{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:33:07Z","timestamp":1783384387363,"version":"3.54.6"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2018,2,13]],"date-time":"2018-02-13T00:00:00Z","timestamp":1518480000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Oral Invest"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1007\/s00784-018-2382-5","type":"journal-article","created":{"date-parts":[[2018,2,13]],"date-time":"2018-02-13T10:46:25Z","timestamp":1518518785000},"page":"2975-2980","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study"],"prefix":"10.1007","volume":"22","author":[{"given":"K.","family":"Y\u0131lmaz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3176-1251","authenticated-orcid":false,"given":"G.","family":"Uslu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"\u00d6zy\u00fcrek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,2,13]]},"reference":[{"key":"2382_CR1","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1046\/j.1365-2591.2000.00339.x","volume":"33","author":"SA Thompson","year":"2000","unstructured":"Thompson SA (2000) An overview of nickel\u2013titanium alloys used in dentistry. Int Endod J 33:297\u2013310","journal-title":"Int Endod J"},{"key":"2382_CR2","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1097\/01.DON.0000129039.59003.9D","volume":"30","author":"OA Peters","year":"2000","unstructured":"Peters OA (2000) Current challenges and concepts in the preparation of root canal systems: a review. J Endod 30:559\u2013567","journal-title":"J Endod"},{"key":"2382_CR3","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1111\/j.1365-2591.2010.01835.x","volume":"44","author":"G Gambarini","year":"2011","unstructured":"Gambarini G, Plotino G, Grande NM, Al-Sudani D, De Luca M, Testarelli L (2011) Mechanical properties of nickel\u2013titanium rotary instruments produced with a new manufacturing technique. Int Endod J 44:337\u2013341","journal-title":"Int Endod J"},{"key":"2382_CR4","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.joen.2012.11.005","volume":"39","author":"Y Shen","year":"2013","unstructured":"Shen Y, Zhou HM, Zheng YF, Peng B, Haapasalo M (2013) Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod 39:163\u2013172","journal-title":"J Endod"},{"key":"2382_CR5","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1016\/j.joen.2014.03.007","volume":"40","author":"LCM Braga","year":"2014","unstructured":"Braga LCM, Silva ACF, Buono VTL, de Azevedo Bahia MG (2014) Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments. J Endod 40:1494\u20131497","journal-title":"J Endod"},{"key":"2382_CR6","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s10266-012-0088-8","volume":"102","author":"G Plotino","year":"2014","unstructured":"Plotino G, Testarelli L, Al-Sudani D, Pongione G, Grande NM, Gambarini G (2014) Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study. Odontology 102:31\u201335","journal-title":"Odontology"},{"key":"2382_CR7","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1111\/iej.12620","volume":"50","author":"F Iacono","year":"2016","unstructured":"Iacono F, Pirani C, Generali L et al (2016) Structural analysis of HyFlex EDM instruments. Int Endod J 50:303\u2013313","journal-title":"Int Endod J"},{"key":"2382_CR8","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1016\/j.ijmachtools.2006.08.026","volume":"47","author":"NM Abbas","year":"2007","unstructured":"Abbas NM, Solomon DG, Bahari MF (2007) A review on current research trends in electrical discharge machining (EDM). Int J Mach Tool Manu 47:1214\u20131228","journal-title":"Int J Mach Tool Manu"},{"key":"2382_CR9","doi-asserted-by":"crossref","first-page":"3095","DOI":"10.1016\/S1452-3981(23)14376-8","volume":"8","author":"S Daneshmand","year":"2013","unstructured":"Daneshmand S, Kahrizi EF, Abedi E, Abdolhosseini MM (2013) Influence of machining parameters on electro discharge machining of NiTi shape memory alloys. Int J Electrochem Sci 8:3095\u20133104","journal-title":"Int J Electrochem Sci"},{"key":"2382_CR10","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1111\/iej.12470","volume":"49","author":"C Pirani","year":"2016","unstructured":"Pirani C, Iacono F, Generali L, Sassatelli P, Nucci C, Lusvarghi L, Gandolfi MG, Prati C (2016) HyFlex EDM: superficial features, metallurgical analysis and fatigue resistance of innovative electro discharge machined NiTi rotary instruments. Int Endod J 49:483\u2013493","journal-title":"Int Endod J"},{"key":"2382_CR11","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1111\/j.1365-2591.2012.02088.x","volume":"45","author":"G Spagnuolo","year":"2012","unstructured":"Spagnuolo G, Ametrano G, D'ant\u00f2 V et al (2012) Effect of autoclaving on the surfaces of TiN-coated and conventional nickel\u2013titanium rotary instruments. Int Endod J 45:1148\u20131155","journal-title":"Int Endod J"},{"key":"2382_CR12","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1111\/iej.12550","volume":"49","author":"D Zhao","year":"2015","unstructured":"Zhao D, Shen Y, Peng B, Haapasalo M (2015) Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated nickel\u2013titanium instruments. Int Endod J 49:990\u2013995","journal-title":"Int Endod J"},{"key":"2382_CR13","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1016\/j.joen.2011.07.008","volume":"37","author":"RB Casper","year":"2011","unstructured":"Casper RB, Roberts HW, Roberts MD, Himel VT, Bergeron BE (2011) Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems. J Endod 37:1572\u20131575","journal-title":"J Endod"},{"key":"2382_CR14","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.joen.2008.02.028","volume":"34","author":"CR Valois","year":"2008","unstructured":"Valois CR, Silva LP, Azevedo RB (2008) Multiple autoclave cycles affect the surface of rotary nickel-titanium files: an atomic force microscopy study. J Endod 34:859\u2013862","journal-title":"J Endod"},{"key":"2382_CR15","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1097\/01.DON.0000132301.87637.4A","volume":"31","author":"SB Alapati","year":"2005","unstructured":"Alapati SB, Brantley WA, Svec TA, Powers JM, Nusstein JM, Daehn GS (2005) SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical use. J Endod 31:40\u201343","journal-title":"J Endod"},{"key":"2382_CR16","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1097\/01.don.0000164132.27285.2c","volume":"31","author":"CR Valois","year":"2005","unstructured":"Valois CR, Silva LP, Azevedo RB (2005) Atomic force microscopy study of stainless-steel and nickel-titanium files. J Endod 31:882\u2013885","journal-title":"J Endod"},{"key":"2382_CR17","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/j.tripleo.2007.11.006","volume":"105","author":"O Topuz","year":"2008","unstructured":"Topuz O, Aydin C, Uzun O, Inan U, Alacam T, Tunca YM (2008) Structural effects of sodium hypochlorite solution on RaCe rotary nickel-titanium instruments: an atomic force microscopy study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:661\u2013665","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"2382_CR18","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1111\/iej.12189","volume":"47","author":"DM Fayyad","year":"2014","unstructured":"Fayyad DM, Mahran AH (2014) Atomic force microscopic evaluation of nanostructure alterations of rotary NiTi instruments after immersion in irrigating solutions. Int Endod J 47:567\u2013573","journal-title":"Int Endod J"},{"key":"2382_CR19","doi-asserted-by":"publisher","first-page":"462","DOI":"10.4103\/0972-0707.139842","volume":"17","author":"PS Prasad","year":"2014","unstructured":"Prasad PS, Sam JE, Arvind Kumar K (2014) The effect of 5% sodium hypochlorite, 17% EDTA and triphala on two different rotary Ni-Ti instruments: an AFM and EDS analysis. J Conserv Dent 17:462\u2013466","journal-title":"J Conserv Dent"},{"key":"2382_CR20","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.joen.2011.10.017","volume":"38","author":"G Plotino","year":"2012","unstructured":"Plotino G, Costanzo A, Grande NM, Petrovic R, Testarelli L, Gambarini G (2012) Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. J Endod 38:222\u2013225","journal-title":"J Endod"},{"key":"2382_CR21","unstructured":"ColteneEndo HyFlex EDM Brochure. Available at: https:\/\/www.coltene.com\/fileadmin\/Data\/EN\/Products\/Endodontics\/Root_Canal_Shaping\/HyFlex_EDM\/31328A_HyFlexEDM_Brochure_US.pdf . Accessed 15 June 2017"},{"key":"2382_CR22","unstructured":"ColteneEndo HyFlex CM Brochure. Available at: http:\/\/www.hyflexcm.com\/DevDownloads\/HyFlexFamily_bro.pdf . Accessed 15 June 2017"},{"key":"2382_CR23","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1111\/j.1365-2591.2012.02067.x","volume":"45","author":"OA Peters","year":"2012","unstructured":"Peters OA, Gluskin AK, Weiss RA, Han JT (2012) An in vitro assessment of the physical properties of novel Hyflex nickel\u2013titanium rotary instruments. Int Endod J 45:1027\u20131034","journal-title":"Int Endod J"},{"key":"2382_CR24","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1111\/iej.12049","volume":"46","author":"Y Shen","year":"2013","unstructured":"Shen Y, Coil JM, Zhou H, Zheng Y, Haapasalo M (2013) HyFlex nickel\u2013titanium rotary instruments after clinical use: metallurgical properties. Int Endod J 46:720\u2013729","journal-title":"Int Endod J"},{"key":"2382_CR25","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1111\/iej.12353","volume":"48","author":"M Alfoqom Alazemi","year":"2015","unstructured":"Alfoqom Alazemi M, Bryant ST, Dummer PMH (2015) Deformation of HyFlex CM instruments and their shape recovery following heat sterilization. Int Endod J 48:593\u2013601","journal-title":"Int Endod J"},{"key":"2382_CR26","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1111\/j.1365-2591.2006.01147.x","volume":"39","author":"G Alexandrou","year":"2006","unstructured":"Alexandrou G, Chrissafis K, Vasiliadis L, Pavlidou E, Polychroniadis EK (2006) Effect of heat sterilization on surface characteristics and microstructure of Mani NRT rotary nickel\u2013titanium instruments. Int Endod J 39:770\u2013778","journal-title":"Int Endod J"},{"key":"2382_CR27","doi-asserted-by":"publisher","first-page":"218","DOI":"10.4103\/0972-0707.157256","volume":"18","author":"AS Nair","year":"2015","unstructured":"Nair AS, Tilakchand M, Naik BD (2015) The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: an in vitro atomic force microscopy investigation. J Conserv Dent 18:218\u2013222","journal-title":"J Conserv Dent"},{"key":"2382_CR28","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1111\/j.0022-2720.2005.01414.x","volume":"217","author":"J Cazaux","year":"2005","unstructured":"Cazaux J (2005) Recent developments and new strategies in scanning electron microscopy. J Microsc 217:16\u201335","journal-title":"J Microsc"},{"key":"2382_CR29","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1002\/jemt.22325","volume":"77","author":"Y Fatma","year":"2014","unstructured":"Fatma Y, Ozgur U (2014) Evaluation of surface topography changes in three NiTi file systems using rotary and reciprocal motion: an atomic force microscopy study. Microsc Res Tech 77:177\u2013182","journal-title":"Microsc Res Tech"},{"key":"2382_CR30","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1111\/iej.12676","volume":"50","author":"JJ Cai","year":"2017","unstructured":"Cai JJ, Tang XN, Ge JY (2017) Effect of irrigation on surface roughness and fatigue resistance of controlled memory wire nickel-titanium instruments. Int Endod J 50:718\u2013724","journal-title":"Int Endod J"},{"key":"2382_CR31","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.gien.2016.04.006","volume":"30","author":"F Iacono","year":"2016","unstructured":"Iacono F, Pirani C, Generali L, Sassatelli P, Nucci C, Gandolfi MG, Prati C (2016) Wear analysis and cyclic fatigue resistance of electro discharge machined NiTi rotary instruments. G Ital Endod 30:64\u201368","journal-title":"G Ital Endod"},{"key":"2382_CR32","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1016\/S0099-2399(99)80289-1","volume":"25","author":"C Eggert","year":"1999","unstructured":"Eggert C, Peters O, Barbakow F (1999) Wear of nickel-titanium Lightspeed instruments evaluated by scanning electron microscopy. J Endod 25:494\u2013497","journal-title":"J Endod"},{"key":"2382_CR33","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.msea.2003.10.320","volume":"369","author":"KI Yokoyama","year":"2004","unstructured":"Yokoyama KI, Kaneko K, Yabuta E, Asaoka K, Sakai JI (2004) Fracture of nickel\u2013titanium superelastic alloy in sodium hypochlorite solution. Mater Sci Eng 369:43\u201348","journal-title":"Mater Sci Eng"},{"key":"2382_CR34","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/j.joen.2015.01.011","volume":"41","author":"ST Seago","year":"2015","unstructured":"Seago ST, Bergeron BE, Kirkpatrick TC, Roberts MD, Roberts HW, Himel VT, Sabey KA (2015) Effect of repeated simulated clinical use and sterilization on the cutting efficiency and flexibility of Hyflex CM nickel-titanium rotary files. J Endod 41:725\u2013728","journal-title":"J Endod"}],"container-title":["Clinical Oral Investigations"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00784-018-2382-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-018-2382-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-018-2382-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T23:39:32Z","timestamp":1693525172000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00784-018-2382-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2,13]]},"references-count":34,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["2382"],"URL":"https:\/\/doi.org\/10.1007\/s00784-018-2382-5","relation":{},"ISSN":["1432-6981","1436-3771"],"issn-type":[{"value":"1432-6981","type":"print"},{"value":"1436-3771","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2,13]]},"assertion":[{"value":"10 November 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 February 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"For this type of study, formal consent is not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}