{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T21:24:09Z","timestamp":1793827449514,"version":"4.6.1"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,7,10]],"date-time":"2020-07-10T00:00:00Z","timestamp":1594339200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,7,10]],"date-time":"2020-07-10T00:00:00Z","timestamp":1594339200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100018936","name":"Universit\u00e4tsklinikum Heidelberg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018936","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Oral Invest"],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives<\/jats:title>\n                <jats:p>Conventional dental implants inserted in the molar region of the maxilla will reach into the sinus maxillaris when alveolar ridge height is limited. When surgery is performed without prior augmentation of the sinus floor, primary stability of the implant is important for successful osseointegration. This study aimed at identifying the impact of bone quality and quantity at the implantation site on primary implant stability of a simulated bicortical placement.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>In our in vitro measurements, bone mineral density, total bone thickness and overall cortical bone thickness were assessed by micro-computed tomography (\u03bcCT) of pig scapulae, which resembled well the bicortical situation found in human patients. Dental implants were inserted, and micromotion between bone and implant was measured while loading the implant with an axial torque.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The main findings were that primary implant stability did not depend on total bone thickness but tended to increase with either increasing bone mineral density or overall cortical bone thickness.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Clinical relevance<\/jats:title>\n                <jats:p>Limited bone height in the maxilla is a major problem when planning dental implants. To overcome this problem, several approaches, e.g. external or internal sinus floor elevation, have been established. When planning the insertion of a dental implant an important aspect is the primary stability which can be expected. With other factors, the dimensions of the cortical bone might be relevant in this context. It would, therefore, be helpful to define the minimum thickness of cortical bone required to achieve sufficient primary stability, thus avoiding additional surgical intervention.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00784-020-03432-z","type":"journal-article","created":{"date-parts":[[2020,7,10]],"date-time":"2020-07-10T17:03:31Z","timestamp":1594400611000},"page":"1265-1272","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Effect of bone quality and quantity on the primary stability of dental implants in a simulated bicortical placement"],"prefix":"10.1007","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9515-4405","authenticated-orcid":false,"given":"Stefan","family":"Rues","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Schmitter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefanie","family":"Kappel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Sonntag","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Philippe","family":"Kretzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Nadorf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,7,10]]},"reference":[{"key":"3432_CR1","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.actbio.2016.11.044","volume":"48","author":"G Sundell","year":"2017","unstructured":"Sundell G, Dahlin C, Andersson M, Thuvander M (2017) The bone-implant interface of dental implants in humans on the atomic scale. Acta Biomater 48:445\u2013450","journal-title":"Acta Biomater"},{"key":"3432_CR2","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1111\/j.1708-8208.2004.tb00027.x","volume":"6","author":"D O'Sullivan","year":"2004","unstructured":"O'Sullivan D, Sennerby L, Jagger D, Meredith N (2004) A comparison of two methods of enhancing implant primary stability. Clin Implant Dent Relat Res 6:48\u201357","journal-title":"Clin Implant Dent Relat Res"},{"key":"3432_CR3","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1111\/j.1708-8208.2000.tb00110.x","volume":"2","author":"D O'Sullivan","year":"2000","unstructured":"O'Sullivan D, Sennerby L, Meredith N (2000) Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res 2:85\u201392","journal-title":"Clin Implant Dent Relat Res"},{"key":"3432_CR4","first-page":"48","volume":"23","author":"A Sharan","year":"2008","unstructured":"Sharan A, Madjar D (2008) Maxillary sinus pneumatization following extractions: a radiographic study. Int J Oral Maxillofac Implants 23:48\u201356","journal-title":"Int J Oral Maxillofac Implants"},{"key":"3432_CR5","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1007\/s10561-015-9505-x","volume":"16","author":"K Krasny","year":"2015","unstructured":"Krasny K, Krasny M, Kaminski A (2015) Two-stage closed sinus lift: a new surgical technique for maxillary sinus floor augmentation. Cell Tissue Bank. 16:579\u2013585. https:\/\/doi.org\/10.1007\/s10561-015-9505-x","journal-title":"Cell Tissue Bank."},{"key":"3432_CR6","first-page":"257","volume":"8","author":"M Esposito","year":"2015","unstructured":"Esposito M, Barausse C, Pistilli R, Sammartino G, Grandi G, Felice P (2015) Short implants versus bone augmentation for placing longer implants in atrophic maxillae: one-year post-loading results of a pilot randomised controlled trial. Eur J Oral Implantol 8:257\u2013268","journal-title":"Eur J Oral Implantol"},{"key":"3432_CR7","doi-asserted-by":"publisher","first-page":"148","DOI":"10.4103\/2231-0746.119228","volume":"3","author":"SM Balaji","year":"2013","unstructured":"Balaji SM (2013) Direct v\/s indirect sinus lift in maxillary dental implants. Ann Maxillofac Surg 3:148\u2013153","journal-title":"Ann Maxillofac Surg"},{"issue":"Suppl 1","key":"3432_CR8","doi-asserted-by":"publisher","first-page":"e267","DOI":"10.1111\/cid.12138","volume":"17","author":"P Rammelsberg","year":"2015","unstructured":"Rammelsberg P, Mahabadi J, Eiffler C, Koob A, Kappel S, Gabbert O (2015) Radiographic monitoring of changes in bone height after implant placement in combination with an internal sinus lift without graft material. Clin Implant Dent Relat Res 17(Suppl 1):e267\u2013e274","journal-title":"Clin Implant Dent Relat Res"},{"key":"3432_CR9","doi-asserted-by":"publisher","first-page":"2885","DOI":"10.1016\/j.ultrasmedbio.2014.03.035","volume":"40","author":"R Vayron","year":"2014","unstructured":"Vayron R, Mathieu V, Michel A, Haiat G (2014) Assessment of in vitro dental implant primary stability using an ultrasonic method. Ultrasound Med Biol 40:2885\u20132894","journal-title":"Ultrasound Med Biol"},{"key":"3432_CR10","first-page":"1229","volume":"73","author":"W Schulte","year":"1983","unstructured":"Schulte W, d\u2019Hoedt B, Lukas D, Muhlbradt L, Scholz F, Bretschi J, Frey D, Gudat H, Konig M, Markl M (1983) Periotest\u2014a new measurement process for periodontal function. Zahn\u00e4rztl Mitt 73:1229\u20131230","journal-title":"Zahn\u00e4rztl Mitt"},{"key":"3432_CR11","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00784-007-0115-2","volume":"11","author":"A Rabel","year":"2007","unstructured":"Rabel A, Kohler SG, Schmidt-Westhausen AM (2007) Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 11:257\u2013265","journal-title":"Clin Oral Investig"},{"key":"3432_CR12","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1902\/jop.2007.060143","volume":"78","author":"P Valderrama","year":"2007","unstructured":"Valderrama P, Oates TW, Jones AA, Simpson J, Schoolfield JD, Cochran DL (2007) Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodontol 78:262\u2013272","journal-title":"J Periodontol"},{"key":"3432_CR13","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1111\/cid.12565","volume":"20","author":"FS Lages","year":"2018","unstructured":"Lages FS, Douglas-de Oliveira DW, Costa FO (2018) Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: a systematic review. Clin Implant Dent Relat Res 20:26\u201333","journal-title":"Clin Implant Dent Relat Res"},{"key":"3432_CR14","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1007\/s00264-013-2138-4","volume":"38","author":"W Pepke","year":"2014","unstructured":"Pepke W, Nadorf J, Ewerbeck V, Streit MR, Kinkel S, Gotterbarm T, Maier MW, Kretzer JP (2014) Primary stability of the Fitmore stem: biomechanical comparison. Int Orthop 38:483\u2013488","journal-title":"Int Orthop"},{"key":"3432_CR15","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0129149","volume":"10","author":"S Kinkel","year":"2015","unstructured":"Kinkel S, Nadorf J, Graage JD, Jakubowitz E, Kretzer JP (2015) Primary rotational stability of various megaprostheses in a biomechanical sawbone model with proximal femoral defects extending to the isthmus. PLoS One 10:e0129149","journal-title":"PLoS One"},{"key":"3432_CR16","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/1471-2474-13-33","volume":"13","author":"S Doebele","year":"2012","unstructured":"Doebele S, Siebenlist S, Vester H, Wolf P, Hagn U, Schreiber U, Stockle U, Lucke M (2012) New method for detection of complex 3D fracture motion--verification of an optical motion analysis system for biomechanical studies. BMC Musculoskelet Disord 13:33","journal-title":"BMC Musculoskelet Disord"},{"key":"3432_CR17","doi-asserted-by":"publisher","first-page":"683","DOI":"10.12998\/wjcc.v2.i11.683","volume":"2","author":"JE Lee","year":"2014","unstructured":"Lee JE, Jin SH, Ko Y, Park JB (2014) Evaluation of anatomical considerations in the posterior maxillae for sinus augmentation. World J Clin Cases 2:683\u2013688","journal-title":"World J Clin Cases"},{"key":"3432_CR18","doi-asserted-by":"publisher","unstructured":"Coopman R, Fennis J, Ghaeminia H, Van de Vyvere G, Politis C, Hoppenreijs TJM (2020) Volumetric osseous changes in the completely edentulous maxilla after sinus grafting and lateral bone augmentation: a systematic review. Int J Oral Maxillofac Surg. https:\/\/doi.org\/10.1016\/j.ijom.2020.03.001","DOI":"10.1016\/j.ijom.2020.03.001"},{"key":"3432_CR19","doi-asserted-by":"publisher","first-page":"11","DOI":"10.4103\/jips.jips_244_18","volume":"20","author":"JN Palaskar","year":"2020","unstructured":"Palaskar JN, Joshi N, Shah PM, Gullapalli P, Vinay V (2020) Influence of different implant placement techniques to improve primary implant stability in low-density bone: a systematic review. J Indian Prosthodont Soc 20:11\u201316","journal-title":"J Indian Prosthodont Soc"},{"key":"3432_CR20","first-page":"162","volume":"5","author":"F Javed","year":"2013","unstructured":"Javed F, Ahmed HB, Crespi R, Romanos GE (2013) Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation. Interv Med Appl Sci 5:162\u2013167","journal-title":"Interv Med Appl Sci"},{"key":"3432_CR21","first-page":"88","volume":"38","author":"G Greenstein","year":"2017","unstructured":"Greenstein G, Cavallaro J (2017) Implant insertion torque: its role in achieving primary stability of restorable dental implants. Compend Contin Educ Dent 38:88\u201395","journal-title":"Compend Contin Educ Dent"},{"key":"3432_CR22","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/j.cden.2019.02.001","volume":"63","author":"M Al-Sabbagh","year":"2019","unstructured":"Al-Sabbagh M, Eldomiaty W, Khabbaz Y (2019) Can osseointegration be achieved without primary stability? Dent Clin North Am 63:461\u2013473","journal-title":"Dent Clin North Am"},{"key":"3432_CR23","first-page":"485","volume":"49","author":"V Nimigean","year":"2008","unstructured":"Nimigean V, Nimigean VR, Maru N, Salavastru DI, Badita D, Tuculina MJ (2008) The maxillary sinus floor in the oral implantology. Rom J Morphol Embryol 49:485\u2013489","journal-title":"Rom J Morphol Embryol"},{"key":"3432_CR24","first-page":"191","volume":"4","author":"P Felice","year":"2011","unstructured":"Felice P, Soardi E, Pellegrino G, Pistilli R, Marchetti C, Gessaroli M, Esposito M (2011) Treatment of the atrophic edentulous maxilla: short implants versus bone augmentation for placing longer implants. Five-month post-loading results of a pilot randomised controlled trial. Eur J Oral Implantol 4:191\u2013202","journal-title":"Eur J Oral Implantol"},{"key":"3432_CR25","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/j.joms.2006.10.047","volume":"65","author":"A Thor","year":"2007","unstructured":"Thor A, Sennerby L, Hirsch JM, Rasmusson L (2007) Bone formation at the maxillary sinus floor following simultaneous elevation of the mucosal lining and implant installation without graft material: an evaluation of 20 patients treated with 44 Astra Tech implants. J Oral Maxillofac Surg 65:64\u201372","journal-title":"J Oral Maxillofac Surg"},{"key":"3432_CR26","doi-asserted-by":"publisher","first-page":"e109","DOI":"10.1111\/clr.12071","volume":"25","author":"B Pommer","year":"2014","unstructured":"Pommer B, Hof M, Fadler A, Gahleitner A, Watzek G, Watzak G (2014) Primary implant stability in the atrophic sinus floor of human cadaver maxillae: impact of residual ridge height, bone density, and implant diameter. Clin Oral Implants Res 25:e109\u2013e113","journal-title":"Clin Oral Implants Res"},{"key":"3432_CR27","doi-asserted-by":"publisher","unstructured":"de Elio Oliveros J, Del Canto DA, Del Canto DM, Jacobo Orea C, Del Canto Pingarron DM, Seco Calvo DJ (2020) Alveolar bone density and width affect primary implant stability. J Oral Implantol. https:\/\/doi.org\/10.1563\/aaid-joi-D-19-00028","DOI":"10.1563\/aaid-joi-D-19-00028"},{"key":"3432_CR28","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1016\/j.jcms.2015.04.008","volume":"43","author":"K Bertl","year":"2015","unstructured":"Bertl K, Heimel P, Rokl-Riegler M, Hirtler L, Ulm C, Zechner W (2015) MicroCT-based evaluation of the trabecular bone quality of different implant anchorage sites for masticatory rehabilitation of the maxilla. J Craniomaxillofac Surg 43:961\u2013968","journal-title":"J Craniomaxillofac Surg"},{"key":"3432_CR29","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1111\/j.1708-8208.2011.00349.x","volume":"15","author":"JT Hsu","year":"2013","unstructured":"Hsu JT, Fuh LJ, Tu MG, Li YF, Chen KT, Huang HL (2013) The effects of cortical bone thickness and trabecular bone strength on noninvasive measures of the implant primary stability using synthetic bone models. Clin Implant Dent Relat Res 15:251\u2013261","journal-title":"Clin Implant Dent Relat Res"},{"key":"3432_CR30","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1111\/clr.12340","volume":"26","author":"K Bertl","year":"2015","unstructured":"Bertl K, Subotic M, Heimel P, Schwarze UY, Tangl S, Ulm C (2015) Morphometric characteristics of cortical and trabecular bone in atrophic edentulous mandibles. Clin Oral Implants Res 26:780\u2013787","journal-title":"Clin Oral Implants Res"},{"key":"3432_CR31","doi-asserted-by":"publisher","first-page":"1861","DOI":"10.1007\/s00784-015-1417-4","volume":"19","author":"ML Valente","year":"2015","unstructured":"Valente ML, de Castro DT, Shimano AC, Lepri CP, dos Reis AC (2015) Analysis of the influence of implant shape on primary stability using the correlation of multiple methods. Clin Oral Investig 19:1861\u20131866","journal-title":"Clin Oral Investig"},{"key":"3432_CR32","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s40729-016-0050-6","volume":"2","author":"Y Shimura","year":"2016","unstructured":"Shimura Y, Sato Y, Kitagawa N, Omori M (2016) Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible. Int J Implant Dent 2:17. https:\/\/doi.org\/10.1186\/s40729-016-0050-6","journal-title":"Int J Implant Dent"},{"key":"3432_CR33","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.adaj.2019.10.022","volume":"151","author":"M Zimmermann","year":"2020","unstructured":"Zimmermann M, Ender A, Mehl A (2020) Local accuracy of actual intraoral scanning systems for single-tooth preparations in vitro. J Am Dent Assoc 151:127\u2013135","journal-title":"J Am Dent Assoc"},{"key":"3432_CR34","doi-asserted-by":"publisher","first-page":"983103","DOI":"10.1155\/2014\/983103","volume":"2014","author":"P Ma","year":"2014","unstructured":"Ma P, Xiong W, Tan B, Geng W, Liu J, Li W, Li D (2014) Influence of thread pitch, helix angle, and compactness on micromotion of immediately loaded implants in three types of bone quality: a three-dimensional finite element analysis. Biomed Res Int 2014:983103\u2013983113. https:\/\/doi.org\/10.1155\/2014\/983103","journal-title":"Biomed Res Int"}],"container-title":["Clinical Oral Investigations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-020-03432-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00784-020-03432-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-020-03432-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,10]],"date-time":"2021-07-10T00:27:39Z","timestamp":1625876859000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00784-020-03432-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,10]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["3432"],"URL":"https:\/\/doi.org\/10.1007\/s00784-020-03432-z","relation":{},"ISSN":["1432-6981","1436-3771"],"issn-type":[{"value":"1432-6981","type":"print"},{"value":"1436-3771","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,10]]},"assertion":[{"value":"15 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No ethical approval was needed for this in vitro investigation. Pig scapulae used in the experiments were taken from slaughterhouse waste.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"For this type of study, formal consent is not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}