{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T23:52:53Z","timestamp":1776901973842,"version":"3.51.2"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2022,4,26]],"date-time":"2022-04-26T00:00:00Z","timestamp":1650931200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,4,26]],"date-time":"2022-04-26T00:00:00Z","timestamp":1650931200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"published-print":{"date-parts":[[2022,6]]},"DOI":"10.1007\/s00701-022-05217-7","type":"journal-article","created":{"date-parts":[[2022,4,26]],"date-time":"2022-04-26T12:02:56Z","timestamp":1650974576000},"page":"1501-1507","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["PEEK versus titanium-coated PEEK cervical cages: fusion rate"],"prefix":"10.1007","volume":"164","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0673-1480","authenticated-orcid":false,"given":"Bartosz","family":"Godlewski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6687-1517","authenticated-orcid":false,"given":"Adam","family":"Bebenek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maciej","family":"Dominiak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Grzegorz","family":"Karpinski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piotr","family":"Cieslik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1421-2050","authenticated-orcid":false,"given":"Tomasz","family":"Pawelczyk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,4,26]]},"reference":[{"key":"5217_CR1","doi-asserted-by":"publisher","first-page":"S149","DOI":"10.1097\/BRS.0b013e3182a7f449","volume":"38","author":"CP Ames","year":"2013","unstructured":"Ames CP, Blondel B, Scheer JK, Schwabb FJ, Le Huec JC, Massicotte EM, Patel AA, Traynelis VC, Kim HJ, Shaffrey CI, Smith JS, Lafage V (2013) Cervical radiographical alignment: comprehensive assessment techniques and potential importance in cervical myelopathy. Spine 38:S149\u2013S160. https:\/\/doi.org\/10.1097\/BRS.0b013e3182a7f449","journal-title":"Spine"},{"key":"5217_CR2","doi-asserted-by":"publisher","first-page":"2372","DOI":"10.1007\/s00586-017-5079-6","volume":"26","author":"MP Arts","year":"2017","unstructured":"Arts MP, Wolfs JF, Corbin TP (2017) Porous silicon nitride spacers versus PEEK cages for anterior cervical discectomy and fusion: clinical and radiological results of a single-blinded randomized controlled trial. Eur Spine J 26:2372\u20132379. https:\/\/doi.org\/10.1007\/s00586-017-5079-6","journal-title":"Eur Spine J"},{"key":"5217_CR3","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1080\/02688699844411","volume":"12","author":"MJ Arunkumar","year":"1998","unstructured":"Arunkumar MJ, Rajshekhar V (1998) Artificats in magnetic resonance images following anterior cervical discectomy and fusion: report of two cases. Br J Neurosurg 12:553\u2013555. https:\/\/doi.org\/10.1080\/02688699844411","journal-title":"Br J Neurosurg"},{"key":"5217_CR4","doi-asserted-by":"publisher","first-page":"1185","DOI":"10.1097\/BRS.0b013e318171927c","volume":"33","author":"JM Buchowski","year":"2008","unstructured":"Buchowski JM, Liu G, Bunmapresert T, Rose PS, Riew KD (2008) Anterior cervical fusion assessment: surgical exploration versus radiographic evaluation. Spine 33:1185\u20131191. https:\/\/doi.org\/10.1097\/BRS.0b013e318171927c","journal-title":"Spine"},{"key":"5217_CR5","doi-asserted-by":"publisher","first-page":"2832","DOI":"10.1007\/s00586-014-3725-9","volume":"24","author":"C Brenke","year":"2015","unstructured":"Brenke C, Dostal M, Scharf J, Wei\u00df C, Schmieder K, Barth M (2015) Influence of cervical bone mineral density on cage subsidence in patients following stand-alone anterior cervical discectomy and fusion. Eur Spine J 24:2832\u20132840. https:\/\/doi.org\/10.1007\/s00586-014-3725-9","journal-title":"Eur Spine J"},{"key":"5217_CR6","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/s1529-9430(01)00154-1","volume":"2","author":"NE Epstein","year":"2018","unstructured":"Epstein NE, Silvergleide RS, Black K (2018) Computed tomography validating bony ingrowth into fibula strut allograft: a criterion for fusion. Spine J 2:129\u2013133. https:\/\/doi.org\/10.1016\/s1529-9430(01)00154-1","journal-title":"Spine J"},{"key":"5217_CR7","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1007\/s00586-017-5450-7","volume":"27","author":"SW Feng","year":"2018","unstructured":"Feng SW, Chang MC, Chou PH, Lin HH, Wang ST, Liu CL (2018) Implantation of an empty polyetheretherketone cage in anterior cervical discectomy and fusion: a prospective randomized controlled study with 2 years follow-up. Eur Spine J 27:1358\u20131364. https:\/\/doi.org\/10.1007\/s00586-017-5450-7","journal-title":"Eur Spine J"},{"key":"5217_CR8","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1007\/s00586-003-0539-6","volume":"12","author":"E Gercek","year":"2003","unstructured":"Gercek E, Arlet V, Delisle J, Marchesi D (2003) Subsidence of stand-alone cervical cages in anterior interbody fusion: warning. Eur Spine J 12:513\u2013516. https:\/\/doi.org\/10.1007\/s00586-003-0539-6","journal-title":"Eur Spine J"},{"key":"5217_CR9","doi-asserted-by":"publisher","first-page":"213","DOI":"10.5604\/01.3001.0014.3457","volume":"22","author":"B Godlewski","year":"2020","unstructured":"Godlewski B, Dominiak M (2020) Advantages and disadvantages of the use of various types of interbody implants in cervical spine surgery. Critical review of the literature. Ortop Traumatol Rehabil 22:213\u2013220. https:\/\/doi.org\/10.5604\/01.3001.0014.3457","journal-title":"Ortop Traumatol Rehabil"},{"key":"5217_CR10","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.colsurfb.2018.12.037","volume":"175","author":"DJ Hickey","year":"2019","unstructured":"Hickey DJ, Lorman B, Fedder IL (2019) Improved response of osteoprogenitor cells to titanium plasma-sprayed PEEK surfaces. Colloids Surf B Biointerfaces 175:509\u2013516. https:\/\/doi.org\/10.1016\/j.colsurfb.2018.12.037","journal-title":"Colloids Surf B Biointerfaces"},{"key":"5217_CR11","doi-asserted-by":"publisher","DOI":"10.1177\/2192568220963061","author":"HJ Jang","year":"2020","unstructured":"Jang HJ, Chin DK, Kim KH, Park JY (2020) Does graft position affect subsidence after anterior cervical discectomy and fusion? Global Spine Journal. https:\/\/doi.org\/10.1177\/2192568220963061","journal-title":"Global Spine Journal"},{"key":"5217_CR12","doi-asserted-by":"publisher","first-page":"221","DOI":"10.3171\/2009.3.SPINE08719","volume":"11","author":"MG Kaiser","year":"2009","unstructured":"Kaiser MG, Mummaneni PV, Matz PG, Anderson PA, Groff MW, Heary RF, Holly LT, Ryken TC, Choudhri TF, Vresilovic EJ, Resnick DK (2009) Radiographic assessment of cervical subaxial fusion. J Neurosurg Spine 11:221\u2013227. https:\/\/doi.org\/10.3171\/2009.3.SPINE08719","journal-title":"J Neurosurg Spine"},{"key":"5217_CR13","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1016\/j.spinee.2013.08.030","volume":"15","author":"RF Kersten","year":"2015","unstructured":"Kersten RF, van Gaalen SM, de Gast A, Oner FC (2015) Polyetheretherketone (PEEK) cages in cervical applications: a systematic review. Spine J 15:1446\u20131460. https:\/\/doi.org\/10.1016\/j.spinee.2013.08.030","journal-title":"Spine J"},{"key":"5217_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/BSD.0b013e31825bd26d","volume":"27","author":"IO Karikari","year":"2014","unstructured":"Karikari IO, Jain D, Owens TR, Gottfried O, Hodges TR, Nimjee SM, Bagley CA (2014) Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion: a systematic review. J Spinal Disord Tech 27:1\u201310. https:\/\/doi.org\/10.1097\/BSD.0b013e31825bd26d","journal-title":"J Spinal Disord Tech"},{"issue":"11","key":"5217_CR15","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/s13037-017-0127-z","volume":"28","author":"A Kotsias","year":"2017","unstructured":"Kotsias A, Mularski S, Kuhn B, Hanna M, Suess O (2017) Does partial coating with titanium improve the radiographic fusion rate of empty PEEK cages in cervical spine surgery? A comparative analysis of clinical data. Patient Saf Surg 28(11):13. https:\/\/doi.org\/10.1186\/s13037-017-0127-z","journal-title":"Patient Saf Surg"},{"key":"5217_CR16","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28:4845\u20134869. https:\/\/doi.org\/10.1016\/j.biomaterials.2007.07.013","journal-title":"Biomaterials"},{"key":"5217_CR17","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s00701-019-04139-1","volume":"162","author":"T Obermueller","year":"2020","unstructured":"Obermueller T, Wagner A, Kogler L, Joerger AK, Lange N, Lehmberg J, Meyer B, Shiban E (2020) Radiographic measurements of cervical alignment, fusion and subsidence after ACDF surgery and their impact on clinical outcome. Acta Neurochir 162:89\u201399. https:\/\/doi.org\/10.1007\/s00701-019-04139-1","journal-title":"Acta Neurochir"},{"key":"5217_CR18","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/s00586-019-06281-x","volume":"29","author":"L Papavero","year":"2020","unstructured":"Papavero L, Lepori P, Schmeiser G (2020) Revision surgery in cervical spine. Eur Spine J 29:47\u201356. https:\/\/doi.org\/10.1007\/s00586-019-06281-x","journal-title":"Eur Spine J"},{"key":"5217_CR19","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.jocn.2016.01.042","volume":"33","author":"JY Park","year":"2016","unstructured":"Park JY, Choi KY, Moon BJ, Hur H, Jang JW, Lee JK (2016) Subsidence after single-level anterior cervical fusion with a stand-alone cage. J Clin Neurosci 33:83\u201388. https:\/\/doi.org\/10.1016\/j.jocn.2016.01.042","journal-title":"J Clin Neurosci"},{"key":"5217_CR20","doi-asserted-by":"publisher","first-page":"E208","DOI":"10.1097\/BSD.0b013e31826851a4","volume":"29","author":"MH Pelletier","year":"2016","unstructured":"Pelletier MH, Cordaro N, Punjabi VM, Lau WM, A, Walsh WR, (2016) PEEK versus Ti interbody fusion devices: resultant fusion, bone appostion, initial and 26 biomechanics. Clin Spine Surg 29:E208\u2013E214. https:\/\/doi.org\/10.1097\/BSD.0b013e31826851a4","journal-title":"Clin Spine Surg"},{"key":"5217_CR21","first-page":"342","volume":"72","author":"A Ploumis","year":"2006","unstructured":"Ploumis A, Mehbod A, Garvey T, Gilbert T, Transfeldt E, Wood K (2006) Prospective assessment of cervical fusion status: plain radiographs versus CT-scan. Acta Orthop Belg 72:342\u2013346","journal-title":"Acta Orthop Belg"},{"key":"5217_CR22","doi-asserted-by":"publisher","first-page":"447","DOI":"10.3171\/spi.2006.4.6.447","volume":"4","author":"K Schmieder","year":"2006","unstructured":"Schmieder K, Wolzik-Grossmann M, Pechlivanis I, Engelhardt M, Scholz M, Harders A (2006) Subsidence of the wing titanium cage after anterior cervical interbody fusion: 2-year follow-up study. J Neurosurg Spine 4:447\u2013453. https:\/\/doi.org\/10.3171\/spi.2006.4.6.447","journal-title":"J Neurosurg Spine"},{"key":"5217_CR23","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1007\/BF02187193","volume":"137","author":"B Sutter","year":"1995","unstructured":"Sutter B, Friehs G, Pendl G, T\u00f6lly E (1995) Bovine dowels for anterior cervical fusion: experience in 66 patients with a note on postoperative CT and MRI appearance. Acta Neurochir 137:192\u2013198. https:\/\/doi.org\/10.1007\/BF02187193","journal-title":"Acta Neurochir"},{"key":"5217_CR24","doi-asserted-by":"publisher","first-page":"856","DOI":"10.1097\/00007632-200404150-00007","volume":"29","author":"SK Tuli","year":"2004","unstructured":"Tuli SK, Chen P, Eichler ME, Woodard EJ (2004) Reliability of radiologic assessment of fusion: cervical fibular allograft model. Spine 29:856\u2013860. https:\/\/doi.org\/10.1097\/00007632-200404150-00007","journal-title":"Spine"},{"key":"5217_CR25","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1016\/j.spinee.2014.12.018","volume":"15","author":"WR Walsh","year":"2015","unstructured":"Walsh WR, Bertollo N, Christou C, Schaffner D, Mobbs RJ (2015) Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. Spine J 15:1041\u20131049. https:\/\/doi.org\/10.1016\/j.spinee.2014.12.018","journal-title":"Spine J"},{"key":"5217_CR26","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1097\/00007632-199905010-00011","volume":"24","author":"JC Wang","year":"1999","unstructured":"Wang JC, Yu WD, Sandhu HS, Betts F, Bhuta S, Delamarter RB (1999) Metal debris from Titanium Spinal Implants. Spine 24:899\u2013903. https:\/\/doi.org\/10.1097\/00007632-199905010-00011","journal-title":"Spine"},{"key":"5217_CR27","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1016\/j.jocn.2011.11.043","volume":"19","author":"T Yamagata","year":"2012","unstructured":"Yamagata T, Takami T, Uda T, Ikeda H, Nagata T, Sakamoto S, Tsuyuguchi N, Ohata K (2012) Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment. J Clin Neurosci 19:1673\u20131678. https:\/\/doi.org\/10.1016\/j.jocn.2011.11.043","journal-title":"J Clin Neurosci"},{"key":"5217_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13037-014-0043-4","volume":"8","author":"D Zajonz","year":"2014","unstructured":"Zajonz D, Franke AC, der H\u00f6h N, Von VA, Moche M, Gulow J, Heyde CE (2014) Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring. Patient Saf Surg 8:1\u20139. https:\/\/doi.org\/10.1186\/s13037-014-0043-4","journal-title":"Patient Saf Surg"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-022-05217-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00701-022-05217-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-022-05217-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T09:06:33Z","timestamp":1654074393000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00701-022-05217-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,26]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["5217"],"URL":"https:\/\/doi.org\/10.1007\/s00701-022-05217-7","relation":{},"ISSN":["0942-0940"],"issn-type":[{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,26]]},"assertion":[{"value":"3 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the relevant institutional and national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}