{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T06:57:21Z","timestamp":1791961041860,"version":"4.3.4"},"reference-count":19,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[1998,5,1]],"date-time":"1998-05-01T00:00:00Z","timestamp":893980800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[1998,5,1]],"date-time":"1998-05-01T00:00:00Z","timestamp":893980800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2007,1,8]],"date-time":"2007-01-08T00:00:00Z","timestamp":1168214400000},"content-version":"vor","delay-in-days":3174,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["annalsofvascularsurgery.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Annals of Vascular Surgery"],"published-print":{"date-parts":[[1998,5]]},"DOI":"10.1007\/s100169900149","type":"journal-article","created":{"date-parts":[[2002,7,25]],"date-time":"2002-07-25T03:04:07Z","timestamp":1027566247000},"page":"255-259","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"title":["The Natural History of \u201cFailing\u201d Arterial Bypass Grafts in a Duplex Surveillance Protocol"],"prefix":"10.1016","volume":"12","author":[{"given":"Matthew J.","family":"Dougherty","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith D.","family":"Calligaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominic A.","family":"DeLaurentis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1007\/s100169900149_bib1","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1001\/archsurg.1986.01400070024004","article-title":"Recognition and management of impending vein graft failure","volume":"121","author":"Cohen","year":"1986","journal-title":"Arch Surg"},{"key":"10.1007\/s100169900149_bib2","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1097\/00000658-198910000-00009","article-title":"Serial noninvasive studies do not herald postoperative failure of femoropopliteal or femorotibial bypass grafts","volume":"210","author":"Barnes","year":"1989","journal-title":"Ann Surg"},{"key":"10.1007\/s100169900149_bib3","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/S0741-5214(95)70241-5","article-title":"Femoropopliteal-crural graft patency is improved by an intensive surveillance program: A prospective randomized study","volume":"21","author":"Lundell","year":"1995","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib4","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/0741-5214(89)90048-7","article-title":"Monitoring functional patency of in situ saphenous vein bypasses: The impact of a surveillance protocol and elective revision","volume":"9","author":"Bandyk","year":"1989","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib5","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/0741-5214(90)90039-D","article-title":"The importance of routine surveillance of distal bypass grafts with duplex scanning: A study of 379 reversed vein grafts","volume":"12","author":"Mills","year":"1990","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib6","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/00000658-199505000-00008","article-title":"Intensive surveillance of femoropopliteal-tibial autogenous vein bypasses improves long-term graft patency and limb salvage","volume":"221","author":"Bergamini","year":"1995","journal-title":"Ann Surg"},{"key":"10.1007\/s100169900149_bib7","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1067\/mva.1991.32966","article-title":"Color-flow duplex criteria for grading stenosis in infrainguinal vein grafts","volume":"14","author":"Buth","year":"1991","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib8","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/0741-5214(88)90071-7","article-title":"Detection and grading of femorodistal vein graft stenoses: Duplex velocity measurements compared with angiography","volume":"8","author":"Grigg","year":"1988","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib9","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/0741-5214(93)90009-B","article-title":"Does correction of stenoses identified with color duplex scanning improve infrainguinal graft patency?","volume":"17","author":"Mattos","year":"1993","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib10","first-page":"799","article-title":"A low flow velocity predicts failure of femoropopliteal and femorotibial bypass grafts","volume":"98","author":"Bandyk","year":"1985","journal-title":"Surgery"},{"key":"10.1007\/s100169900149_bib11","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0002-9610(97)90070-2","article-title":"Is color duplex surveillance of infrainguinal polytetrafluoroethylene grafts worthwhile?","volume":"174","author":"Hoballah","year":"1997","journal-title":"Am J Surg"},{"key":"10.1007\/s100169900149_bib12","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/S0039-6060(96)80063-8","article-title":"Duplex ultrasonography to diagnose failing arterial prosthetic grafts","volume":"120","author":"Calligaro","year":"1996","journal-title":"Surgery"},{"key":"10.1007\/s100169900149_bib13","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/0741-5214(93)90008-A","article-title":"Impact of color-flow duplex surveillance program on infrainguinal vein graft patency: A five-year experience","volume":"17","author":"Idu","year":"1993","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib14","first-page":"211","article-title":"Duplex criteria for predicting progression of vein graft lesions: Which stenoses can be followed?","volume":"19","author":"Gahtan","year":"1995","journal-title":"J Vasc Tech"},{"key":"10.1007\/s100169900149_bib15","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1016\/S0741-5214(97)70125-3","article-title":"Hemodynamic impact of vein graft stenoses and their prediction in the vascular laboratory","volume":"25","author":"Belkin","year":"1997","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib16","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/0002-9610(89)90356-5","article-title":"Color-flow duplex screening of infrainguinal grafts combining low and high velocity criteria","volume":"158","author":"Sladen","year":"1989","journal-title":"Am J Surg"},{"key":"10.1007\/s100169900149_bib17","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1016\/0741-5214(93)90553-X","article-title":"Is surveillance to detect failing polytetrafluoroethylene grafts worthwhile? Twelve-year experience with ninety-one grafts","volume":"18","author":"Sanchez","year":"1993","journal-title":"J Vasc Surg"},{"key":"10.1007\/s100169900149_bib18","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1007\/BF02018828","article-title":"Long-term surveillance by duplex scanning of non-revised infragenicular graft stenosis","volume":"9","author":"Ho","year":"1995","journal-title":"Ann Vasc Surg"},{"key":"10.1007\/s100169900149_bib19","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/0741-5214(91)90212-D","article-title":"Durability of vein graft revision: The outcome of secondary procedures","volume":"13","author":"Bandyk","year":"1991","journal-title":"J Vasc Surg"}],"container-title":["Annals of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S089050960661666X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S089050960661666X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T12:50:20Z","timestamp":1760187020000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S089050960661666X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998,5]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1998,5]]}},"alternative-id":["S089050960661666X"],"URL":"https:\/\/doi.org\/10.1007\/s100169900149","relation":{},"ISSN":["0890-5096"],"issn-type":[{"value":"0890-5096","type":"print"}],"subject":[],"published":{"date-parts":[[1998,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The Natural History of \u201cFailing\u201d Arterial Bypass Grafts in a Duplex Surveillance Protocol","name":"articletitle","label":"Article Title"},{"value":"Annals of Vascular Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1007\/s100169900149","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 1998 Annals of Vascular Surgery, Inc. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}