{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T20:23:10Z","timestamp":1790194990490,"version":"4.1.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T00:00:00Z","timestamp":1766188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T00:00:00Z","timestamp":1766361600000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Frankfurt"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Acta Neurochir"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Radiolucent carbon fiber-reinforced PEEK (CFRP) pedicle screws have improved imaging and radiation planning in spine oncology. However, these benefits are often limited by titanium cages used in combination. This study reports our initial experience using novel CFRP cages in oncologic spine surgeries, comparing their surgical feasibility, complications, and imaging performance to titanium cages.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We retrospectively analyzed 13 patients who received CFRP cages between July 2021 and May 2023. Clinical, surgical, follow-up, and imaging data were evaluated. A matched cohort with titanium cages was used to assess postoperative MRI visibility of anatomical landmarks, rated by independent reviewers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Thirteen CFRP cages were implanted (mean age 61\u2009\u00b1\u200911\u00a0years; 54% female). Indications included spinal metastases (54%) and primary bone tumors. Most procedures involved the thoracic spine (62%), followed by lumbar (23%) and cervical (15%). Median instrumentation spanned 4 segments; 62% had two-staged surgeries. Three complications occurred: 1 cage dislocation (requiring revision), 1 wound infection, and 1 post-incisional hernia. Median radiologic follow-up was 74\u00a0days, with no further dislocations. Postoperative MRI showed significantly better visibility of key spinal landmarks with CFRP cages versus titanium (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u2009.05, Wilcoxon signed-rank test).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>CFRP cages are a viable alternative to titanium in oncologic spine surgery, offering comparable usability and improved postoperative imaging. These advantages may support better radiotherapy planning and complication detection, warranting further investigation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00701-025-06739-6","type":"journal-article","created":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T14:06:20Z","timestamp":1766239580000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Use of carbon fiber-reinforced PEEK cages in spinal oncology patients: An institutional experience with emphasis on surgical, complication and imaging characteristics"],"prefix":"10.1007","volume":"167","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1514-1442","authenticated-orcid":false,"given":"Stefanos","family":"Voglis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lina-Elisabeth","family":"Qasem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonhard","family":"Mann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatma","family":"Kilinc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Jussen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Setzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fee","family":"Keil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent","family":"Prinz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Czabanka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,20]]},"reference":[{"key":"6739_CR1","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.jocn.2020.03.013","volume":"75","author":"F Cofano","year":"2020","unstructured":"Cofano F, Di Perna G, Monticelli M et al (2020) Carbon fiber reinforced vs titanium implants for fixation in spinal metastases: a comparative clinical study about safety and effectiveness of the new \u201ccarbon-strategy.\u201d J Clin Neurosci 75:106\u2013111. https:\/\/doi.org\/10.1016\/j.jocn.2020.03.013","journal-title":"J Clin Neurosci"},{"key":"6739_CR2","doi-asserted-by":"publisher","DOI":"10.3171\/2024.10.SPINE24753","author":"V Hubertus","year":"2025","unstructured":"Hubertus V, Wagner A, Albrecht C et al (2025) Carbon fiber-reinforced PEEK implants in oncologic spine surgery: a multicenter experience on implications for postoperative patient management. J Neurosurg Spine. https:\/\/doi.org\/10.3171\/2024.10.SPINE24753","journal-title":"J Neurosurg Spine"},{"issue":"21","key":"6739_CR3","doi-asserted-by":"publisher","DOI":"10.3390\/cancers14215275","volume":"14","author":"AK Joerger","year":"2022","unstructured":"Joerger AK, Seitz S, Lange N et al (2022) CFR-PEEK pedicle screw instrumentation for spinal neoplasms: a single center experience on safety and efficacy. Cancers 14(21):5275. https:\/\/doi.org\/10.3390\/cancers14215275","journal-title":"Cancers"},{"issue":"1","key":"6739_CR4","doi-asserted-by":"publisher","first-page":"2414","DOI":"10.1038\/s41598-021-81960-8","volume":"11","author":"AK Joerger","year":"2021","unstructured":"Joerger AK, Shiban E, Krieg SM, Meyer B (2021) Carbon-fiber reinforced PEEK instrumentation for spondylodiscitis: a single center experience on safety and efficacy. Sci Rep 11(1):2414. https:\/\/doi.org\/10.1038\/s41598-021-81960-8","journal-title":"Sci Rep"},{"key":"6739_CR5","doi-asserted-by":"publisher","DOI":"10.3171\/2023.5.SPINE23106","author":"HA Khan","year":"2023","unstructured":"Khan HA, Ber R, Neifert SN et al (2023) Carbon fiber\u2013reinforced PEEK spinal implants for primary and metastatic spine tumors: a systematic review on implant complications and radiotherapy benefits. J Neurosurg Spine. https:\/\/doi.org\/10.3171\/2023.5.SPINE23106","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"6739_CR6","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s10143-020-01384-2","volume":"44","author":"T Kr\u00e4tzig","year":"2021","unstructured":"Kr\u00e4tzig T, Mende KC, Mohme M et al (2021) Carbon fiber\u2013reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg Rev 44(4):2163\u20132170. https:\/\/doi.org\/10.1007\/s10143-020-01384-2","journal-title":"Neurosurg Rev"},{"issue":"2","key":"6739_CR7","doi-asserted-by":"publisher","DOI":"10.3390\/brainsci15020199","volume":"15","author":"FC Lam","year":"2025","unstructured":"Lam FC, Guru S, AbuReesh D et al (2025) Use of carbon fiber implants to improve the safety and efficacy of radiation therapy for spine tumor patients. Brain Sci 15(2):199. https:\/\/doi.org\/10.3390\/brainsci15020199","journal-title":"Brain Sci"},{"issue":"1","key":"6739_CR8","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159\u2013174","journal-title":"Biometrics"},{"issue":"5","key":"6739_CR9","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1097\/BSD.0000000000001007","volume":"34","author":"JM McDonnell","year":"2021","unstructured":"McDonnell JM, dos Nagassima Rodrigues Reis K, Ahern DP, Mahon J, Butler JS (2021) Are carbon-fiber implants more efficacious than traditional metallic implants for spine tumor surgery? Clin Spine Surg 34(5):159. https:\/\/doi.org\/10.1097\/BSD.0000000000001007","journal-title":"Clin Spine Surg"},{"issue":"8","key":"6739_CR10","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1002\/acm2.12905","volume":"21","author":"BS M\u00fcller","year":"2020","unstructured":"M\u00fcller BS, Ryang YM, Oechsner M et al (2020) The dosimetric impact of stabilizing spinal implants in radiotherapy treatment planning with protons and photons: standard titanium alloy vs. radiolucent carbon-fiber-reinforced PEEK systems. J Appl Clin Med Phys 21(8):6\u201314. https:\/\/doi.org\/10.1002\/acm2.12905","journal-title":"J Appl Clin Med Phys"},{"issue":"5","key":"6739_CR11","doi-asserted-by":"publisher","DOI":"10.3171\/2021.2.FOCUS20995","volume":"50","author":"MT Neal","year":"2021","unstructured":"Neal MT, Richards AE, Curley KL et al (2021) Carbon fiber\u2013reinforced PEEK instrumentation in the spinal oncology population: a retrospective series demonstrating technique, feasibility, and clinical outcomes. Neurosurg Focus 50(5):E13. https:\/\/doi.org\/10.3171\/2021.2.FOCUS20995","journal-title":"Neurosurg Focus"},{"key":"6739_CR12","unstructured":"R Core Team (n.d.) R: A language and environment for statistical computing. Published online 2024. https:\/\/www.r-project.org\/. Accessed\u00a001.07.2025"},{"key":"6739_CR13","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-023-05502-z","author":"M Schwendner","year":"2023","unstructured":"Schwendner M, Ille S, Kirschke JS et al (2023) Clinical evaluation of vertebral body replacement of carbon fiber\u2013reinforced polyetheretherketone in patients with tumor manifestation of the thoracic and lumbar spine. Acta Neurochir (Wien). https:\/\/doi.org\/10.1007\/s00701-023-05502-z","journal-title":"Acta Neurochir (Wien)"},{"key":"6739_CR14","unstructured":"Team RS (2020) RStudio: integrated development for R"},{"issue":"3","key":"6739_CR15","doi-asserted-by":"publisher","first-page":"323","DOI":"10.21037\/jss.2017.06.20","volume":"3","author":"G Tedesco","year":"2017","unstructured":"Tedesco G, Gasbarrini A, Bandiera S, Ghermandi R, Boriani S (2017) Composite PEEK\/Carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. J Spine Surg 3(3):323\u2013329. https:\/\/doi.org\/10.21037\/jss.2017.06.20","journal-title":"J Spine Surg"},{"key":"6739_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.xnsj.2022.100105","volume":"10","author":"AG Zavras","year":"2022","unstructured":"Zavras AG, Schoenfeld AJ, Patt JC et al (2022) Attitudes and trends in the use of radiolucent spinal implants: a survey of the North American Spine Society section of spinal oncology. North American Spine Society Journal (NASSJ) 10:100105. https:\/\/doi.org\/10.1016\/j.xnsj.2022.100105","journal-title":"North American Spine Society Journal (NASSJ)"}],"container-title":["Acta Neurochirurgica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00701-025-06739-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-025-06739-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00701-025-06739-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T06:30:00Z","timestamp":1766385000000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00701-025-06739-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,20]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6739"],"URL":"https:\/\/doi.org\/10.1007\/s00701-025-06739-6","relation":{},"ISSN":["0942-0940"],"issn-type":[{"value":"0942-0940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,20]]},"assertion":[{"value":"15 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted according to the guidelines of the local ethical committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}}],"article-number":"331"}}