{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T04:23:56Z","timestamp":1791951836053,"version":"4.3.4"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T00:00:00Z","timestamp":1609718400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Oral Maxillofac Surg"],"published-print":{"date-parts":[[2021,9]]},"DOI":"10.1007\/s10006-020-00937-5","type":"journal-article","created":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T21:03:44Z","timestamp":1609794224000},"page":"289-301","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Comparison between resorbable plates vs. titanium plates for treatment of zygomatic fractures: a systematic review with meta-analysis"],"prefix":"10.1007","volume":"25","author":[{"given":"Bianca Cristina Lopes","family":"da Silva","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Debora","family":"Souto-Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Glaciele Maria","family":"de Souza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafael Alvim","family":"Magesty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruna","family":"de Cassia \u00c1vila","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Endi Lanza","family":"Galv\u00e3o","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saulo Gabriel Moreira","family":"Falci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,4]]},"reference":[{"issue":"7","key":"937_CR1","first-page":"480","volume":"23","author":"W Ahmed","year":"2013","unstructured":"Ahmed W, Gulzar S, Janjua OS, Luqman U, Shah I (2013) Bioresorbable versus titanium plates for mandibular fractures. J Coll Physicians Surg Pak 23(7):480\u2013483","journal-title":"J Coll Physicians Surg Pak"},{"issue":"7","key":"937_CR2","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1016\/j.jcms.2012.12.004","volume":"41","author":"T Forouzanfar","year":"2013","unstructured":"Forouzanfar T, Salentijn E, Peng G, van den Bergh B (2013) A 10-year analysis of the \u201cAmsterdam\u201d protocol in the treatment of zygomatic complex fractures. Craniomaxillofac Surg. 41(7):616\u2013622. https:\/\/doi.org\/10.1016\/j.jcms.2012.12.004","journal-title":"Craniomaxillofac Surg."},{"issue":"2","key":"937_CR3","doi-asserted-by":"publisher","first-page":"214","DOI":"10.4103\/0975-5950.127654","volume":"4","author":"EG Salentijn","year":"2013","unstructured":"Salentijn EG, Boffano P, Boverhoff J, van den Bergh B, Forouzanfar T (2013) The epidemiological characteristics of zygomatic complex fractures: a comparison between the surgically and non-surgically treated patients. Natl J Maxillofac Surg 4(2):214\u2013218. https:\/\/doi.org\/10.4103\/0975-5950.127654","journal-title":"Natl J Maxillofac Surg"},{"issue":"6","key":"937_CR4","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1097\/PRS.0b013e3182a80819","volume":"2","author":"CL Ellstrom","year":"2013","unstructured":"Ellstrom CL, Evans GR (2013) Evidence-based medicine: zygoma fractures. Plast Reconstr Surg. 2(6):1649\u20131657. https:\/\/doi.org\/10.1097\/PRS.0b013e3182a80819","journal-title":"Plast Reconstr Surg."},{"issue":"3","key":"937_CR5","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.ijom.2005.10.005","volume":"35","author":"D G\u00fclicher","year":"2006","unstructured":"G\u00fclicher D, Krimmel M, Reinert S (2006) The role of intraoperative ultrasonography in zygomatic complex fracture repair. Int J Oral Maxillofac Surg. 35(3):224\u2013230. https:\/\/doi.org\/10.1016\/j.ijom.2005.10.005","journal-title":"Int J Oral Maxillofac Surg."},{"issue":"8","key":"937_CR6","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1016\/j.jcms.2011.11.001","volume":"40","author":"JY Paeng","year":"2012","unstructured":"Paeng JY, Hong J, Kim CS, Kim MJ (2012) Comparative study of skeletal stability between bicortical resorbable and titanium screw fixation after sagittal split ramus osteotomy for mandibular prognathism. J Craniomaxillofac Surg. 40(8):660\u2013664. https:\/\/doi.org\/10.1016\/j.jcms.2011.11.001","journal-title":"J Craniomaxillofac Surg."},{"issue":"3","key":"937_CR7","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.jcms.2019.01.014","volume":"47","author":"SG Chu","year":"2019","unstructured":"Chu SG, Lee JS, Lee JW, Yang JD, Chung HY, Cho BC, Choi KY (2019) Comparisons among four types of absorbable plates used for internal fixation of zygomaticomaxillary complex fractures. J Craniomaxillofac Surg. 47(3):383\u2013388. https:\/\/doi.org\/10.1016\/j.jcms.2019.01.014","journal-title":"J Craniomaxillofac Surg."},{"issue":"2","key":"937_CR8","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1093\/ortho\/27.2.198","volume":"27","author":"IK Mohamed-Hashem","year":"2000","unstructured":"Mohamed-Hashem IK, Mitchell DA (2000) Resorbable implants (plates and screws) in orthognathic surgery. J Orthod. 27(2):198\u2013199. https:\/\/doi.org\/10.1093\/ortho\/27.2.198","journal-title":"J Orthod."},{"issue":"3","key":"937_CR9","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1177\/0022034511434353","volume":"91","author":"G Buijs","year":"2012","unstructured":"Buijs G, van Bakelen N, Jansma J, Visscher J, Hoppenreijs T, Bergsma J, Stegenga B, Bos R (2012) A randomized clinical trial of biodegradable and titanium fixation systems in maxillofacial surgery. J Dent Res 91(3):299\u2013304. https:\/\/doi.org\/10.1177\/0022034511434353","journal-title":"J Dent Res"},{"issue":"5","key":"937_CR10","doi-asserted-by":"publisher","first-page":"e0177152","DOI":"10.1371\/journal.pone.0177152","volume":"12","author":"B Gareb","year":"2017","unstructured":"Gareb B, van Bakelen NB, Buijs GJ, Jansma J, de Visscher JGAM, Hoppenreijs TJM, Bergsma JE, van Minnen B, Stegenga B, Bos RRM (2017) Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: a multicenter randomized controlled trial. PLoS One 12(5):e0177152. Published 2017 May 11. https:\/\/doi.org\/10.1371\/journal.pone.0177152","journal-title":"PLoS One"},{"issue":"12","key":"937_CR11","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1177\/0022034513508953","volume":"92","author":"NB van Bakelen","year":"2013","unstructured":"van Bakelen NB, Buijs GJ, Jansma J, de Visscher JG, Hoppenreijs TJ, Bergsma JE, Stegenga B, Bos RR (2013) Comparison of biodegradable and titanium fixation systems in maxillofacial surgery: a two-year multi center randomized controlled trial. J Dent Res. 92(12):1100\u20131105. https:\/\/doi.org\/10.1177\/0022034513508953","journal-title":"J Dent Res."},{"issue":"6","key":"937_CR12","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/s0901-5027(05)80261-9","volume":"20","author":"L Rix","year":"1991","unstructured":"Rix L, Stevenson AR, Punnia-Moorthy A (1991) An analysis of 80 cases of mandibular fractures treated with miniplate osteosynthesis. Int J Oral Maxillofac Surg 20(6):337\u2013341. https:\/\/doi.org\/10.1016\/s0901-5027(05)80261-9","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"2","key":"937_CR13","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/s0266-4356(96)90372-1","volume":"34","author":"TF Renton","year":"1996","unstructured":"Renton TF, Wiesenfeld D (1996) Mandibular fracture osteosynthesis: a comparison of three techniques. Br J Oral Maxillofac Surg. 34(2):166\u2013173. https:\/\/doi.org\/10.1016\/s0266-4356(96)90372-1","journal-title":"Br J Oral Maxillofac Surg."},{"issue":"1","key":"937_CR14","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1001\/jamafacial.2013.1404","volume":"16","author":"MA Carron","year":"2014","unstructured":"Carron MA, Zuliani G, Pereira L, Abuhamdan M, Thibault A, Dau N, Bir C (2014) Stability of midface fracture repair using absorbable plate and screw system pilot holes drilled and pin placement at angles other than 90\u00b0. JAMA Facial Plast Surg 16(1):42\u201348. https:\/\/doi.org\/10.1001\/jamafacial.2013.1404","journal-title":"JAMA Facial Plast Surg"},{"issue":"1","key":"937_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.7181\/acfs.2016.17.1.1","volume":"17","author":"SH Choi","year":"2016","unstructured":"Choi SH, Lee JH (2016) Absorbable plate-related infection after facial bone fracture reduction. Arch Craniofac Surg. 17(1):1\u20134. https:\/\/doi.org\/10.7181\/acfs.2016.17.1.1","journal-title":"Arch Craniofac Surg."},{"issue":"2","key":"937_CR16","doi-asserted-by":"publisher","first-page":"181","DOI":"10.4103\/0975-5950.127648","volume":"4","author":"N Tripathi","year":"2013","unstructured":"Tripathi N, Goyal M, Mishra B, Dhasmana S (2013) Zygomatic complex fracture: a comparative evaluation of stability using titanium and bio-resorbable plates as one point fixation. Natl J Maxillofac Surg. 4(2):181\u2013187. https:\/\/doi.org\/10.4103\/0975-5950.127648","journal-title":"Natl J Maxillofac Surg."},{"key":"937_CR17","doi-asserted-by":"publisher","first-page":"CD007158","DOI":"10.1002\/14651858.CD007158.pub2","volume":"1","author":"M Dorri","year":"2009","unstructured":"Dorri M, Nasser M, Oliver R (2009) Resorbable versus titanium plates for facial fractures. Cochrane Database Syst Rev 1:CD007158. Published 2009 Jan 21. https:\/\/doi.org\/10.1002\/14651858.CD007158.pub2","journal-title":"Cochrane Database Syst Rev"},{"issue":"4","key":"937_CR18","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.tripleo.2005.07.026","volume":"101","author":"G Wittwer","year":"2006","unstructured":"Wittwer G, Adeyemo WL, Yerit K, Voracek M, Turhani D, Watzinger F, Enislidis G (2006) Complications after zygoma fracture fixation: is there a difference between biodegradable materials and how do they compare with titanium osteosynthesis? Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 101(4):419\u2013425. https:\/\/doi.org\/10.1016\/j.tripleo.2005.07.026","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod."},{"issue":"7","key":"937_CR19","doi-asserted-by":"publisher","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","volume":"6","author":"D Moher","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG (2009) PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 6(7):e1000097. https:\/\/doi.org\/10.1371\/journal.pmed.1000097","journal-title":"PLoS Med."},{"key":"937_CR20","doi-asserted-by":"crossref","unstructured":"Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors) (2019) Cochrane Handbook for Systematic Reviews of Interventions version 6.0 (updated July 2019).Cochrane. Available from www.training.cochrane.org\/handbook.","DOI":"10.1002\/9781119536604"},{"key":"937_CR21","doi-asserted-by":"publisher","unstructured":"[Dataset] Souto-Souza D (2000) Comparison between resorbable plates vs. titanium plates for treatment of zygomatic fractures: a systematic review with meta-analysis. Mendeley Data. v1. https:\/\/doi.org\/10.17632\/vpn3gwv52k.1","DOI":"10.17632\/vpn3gwv52k.1"},{"issue":"Suppl 1","key":"937_CR22","doi-asserted-by":"publisher","first-page":"S85","DOI":"10.1097\/SAP.0000000000000700","volume":"76","author":"SM Mahmoud","year":"2016","unstructured":"Mahmoud SM, Liao HT, Chen CT (2016) Aesthetic and functional outcome of zygomatic fractures fixation comparison with resorbable versus titanium plates. Ann Plast Surg 76(Suppl 1):S85\u2013S90. https:\/\/doi.org\/10.1097\/SAP.0000000000000700","journal-title":"Ann Plast Surg"},{"issue":"4","key":"937_CR23","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1016\/S0377-1237(07)80008-6","volume":"63","author":"S Menon","year":"2007","unstructured":"Menon S, Chowdhury SKR (2007) Evaluation of bioresorbable vis-a-vis titanium plates and screws for craniofacial fractures and osteotomies. Med J Armed Forces India 63(4):331\u2013333. https:\/\/doi.org\/10.1016\/S0377-1237(07)80008-6","journal-title":"Med J Armed Forces India"},{"issue":"2","key":"937_CR24","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1007\/s12663-011-0177-1","volume":"11","author":"S Menon","year":"2012","unstructured":"Menon S, Choudhury CS (2012) Resorbable implants in maxillofacial surgery: a reality check. J Maxillofac Oral Surg. 11(2):132\u2013137. https:\/\/doi.org\/10.1007\/s12663-011-0177-1","journal-title":"J Maxillofac Oral Surg."},{"issue":"8","key":"937_CR25","doi-asserted-by":"publisher","first-page":"2124","DOI":"10.1097\/SCS.0000000000003147","volume":"27","author":"S Sukegawa","year":"2016","unstructured":"Sukegawa S, Kanno T, Nagano D, Shibata A, Sukegawa-Takahashi Y, Furuki Y (2016) The clinical feasibility of newly developed thin flat-type bioresorbable osteosynthesis devices for the internal fixation of zygomatic fractures: is there a difference in healing between bioresorbable materials and titanium osteosynthesis? J Craniofac Surg 27(8):2124\u20132129. https:\/\/doi.org\/10.1097\/SCS.0000000000003147","journal-title":"J Craniofac Surg"},{"issue":"7","key":"937_CR26","doi-asserted-by":"publisher","first-page":"e0130330","DOI":"10.1371\/journal.pone.0130330","volume":"10","author":"NB van Bakelen","year":"2015","unstructured":"van Bakelen NB, Vermeulen KM, Buijs GJ, Jansma J, de Visscher JG, Hoppenreijs TJ, Bergsma JE, Stegenga B, Bos RR (2015) Cost-effectiveness of a biodegradable compared to a titanium fixation system in maxillofacial surgery: a multicenter randomized controlled trial. PLoS One 10(7):e0130330. https:\/\/doi.org\/10.1371\/journal.pone.0130330","journal-title":"PLoS One"},{"key":"937_CR27","unstructured":"Mazzonetto RA (2000) Utiliza\u00e7\u00e3o de sistema de fixa\u00e7\u00e3o r\u00edgida reabsorv\u00edvel em cirurgia ortogn\u00e1tica. \u00d3rg\u00e3o Oficial do Col\u00e9gio Brasileiro de Cirurgia e Traumatologia Buco-MaxiloFacial 21"},{"issue":"1","key":"937_CR28","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1067\/moe.2002.122160","volume":"94","author":"H Peltoniemi","year":"2002","unstructured":"Peltoniemi H, Ashammakhi N, Kontio R, Waris T, Salo A, Lindqvist C, Gr\u00e4tz K, Suuronen R (2002) The use of bioabsorbable osteofixation devices in craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 94(1):5\u201314. https:\/\/doi.org\/10.1067\/moe.2002.122160","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"3","key":"937_CR29","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1097\/00001665-200105000-00009","volume":"12","author":"L Hollier","year":"2001","unstructured":"Hollier L, Rogers N, Berzin E, Stal S (2001) Resorbable mesh in the treatment of orbital floor fractures. J Craniofac Surg 12(3):242\u2013246. https:\/\/doi.org\/10.1097\/00001665-200105000-00009","journal-title":"J Craniofac Surg"},{"issue":"Suppl 1 Pt 1","key":"937_CR30","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1515\/bmte.2002.47.s1a.496","volume":"47","author":"J Hoffmann","year":"2002","unstructured":"Hoffmann J, Troitzsch D, Gulicher D, Adam C, Reinert S (2002) Significance of biodegradable implants in case of midfacial fractures. Biomed Tech (Berl) 47(Suppl 1 Pt 1):496\u2013499. https:\/\/doi.org\/10.1515\/bmte.2002.47.s1a.496","journal-title":"Biomed Tech (Berl)"},{"issue":"1","key":"937_CR31","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.ijom.2004.03.020","volume":"34","author":"G Enislidis","year":"2005","unstructured":"Enislidis G, Lagogiannis G, Wittwer G, Glaser C, Ewers R (2005) Fixation of zygomatic fractures with a biodegradable copolymer osteosynthesis system: short- and long-term results. Int J Oral Maxillofac Surg 34(1):19\u201326. https:\/\/doi.org\/10.1016\/j.ijom.2004.03.020","journal-title":"Int J Oral Maxillofac Surg"},{"key":"937_CR32","first-page":"31","volume":"2","author":"J Filho","year":"2002","unstructured":"Filho J, Camargo IB, Ferreira DM, Barros TQ (2002) Fixa\u00e7\u00e3o interna r\u00edgida reabsorv\u00edvel. Rev Cir Traumat Buco - Maxilo-Facial 2:31\u201340","journal-title":"Rev Cir Traumat Buco - Maxilo-Facial"},{"issue":"8","key":"937_CR33","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1016\/j.joms.2009.09.005","volume":"68","author":"K Bhatt","year":"2010","unstructured":"Bhatt K, Roychoudhury A, Bhutia O, Trikha A, Seith A, Pandey R (2010) Equivalence randomized controlled trial of bioresorbable versus titanium miniplates in treatment of mandibular fracture: a pilot study. J Oral Maxillofac Surg 68(8):1842\u20131848. https:\/\/doi.org\/10.1016\/j.joms.2009.09.005","journal-title":"J Oral Maxillofac Surg"},{"issue":"4","key":"937_CR34","first-page":"32","volume":"4","author":"RJ Triana","year":"1998","unstructured":"Triana RJ, Shockley WW (1998) Pediatric zygomaticoorbital complex fractures: the use of resorbable plating systems - a case report. J Craniomaxillofac Trauma. 4(4):32\u201336","journal-title":"J Craniomaxillofac Trauma."},{"issue":"7","key":"937_CR35","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.jcms.2010.02.008","volume":"38","author":"I Iatrou","year":"2010","unstructured":"Iatrou I, Theologie-lygidakis N, Tzerbos F (2010) Surgical protocols and outcome for the treatment of maxillofacial fractures in children: 9 years\u2019 experience. J Craniomaxillofac Surg. 38(7):511\u2013516. https:\/\/doi.org\/10.1016\/j.jcms.2010.02.008","journal-title":"J Craniomaxillofac Surg."},{"issue":"4","key":"937_CR36","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1097\/SCS.0b013e31824e7106","volume":"23","author":"S Maqusi","year":"2012","unstructured":"Maqusi S, Morris DE, Patel PK, Dolezal RF, Cohen MN (2012) Complications of pediatric facial fractures. J Craniofac Surg 23(4):1023\u20131027. https:\/\/doi.org\/10.1097\/SCS.0b013e31824e7106","journal-title":"J Craniofac Surg"},{"issue":"2","key":"937_CR37","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1001\/archoto.2010.241","volume":"137","author":"CH Park","year":"2011","unstructured":"Park CH, Kim HS, Lee JH, Hong SM (2011) Resorbable skeletal fixation systems for treating maxillofacial bone fractures. Arch Otolaryngol Head Neck Surg. 137(2):125\u2013129. https:\/\/doi.org\/10.1001\/archoto.2010.241","journal-title":"Arch Otolaryngol Head Neck Surg."},{"issue":"1","key":"937_CR38","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.jcms.2014.10.003","volume":"43","author":"H Llandro","year":"2015","unstructured":"Llandro H, Langford R (2015) Reasons for plate removal after treatment of orbitozygomatic complex fractures. J Craniomaxillofac Surg. 43(1):17\u201320. https:\/\/doi.org\/10.1016\/j.jcms.2014.10.003","journal-title":"J Craniomaxillofac Surg."},{"issue":"5","key":"937_CR39","doi-asserted-by":"publisher","first-page":"e32","DOI":"10.1016\/j.tripleo.2008.01.006","volume":"105","author":"A Bakathir","year":"2008","unstructured":"Bakathir A, Margasahayam MV, Mohammed I (2008) Removal of bone plates in patients with maxillofacial trauma: a retrospective study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 105(5):e32\u2013e37. https:\/\/doi.org\/10.1016\/j.tripleo.2008.01.006","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod."},{"key":"937_CR40","first-page":"35","volume":"5","author":"RL Ciuccio","year":"2010","unstructured":"Ciuccio RL, Luiz NE, Jacomini Filho A, Soares MAD (2010) Compara\u00e7\u00e3o entre resultados de testes experimentais com a simula\u00e7\u00e3o num\u00e9rica pelo m\u00e9todo de elementos finitos em placas de cirurgia buco maxilo facial. Innov. Implant. J Biomater. Esthet 5:35\u201338","journal-title":"J Biomater. Esthet"},{"issue":"3","key":"937_CR41","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1097\/01.scs.0000157308.39420.74","volume":"16","author":"Y Yonehara","year":"2005","unstructured":"Yonehara Y, Hirabayashi S, Tachi M, Ishii H (2005) Treatment of zygomatic fractures without inferior orbital rim fixation. J Craniofac Surg 16(3):481\u2013485. https:\/\/doi.org\/10.1097\/01.scs.0000157308.39420.74","journal-title":"J Craniofac Surg"},{"issue":"1","key":"937_CR42","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/0142-9612(95)91092-d","volume":"16","author":"E Bergsma","year":"1995","unstructured":"Bergsma E, de Brujin W, Rozema F, Bos R, Boering G (1995) Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials 16(1):25\u201331. https:\/\/doi.org\/10.1016\/0142-9612(95)91092-d","journal-title":"Biomaterials"},{"key":"937_CR43","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1590\/S0080-623420140000100022","volume":"48","author":"BV Cavichio","year":"2014","unstructured":"Cavichio BV, Pompeo DA, Oller GA, Rossi LA (2014) Tempo de cessa\u00e7\u00e3o do tabagismo para a preven\u00e7\u00e3o de complica\u00e7\u00f5es na cicatriza\u00e7\u00e3o de feridas cir\u00fargicas. Rev. esc. enferm USP 48:170\u2013176","journal-title":"Rev. esc. enferm USP"},{"key":"937_CR44","doi-asserted-by":"publisher","first-page":"685","DOI":"10.18203\/2349-2902.isj20170214","volume":"4","author":"M Noor","year":"2017","unstructured":"Noor M, Ishaq Y, Anwar MA (2017) Frequency of infra-orbital nerve injury after a zygomaticomaxillary complex fracture and its functional recovery after open reduction and internal fixation. Inter. Surg. Journal 4:685\u2013689. https:\/\/doi.org\/10.18203\/2349-2902.isj20170214","journal-title":"Inter. Surg. Journal"}],"container-title":["Oral and Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10006-020-00937-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10006-020-00937-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10006-020-00937-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,9]],"date-time":"2021-08-09T04:07:05Z","timestamp":1628482025000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10006-020-00937-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,4]]},"references-count":44,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,9]]}},"alternative-id":["937"],"URL":"https:\/\/doi.org\/10.1007\/s10006-020-00937-5","relation":{},"ISSN":["1865-1550","1865-1569"],"issn-type":[{"value":"1865-1550","type":"print"},{"value":"1865-1569","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,4]]},"assertion":[{"value":"28 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}