{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T17:24:46Z","timestamp":1758043486197,"version":"3.44.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T00:00:00Z","timestamp":1757635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T00:00:00Z","timestamp":1757635200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Augmented Reality (AR) is an emerging technology in the field of neurosurgery. It allows surgeons to view three-dimensional (3D) patient anatomy overlaid onto the surgical field in real time. In this technical report, we describe the preoperative and intraoperative use of the Hoth AR system for resection of a thoracic meningioma.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Prior to surgery, the 3D model of the patient\u2019s tumor and surrounding anatomy is rendered from the patient\u2019s preoperative imaging, and it is uploaded into the AR headset. Once the patient is positioned in the operating room, registration is performed by tracing reference points on the skin while wearing the headset. The surgeon wears the headset while operating, and they can toggle on\u2013off and transparency of each component of the model using voice commands to best visualize the 3D rendering overlaid on the patient\u2019s anatomy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>We provide a video case demonstrating the use of the Hoth AR system for resection of a thoracic meningioma. The system was able to register the model to the patient accurately in under 30\u00a0s. It was used to accurately plan the incision preoperatively, determine levels for laminectomy intraoperatively, and for precise localization of the tumor prior to opening the dura.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>This case describes the clinical integration of\u00a0a novel AR system for preoperative localization and intraoperative visualization during a resection of a thoracic meningioma. As AR systems continue to evolve and become more accessible, they are poised to become a standard tool in the surgical arsenal.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1007\/s00701-025-06659-5","type":"journal-article","created":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T07:17:05Z","timestamp":1757661425000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Resection of thoracic meningioma with hoth augmented reality system: technical note and operative video"],"prefix":"10.1007","volume":"167","author":[{"given":"Naser","family":"Ibrahim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuhei","family":"Shiino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen","family":"Shapiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Janssen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aaron","family":"Dumont","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,12]]},"reference":[{"issue":"7","key":"6659_CR1","doi-asserted-by":"publisher","first-page":"1580","DOI":"10.1007\/s00586-019-06054-6","volume":"29","author":"P Auloge","year":"2020","unstructured":"Auloge P, Cazzato RL, Ramamurthy N et al (2020) Augmented reality and artificial intelligence-based navigation during percutaneous vertebroplasty: a pilot randomised clinical trial. Eur Spine J 29(7):1580\u20131589. https:\/\/doi.org\/10.1007\/s00586-019-06054-6","journal-title":"Eur Spine J"},{"issue":"3","key":"6659_CR2","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1007\/s00701-021-04708-3","volume":"163","author":"G Burstr\u00f6m","year":"2021","unstructured":"Burstr\u00f6m G, Persson O, Edstr\u00f6m E, Elmi-Terander A (2021) Augmented reality navigation in spine surgery: a systematic review. Acta Neurochir 163(3):843\u2013852. https:\/\/doi.org\/10.1007\/s00701-021-04708-3","journal-title":"Acta Neurochir"},{"issue":"7","key":"6659_CR3","doi-asserted-by":"publisher","first-page":"1697","DOI":"10.1007\/s00586-019-05969-4","volume":"28","author":"B Carl","year":"2019","unstructured":"Carl B, Bopp M, Sa\u00df B, Voellger B, Nimsky C (2019) Implementation of augmented reality support in spine surgery. Eur Spine J 28(7):1697\u20131711. https:\/\/doi.org\/10.1007\/s00586-019-05969-4","journal-title":"Eur Spine J"},{"key":"6659_CR4","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2021.657901","volume":"8","author":"F Cofano","year":"2021","unstructured":"Cofano F, Di Perna G, Bozzaro M et al (2021) Augmented reality in medical practice: from spine surgery to remote assistance. Front Surg 8:657901. https:\/\/doi.org\/10.3389\/fsurg.2021.657901","journal-title":"Front Surg"},{"key":"6659_CR5","doi-asserted-by":"publisher","unstructured":"Costa F, Cardia A, Ortolina A, Fabio G, Zerbi A, Fornari M (2011) Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: radiological and clinical study in 100 consecutive patients.\u00a0Spine (Phila Pa 1976) 36(24):2094\u20132098. https:\/\/doi.org\/10.1097\/BRS.0b013e318201129d","DOI":"10.1097\/BRS.0b013e318201129d"},{"issue":"1","key":"6659_CR6","doi-asserted-by":"publisher","first-page":"E45","DOI":"10.1097\/BRS.0000000000003197","volume":"45","author":"E Edstr\u00f6m MD, PhD","year":"2020","unstructured":"Edstr\u00f6m E MD, PhD, Burstr\u00f6m G MD, Omar A PhD, Nachabe R PhD, S\u00f6derman M MD, PhD, Persson O MD, Gerdhem P MD, PhD, Elmi-Terander A MD, PhD (2020) Augmented reality surgical navigation in spine surgery to minimize staff radiation exposure. Spine 45(1):E45\u2013E53. https:\/\/doi.org\/10.1097\/BRS.0000000000003197","journal-title":"Spine"},{"issue":"10","key":"6659_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59101721","volume":"59","author":"G Hey","year":"2023","unstructured":"Hey G, Guyot M, Carter A, Lucke-Wold B (2023) Augmented reality in neurosurgery: a new paradigm for training. Medicina (Kaunas) 59(10):1721. https:\/\/doi.org\/10.3390\/medicina59101721","journal-title":"Medicina (Kaunas)"},{"issue":"4","key":"6659_CR8","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.57717","volume":"16","author":"R Hunt","year":"2024","unstructured":"Hunt R, Scarpace L, Rock JP (2024) Intraoperative Augmented Reality for Complex Glioma Resection: A Case Report. Cureus 16(4):e57717. https:\/\/doi.org\/10.7759\/cureus.57717","journal-title":"Cureus"},{"key":"6659_CR9","doi-asserted-by":"publisher","first-page":"e617","DOI":"10.1016\/j.wneu.2018.07.222","volume":"119","author":"C Karmonik","year":"2018","unstructured":"Karmonik C, Elias SN, Zhang JY et al (2018) Augmented reality with virtual cerebral aneurysms: a feasibility study. World Neurosurg 119:e617\u2013e622. https:\/\/doi.org\/10.1016\/j.wneu.2018.07.222","journal-title":"World Neurosurg"},{"issue":"2","key":"6659_CR10","doi-asserted-by":"publisher","first-page":"316","DOI":"10.3171\/2020.6.spine20370","volume":"34","author":"CA Molina","year":"2021","unstructured":"Molina CA, Phillips FM, Colman MW et al (2021) A cadaveric precision and accuracy analysis of augmented reality\u2013mediated percutaneous pedicle implant insertion: presented at the 2020 AANS\/CNS Joint Section on Disorders of the Spine and Peripheral Nerves. J Neurosurg Spine 34(2):316\u2013324. https:\/\/doi.org\/10.3171\/2020.6.spine20370","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"6659_CR11","doi-asserted-by":"publisher","first-page":"139","DOI":"10.3171\/2018.12.spine181142","volume":"31","author":"CA Molina","year":"2019","unstructured":"Molina CA, Theodore N, Ahmed AK et al (2019) Augmented reality\u2013assisted pedicle screw insertion: a cadaveric proof-of-concept study. J Neurosurg Spine 31(1):139\u2013146. https:\/\/doi.org\/10.3171\/2018.12.spine181142","journal-title":"J Neurosurg Spine"},{"key":"6659_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jocn.2016.09.002","volume":"35","author":"PE Pelargos","year":"2017","unstructured":"Pelargos PE, Nagasawa DT, Lagman C et al (2017) Utilizing virtual and augmented reality for educational and clinical enhancements in neurosurgery. J Clin Neurosci 35:1\u20134. https:\/\/doi.org\/10.1016\/j.jocn.2016.09.002","journal-title":"J Clin Neurosci"},{"key":"6659_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/cancers14092302","author":"M Pojski\u0107","year":"2022","unstructured":"Pojski\u0107 M, Bopp MHA, Sa\u03b2 B, Carl B, Nimsky C (2022) Microscope-based augmented reality with intraoperative computed tomography-based navigation for resection of skull base meningiomas in consecutive series of 39 patients. Cancers (Basel). https:\/\/doi.org\/10.3390\/cancers14092302","journal-title":"Cancers (Basel)"},{"issue":"4","key":"6659_CR14","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1007\/s00264-009-0792-3","volume":"33","author":"NF Tian","year":"2009","unstructured":"Tian NF, Xu HZ (2009) Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop 33(4):895\u2013903. https:\/\/doi.org\/10.1007\/s00264-009-0792-3","journal-title":"Int Orthop"},{"issue":"3","key":"6659_CR15","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1770","volume":"13","author":"JW Yoon","year":"2017","unstructured":"Yoon JW, Chen RE, Han PK, Si P, Freeman WD, Pirris SM (2017) Technical feasibility and safety of an intraoperative head-up display device during spine instrumentation. The International Journal of Medical Robotics and Computer Assisted Surgery 13(3):e1770. https:\/\/doi.org\/10.1002\/rcs.1770","journal-title":"The International Journal of Medical Robotics and Computer Assisted Surgery"},{"key":"6659_CR16","doi-asserted-by":"publisher","unstructured":"Xu AL, Covarrubias OG, Yakkanti RR, Sotsky RB, Aiyer AA (2023) The Biomechanical Burden of Orthopaedic Procedures and Musculoskeletal Injuries Sustained by Orthopaedic Surgeons: A Systematic Review. JBJS Rev 11(1). https:\/\/doi.org\/10.2106\/jbjs.rvw.22.00202","DOI":"10.2106\/jbjs.rvw.22.00202"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-025-06659-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00701-025-06659-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-025-06659-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T07:17:06Z","timestamp":1757661426000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00701-025-06659-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,12]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6659"],"URL":"https:\/\/doi.org\/10.1007\/s00701-025-06659-5","relation":{},"ISSN":["0942-0940"],"issn-type":[{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,12]]},"assertion":[{"value":"13 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest or financial disclosures. No funds, grants, or other support was received.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"Informed consent was obtained from all individual participants included in the study. The patient consented to the publication of their image.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}],"article-number":"243"}}