{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T08:23:47Z","timestamp":1792225427497,"version":"4.4.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2017,10,13]],"date-time":"2017-10-13T00:00:00Z","timestamp":1507852800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Oral Invest"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1007\/s00784-017-2245-5","type":"journal-article","created":{"date-parts":[[2017,10,13]],"date-time":"2017-10-13T06:14:59Z","timestamp":1507875299000},"page":"1433-1437","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments"],"prefix":"10.1007","volume":"22","author":[{"given":"Amr","family":"Elnaghy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shaymaa","family":"Elsaka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,10,13]]},"reference":[{"key":"2245_CR1","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00004770-200003000-00008","volume":"26","author":"B Sattapan","year":"2000","unstructured":"Sattapan B, Nervo GJ, Palamara JE, Messer HH (2000) Defects in rotary nickel-titanium files after clinical use. J Endod 26:161\u2013165","journal-title":"J Endod"},{"key":"2245_CR2","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/j.1365-2591.2012.02036.x","volume":"45","author":"G Gambarini","year":"2012","unstructured":"Gambarini G, Gergi R, Naaman A, Osta N, Al Sudani D (2012) Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion. Int Endod J 45:802\u2013806","journal-title":"Int Endod J"},{"key":"2245_CR3","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1016\/j.joen.2008.05.007","volume":"34","author":"G Gambarini","year":"2008","unstructured":"Gambarini G, Grande NM, Plotino G, Somma F, Garala M, De Luca M, Testarelli L (2008) Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod 34:1003\u20131005","journal-title":"J Endod"},{"key":"2245_CR4","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1111\/j.1365-2591.2011.01957.x","volume":"45","author":"JL Gutmann","year":"2012","unstructured":"Gutmann JL, Gao Y (2012) Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review. Int Endod J 45:113\u2013128","journal-title":"Int Endod J"},{"key":"2245_CR5","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.1016\/j.joen.2014.06.011","volume":"40","author":"AM Elnaghy","year":"2014","unstructured":"Elnaghy AM, Elsaka SE (2014) Assessment of the mechanical properties of ProTaper Next nickel-titanium rotary files. J Endod 40:1830\u20131834","journal-title":"J Endod"},{"key":"2245_CR6","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1016\/j.joen.2015.02.030","volume":"41","author":"A Hieawy","year":"2015","unstructured":"Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y (2015) Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. J Endod 41:1134\u20131138","journal-title":"J Endod"},{"key":"2245_CR7","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.joen.2011.11.004","volume":"38","author":"Y Gao","year":"2012","unstructured":"Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D (2012) Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod 38:398\u2013401","journal-title":"J Endod"},{"key":"2245_CR8","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1016\/j.joen.2012.09.018","volume":"38","author":"Y Shen","year":"2012","unstructured":"Shen Y, Coil JM, Zhou HM, Tam E, Zheng YF, Haapasalo M (2012) ProFile Vortex instruments after clinical use: a metallurgical properties study. J Endod 38:1613\u20131617","journal-title":"J Endod"},{"key":"2245_CR9","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1016\/j.joen.2016.02.012","volume":"42","author":"Y Shen","year":"2016","unstructured":"Shen Y, Hieawy A, Huang X, Wang ZJ, Maezono H, Haapasalo M (2016) Fatigue resistance of a 3-dimensional conforming nickel-titanium rotary instrument in double curvatures. J Endod 42:961\u2013964","journal-title":"J Endod"},{"key":"2245_CR10","unstructured":"Dentsply Tulsa Dental Specialties (2015) TRUShape 3D confirming files brochure. Available at: \nhttp:\/\/www.tulsadentalspecialties.com\/Libraries\/Tab_Content_-_Endo_Access_Shaping\/TS_brochure_15.sflb.ashx"},{"key":"2245_CR11","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1007\/s00784-016-1917-x","volume":"21","author":"ME Kaval","year":"2017","unstructured":"Kaval ME, Capar ID, Ertas H, Sen BH (2017) Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties. Clin Oral Investig 21:1527\u20131530","journal-title":"Clin Oral Investig"},{"key":"2245_CR12","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.1016\/j.joen.2015.06.007","volume":"41","author":"OA Peters","year":"2015","unstructured":"Peters OA, Arias A, Paque F (2015) A micro-computed tomographic assessment of root canal preparation with a novel instrument, TRUShape, in mesial roots of mandibular molars. J Endod 41:1545\u20131550","journal-title":"J Endod"},{"key":"2245_CR13","unstructured":"FKG Dentaire (2016) The XP-endo shaper brochure. Available at: \nhttp:\/\/www.fkg.ch\/sites\/default\/files\/201612_fkg_XPS_brochure_v3_en_web.pdf"},{"key":"2245_CR14","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1111\/j.1365-2591.2007.01262.x","volume":"40","author":"GS Cheung","year":"2007","unstructured":"Cheung GS, Darvell BW (2007) Fatigue testing of a NiTi rotary instrument. Part 1: strain-life relationship. Int Endod J 40:612\u2013618","journal-title":"Int Endod J"},{"key":"2245_CR15","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.joen.2016.01.025","volume":"42","author":"RA Vasconcelos de","year":"2016","unstructured":"de Vasconcelos RA, Murphy S, Carvalho CA, Govindjee RG, Govindjee S, Peters OA (2016) Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J Endod 42:782\u2013787","journal-title":"J Endod"},{"key":"2245_CR16","doi-asserted-by":"publisher","unstructured":"Elnaghy AM, Elsaka SE (2016) Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne Gold and Reciproc reciprocating instruments. Int Endod J. \nhttps:\/\/doi.org\/10.1111\/iej.12712","DOI":"10.1111\/iej.12712"},{"key":"2245_CR17","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.joen.2012.10.025","volume":"39","author":"E Pedull\u00e0","year":"2013","unstructured":"Pedull\u00e0 E, Grande NM, Plotino G, Gambarini G, Rapisarda E (2013) Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 39:258\u2013261","journal-title":"J Endod"},{"key":"2245_CR18","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1111\/iej.12244","volume":"47","author":"AM Elnaghy","year":"2014","unstructured":"Elnaghy AM (2014) Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files. Int Endod J 47:1034\u20131039","journal-title":"Int Endod J"},{"key":"2245_CR19","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1016\/j.joen.2014.11.010","volume":"41","author":"AM Elnaghy","year":"2015","unstructured":"Elnaghy AM, Elsaka SE (2015) Torsion and bending properties of OneShape and WaveOne instruments. J Endod 41:544\u2013547","journal-title":"J Endod"},{"key":"2245_CR20","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1007\/s00784-015-1611-4","volume":"20","author":"HS Top\u00e7uo\u011flu","year":"2016","unstructured":"Top\u00e7uo\u011flu HS, Pala K, Akti A, D\u00fczg\u00fcn S, Top\u00e7uo\u011flu G (2016) Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite. Clin Oral Investig 20:1175\u20131179","journal-title":"Clin Oral Investig"},{"key":"2245_CR21","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1007\/s10266-015-0214-5","volume":"104","author":"A Jamleh","year":"2016","unstructured":"Jamleh A, Yahata Y, Ebihara A, Atmeh AR, Bakhsh T, Suda H (2016) Performance of NiTi endodontic instrument under different temperatures. Odontology 104:324\u2013328","journal-title":"Odontology"},{"key":"2245_CR22","doi-asserted-by":"crossref","first-page":"e106","DOI":"10.1016\/j.tripleo.2005.12.012","volume":"102","author":"TR Tripi","year":"2006","unstructured":"Tripi TR, Bonaccorso A, Condorelli GG (2006) Cyclic fatigue of different nickel-titanium endodontic rotary instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 102:e106\u2013e114","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"2245_CR23","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1016\/j.joen.2014.06.009","volume":"40","author":"M Tsujimoto","year":"2014","unstructured":"Tsujimoto M, Irifune Y, Tsujimoto Y, Yamada S, Watanabe I, Hayashi Y (2014) Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties. J Endod 40:1824\u20131829","journal-title":"J Endod"},{"key":"2245_CR24","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1111\/j.1365-2591.2006.01055.x","volume":"39","author":"K Miyai","year":"2006","unstructured":"Miyai K, Ebihara A, Hayashi Y, Doi H, Suda H, Yoneyama T (2006) Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments. Int Endod J 39:119\u2013126","journal-title":"Int Endod J"},{"key":"2245_CR25","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.joen.2012.11.005","volume":"39","author":"Y Shen","year":"2013","unstructured":"Shen Y, Zhou HM, Zheng YF, Peng B, Haapasalo M (2013) Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod 39:163\u2013172","journal-title":"J Endod"},{"key":"2245_CR26","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1016\/j.joen.2014.02.020","volume":"40","author":"G Plotino","year":"2014","unstructured":"Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G (2014) Blue treatment enhances cyclic fatigue resistance of Vortex nickel-titanium rotary files. J Endod 40:1451\u20131453","journal-title":"J Endod"},{"key":"2245_CR27","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1016\/j.joen.2013.12.033","volume":"40","author":"HH Nguyen","year":"2014","unstructured":"Nguyen HH, Fong H, Paranjpe A, Flake NM, Johnson JD, Peters OA (2014) Evaluation of the resistance to cyclic fatigue among ProTaper Next, ProTaper Universal, and Vortex Blue rotary instruments. J Endod 40:1190\u20131193","journal-title":"J Endod"},{"key":"2245_CR28","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1111\/j.1365-2591.2012.02067.x","volume":"45","author":"OA Peters","year":"2012","unstructured":"Peters OA, Gluskin AK, Weiss RA, Han JT (2012) An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments. Int Endod J 45:1027\u20131034","journal-title":"Int Endod J"},{"key":"2245_CR29","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s10266-012-0088-8","volume":"102","author":"G Plotino","year":"2014","unstructured":"Plotino G, Testarelli L, Al-Sudani D, Pongione G, Grande NM, Gambarini G (2014) Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study. Odontology 102:31\u201335","journal-title":"Odontology"},{"key":"2245_CR30","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1067\/mod.2001.112446","volume":"119","author":"M Santoro","year":"2001","unstructured":"Santoro M, Nicolay OF, Cangialosi TJ (2001) Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part I: temperature transitional ranges. Am J Orthod Dentofac Orthop 119:587\u2013593","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"2245_CR31","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1111\/iej.12700","volume":"50","author":"AM Elnaghy","year":"2017","unstructured":"Elnaghy AM, Elsaka SE (2017) Laboratory comparison of the mechanical properties of TRUShape with several nickel-titanium rotary instruments. Int Endod J 50:805\u2013812","journal-title":"Int Endod J"},{"key":"2245_CR32","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/j.joen.2016.03.010","volume":"42","author":"HS Top\u00e7uo\u011flu","year":"2016","unstructured":"Top\u00e7uo\u011flu HS, Top\u00e7uo\u011flu G, Akti A, D\u00fczg\u00fcn S (2016) In vitro comparison of cyclic fatigue resistance of ProTaper Next, HyFlex CM, OneShape, and ProTaper Universal instruments in a canal with a double curvature. J Endod 42:969\u2013971","journal-title":"J Endod"},{"key":"2245_CR33","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.joen.2015.01.011","volume":"41","author":"ST Seago","year":"2015","unstructured":"Seago ST, Bergeron BE, Kirkpatrick TC, Roberts MD, Roberts HW, Himel VT, Sabey KA (2015) Effect of repeated simulated clinical use and sterilization on the cutting efficiency and flexibility of Hyflex CM nickel-titanium rotary files. J Endod 41:725\u2013728","journal-title":"J Endod"},{"key":"2245_CR34","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1016\/j.joen.2011.08.005","volume":"37","author":"Y Shen","year":"2011","unstructured":"Shen Y, Zhou HM, Zheng YF, Campbell L, Peng B, Haapasalo M (2011) Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments. J Endod 37:1566\u20131571","journal-title":"J Endod"},{"key":"2245_CR35","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0099-2399(97)80250-6","volume":"23","author":"JP Pruett","year":"1997","unstructured":"Pruett JP, Clement DJ, Carnes DL Jr (1997) Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 23:77\u201385","journal-title":"J Endod"},{"key":"2245_CR36","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1016\/j.joen.2015.01.023","volume":"41","author":"O Higuera","year":"2015","unstructured":"Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE (2015) Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals. J Endod 41:913\u2013915","journal-title":"J Endod"}],"container-title":["Clinical Oral Investigations"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00784-017-2245-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-017-2245-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-017-2245-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,3,23]],"date-time":"2018-03-23T22:43:35Z","timestamp":1521845015000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00784-017-2245-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,13]]},"references-count":36,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["2245"],"URL":"https:\/\/doi.org\/10.1007\/s00784-017-2245-5","relation":{},"ISSN":["1432-6981","1436-3771"],"issn-type":[{"value":"1432-6981","type":"print"},{"value":"1436-3771","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,13]]}}}