{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T19:24:19Z","timestamp":1767900259401,"version":"3.49.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T00:00:00Z","timestamp":1736380800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T00:00:00Z","timestamp":1736380800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/100013490","name":"Brain Aneurysm Foundation","doi-asserted-by":"publisher","award":["2022 and 2023 award"],"award-info":[{"award-number":["2022 and 2023 award"]}],"id":[{"id":"10.13039\/100013490","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"DOI":"10.1007\/s00701-024-06392-5","type":"journal-article","created":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T21:57:40Z","timestamp":1736459860000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Aneurysm dome and vessel pressure measurements with coiling, stent assisted coiling and flow diversion"],"prefix":"10.1007","volume":"167","author":[{"given":"Timothy A.","family":"Becker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kailey L.","family":"Lewis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Holly F.","family":"Berns","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sophia E.","family":"Robertson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wyatt E.","family":"Clark","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jesse C.","family":"Wells","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed K.","family":"Alnajrani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Rapoport","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Barhouse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Felipe","family":"Ramirez-Velandia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean","family":"Filo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Young","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandeep","family":"Muram","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justin H.","family":"Granstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher S.","family":"Ogilvy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,1,9]]},"reference":[{"issue":"8","key":"6392_CR1","first-page":"1532","volume":"21","author":"HG Boecher-Schwarz","year":"2000","unstructured":"Boecher-Schwarz HG, Ringel K, Kopacz L, Heimann A, Kempski O (2000) Ex vivo study of the physical effect of coils on pressure and flow dynamics in experimental aneurysms. AJNR Am J Neuroradiol 21(8):1532\u20131536","journal-title":"AJNR Am J Neuroradiol"},{"key":"6392_CR2","doi-asserted-by":"publisher","unstructured":"Brake A, Fry L, Heskett C, De Stefano FA, Lei C, Ebersole K (2023) Flow diversion jet: a dangerous mechanism in the flow diversion treatment of giant intracranial aneurysms. Interv Neuroradiol. Published Online May 11. https:\/\/doi.org\/10.1177\/15910199231175622","DOI":"10.1177\/15910199231175622"},{"issue":"3","key":"6392_CR3","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1177\/1591019918756583","volume":"24","author":"D Brunozzi","year":"2018","unstructured":"Brunozzi D, Shakur SF, Charbel FT, Alaraj A (2018) Middle cerebral artery pressure changes following Pipeline flow diversion. Interv Neuroradiol 24(3):297\u2013302. https:\/\/doi.org\/10.1177\/1591019918756583","journal-title":"Interv Neuroradiol"},{"issue":"3","key":"6392_CR4","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1177\/15910199211032467","volume":"28","author":"D Brunozzi","year":"2022","unstructured":"Brunozzi D, See A, Rizko M, Choi J, Atwal G, Alaraj A (2022) Impact of cerebral aneurysm size on distal intracranial hemodynamics and changes following flow diversion. Interv Neuroradiol 28(3):291\u2013295. https:\/\/doi.org\/10.1177\/15910199211032467","journal-title":"Interv Neuroradiol"},{"issue":"4","key":"6392_CR5","first-page":"904","volume":"26","author":"G Cant\u00f3n","year":"2005","unstructured":"Cant\u00f3n G, Levy DI, Lasheras JC (2005) Changes in the intraaneurysmal pressure due to HydroCoil embolization. AJNR Am J Neuroradiol 26(4):904\u2013907","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1","key":"6392_CR6","doi-asserted-by":"publisher","first-page":"27","DOI":"10.3174\/ajnr.A2398","volume":"32","author":"JR Cebral","year":"2011","unstructured":"Cebral JR, Mut F, Raschi M et al (2011) Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment. AJNR Am J Neuroradiol 32(1):27\u201333. https:\/\/doi.org\/10.3174\/ajnr.A2398","journal-title":"AJNR Am J Neuroradiol"},{"issue":"9","key":"6392_CR7","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1136\/neurintsurg-2014-011289","volume":"7","author":"JY Chueh","year":"2015","unstructured":"Chueh JY, Vedantham S, Wakhloo AK et al (2015) Aneurysm permeability following coil embolization: packing density and coil distribution. J NeuroInterventional Surg 7(9):676\u2013681. https:\/\/doi.org\/10.1136\/neurintsurg-2014-011289","journal-title":"J NeuroInterventional Surg"},{"key":"6392_CR8","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.jocn.2018.10.093","volume":"59","author":"M Corriveau","year":"2019","unstructured":"Corriveau M, Ahmed A, Dawkins D, Kienitz BA, Niemann D, Li Y (2019) The effect of flow diverting stents on in vivo intrasaccular aneurysm pressure. J Clin Neurosci 59:339\u2013341. https:\/\/doi.org\/10.1016\/j.jocn.2018.10.093","journal-title":"J Clin Neurosci"},{"key":"6392_CR9","doi-asserted-by":"publisher","unstructured":"Griffin M, Premakumar Y, Seifalian A, Butler PE, Szarko M (2016) Biomechanical characterization of human soft tissues using indentation and Tensile Testing. J Vis Exp 11854872. https:\/\/doi.org\/10.3791\/54872","DOI":"10.3791\/54872"},{"issue":"12","key":"6392_CR10","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1097\/00004647-200112000-00011","volume":"21","author":"C Groden","year":"2001","unstructured":"Groden C, Laudan J, Gatchell S, Zeumer H (2001) Three-dimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm. J Cereb Blood Flow Metab 21(12):1464\u20131471. https:\/\/doi.org\/10.1097\/00004647-200112000-00011","journal-title":"J Cereb Blood Flow Metab"},{"issue":"2","key":"6392_CR11","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1136\/jnis.2010.002873","volume":"3","author":"T Hampton","year":"2011","unstructured":"Hampton T, Walsh D, Tolias C, Fiorella D (2011) Mural destabilization after aneurysm treatment with a flow-diverting device: a report of two cases. J Neurointerv Surg 3(2):167\u2013171. https:\/\/doi.org\/10.1136\/jnis.2010.002873","journal-title":"J Neurointerv Surg"},{"issue":"4","key":"6392_CR12","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1093\/neuros\/nyx441","volume":"83","author":"AE Hussein","year":"2018","unstructured":"Hussein AE, Brunozzi D, Shakur SF, Ismail R, Charbel FT, Alaraj A (2018) Cerebral aneurysm size and distal intracranial hemodynamics: an Assessment of flow and pulsatility index using quantitative magnetic resonance angiography. Neurosurgery 83(4):660\u2013665. https:\/\/doi.org\/10.1093\/neuros\/nyx441","journal-title":"Neurosurgery"},{"issue":"6","key":"6392_CR13","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1177\/1591019915609121","volume":"21","author":"H Ikeda","year":"2015","unstructured":"Ikeda H, Ishii A, Kikuchi T et al (2015) Delayed aneurysm rupture due to residual blood flow at the inflow zone of the intracranial paraclinoid internal carotid aneurysm treated with the Pipeline embolization device: histopathological investigation. Interv Neuroradiol 21(6):674\u2013683. https:\/\/doi.org\/10.1177\/1591019915609121","journal-title":"Interv Neuroradiol"},{"issue":"5","key":"6392_CR14","doi-asserted-by":"publisher","first-page":"347","DOI":"10.2176\/nmc.53.347","volume":"53","author":"K Kono","year":"2013","unstructured":"Kono K, Shintani A, Okada H, Terada T (2013) Preoperative simulations of endovascular treatment for a cerebral aneurysm using a patient-specific vascular silicone model: \u2014Technical Note\u2014. Neurol Med Chir (Tokyo) 53(5):347\u2013351. https:\/\/doi.org\/10.2176\/nmc.53.347","journal-title":"Neurol Med Chir (Tokyo)"},{"issue":"1","key":"6392_CR15","doi-asserted-by":"publisher","first-page":"20","DOI":"10.3174\/ajnr.A2370","volume":"32","author":"Z Kulcs\u00e1r","year":"2011","unstructured":"Kulcs\u00e1r Z, Houdart E, Bonaf\u00e9 A et al (2011) Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment. AJNR Am J Neuroradiol 32(1):20\u201325. https:\/\/doi.org\/10.3174\/ajnr.A2370","journal-title":"AJNR Am J Neuroradiol"},{"issue":"4","key":"6392_CR16","doi-asserted-by":"publisher","first-page":"816","DOI":"10.3174\/ajnr.A3288","volume":"34","author":"I Larrabide","year":"2013","unstructured":"Larrabide I, Aguilar ML, Morales HG et al (2013) Intra-aneurysmal pressure and flow changes induced by flow diverters: relation to aneurysm size and shape. AJNR Am J Neuroradiol 34(4):816\u2013822. https:\/\/doi.org\/10.3174\/ajnr.A3288","journal-title":"AJNR Am J Neuroradiol"},{"key":"6392_CR17","doi-asserted-by":"publisher","first-page":"e48","DOI":"10.1016\/j.wneu.2023.06.093","volume":"178","author":"P Mirpuri","year":"2023","unstructured":"Mirpuri P, Khalid SI, McGuire LS, Alaraj A (2023) Trends in ruptured and unruptured aneurysmal treatment from 2010 to 2020: a focus on flow diversion. World Neurosurg 178:e48\u201356. https:\/\/doi.org\/10.1016\/j.wneu.2023.06.093","journal-title":"World Neurosurg"},{"issue":"3","key":"6392_CR18","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1002\/jbm.a.37314","volume":"110","author":"NG Norris","year":"2022","unstructured":"Norris NG, Merritt WC, Becker TA (2022) Application of nondestructive mechanical characterization testing for creating in vitro vessel models with material properties similar to human neurovasculature. J Biomed Mater Res A 110(3):612\u2013622. https:\/\/doi.org\/10.1002\/jbm.a.37314","journal-title":"J Biomed Mater Res A"},{"issue":"2","key":"6392_CR19","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1227\/NEU.0000000000000744","volume":"77","author":"CS Ogilvy","year":"2015","unstructured":"Ogilvy CS, Chua MH, Fusco MR et al (2015) Validation of a system to predict recanalization after endovascular treatment of intracranial aneurysms. Neurosurgery 77(2):168\u2013174. https:\/\/doi.org\/10.1227\/NEU.0000000000000744","journal-title":"Neurosurgery"},{"issue":"6","key":"6392_CR20","doi-asserted-by":"publisher","first-page":"e0233981","DOI":"10.1371\/journal.pone.0233981","volume":"15","author":"P Piasecki","year":"2020","unstructured":"Piasecki P, Ziecina P, Brzozowski K, Wierzbicki M, Narloch J (2020) Intra-aneurysmal pressure changes during stent-assisted coiling. PLoS ONE 15(6):e0233981. https:\/\/doi.org\/10.1371\/journal.pone.0233981","journal-title":"PLoS ONE"},{"issue":"1","key":"6392_CR21","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s12017-024-08791-4","volume":"26","author":"F Ramirez-Velandia","year":"2024","unstructured":"Ramirez-Velandia F, Mensah E, Salih M et al (2024) Endothelial progenitor cells: a review of molecular mechanisms in the Pathogenesis and endovascular treatment of intracranial aneurysms. Neuromolecular Med 26(1):25. https:\/\/doi.org\/10.1007\/s12017-024-08791-4","journal-title":"Neuromolecular Med"},{"issue":"Suppl 1","key":"6392_CR22","doi-asserted-by":"publisher","first-page":"S13","DOI":"10.1093\/neuros\/nyz324","volume":"86","author":"K Ravindran","year":"2020","unstructured":"Ravindran K, Casabella AM, Cebral J, Brinjikji W, Kallmes DF, Kadirvel R (2020) Mechanism of action and biology of flow diverters in the treatment of intracranial aneurysms. Neurosurgery 86(Suppl 1):S13\u2013S19. https:\/\/doi.org\/10.1093\/neuros\/nyz324","journal-title":"Neurosurgery"},{"issue":"6","key":"6392_CR23","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1161\/01.STR.0000073841.88563.E9","volume":"34","author":"J Raymond","year":"2003","unstructured":"Raymond J, Guilbert F, Weill A et al (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34(6):1398\u20131403. https:\/\/doi.org\/10.1161\/01.STR.0000073841.88563.E9","journal-title":"Stroke"},{"key":"6392_CR24","doi-asserted-by":"publisher","first-page":"7216","DOI":"10.1038\/s41598-023-34228-2","volume":"13","author":"A Rostamian","year":"2023","unstructured":"Rostamian A, Fallah K, Rostamiyan Y (2023) Reduction of rupture risk in ICA aneurysms by endovascular techniques of coiling and stent: Numerical study. Sci Rep 13:7216. https:\/\/doi.org\/10.1038\/s41598-023-34228-2","journal-title":"Sci Rep"},{"issue":"6","key":"6392_CR25","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.1227\/NEU.0b013e3181f9a93b","volume":"67","author":"CM Schirmer","year":"2010","unstructured":"Schirmer CM, Malek AM (2010) Critical influence of framing coil orientation on intra-aneurysmal and neck region hemodynamics in a sidewall aneurysm model. Neurosurgery 67(6):1692\u20131702 discussion 1702. https:\/\/doi.org\/10.1227\/NEU.0b013e3181f9a93b","journal-title":"Neurosurgery"},{"issue":"1","key":"6392_CR26","doi-asserted-by":"publisher","first-page":"E1","DOI":"10.3174\/ajnr.A2613","volume":"34","author":"JJ Schneiders","year":"2013","unstructured":"Schneiders JJ, VanBavel E, Majoie CB, Ferns SP, van den Berg R (2013) A flow-diverting stent is not a pressure-diverting stent. Am J Neuroradiol 34(1):E1\u20134. https:\/\/doi.org\/10.3174\/ajnr.A2613","journal-title":"Am J Neuroradiol"},{"issue":"4","key":"6392_CR27","doi-asserted-by":"publisher","first-page":"727","DOI":"10.3174\/ajnr.A3742","volume":"35","author":"M Shapiro","year":"2014","unstructured":"Shapiro M, Raz E, Becske T, Nelson PK (2014) Variable porosity of the Pipeline Embolization device in straight and Curved vessels: a guide for optimal deployment strategy. AJNR Am J Neuroradiol 35(4):727\u2013733. https:\/\/doi.org\/10.3174\/ajnr.A3742","journal-title":"AJNR Am J Neuroradiol"},{"issue":"12","key":"6392_CR28","doi-asserted-by":"publisher","first-page":"2278","DOI":"10.3174\/ajnr.A5874","volume":"39","author":"M Shapiro","year":"2018","unstructured":"Shapiro M, Shapiro A, Raz E, Becske T, Riina H, Nelson PK (2018) Toward better understanding of flow diversion in bifurcation aneurysms. Am J Neuroradiol 39(12):2278\u20132283. https:\/\/doi.org\/10.3174\/ajnr.A5874","journal-title":"Am J Neuroradiol"},{"issue":"2","key":"6392_CR29","doi-asserted-by":"publisher","first-page":"E509","DOI":"10.1227\/NEU.0b013e318258e1f8","volume":"71","author":"AH Siddiqui","year":"2012","unstructured":"Siddiqui AH, Kan P, Abla AA, Hopkins LN, Levy EI (2012) Complications after treatment with pipeline embolization for giant distal intracranial aneurysms with or without coil embolization. Neurosurgery 71(2):E509\u2013513 discussion E513. https:\/\/doi.org\/10.1227\/NEU.0b013e318258e1f8","journal-title":"Neurosurgery"},{"issue":"6","key":"6392_CR30","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1136\/neurintsurg-2014-011214","volume":"8","author":"S Tateshima","year":"2016","unstructured":"Tateshima S, Jones JG, Mayor Basto F, Vinuela F, Duckwiler GR (2016) Aneurysm pressure measurement before and after placement of a pipeline stent: feasibility study using a 0.014\u2005inch pressure wire for coronary intervention. J Neurointerv Surg 8(6):603\u2013607. https:\/\/doi.org\/10.1136\/neurintsurg-2014-011214","journal-title":"J Neurointerv Surg"},{"issue":"2\u20133","key":"6392_CR31","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/j.wneu.2010.05.008","volume":"74","author":"M Tremmel","year":"2010","unstructured":"Tremmel M, Xiang J, Natarajan SK et al (2010) Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents. World Neurosurg 74(2\u20133):306\u2013315. https:\/\/doi.org\/10.1016\/j.wneu.2010.05.008","journal-title":"World Neurosurg"},{"issue":"2","key":"6392_CR32","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1177\/15910199211023650","volume":"28","author":"TG White","year":"2022","unstructured":"White TG, Ryu B, Shah KA et al (2022) Quantitative magnetic resonance angiography to assess post embolization hemodynamics following pipeline embolization. Interv Neuroradiol 28(2):177\u2013182. https:\/\/doi.org\/10.1177\/15910199211023650","journal-title":"Interv Neuroradiol"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-024-06392-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00701-024-06392-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-024-06392-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T11:11:19Z","timestamp":1739358679000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00701-024-06392-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,9]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6392"],"URL":"https:\/\/doi.org\/10.1007\/s00701-024-06392-5","relation":{},"ISSN":["0942-0940"],"issn-type":[{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,9]]},"assertion":[{"value":"25 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"IRB or ethical approval was not necessary, as the project did not involve human subjects or animals.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}],"article-number":"8"}}