{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T12:01:23Z","timestamp":1789041683271,"version":"build-2803163510"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2021,1,28]],"date-time":"2021-01-28T00:00:00Z","timestamp":1611792000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,1,28]],"date-time":"2021-01-28T00:00:00Z","timestamp":1611792000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Oral Invest"],"published-print":{"date-parts":[[2021,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objectives<\/jats:title><jats:p>The aim of this study was, firstly, to analyse the long-time fatigue behaviour of crowns constructed from a novel polyetherketoneketone (PEKK) polymer, using artificial prepared teeth. Secondly, to determine the effect of the material\u2019s stiffness that used as an artificial prepared tooth on the fatigue life of the PEKK crowns in comparison to human prepared teeth.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Veneered crowns with a PEKK framework were constructed on three different prepared teeth: artificial polymethyl methacrylate (PMMA) teeth, artificial CoCr teeth and extracted human teeth. As far as applicable, the loading protocol was based on EN ISO 14801:2007 for fatigue testing of dental implants. After initial static fracture tests on three specimens from each group, the remaining crowns were loaded with different force levels until fracture or until 2\u2009\u00d7\u200910<jats:sup>6<\/jats:sup>loading cycles were reached. The number of loading cycles until failure was recorded. W\u00f6hler curves were created to display the fatigue limits.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Static fracture limits as well as fatigue limits differed for all three core materials. The static fracture tests resulted in fracture limits of 1200 (\u00b1\u2009293) N for the PMMA group, 1330 (\u00b1\u2009219) N for the CoCr group and 899 (\u00b1\u200996) N for the human tooth group. Fatigue limits of 770\u00a0N, 840\u00a0N and 720\u00a0N were determined for the PMMA group, CoCr group and human tooth group, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The determined fatigue limit of above 720\u00a0N (depending on the core material) is sufficiently high and a good performance of this crown material is expected in the clinical loading life. The results showed that using artificial teeth instead of natural teeth for fatigue testing of crowns might result in an overestimation of the fatigue limits of the crown material.<\/jats:p><\/jats:sec><jats:sec><jats:title>Clinical relevance<\/jats:title><jats:p>PEKK-made crowns offer a stable and priceworthy treatment for patients, in particular those that suffer from metal allergy.<\/jats:p><\/jats:sec>","DOI":"10.1007\/s00784-021-03797-9","type":"journal-article","created":{"date-parts":[[2021,1,28]],"date-time":"2021-01-28T00:06:30Z","timestamp":1611792390000},"page":"4895-4905","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Fatigue behaviour of dental crowns made from a novel high-performance polymer PEKK"],"prefix":"10.1007","volume":"25","author":[{"given":"Anne","family":"Katzenbach","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4012-6279","authenticated-orcid":false,"given":"Istabrak","family":"D\u00f6rsam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helmut","family":"Stark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Bourauel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ludger","family":"Keilig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,28]]},"reference":[{"key":"3797_CR1","doi-asserted-by":"publisher","first-page":"33","DOI":"10.2174\/1874210601408010033","volume":"8","author":"EE Daou","year":"2014","unstructured":"Daou EE (2014) The zirconia ceramic: strengths and weaknesses. Open Dent J 8:33\u201342","journal-title":"Open Dent J"},{"key":"3797_CR2","first-page":"307","volume":"21","author":"R N\u00e4p\u00e4nkangas","year":"2008","unstructured":"N\u00e4p\u00e4nkangas R, Raustia A (2008) Twenty-year follow-up of metal-ceramic single crowns: a retrospective study. Int J Prosthodont 21:307\u2013311","journal-title":"Int J Prosthodont"},{"key":"3797_CR3","doi-asserted-by":"publisher","first-page":"1613","DOI":"10.1016\/j.jdent.2014.08.013","volume":"42","author":"MH Nicolaisen","year":"2014","unstructured":"Nicolaisen MH, Bahrami G, Finlay S, Isidor F (2014) Comparison of fatigue resistance and failure modes between metal-ceramic and all-ceramic crowns by cyclic loading in water. J Dent 42:1613\u20131620","journal-title":"J Dent"},{"key":"3797_CR4","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.prosdent.2004.02.004","volume":"91","author":"SF Rosenstiel","year":"2004","unstructured":"Rosenstiel SF, Land MF, Rashid RG (2004) Dentists\u2019 molar restoration choices and longevity: a web-based survey. J Prosthet Dent 91:363\u2013367","journal-title":"J Prosthet Dent"},{"key":"3797_CR5","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1177\/154411130201300108","volume":"13","author":"W Geurtsen","year":"2002","unstructured":"Geurtsen W (2002) Biocompatibility of dental casting alloys. Crit Rev Oral Biol Med 13:71\u201384","journal-title":"Crit Rev Oral Biol Med"},{"key":"3797_CR6","doi-asserted-by":"publisher","first-page":"1772","DOI":"10.1177\/00220345980770100401","volume":"77","author":"G Schmalz","year":"1998","unstructured":"Schmalz G, Langer H, Schweikl H (1998) Cytotoxicity of dental alloy extracts and corresponding metal salt solutions. J Dent Res 77:1772\u20131778","journal-title":"J Dent Res"},{"key":"3797_CR7","doi-asserted-by":"publisher","first-page":"195","DOI":"10.4103\/0972-0707.73379","volume":"13","author":"A Shenoy","year":"2010","unstructured":"Shenoy A, Shenoy N (2010) Dental ceramics: an update. J Conserv Dent 13:195\u2013203","journal-title":"J Conserv Dent"},{"key":"3797_CR8","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1186\/s12903-017-0415-0","volume":"17","author":"T Joda","year":"2017","unstructured":"Joda T, Zarone F, Ferrari M (2017) The complete digital workflow in fixed prosthodontics: a systematic review. BMC Oral Health 17:124","journal-title":"BMC Oral Health"},{"key":"3797_CR9","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1016\/0142-9612(90)90075-2","volume":"11","author":"SA Brown","year":"1990","unstructured":"Brown SA, Hastings RS, Mason JJ, Moet A (1990) Characterization of short-fibre reinforced thermoplastics for fracture fixation devices. Biomaterials 11:541\u2013547","journal-title":"Biomaterials"},{"key":"3797_CR10","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"SM Kurtz","year":"2007","unstructured":"Kurtz SM, Devine JN (2007) PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 28:4845\u20134869","journal-title":"Biomaterials"},{"key":"3797_CR11","first-page":"313","volume-title":"Encyclopedia of polymer science and engineering","author":"R May","year":"1988","unstructured":"May R (1988) Polyetheretherketones. In: Mark HF, Bikales NM, Overberger CG, Menges G, Kroschiwitz JI (eds) Encyclopedia of polymer science and engineering. Wiley, New York, pp 313\u2013320"},{"key":"3797_CR12","first-page":"299","volume-title":"Engineering thermoplastics. Properties and applications","author":"RB Rigby","year":"1985","unstructured":"Rigby RB (1985) Polyetheretherketone. In: Margolis JM (ed) Engineering thermoplastics. Properties and applications. Dekker, New York, pp 299\u2013314"},{"key":"3797_CR13","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1097\/00003086-198810000-00022","volume":"235","author":"HB Skinner","year":"1988","unstructured":"Skinner HB (1988) Composite technology for total hip arthroplasty. Clin Orthop Relat Res 235:224\u2013236","journal-title":"Clin Orthop Relat Res"},{"key":"3797_CR14","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1007\/BF01728981","volume":"6","author":"DF Williams","year":"1987","unstructured":"Williams DF, McNamara A, Turner RM (1987) Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical applications. J Mater Sci Lett 6:188\u2013190","journal-title":"J Mater Sci Lett"},{"key":"3797_CR15","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1563\/aaid-joi-D-16-00072","volume":"42","author":"S Najeeb","year":"2016","unstructured":"Najeeb S, Bds ZK, Bds SZ, Bds MS (2016) Bioactivity and osseointegration of PEEK are inferior to those of titanium: a systematic review. J Oral Implantol 42:512\u2013516","journal-title":"J Oral Implantol"},{"key":"3797_CR16","doi-asserted-by":"crossref","unstructured":"Khurshid Z, Hafeji S, Tekin S, Habib SR, Ullah R, Sefat S, Zafar MS (2020) Titanium, zirconia, and polyetheretherketone (PEEK) as a dental implant material. Dental Implants 5\u201335","DOI":"10.1016\/B978-0-12-819586-4.00002-0"},{"key":"3797_CR17","first-page":"239","volume":"16","author":"M Behr","year":"2003","unstructured":"Behr M, Rosentritt M, Handel G (2003) Fiber-reinforced composite crowns and FPDs: a clinical report. Int J Prosthodont 16:239\u2013243","journal-title":"Int J Prosthodont"},{"key":"3797_CR18","first-page":"493","volume":"34","author":"F Bohlsen","year":"2003","unstructured":"Bohlsen F, Kern M (2003) Clinical outcome of glass-fiber-reinforced crowns and fixed partial dentures: a three-year retrospective study. Quintessence Int 34:493\u2013496","journal-title":"Quintessence Int"},{"key":"3797_CR19","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.jdent.2006.02.001","volume":"34","author":"B Ohlmann","year":"2006","unstructured":"Ohlmann B, Dreyhaupt J, Schmitter M, Gabbert O, Hassel A, Rammelsberg P (2006) Clinical performance of posterior metal-free polymer crowns with and without fiber reinforcement: one-year results of a randomised clinical trial. J Dent 34:757\u2013762","journal-title":"J Dent"},{"key":"3797_CR20","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1007\/s00784-018-2493-z","volume":"23","author":"T Klur","year":"2019","unstructured":"Klur T, Hasan I, Ottersbach K, Stark H, Fichte M, Dirk C, Bourauel C (2019) PEKK-made indirect temporary crowns and bridges: a clinical pilot study. Clin Oral Investig 23:771\u2013777","journal-title":"Clin Oral Investig"},{"key":"3797_CR21","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1515\/bmt-2018-0167","volume":"64","author":"M Kotthaus","year":"2019","unstructured":"Kotthaus M, Hasan I, Keilig L, Gr\u00fcner M, Bourauel C, Stark H (2019) Investigation of the retention forces of secondary telescopic crowns made from Pekkton\u00ae ivory in combination with primary crowns made from four different dental alloys: an in-vitro study. Biomed Tech (Berl) 64:555\u2013562","journal-title":"Biomed Tech (Berl)"},{"key":"3797_CR22","unstructured":"ISO 14801:2007. Dentistry-implants-dynamic fatigue test for endosseous dental implants"},{"key":"3797_CR23","volume-title":"Best practice guide on statistical analysis of fatigue data","author":"CRA Schneider","year":"2003","unstructured":"Schneider CRA, Maddox SJ (2003) Best practice guide on statistical analysis of fatigue data. International Institute of Welding, Cambridge"},{"key":"3797_CR24","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.dental.2013.12.008","volume":"30","author":"G Fuhrmann","year":"2014","unstructured":"Fuhrmann G, Steiner M, Freitag-Wolf S, Kern M (2014) Resin bonding to three types of polyaryletherketones (PAEKs)\u2014durability and influence of surface conditioning. Dent Mater 30:357\u2013363","journal-title":"Dent Mater"},{"key":"3797_CR25","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1016\/j.dental.2010.02.003","volume":"26","author":"PR Schmidlin","year":"2010","unstructured":"Schmidlin PR, Stawarczyk B, Wieland M, Attin T, H\u00e4mmerle CH, Fischer J (2010) Effect of different surface pre-treatments and luting materials on shear bond strength to PEEK. Dent Mater 26:553\u2013559","journal-title":"Dent Mater"},{"key":"3797_CR26","doi-asserted-by":"publisher","first-page":"7213","DOI":"10.1016\/j.apsusc.2012.04.040","volume":"258","author":"L Hallmann","year":"2012","unstructured":"Hallmann L, Mehl A, Sereno N, Hammerle C (2012) The improvement of adhesive properties of PEEK through pre-treatments. Appl Surface Sci 258:7213\u20137218","journal-title":"Appl Surface Sci"},{"key":"3797_CR27","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1016\/j.dental.2012.09.010","volume":"28","author":"M Kern","year":"2012","unstructured":"Kern M, Lehmann F (2012) Influence of surface conditioning on bonding to polyetheretherketon (PEEK). Dent Mater 28:1280\u20131283","journal-title":"Dent Mater"},{"key":"3797_CR28","doi-asserted-by":"publisher","first-page":"350","DOI":"10.4047\/jap.2017.9.5.350","volume":"9","author":"KS Lee","year":"2017","unstructured":"Lee KS, Shin MS, Lee JY, Ryu JJ, Shin SW (2017) Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials. J Adv Prosthodont 9:350\u2013357","journal-title":"J Adv Prosthodont"},{"key":"3797_CR29","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.dental.2017.01.003","volume":"33","author":"V Preis","year":"2017","unstructured":"Preis V, Hahnel S, Behr M, Bein L, Rosentritt M (2017) In-vitro fatigue and fracture testing of CAD\/CAM-materials in implant-supported molar crowns. Dent Mater 33:427\u2013433","journal-title":"Dent Mater"},{"key":"3797_CR30","doi-asserted-by":"publisher","first-page":"607","DOI":"10.4012\/dmj.2013-356","volume":"33","author":"F Komine","year":"2014","unstructured":"Komine F, Taguchi K, Fushiki R, Kamio S, Iwasaki T, Matsumura H (2014) In vitro comparison of fracture load of implant-supported, zirconia-based, porcelain-and composite-layered restorations after artificial aging. Dent Mater J 33:607\u2013613","journal-title":"Dent Mater J"},{"key":"3797_CR31","first-page":"16","volume":"9","author":"FA Daneshvar","year":"2020","unstructured":"Daneshvar FA, Alhavaz A, Ahmadizenouz G, Bijani A (2020) Effect of three veneering techniques on fracture resistance and marginal adaptation of zirconia-based crowns. Caspian J Dent Res 9:16\u201325","journal-title":"Caspian J Dent Res"},{"key":"3797_CR32","doi-asserted-by":"publisher","first-page":"1426","DOI":"10.1016\/j.dental.2009.06.015","volume":"25","author":"M Karl","year":"2009","unstructured":"Karl M, Kelly JR (2009) Influence of loading frequency on implant failure under cyclic fatigue conditions. Dent Mater 25:1426\u20131432","journal-title":"Dent Mater"},{"key":"3797_CR33","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1016\/j.dental.2009.07.003","volume":"25","author":"CK Lee","year":"2009","unstructured":"Lee CK, Karl M, Kelly JR (2009) Evaluation of test protocol variables for dental implant fatigue research. Dent Mater 25:1419\u20131425","journal-title":"Dent Mater"},{"key":"3797_CR34","doi-asserted-by":"crossref","unstructured":"Alsadon O, Wood D, Patrick D, Pollington S (2020) Fatigue behavior and damage modes of high performance poly-ether-ketone-ketone PEKK bilayered crowns. Mech Behav Biomed Mater","DOI":"10.1016\/j.jmbbm.2020.103957"},{"key":"3797_CR35","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1046\/j.1365-2842.2001.00692.x","volume":"28","author":"K Nishigawa","year":"2001","unstructured":"Nishigawa K, Bando E, Nakano M (2001) Quantitative study of bite force during sleep associated bruxism. J Oral Rehabil 28:485\u2013491","journal-title":"J Oral Rehabil"},{"key":"3797_CR36","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1177\/00220345000790071501","volume":"79","author":"FA Fontijn-Tekamp","year":"2000","unstructured":"Fontijn-Tekamp FA, Slagter AP, van der Bilt A, van\u2019t Hof MA, Witter DJ, Kalk W, Jansen JA (2000) Biting and chewing in overdentures, full dentures, and natural dentitions. J Dent Res 79:1519\u20131524","journal-title":"J Dent Res"},{"key":"3797_CR37","first-page":"174013","volume":"2015","author":"A Stocka","year":"2015","unstructured":"Stocka A, Kuc J, Sierpinska T, Golebiewska M, Wieczorek A (2015) The influence of emotional state on the masticatory muscles function in the group of young healthy adults. Biomed Res Int 2015:174013","journal-title":"Biomed Res Int"},{"key":"3797_CR38","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1111\/j.1834-7819.2012.01707.x","volume":"57","author":"R Ogura","year":"2012","unstructured":"Ogura R, Kato H, Okada D, Foxton RM, Ikeda M, Miura H (2012) The relationship between bite force and oral sensation during biting in molars. Aust Dent J 57:292\u2013299","journal-title":"Aust Dent J"},{"key":"3797_CR39","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1016\/0022-3913(81)90455-8","volume":"46","author":"CH Gibbs","year":"1981","unstructured":"Gibbs CH, Mahan PE, Lundeen HC, Brehnan K, Walsh EK, Holbrook WB (1981) Occlusal forces during chewing and swallowing as measured by sound transmission. J Prosthet Dent 46:443\u2013449","journal-title":"J Prosthet Dent"},{"key":"3797_CR40","doi-asserted-by":"publisher","DOI":"10.1111\/jicd.12261","volume":"8","author":"SH Elshiyab","year":"2017","unstructured":"Elshiyab SH, Nawafleh N, George R (2017) Survival and testing parameters of zirconia-based crowns under cyclic loading in an aqueous environment: a systematic review. J Investig Clin Dent 8:e12261","journal-title":"J Investig Clin Dent"},{"key":"3797_CR41","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.dental.2012.10.009","volume":"29","author":"MN Aboushelib","year":"2013","unstructured":"Aboushelib MN (2013) Simulation of cumulative damage associated with long term cyclic loading using a multi-level strain accommodating loading protocol. Dent Mater 29:252\u2013258","journal-title":"Dent Mater"}],"container-title":["Clinical Oral Investigations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-021-03797-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00784-021-03797-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00784-021-03797-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,13]],"date-time":"2022-12-13T17:19:17Z","timestamp":1670951957000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00784-021-03797-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,28]]},"references-count":41,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["3797"],"URL":"https:\/\/doi.org\/10.1007\/s00784-021-03797-9","relation":{},"ISSN":["1432-6981","1436-3771"],"issn-type":[{"value":"1432-6981","type":"print"},{"value":"1436-3771","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,28]]},"assertion":[{"value":"19 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Permission from the patients was taken to donate the extracted teeth for further investigations. Informed consent was not available.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}