{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T02:17:00Z","timestamp":1788833820117,"version":"build-2803163510"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T00:00:00Z","timestamp":1563494400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T00:00:00Z","timestamp":1563494400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Hernia"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s10029-019-02008-5","type":"journal-article","created":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T07:02:55Z","timestamp":1563519775000},"page":"1123-1132","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Atraumatic laparoscopic intraperitoneal mesh fixation using a new laparoscopic device: an animal experimental study"],"prefix":"10.1007","volume":"23","author":[{"given":"R. N.","family":"Villalobos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. C.","family":"Mias","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Gas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"Maestre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Nogu\u00e9s","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F.","family":"Vilardell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. J.","family":"Olsina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,7,19]]},"reference":[{"key":"2008_CR1","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/s10029-008-0414-9","volume":"13","author":"J Rosenberg","year":"2009","unstructured":"Rosenberg J (2009) Pain, quality of life and recovery after laparoscopic ventral hernia repair. Hernia 13:13\u201321. \nhttps:\/\/doi.org\/10.1007\/s10029-008-0414-9","journal-title":"Hernia"},{"issue":"12","key":"2008_CR2","doi-asserted-by":"publisher","first-page":"384","DOI":"10.4240\/wjgs.v7.i12.384","volume":"7","author":"O Langbach","year":"2015","unstructured":"Langbach O (2015) Long term recurrence, pain and patient satisfaction after ventral hernia mesh repair. World J Gastrointest Surg 7(12):384. \nhttps:\/\/doi.org\/10.4240\/wjgs.v7.i12.384","journal-title":"World J Gastrointest Surg"},{"key":"2008_CR3","doi-asserted-by":"publisher","first-page":"1296","DOI":"10.1007\/s00464-009-0763-1","volume":"24","author":"E Wassenaar","year":"2010","unstructured":"Wassenaar E, Schoenmaeckers E (2010) Mesh-fixation method and pain and quality of life after laparoscopic ventral or incisional hernia repair: a randomized trial of three fixation techniques. Surg Endosc 24:1296\u20131302. \nhttps:\/\/doi.org\/10.1007\/s00464-009-0763-1","journal-title":"Surg Endosc"},{"key":"2008_CR4","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/s00423-013-1126-x","volume":"399","author":"E Reynvoet","year":"2014","unstructured":"Reynvoet E, Deschepper E, Rogiers X, Troisi R, Berrevoet F (2014) Laparoscopic ventral hernia repair: is there an optimal mesh fixation technique? A systematic review. Langenbeck's Arch Surg 399:55\u201363. \nhttps:\/\/doi.org\/10.1007\/s00423-013-1126-x","journal-title":"Langenbeck's Arch Surg"},{"issue":"5","key":"2008_CR5","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10029-013-1084-9","volume":"17","author":"F Muysoms","year":"2013","unstructured":"Muysoms F, Vander Mijnsbrugge G, Pletinckx P et al (2013) Randomized clinical trial of mesh fixation with \u201cdouble crown\u201d versus \u201csutures and tackers\u201d in laparoscopic ventral hernia repair. Hernia 17(5):603\u2013612. \nhttps:\/\/doi.org\/10.1007\/s10029-013-1084-9","journal-title":"Hernia"},{"key":"2008_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2015.06.008","author":"SA Antoniou","year":"2015","unstructured":"Antoniou SA, Ph D, Ko G et al (2015) Meta-analysis of randomized trials comparing nonpenetrating vs mechanical mesh fixation in laparoscopic inguinal hernia repair. Am J Surg. \nhttps:\/\/doi.org\/10.1016\/j.amjsurg.2015.06.008","journal-title":"Am J Surg"},{"key":"2008_CR7","doi-asserted-by":"publisher","first-page":"2558","DOI":"10.1007\/s00268-014-2547-6","volume":"38","author":"NS Shah","year":"2014","unstructured":"Shah NS, Fullwood C (2014) Mesh fixation at laparoscopic inguinal hernia repair: a meta-analysis comparing tissue glue and tack fixation. World J Surg 38:2558\u20132570. \nhttps:\/\/doi.org\/10.1007\/s00268-014-2547-6","journal-title":"World J Surg"},{"issue":"7","key":"2008_CR8","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1007\/s00464-012-2156-0","volume":"26","author":"RH Fortelny","year":"2012","unstructured":"Fortelny RH, Petter-Puchner AH, Glaser KS, Redl H (2012) Use of fibrin sealant (Tisseel\/Tissucol) in hernia repair: a systematic review. Surg Endosc Other Interv Tech 26(7):1803\u20131812. \nhttps:\/\/doi.org\/10.1007\/s00464-012-2156-0","journal-title":"Surg Endosc Other Interv Tech"},{"key":"2008_CR9","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.jss.2009.11.710","volume":"162","author":"R Ladurner","year":"2011","unstructured":"Ladurner R, Drosse I, Bu D et al (2011) Cyanoacrylate glue for intra-abdominal mesh fixation of polypropylene-polyvinylidene fluoride meshes in a rabbit model. J Surg Res 162:157\u2013162. \nhttps:\/\/doi.org\/10.1016\/j.jss.2009.11.710","journal-title":"J Surg Res"},{"key":"2008_CR10","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.jss.2010.05.003","volume":"6","author":"P Losi","year":"2010","unstructured":"Losi P, Burchielli S, Vet MD et al (2010) Cyanoacrylate surgical glue as an alternative to suture threads for mesh fixation in hernia repair. J Surg Res 6:6\u201311. \nhttps:\/\/doi.org\/10.1016\/j.jss.2010.05.003","journal-title":"J Surg Res"},{"key":"2008_CR11","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s10029-015-1347-8","volume":"19","author":"E Reynvoet","year":"2015","unstructured":"Reynvoet E, Van Cleven S, Van Overbeke I et al (2015) The use of cyanoacrylate sealant as simple mesh fixation in laparoscopic ventral hernia repair: a large animal evaluation. Hernia 19:661\u2013670. \nhttps:\/\/doi.org\/10.1007\/s10029-015-1347-8","journal-title":"Hernia"},{"issue":"4","key":"2008_CR12","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1007\/s10029-016-1482-x","volume":"21","author":"Y-M Shen","year":"2017","unstructured":"Shen Y-M, Liu Y-T, Chen J, Sun L (2017) Efficacy and safety of NBCA (n-butyl-2-cyanoacrylate) medical adhesive for patch fixation in totally extraperitoneal prosthesis (TEP): a prospective, randomized, controlled trial. Eur Rev Med Pharmacol Sci 21(4):680\u2013686. \nhttps:\/\/doi.org\/10.1007\/s10029-016-1482-x","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"2008_CR13","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1007\/s10029-006-0080-8","volume":"10","author":"BR Schwab","year":"2006","unstructured":"Schwab BR (2006) Less chronic pain following mesh fixation using a fibrin sealant in TEP inguinal hernia repair. Hernia 10:272\u2013277. \nhttps:\/\/doi.org\/10.1007\/s10029-006-0080-8","journal-title":"Hernia"},{"issue":"6","key":"2008_CR14","first-page":"321","volume":"69","author":"A Burza","year":"2014","unstructured":"Burza A, Avantifiori R, Curinga R, Santini E, Delle Site PSF (2014) Comparison between two different mesh fixation methods in laparoscopic inguinal hernia repair: tacker vs synthetic cyanoacrylate glue. Minerva Chir 69(6):321\u2013329","journal-title":"Minerva Chir"},{"key":"2008_CR15","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1007\/s10029-008-0375-z","volume":"12","author":"J Rosenberg","year":"2008","unstructured":"Rosenberg J (2008) Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel\u00ae) vs. titanium tacks: a randomised controlled experimental study in pigs. Hernia 12:483\u2013491. \nhttps:\/\/doi.org\/10.1007\/s10029-008-0375-z","journal-title":"Hernia"},{"key":"2008_CR16","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1002\/bjs.7646","volume":"98","author":"JR Eriksen","year":"2009","unstructured":"Eriksen JR, Bisgaard T, Assaadzadeh S, Jorgensen LN, Rosenberg J (2009) Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair. Br J Surg 98:1537\u20131545. \nhttps:\/\/doi.org\/10.1002\/bjs.7646","journal-title":"Br J Surg"},{"key":"2008_CR17","doi-asserted-by":"publisher","first-page":"240","DOI":"10.4293\/108680810X12785289144359","volume":"14","author":"O Stefano","year":"2010","unstructured":"Stefano O, Giovanni C, Luca S, Claudio P, Giuseppe V, Enrico C (2010) Laparoscopic incisional hernia repair with fibrin glue in select patients. JSLS 14:240\u2013245. \nhttps:\/\/doi.org\/10.4293\/108680810X12785289144359","journal-title":"JSLS"},{"key":"2008_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-017-5869-8","author":"G Pascual","year":"2017","unstructured":"Pascual G, Rodr\u00edguez M, P\u00e9rez-k\u00f6hler B et al (2017) Host tissue response by the expression of collagen to cyanoacrylate adhesives used in implant fixation for abdominal hernia repair. J Mater Sci Mater Med. \nhttps:\/\/doi.org\/10.1007\/s10856-017-5869-8","journal-title":"J Mater Sci Mater Med"},{"issue":"3","key":"2008_CR19","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/s10029-009-0622-y","volume":"14","author":"NB Zinther","year":"2010","unstructured":"Zinther NB, Wara P, Friis-Andersen H (2010) Intraperitoneal onlay mesh: an experimental study of adhesion formation in a sheep model. Hernia 14(3):283\u2013289. \nhttps:\/\/doi.org\/10.1007\/s10029-009-0622-y","journal-title":"Hernia"},{"issue":"6","key":"2008_CR20","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s12262-010-0168-3","volume":"72","author":"B Gungor","year":"2010","unstructured":"Gungor B, Malazgirt Z, Topg\u00fcl K, G\u00f6k A, Bilgin M, Y\u00fcr\u00fcker S (2010) Comparative evaluation of adhesions to intraperitoneally placed fixation materials: a laparoscopic study in rats. Indian J Surg 72(6):475\u2013480. \nhttps:\/\/doi.org\/10.1007\/s12262-010-0168-3","journal-title":"Indian J Surg"},{"key":"2008_CR21","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1007\/s00464-010-1244-2","volume":"25","author":"T Clarke","year":"2011","unstructured":"Clarke T, Katkhouda N, Mason RJ (2011) Fibrin glue for intraperitoneal laparoscopic mesh fixation: a comparative study in a swine model. Surg Endosc 25:737\u2013748. \nhttps:\/\/doi.org\/10.1007\/s00464-010-1244-2","journal-title":"Surg Endosc"},{"key":"2008_CR22","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1007\/s10029-013-1101-z","volume":"17","author":"JR Eriksen","year":"2013","unstructured":"Eriksen JR, Bisgaard T, Assaadzadeh S, Jorgensen LN, Rosenberg J (2013) Fibrin sealant for mesh fixation in laparoscopic umbilical hernia repair: 1-year results of a randomized controlled double-blinded study. Hernia 17:511\u2013514. \nhttps:\/\/doi.org\/10.1007\/s10029-013-1101-z","journal-title":"Hernia"},{"issue":"3","key":"2008_CR23","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/J.JAMCOLLSURG.2010.12.006","volume":"212","author":"ED Jenkins","year":"2011","unstructured":"Jenkins ED, Melman L, Deeken CR, Greco SC, Frisella MM, Matthews BD (2011) Biomechanical and histologic evaluation of fenestrated and nonfenestrated biologic mesh in a porcine model of ventral hernia repair. J Am Coll Surg 212(3):327\u2013339. \nhttps:\/\/doi.org\/10.1016\/J.JAMCOLLSURG.2010.12.006","journal-title":"J Am Coll Surg"},{"key":"2008_CR24","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1007\/s00423-009-0466-z","volume":"395","author":"C Schug-pass","year":"2010","unstructured":"Schug-pass C, Lippert H (2010) Mesh fixation with fibrin glue (Tissucol\/Tisseel\u00ae) in hernia repair dependent on the mesh structure\u2014is there an optimum fibrin\u2014mesh combination?\u2014investigations on a biomechanical model. Langenbeck's Arch Surg 395:569\u2013574. \nhttps:\/\/doi.org\/10.1007\/s00423-009-0466-z","journal-title":"Langenbeck's Arch Surg"},{"key":"2008_CR25","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1007\/s00464-012-2224-5","volume":"26","author":"E Reynvoet","year":"2012","unstructured":"Reynvoet E, Berrevoet F, De Somer F, Troisi R (2012) Tensile strength testing for resorbable mesh fixation systems in laparoscopic ventral hernia repair. Surg Endosc 26:2513\u20132520. \nhttps:\/\/doi.org\/10.1007\/s00464-012-2224-5","journal-title":"Surg Endosc"},{"key":"2008_CR26","first-page":"185","volume":"13","author":"L Roland","year":"2008","unstructured":"Roland L (2008) Tissue attachment strength and adhesion formation of intraabdominal fixed meshes with cyanoacrylat glues. Eur J Med Res 13:185","journal-title":"Eur J Med Res"},{"issue":"1","key":"2008_CR27","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.jamcollsurg.2010.08.015","volume":"212","author":"E Rieder","year":"2010","unstructured":"Rieder E, Stoiber M, Scheikl V et al (2010) Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes. ACS 212(1):80\u201386. \nhttps:\/\/doi.org\/10.1016\/j.jamcollsurg.2010.08.015","journal-title":"ACS"},{"key":"2008_CR28","doi-asserted-by":"publisher","first-page":"441","DOI":"10.2214\/ajr.182.2.1820441","volume":"182","author":"A Agarwal","year":"2004","unstructured":"Agarwal A, Breiman RS, Coakley FV (2004) Peritoneal calcification : causes and distinguishing features on CT. Am J Roentgenol 182:441\u2013445","journal-title":"Am J Roentgenol"},{"issue":"3","key":"2008_CR29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0093514","volume":"9","author":"J Shen","year":"2014","unstructured":"Shen J, Nair A, Saxena R, Zhang CC, Borrelli J Jr, Tang L (2014) Tissue engineering bone using autologous progenitor cells in the peritoneum. PLoS ONE 9(3):1\u20137. \nhttps:\/\/doi.org\/10.1371\/journal.pone.0093514","journal-title":"PLoS ONE"},{"key":"2008_CR30","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1159\/000328003","volume":"195","author":"O Paper","year":"2012","unstructured":"Paper O (2012) Estrogen and its receptor enhance mechanobiological effects in compressed bone mesenchymal stem cells. Cells Tissues Organs 195:400\u2013413. \nhttps:\/\/doi.org\/10.1159\/000328003","journal-title":"Cells Tissues Organs"}],"container-title":["Hernia"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-019-02008-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10029-019-02008-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-019-02008-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,17]],"date-time":"2020-07-17T23:25:54Z","timestamp":1595028354000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10029-019-02008-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,19]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["2008"],"URL":"https:\/\/doi.org\/10.1007\/s10029-019-02008-5","relation":{},"ISSN":["1265-4906","1248-9204"],"issn-type":[{"value":"1265-4906","type":"print"},{"value":"1248-9204","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,19]]},"assertion":[{"value":"17 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Author RV, author CM, author CG, author YM, author MN, author FV, and author JO declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All applicable international, national, and institutional guidelines for the care and use of animals were followed: Resolution No .9769 of directorate general for environmental policy, Generalitat de Catalunya, Spain.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This study does not contain any studies directly involving human participants\n.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"For this type of study formal consent was not necessary.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}