthmus of lumbar pedicle: a morphometric study using reformatted computed tomographic imaging. Spine 29:2438\u20132444","journal-title":"Spine"},{"key":"2705_CR16","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.prosdent.2004.11.011","volume":"93","author":"A Mahmoud","year":"2005","unstructured":"Mahmoud A, Wakabayashi N, Takahashi H, Ohyama T (2005) Deflection fatigue of Ti-6Al-\u2018Nb, Co-Cr, and gold alloy cast clasps. J Prosthet Dent 93:183\u2013188","journal-title":"J Prosthet Dent"},{"key":"2705_CR17","doi-asserted-by":"crossref","first-page":"E873","DOI":"10.1097\/BRS.0000000000000983","volume":"40","author":"K Matsukawa","year":"2015","unstructured":"Matsukawa K, Taguchi E, Yato Y, Imabayashi H, Hosogane N, Asazuma T, Nemoto K (2015) Evaluation of the fixation strength of pedicle screws using cortical bone trajectory: what is the ideal trajectory for optimal fixation? Spine 40:E873\u2013E878","journal-title":"Spine"},{"key":"2705_CR18","doi-asserted-by":"crossref","first-page":"471","DOI":"10.3171\/2015.1.SPINE141103","volume":"23","author":"K Matsukawa","year":"2015","unstructured":"Matsukawa K, Yato Y, Imabayashi H, Hosogane N, Asazuma T, Nemoto K (2015) Biomechanical evaluation of fixation strength of lumbar pedicle screw using cortical bone trajectory: a finite element study. J Neurosurg Spine 23:471\u2013478","journal-title":"J Neurosurg Spine"},{"key":"2705_CR19","doi-asserted-by":"crossref","first-page":"E240","DOI":"10.1097\/BRS.0000000000000116","volume":"39","author":"K Matsukawa","year":"2014","unstructured":"Matsukawa K, Yato Y, Kato T, Imabayashi H, Asazuma T, Nemoto K (2014) In vivo analysis of insertional torque during pedicle screwing using cortical bone trajectory technique. Spine 39:E240\u2013E245","journal-title":"Spine"},{"key":"2705_CR20","doi-asserted-by":"crossref","first-page":"E248","DOI":"10.1097\/BSD.0b013e318288ac39","volume":"26","author":"K Matsukawa","year":"2013","unstructured":"Matsukawa K, Yato Y, Nemoto O, Imabayashi H, Asazuma T, Nemoto K (2013) Morphometric measurement of cortical bone trajectory for lumbar pedicle screw insertion using computed tomography. J Spinal Disord Tech 26:E248\u2013E253","journal-title":"J Spinal Disord Tech"},{"key":"2705_CR21","doi-asserted-by":"crossref","first-page":"E1291","DOI":"10.1097\/BRS.0000000000000540","volume":"39","author":"Y Matsuura","year":"2014","unstructured":"Matsuura Y, Giambini H, Ogawa Y, Fang Z, Thoreson AR, Yaszemski MJ, Lu L, An KN (2014) Specimen-specific nonlinear finite element modeling to predict vertebrae fracture loads after vertebroplasty. Spine 39:E1291\u2013E1296","journal-title":"Spine"},{"key":"2705_CR22","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1097\/00007632-199901010-00005","volume":"24","author":"TO McKinley","year":"1999","unstructured":"McKinley TO, McLain RF, Yerby SA, Sharkey NA, Sarigul-Klijn N, Smith TS (1999) Characteristics of pedicle screw loading: effect of surgical technique on intravertebral and intrapedicular bending moments. Spine 24:18\u201325","journal-title":"Spine"},{"key":"2705_CR23","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/os.12027","volume":"5","author":"RJ Mobbs","year":"2013","unstructured":"Mobbs RJ (2013) The \u201cmedio-latero-superior trajectory technique\u201d: an alternative cortical trajectory for pedicle fixation. Orthop Surg 5:56\u201359","journal-title":"Orthop Surg"},{"key":"2705_CR24","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/BRS.0b013e318279a95e","volume":"38","author":"L Perez-Orribo","year":"2013","unstructured":"Perez-Orribo L, Kalb S, Reyes PM, Chang SW, Crawford NR (2013) Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support. Spine 38:635\u2013641","journal-title":"Spine"},{"key":"2705_CR25","doi-asserted-by":"crossref","first-page":"E9","DOI":"10.3171\/2014.1.FOCUS13521","volume":"36","author":"A Rodriguez","year":"2014","unstructured":"Rodriguez A, Neal MT, Liu A, Somasundaram A, Hsu W, Branch CL Jr (2014) Novel placement of cortical bone trajectory screws in previously instrumented pedicles for adjacent-segment lumbar disease using CT image-guided navigation. Neurosurg Focus 36:E9","journal-title":"Neurosurg Focus"},{"key":"2705_CR26","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.spinee.2008.07.008","volume":"9","author":"BG Santoni","year":"2009","unstructured":"Santoni BG, Hynes RA, McGilvary KC, Rodriguez-Canessa G, Lyon AS, Henson MAW, Womack WJ, Puttlitz CM (2009) Cortical bone trajectory for lumbar pedicle screws. Spine J 9:366\u2013373","journal-title":"Spine J"},{"key":"2705_CR27","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","volume":"16","author":"S Soshi","year":"1991","unstructured":"Soshi S, Shiba R, Kondo H, Murota K (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335\u20131341","journal-title":"Spine"},{"key":"2705_CR28","doi-asserted-by":"crossref","first-page":"416","DOI":"10.3171\/2014.9.SPINE1484","volume":"22","author":"M Ueno","year":"2015","unstructured":"Ueno M, Sakai R, Tanaka K, Inoue G, Uchida K, Imura T, Saito W, Nakazawa T, Takahira N, Mabuchi K, Takaso M (2015) Should we use cortical bone screws for cortical bone trajectory? J Neurosurg Spine 22:416\u2013421","journal-title":"J Neurosurg Spine"},{"key":"2705_CR29","first-page":"S1","volume":"13","author":"SS Wu","year":"1998","unstructured":"Wu SS, Edwards WT, Yuan HA (1998) Stiffness between different directions of transpedicular screws and vertebra. Clin Biomech 13:S1\u2013S8","journal-title":"Clin Biomech"},{"key":"2705_CR30","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/00003086-198602000-00012","volume":"203","author":"MR Zindrick","year":"1986","unstructured":"Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 203:99\u2013112","journal-title":"Clin Orthop"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-016-2705-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00701-016-2705-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-016-2705-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T19:01:37Z","timestamp":1654110097000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00701-016-2705-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,15]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["2705"],"URL":"https:\/\/doi.org\/10.1007\/s00701-016-2705-8","relation":{},"ISSN":["0001-6268","0942-0940"],"issn-type":[{"value":"0001-6268","type":"print"},{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,15]]}}}