{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T02:02:44Z","timestamp":1788228164151,"version":"build-2803163510"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,6,13]],"date-time":"2020-06-13T00:00:00Z","timestamp":1592006400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,13]],"date-time":"2020-06-13T00:00:00Z","timestamp":1592006400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Universitat Internacional de Catalunya"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Oral Invest"],"published-print":{"date-parts":[[2021,3]]},"DOI":"10.1007\/s00784-020-03398-y","type":"journal-article","created":{"date-parts":[[2020,6,12]],"date-time":"2020-06-12T21:02:10Z","timestamp":1591995730000},"page":"1047-1053","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["Influence of bone density, drill diameter, drilling speed, and irrigation on temperature changes during implant osteotomies: an in vitro study"],"prefix":"10.1007","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5883-1363","authenticated-orcid":false,"given":"Oscar","family":"Salom\u00f3-Coll","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beatriz","family":"Auriol-Muerza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naroa","family":"Lozano-Carrascal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Hern\u00e1ndez-Alfaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hom-Lay","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jordi","family":"Gargallo-Albiol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,13]]},"reference":[{"key":"3398_CR1","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/S0301-0503(81)80007-0","volume":"9","author":"A Schroeder","year":"1981","unstructured":"Schroeder A, Van Der Zypen E, Stich H, Sutter F (1981) The reaction of bone, connective tissue and epithelium to endosteal implants with sprayed titanium surfaces. J Maxillofac Surg 9:15\u201325","journal-title":"J Maxillofac Surg"},{"key":"3398_CR2","first-page":"1193","volume":"26","author":"AC Carvalho","year":"2011","unstructured":"Carvalho AC, Queiroz TP, Okamoto R, Margonar R, Garcia IR Jr, Magro Filho O (2011) Evaluation of bone heating, immediate bone cell viability, and wear of high-resistance drills after the creation of implant osteotomies in rabbit tibias. Int J Oral Maxillofac Implants 26:1193\u20131201","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3398_CR3","first-page":"127","volume":"14","author":"SH Tehemar","year":"1999","unstructured":"Tehemar SH (1999) Factors affecting heat generation during implant site preparation: a review of biologic observations and future considerations. Int J Oral Maxillofac Implants 14:127\u2013136","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3398_CR4","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1016\/j.bjoms.2015.05.004","volume":"53","author":"SC M\u00f6hlhenrich","year":"2015","unstructured":"M\u00f6hlhenrich SC, Modabber A, Steiner T, Mitchell DA, H\u00f6lzle F (2015) Heat generation and drill wear during dental implant site preparation: systematic review. Br J Oral Maxillofac Surg 53:679\u2013689","journal-title":"Br J Oral Maxillofac Surg"},{"key":"3398_CR5","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1111\/j.1600-0501.2007.01427.x","volume":"3","author":"RC Van Staden","year":"2008","unstructured":"Van Staden RC, Guan H, Johnson NW, Loo YC, Meredith N (2008) Step-wise analysis of the dental implant insertion process using the finite element technique. Clin Oral Implants Res 3:303\u2013313","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/17453677809005716","volume":"49","author":"T Albrektsson","year":"1978","unstructured":"Albrektsson T, Albrektsson B (1978) Microcirculation in grafted bone. A chamber technique for vital microscopy of rabbit bone transplant. Acta Orthop Scand 49:1\u20137","journal-title":"Acta Orthop Scand"},{"issue":"4","key":"3398_CR7","doi-asserted-by":"publisher","first-page":"795","DOI":"10.11607\/jomi.4485","volume":"31","author":"KP Almeida","year":"2016","unstructured":"Almeida KP, Delgado-Ruiz R, Carneiro LG, Leiva AB, Calvo-Guirado JL, G\u00f3mez-Moreno G, Malmstr\u00f6m H, Romanos GE (2016) Influence of drilling speed on stability of tapered dental implants: an ex vivo experimental study. Int J Oral Maxillofac Implants 31(4):795\u2013798","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3398_CR8","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1302\/0301-620X.78B4.0780584","volume":"78","author":"M Leunig","year":"1996","unstructured":"Leunig M, Hertel R (1996) Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases. J Bone Joint Surg Br 78:584\u2013587","journal-title":"J Bone Joint Surg Br"},{"key":"3398_CR9","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1111\/cid.12172","volume":"17","author":"SA Gehrke","year":"2015","unstructured":"Gehrke SA, Bettach R, Taschieri S, Boukhris G, Corbella S, Del Fabbro M (2015) Temperature changes in cortical bone after implant site preparation using a single bur versus multiple drilling steps: an in vitro investigation. Clin Implant Dent Relat Res 17:700\u2013707","journal-title":"Clin Implant Dent Relat Res"},{"key":"3398_CR10","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/0022-3913(83)90174-9","volume":"50","author":"AR Eriksson","year":"1983","unstructured":"Eriksson AR, Albrektsson T (1983) Temperature threshold levels for heat-induced bone tissue injury: a vital microscopic study in the rabbit. J Prosthet Dent 50:101\u2013107","journal-title":"J Prosthet Dent"},{"key":"3398_CR11","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/0278-2391(86)90006-6","volume":"44","author":"RA Eriksson","year":"1986","unstructured":"Eriksson RA, Adell R (1986) Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 44:4\u20137","journal-title":"J Oral Maxillofac Surg"},{"key":"3398_CR12","first-page":"1","volume":"0","author":"SA Gehrke","year":"2016","unstructured":"Gehrke SA, Aramburu JS (2016) The influence of drill length and irrigation system on heat production during osteotomy preparation for dental implants: an ex vivo study. Clin Oral Implants Res 0:1\u20137","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR13","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1016\/j.bjoms.2015.09.017","volume":"54","author":"A Pirjamalineisiani","year":"2015","unstructured":"Pirjamalineisiani A, Jamshidi N, Sarafbidabad M, Soltani N (2015) Assessment of experimental thermal, numerical, and mandibular drilling factors in implantology. Brit J Oral Max Surg 54:400\u2013404","journal-title":"Brit J Oral Max Surg"},{"key":"3398_CR14","first-page":"186","volume":"12","author":"G Cordioli","year":"1997","unstructured":"Cordioli G, Majzoub Z (1997) Heat generation during implant site preparation: an in vitro study. Int J Oral Maxillofac Implants 12:186\u2013193","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3398_CR15","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1111\/j.1600-0501.2010.02051.x","volume":"22","author":"HJ Oh","year":"2011","unstructured":"Oh HJ, Wikesj\u00f6 UM, Kang HS, Ku Y, Eom TG, Koo KT (2011) Effect of implant drill characteristics on heat generation in osteotomy sites: a pilot study. Clin Oral Implants Res 22:722\u2013726","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR16","first-page":"25","volume":"15","author":"F Karaca","year":"2013","unstructured":"Karaca F, Aksakal B (2013) Effects of various drilling parameters on bone during implantology: an in vitro experimental study. Acta Bioeng Biomech 15:25\u201332","journal-title":"Acta Bioeng Biomech"},{"key":"3398_CR17","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1111\/j.1600-0501.2011.02248.x","volume":"23","author":"N Oliveira","year":"2012","unstructured":"Oliveira N, Alaejos-Algarra F, Mareque-Bueno J, Ferr\u00e9s-Padr\u00f3 E, Hern\u00e1ndez-Alfaro F (2012) Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills. Clin Oral Implants Res 23:963\u2013969","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR18","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1016\/j.joms.2010.11.001","volume":"69","author":"M Sumer","year":"2011","unstructured":"Sumer M, Misir AF, Telcioglu NT, Guler AU, Yenisey M (2011) Comparison of heat generation during implant drilling using stainless steel and ceramic drills. J Oral Maxillofac Surg 69:1350\u20131354","journal-title":"J Oral Maxillofac Surg"},{"key":"3398_CR19","first-page":"335","volume":"19","author":"C Ercoli","year":"2004","unstructured":"Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN (2004) The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Int J Oral Maxillofac Implants 19:335\u2013349","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3398_CR20","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1034\/j.1600-0501.2000.110206.x","volume":"11","author":"RM Jochum","year":"2000","unstructured":"Jochum RM, Reichart PA (2000) Influence of multiple use of timedur-titanium cannon drills: termal response and scanning electron microscopic findings. Clin Oral Implants Res 11:139\u2013143","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR21","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1034\/j.1600-0501.1997.080305.x","volume":"8","author":"Y Reingewirtz","year":"1997","unstructured":"Reingewirtz Y, Szmukler-Moncler S, Senger B (1997) Influence of different parameters on bone heating and drilling time in implantology. Clin Oral Implants Res 8:189\u2013197","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR22","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1053\/joms.2002.34992","volume":"60","author":"M Sharawy","year":"2002","unstructured":"Sharawy M, Misch CE, Weller N, Tehemar S (2002) Heat generation during implant drilling: the significance of motor speed. J Oral Maxillofac Surg 60:1160\u20131169","journal-title":"J Oral Maxillofac Surg"},{"key":"3398_CR23","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1097\/00006123-200005000-00029","volume":"46","author":"S Kondo","year":"2000","unstructured":"Kondo S, Okada Y, Iseki H, Hori T, Takakura K, Kobayashi A, Nagata H (2000) Thermological study of drilling bone tissue with a high- speed drill. Neurosurgery 46:1162\u20131168","journal-title":"Neurosurgery"},{"key":"3398_CR24","doi-asserted-by":"publisher","first-page":"629","DOI":"10.3109\/17453678408992410","volume":"55","author":"RA Eriksson","year":"1984","unstructured":"Eriksson RA, Albrektsson T, Albrektsson B (1984) Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals. Acta Orthop Scand 55:629\u2013631","journal-title":"Acta Orthop Scand"},{"key":"3398_CR25","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1111\/clr.12709","volume":"27","author":"RA Delgado-Ruiz","year":"2016","unstructured":"Delgado-Ruiz RA, Sacks D, Palermo A, Calvo-Guirado JL, Perez-Albacete C, Romanos GE (2016) Temperature and time variations during osteotomies performed with different piezosurgical devices: an in vitro study. Clin Oral Implants Res 27:1137\u20131143","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR26","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1016\/j.bjoms.2012.10.023","volume":"51","author":"SA Gehrke","year":"2013","unstructured":"Gehrke SA, Loffredo Neto H, Mardegan FE (2013) Investigation of the effect of movement and irrigation on temperature in the drilling of cortical bone. Br J Oral Maxillofac Surg 51:953\u2013957","journal-title":"Br J Oral Maxillofac Surg"},{"key":"3398_CR27","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.joms.2005.10.011","volume":"64","author":"GE Chacon","year":"2006","unstructured":"Chacon GE, Bower DL, Larsen PE, McGlumphy EA, Beck FM (2006) Heat production by 3 implant drill systems after repeated drilling and sterilization. J Oral Maxillofac Surg 64:265\u2013269","journal-title":"J Oral Maxillofac Surg"},{"key":"3398_CR28","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1034\/j.1600-0501.2002.130309.x","volume":"13","author":"IC Benington","year":"2002","unstructured":"Benington IC, Biagioni PA, Briggs J, Sheridan S, Lamey PJ (2002) Thermal changes observed at implant sites during internal and external irrigation. Clin Oral Implants Res 13:293\u2013297","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR29","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1111\/j.1600-0501.2008.01643.x","volume":"20","author":"BC Sener","year":"2009","unstructured":"Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I (2009) Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin Oral Implants Res 20:294\u2013298","journal-title":"Clin Oral Implants Res"},{"key":"3398_CR30","doi-asserted-by":"publisher","first-page":"148","DOI":"10.3390\/jcm9010148","volume":"9","author":"A Scarano","year":"2020","unstructured":"Scarano A, Lorusso F, Noumbissi S (2020) Infrared thermographic evaluation of temperature modifications induced during implant site preparation with steel vs. zirconia implant drill. J Clin Med 9:148\u2013158","journal-title":"J Clin Med"},{"key":"3398_CR31","first-page":"405","volume":"46","author":"D Laurito","year":"2010","unstructured":"Laurito D, Lamazza L, Garreffa G, De Biase A (2010) An alternative method to record rising temperatures during implant site preparation: a preliminary study using bovine bone. Ann Ist Super Sanita 46:405\u2013410","journal-title":"Ann Ist Super Sanita"},{"key":"3398_CR32","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1111\/j.1708-8208.2003.tb00178.x","volume":"5","author":"CE Misch","year":"2003","unstructured":"Misch CE, Degidi M (2003) Five-year prospective study of immediate\/early loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system. Clin Implant Dent Relat Res 5:17\u201328","journal-title":"Clin Implant Dent Relat Res"},{"key":"3398_CR33","unstructured":"ASTM F1839\u201308 (2016) Standard specification for rigid polyurethane foam for use as a standard material for testing orthopaedic devices and instruments. ASTM International West Conshohocken. PA. www.astm.org. Accessed Sept 2019"}],"container-title":["Clinical Oral Investigations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-020-03398-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00784-020-03398-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-020-03398-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,12]],"date-time":"2021-06-12T19:39:01Z","timestamp":1623526741000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00784-020-03398-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,13]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["3398"],"URL":"https:\/\/doi.org\/10.1007\/s00784-020-03398-y","relation":{},"ISSN":["1432-6981","1436-3771"],"issn-type":[{"value":"1432-6981","type":"print"},{"value":"1436-3771","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,13]]},"assertion":[{"value":"5 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"For this type of study, formal consent is not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}