{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T10:49:01Z","timestamp":1774003741171,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,2,15]],"date-time":"2021-02-15T00:00:00Z","timestamp":1613347200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,2,15]],"date-time":"2021-02-15T00:00:00Z","timestamp":1613347200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"published-print":{"date-parts":[[2021,4]]},"DOI":"10.1007\/s00701-020-04702-1","type":"journal-article","created":{"date-parts":[[2021,2,18]],"date-time":"2021-02-18T19:55:54Z","timestamp":1613678154000},"page":"1103-1112","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Freehand stereotactic ventricular catheter insertion for ventriculoperitoneal shunts based on individualized radio-anatomical landmarks"],"prefix":"10.1007","volume":"163","author":[{"given":"Julien","family":"Spitaels","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matteo","family":"Riva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabelle","family":"Delpierre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Dewitte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3612-6647","authenticated-orcid":false,"given":"Micha\u00ebl","family":"Bruneau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,2,15]]},"reference":[{"issue":"4 suppl 2","key":"4702_CR1","first-page":"243","volume":"60","author":"SS Azeem","year":"2007","unstructured":"Azeem SS, Origitano TC (2007) Ventricular catheter placement with a frameless neuronavigational system: a 1-year experience. Neurosurgery 60(4 suppl 2):243\u2013247","journal-title":"Neurosurgery"},{"issue":"6","key":"4702_CR2","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1159\/000120484","volume":"15","author":"MS Dias","year":"1989","unstructured":"Dias MS, Albright AL (1989) Management of hydrocephalus complicating childhood posterior fossa tumors. Pediatr Neurosci 15(6):283\u2013289","journal-title":"Pediatr Neurosci"},{"issue":"1","key":"4702_CR3","doi-asserted-by":"publisher","first-page":"157","DOI":"10.3171\/jns.1998.89.1.0157","volume":"89","author":"PC Garell","year":"2009","unstructured":"Garell PC, Mirsky R, Noh MD, Loftus CM, Hitchon PW, Grady MS, Dacey RG, Howard MA (2009) Posterior ventricular catheter burr-hole localizer. J Neurosurg 89(1):157\u2013160","journal-title":"J Neurosurg"},{"issue":"6","key":"4702_CR4","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.3171\/2010.3.JNS091237","volume":"113","author":"C Hayhurst","year":"2010","unstructured":"Hayhurst C, Beems T, Jenkinson MD, Byrne P, Clark S, Kandasamy J, Goodden J, Nandoe Tewarie RDS, Mallucci CL (2010) Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study-clinical article. J Neurosurg 113(6):1273\u20131278","journal-title":"J Neurosurg"},{"issue":"6","key":"4702_CR5","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.3171\/2008.12.JNS08628","volume":"111","author":"C Hayhurst","year":"2009","unstructured":"Hayhurst C, Byrne P, Eldridge PR, Mallucci CL (2009) Application of electromagnetic technology to neuronavigation: a revolution in image-guided neurosurgery: technical note. J Neurosurg 111(6):1179\u20131184","journal-title":"J Neurosurg"},{"issue":"2","key":"4702_CR6","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3171\/jns.1995.82.2.0300","volume":"82","author":"MA Howard","year":"1995","unstructured":"Howard MA, Srinivasan J, Bevering CG, Winn HR, Grady MS (1995) A guide to placement of parietooccipital ventricular catheters. Technical note. J Neurosurg 82(2):300\u2013304","journal-title":"J Neurosurg"},{"issue":"3\u20134","key":"4702_CR7","first-page":"5","volume":"82","author":"AS Jakola","year":"2014","unstructured":"Jakola AS, Reinertsen I, Selbekk T, Solheim O, Lindseth F, Gulati S, Unsg\u00e5rd G (2014) Three-dimensional ultrasound-guided placement of ventricular catheters. World Neurosurg 82(3\u20134):5\u20139","journal-title":"World Neurosurg"},{"issue":"3","key":"4702_CR8","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1093\/neuros\/nyy074","volume":"84","author":"NR Khan","year":"2019","unstructured":"Khan NR, DeCuypere M, Vaughn BN, Klimo P (2019) Image guidance for ventricular shunt surgery: an analysis of ventricular size and proximal revision rates. Clin Neurosurg 84(3):624\u2013635","journal-title":"Clin Neurosurg"},{"issue":"1","key":"4702_CR9","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.jocn.2004.12.010","volume":"13","author":"YB Kim","year":"2006","unstructured":"Kim YB, Lee JW, Lee KS, Lee KC (2006) Image-guided placement of ventricular shunt catheter. J Clin Neurosci 13(1):50\u201354","journal-title":"J Clin Neurosci"},{"issue":"2","key":"4702_CR10","doi-asserted-by":"publisher","first-page":"112","DOI":"10.3171\/2012.3.PEDS122","volume":"10","author":"MR Levitt","year":"2012","unstructured":"Levitt MR, O\u2019Neill BR, Ishak GE, Khanna PC, Temkin NR, Ellenbogen RG, Ojemann JG, Browd SR (2012) Image-guided cerebrospinal fluid shunting in children: catheter accuracy and shunt survival: clinical article. J Neurosurg Pediatr 10(2):112\u2013117","journal-title":"J Neurosurg Pediatr"},{"issue":"7","key":"4702_CR11","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1016\/j.jocn.2008.09.015","volume":"16","author":"CRP Lind","year":"2009","unstructured":"Lind CRP, Tsai AMC, Lind CJ, Law AJJ (2009) Ventricular catheter placement accuracy in non-stereotactic shunt surgery for hydrocephalus. J Clin Neurosci 16(7):918\u2013920","journal-title":"J Clin Neurosci"},{"issue":"2","key":"4702_CR12","doi-asserted-by":"publisher","first-page":"269","DOI":"10.3171\/JNS\/2008\/108\/2\/0269","volume":"108","author":"SS Lollis","year":"2008","unstructured":"Lollis SS, Roberts DW (2008) Robotic catheter ventriculostomy: feasibility, efficacy, and implications. J Neurosurg 108(2):269\u2013274","journal-title":"J Neurosurg"},{"key":"4702_CR13","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1016\/j.wneu.2016.10.136","volume":"98","author":"AE Merkler","year":"2017","unstructured":"Merkler AE, Ch\u2019ang J, Parker WE, Murthy SB, Kamel H (2017) The rate of complications after ventriculoperitoneal shunt surgery. World Neurosurg 98:654\u2013658","journal-title":"World Neurosurg"},{"issue":"4","key":"4702_CR14","doi-asserted-by":"publisher","first-page":"750","DOI":"10.3171\/jns.1994.80.4.0750","volume":"80","author":"D Pang","year":"1994","unstructured":"Pang D, Grabb PA (1994) Accurate placement of coronal ventricular catheter using stereotactic coordinate-guided free-hand passage. Technical note. J Neurosurg 80(4):750\u2013755","journal-title":"J Neurosurg"},{"issue":"8","key":"4702_CR15","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1007\/s00381-012-1838-1","volume":"28","author":"J Roth","year":"2012","unstructured":"Roth J, Constantini S (2012) Selective use of intra-catheter endoscopic-assisted ventricular catheter placement: indications and outcome. Childs Nerv Syst 28(8):1163\u20131169","journal-title":"Childs Nerv Syst"},{"issue":"3 Suppl Operati","key":"4702_CR16","first-page":"131","volume":"67","author":"LH Stieglitz","year":"2010","unstructured":"Stieglitz LH, Giordano M, Samii M, Luedemann WO (2010) A new tool for frameless stereotactic placement of ventricular catheters. Neurosurgery 67(3 Suppl Operative):131\u2013135","journal-title":"Neurosurgery"},{"issue":"1","key":"4702_CR17","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1017\/S0317167100052562","volume":"28","author":"PV Theodosopoulos","year":"2001","unstructured":"Theodosopoulos PV, Abosch A, McDermott MW (2001) Intraoperative fiber-optic endoscopy for ventricular catheter insertion. Can J Neurol Sci 28(1):56\u201360","journal-title":"Can J Neurol Sci"},{"issue":"1","key":"4702_CR18","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s00381-012-1943-1","volume":"29","author":"UW Thomale","year":"2013","unstructured":"Thomale UW, Knitter T, Schaumann A, Ahmadi SA, Ziegler P, Schulz M, Miethke C (2013) Smartphone-assisted guide for the placement of ventricular catheters. Childs Nerv Syst 29(1):131\u2013139","journal-title":"Childs Nerv Syst"},{"issue":"2","key":"4702_CR19","first-page":"252","volume":"83","author":"U-W Thomale","year":"2016","unstructured":"Thomale U-W, Schaumann A, Stockhammer F, Giese H, Schuster D, K\u00e4stner S, Ahmadi A-S, Polemikos M, Bock H-C, G\u00f6lz L, Lemcke J, Hermann H, Schuhmann M-U, Beez T, Fritsch M, Orakcioglu B, Vajkoczy P, Rohde V, Bohner G (2016) The GAVCA study-effect of a mobile health application to assist ventricular catheter guidance in a randomized, prospective multicenter trial. Childs Nerv Syst 83(2):252\u2013262","journal-title":"Childs Nerv Syst"},{"issue":"4","key":"4702_CR20","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.jocn.2010.06.018","volume":"18","author":"KR Wan","year":"2011","unstructured":"Wan KR, Toy JA, Wolfe R, Danks A (2011) Factors affecting the accuracy of ventricular catheter placement. J Clin Neurosci 18(4):485\u2013488","journal-title":"J Clin Neurosci"},{"key":"4702_CR21","unstructured":"Wang C, Du H-g, Yin L-c, He M, Zhang G-j, Tian Y, Hao B-l (2013) Analysis of related factors affecting prognosis of shunt surgery in patients with secondary normal pressure hydrocephalus. Chin J Traumatol 16(4):221\u2013224"},{"issue":"5 Suppl","key":"4702_CR22","first-page":"406","volume":"107","author":"WE Whitehead","year":"2007","unstructured":"Whitehead WE, Jea A, Vachhrajani S, Kulkarni AV, Drake JM (2007) Accurate placement of cerebrospinal fluid shunt ventricular catheters with real-time ultrasound guidance in older children without patent fontanelles: technical note. J Neurosurg 107(5 Suppl):406\u2013410","journal-title":"J Neurosurg"},{"issue":"1","key":"4702_CR23","doi-asserted-by":"publisher","first-page":"66","DOI":"10.3171\/2012.11.JNS111384","volume":"119","author":"TJ Wilson","year":"2013","unstructured":"Wilson TJ, Stetler WR, Al-Holou WN, Sullivan SE (2013) Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation: clinical article. J Neurosurg 119(1):66\u201370","journal-title":"J Neurosurg"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-020-04702-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00701-020-04702-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-020-04702-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,17]],"date-time":"2021-03-17T05:25:41Z","timestamp":1615958741000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00701-020-04702-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,15]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,4]]}},"alternative-id":["4702"],"URL":"https:\/\/doi.org\/10.1007\/s00701-020-04702-1","relation":{},"ISSN":["0001-6268","0942-0940"],"issn-type":[{"value":"0001-6268","type":"print"},{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,15]]},"assertion":[{"value":"28 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The authors confirm that the study was approved by the institutional ethics committee of Erasme Hospital and certify that the study was performed in accordance with the ethical standards as laid down in the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"According to ethic committee agreement, patient\u2019s informed consent was deemed not necessary given the retrospective nature of the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}