{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,12]],"date-time":"2026-04-12T23:36:20Z","timestamp":1776036980985,"version":"3.50.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T00:00:00Z","timestamp":1704412800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T00:00:00Z","timestamp":1704412800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"British Hernia Society"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Hernia"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>This study uses free-floating contractile fibroblast-populated collagen matrices (FPCMs) to test the shrinkage of different hernia mesh products. We hope to present this model as a proof of concept for the development of in vitro hernia mesh testing\u2014a novel technology with interesting potential.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>FPCMs were formed by seeding Human Dermal Fibroblasts into collagen gels. FPCMs were seeded with three different cell densities and cast at a volume of 500\u00a0\u03bcl into 24-well plates. Five different mesh products were embedded within the collagen constructs. Gels were left to float freely within culture media and contract over 5\u00a0days. Photographs were taken daily and the area of the collagen gel and mesh were measured. Media samples were taken at days 2 and 4 for the purposes of measuring MMP-9 release. After 5\u00a0days, dehydrated FPCMs were also examined under light and fluorescence microscopy to assess cell morphology.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Two mesh products\u2014the mosquito net and large pore lightweight mesh were found to shrink notably more than others. This pattern persisted across all three cell densities. There were no appreciable differences observed in MMP-9 release between products.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This study has successfully demonstrated that commercial mesh products can be successfully integrated into free-floating contractile FPCMs. Not only this, but FPCMs are capable of applying a contractile force upon those mesh products\u2014eliciting different levels of contraction between mesh products. Such findings demonstrate this technique as a useful proof of concept for future development of in vitro hernia mesh testing.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10029-023-02941-6","type":"journal-article","created":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T15:02:26Z","timestamp":1704466946000},"page":"495-505","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Assessment of mesh shrinkage using fibroblast-populated collagen matrices: a proof of concept for in vitro hernia mesh testing"],"prefix":"10.1007","volume":"28","author":[{"given":"R.","family":"Khader","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3126-1409","authenticated-orcid":false,"given":"T.","family":"Whitehead-Clarke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V.","family":"Mudera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Kureshi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,1,5]]},"reference":[{"issue":"7431","key":"2941_CR1","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1136\/bmj.328.7431.59","volume":"328","author":"A Kingsnorth","year":"2004","unstructured":"Kingsnorth A (2004) Treating inguinal hernias. BMJ 328(7431):59\u201360. https:\/\/doi.org\/10.1136\/bmj.328.7431.59","journal-title":"BMJ"},{"key":"2941_CR2","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.cmrp.2018.08.005","volume":"8","author":"S Idrees","year":"2018","unstructured":"Idrees S, Jindal S, Gupta MK, Sarangi R (2018) Surgical meshes\u2014the search continues. Curr Med Res Pract 8:177\u2013182","journal-title":"Curr Med Res Pract"},{"issue":"2","key":"2941_CR3","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1080\/08941939.2020.1830318","volume":"35","author":"CR Deeken","year":"2022","unstructured":"Deeken CR, Gagne DH, Badhwar A (2022) Mechanical and histological characteristics of Phasix\u2122 ST Mesh in a porcine model of hernia repair. J Invest Surg 35(2):415\u2013423. https:\/\/doi.org\/10.1080\/08941939.2020.1830318","journal-title":"J Invest Surg"},{"issue":"5","key":"2941_CR4","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1016\/0002-9610(59)90256-9","volume":"97","author":"FC Usher","year":"1959","unstructured":"Usher FC (1959) A new plastic prosthesis for repairing tissue defects of the chest and abdominal wall. Am J Surg 97(5):629\u2013633. https:\/\/doi.org\/10.1016\/0002-9610(59)90256-9","journal-title":"Am J Surg"},{"key":"2941_CR5","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/978-3-642-00534-3_19","volume-title":"Bioengineering research of chronic wounds: a multidisciplinary study approach","author":"L Procter","year":"2009","unstructured":"Procter L, Falco EE, Fisher JP, Roth JS (2009) Abdominal wall hernias and biomaterials. In: Gefen A (ed) Bioengineering research of chronic wounds: a multidisciplinary study approach. Springer, Berlin, pp 425\u2013447"},{"issue":"6","key":"2941_CR6","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.ijsu.2012.05.002","volume":"10","author":"Y Bilsel","year":"2012","unstructured":"Bilsel Y, Abci I (2012) The search for ideal hernia repair; mesh materials and types. Int J Surg 10(6):317\u2013321. https:\/\/doi.org\/10.1016\/j.ijsu.2012.05.002","journal-title":"Int J Surg"},{"issue":"3","key":"2941_CR7","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1007\/s10029-012-0913-6","volume":"16","author":"U Klinge","year":"2012","unstructured":"Klinge U, Klosterhalfen B (2012) Modified classification of surgical meshes for hernia repair based on the analyses of 1000 explanted meshes. Hernia 16(3):251\u2013258. https:\/\/doi.org\/10.1007\/s10029-012-0913-6","journal-title":"Hernia"},{"key":"2941_CR8","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.jmbbm.2014.11.011","volume":"42","author":"SP Lake","year":"2015","unstructured":"Lake SP, Ray S, Zihni AM, Thompson DM Jr, Gluckstein J, Deeken CR (2015) Pore size and pore shape\u2014but not mesh density\u2014alter the mechanical strength of tissue ingrowth and host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair. J Mech Behav Biomed Mater 42:186\u2013197. https:\/\/doi.org\/10.1016\/j.jmbbm.2014.11.011","journal-title":"J Mech Behav Biomed Mater"},{"issue":"4","key":"2941_CR9","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1089\/sur.2020.325","volume":"22","author":"T Whitehead-Clarke","year":"2021","unstructured":"Whitehead-Clarke T, Windsor A (2021) Surgical site infection: the scourge of abdominal wall reconstruction. Surg Infect (Larchmt) 22(4):357\u2013362. https:\/\/doi.org\/10.1089\/sur.2020.325","journal-title":"Surg Infect (Larchmt)"},{"issue":"2","key":"2941_CR10","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s10029-019-01898-9","volume":"23","author":"HB Cunningham","year":"2019","unstructured":"Cunningham HB, Weis JJ, Taveras LR, Huerta S (2019) Mesh migration following abdominal hernia repair: a comprehensive review. Hernia 23(2):235\u2013243. https:\/\/doi.org\/10.1007\/s10029-019-01898-9","journal-title":"Hernia"},{"key":"2941_CR11","doi-asserted-by":"publisher","first-page":"2018:bcr2017222","DOI":"10.1136\/bcr-2017-222202","volume":"24","author":"TI Whitehead-Clarke","year":"2018","unstructured":"Whitehead-Clarke TI, Smew F, Zaidi A, Pissas D (2018) A mesh masquerading as malignancy: a cancer misdiagnosed. BMJ Case Rep 24:2018:bcr2017222202. https:\/\/doi.org\/10.1136\/bcr-2017-222202","journal-title":"BMJ Case Rep"},{"issue":"2","key":"2941_CR12","doi-asserted-by":"publisher","first-page":"64","DOI":"10.31138\/mjr.28.2.64","volume":"28","author":"A Watad","year":"2017","unstructured":"Watad A, Sharif K, Shoenfeld Y (2017) The ASIA syndrome: basic concepts. Mediterr J Rheumatol 28(2):64\u201369. https:\/\/doi.org\/10.31138\/mjr.28.2.64","journal-title":"Mediterr J Rheumatol"},{"key":"2941_CR13","unstructured":"Regulation (EU) 2017\/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001\/83\/EC, Regulation (EC) No 178\/2002 and Regulation (EC) No 1223\/2009 and repealing Council Directives 90\/385\/EEC and 93\/42\/EEC (Text with EEA relevance) Text with EEA relevance (2017) Accessed 28 Nov 2019"},{"key":"2941_CR14","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1007\/s11605-021-05227-3","volume":"26","author":"T Whitehead-Clarke","year":"2021","unstructured":"Whitehead-Clarke T, Beynon V, Banks J, Karanjia R, Mudera V, Windsor A, Kureshi A (2021) A systematic review examining the experimental methodology behind in vivo testing of hiatus hernia and diaphragmatic hernia mesh. J Gastrointest Surg 26:684\u2013692. https:\/\/doi.org\/10.1007\/s11605-021-05227-3","journal-title":"J Gastrointest Surg"},{"key":"2941_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s10029-020-02360-x","author":"T Whitehead-Clarke","year":"2021","unstructured":"Whitehead-Clarke T, Karanjia R, Banks J, Beynon V, Parker S, Sanders D, Mudera V, Windsor A, Kureshi A (2021) The experimental methodology and comparators used for in vivo hernia mesh testing: a 10-year scoping review. Hernia. https:\/\/doi.org\/10.1007\/s10029-020-02360-x","journal-title":"Hernia"},{"issue":"1","key":"2941_CR16","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1177\/1528083717690613","volume":"48","author":"N Sanbhal","year":"2018","unstructured":"Sanbhal N, Miao L, Xu R, Khatri A, Wang L (2018) Physical structure and mechanical properties of knitted hernia mesh materials: a review. J Ind Text 48(1):333\u2013360. https:\/\/doi.org\/10.1177\/1528083717690613","journal-title":"J Ind Text"},{"issue":"6","key":"2941_CR17","doi-asserted-by":"publisher","first-page":"2822","DOI":"10.1007\/s00464-017-5987-x","volume":"32","author":"F Muysoms","year":"2018","unstructured":"Muysoms F, Beckers R, Kyle-Leinhase I (2018) Prospective cohort study on mesh shrinkage measured with MRI after laparoscopic ventral hernia repair with an intraperitoneal iron oxide-loaded PVDF mesh. Surg Endosc 32(6):2822\u20132830. https:\/\/doi.org\/10.1007\/s00464-017-5987-x","journal-title":"Surg Endosc"},{"issue":"1","key":"2941_CR18","doi-asserted-by":"publisher","first-page":"3894","DOI":"10.1038\/s41598-023-31088-8","volume":"13","author":"I Watanobe","year":"2023","unstructured":"Watanobe I, Miyano S, Machida M, Sugo H (2023) Mesh shrinkage after transabdominal preperitoneal inguinal hernia repair. Sci Rep 13(1):3894. https:\/\/doi.org\/10.1038\/s41598-023-31088-8","journal-title":"Sci Rep"},{"issue":"1","key":"2941_CR19","doi-asserted-by":"publisher","first-page":"79","DOI":"10.37358\/MP.18.1.4967","volume":"55","author":"B Socea","year":"2018","unstructured":"Socea B, Socea LI, Bratu OG, Mastalier B, Dimitriu M, Carap A, Constantin VD (2018) Recurrence rates and mesh shrinkage after polypropylene vs. polyester mesh hernia repair in complicated hernias. Revista de Materiale Plastice 55(1):79\u201381","journal-title":"Revista de Materiale Plastice"},{"issue":"3","key":"2941_CR20","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.1073\/pnas.76.3.1274","volume":"76","author":"E Bell","year":"1979","unstructured":"Bell E, Ivarsson B, Merrill C (1979) Production of a tissue-like structure by contraction of collagen lattices by human fibroblasts of different proliferative potential in vitro. Proc Natl Acad Sci USA 76(3):1274\u20131278. https:\/\/doi.org\/10.1073\/pnas.76.3.1274","journal-title":"Proc Natl Acad Sci USA"},{"issue":"2","key":"2941_CR21","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1111\/j.1067-1927.2004.012208.x","volume":"12","author":"MA Carlson","year":"2004","unstructured":"Carlson MA, Longaker MT (2004) The fibroblast-populated collagen matrix as a model of wound healing: a review of the evidence. Wound Repair Regen 12(2):134\u2013147. https:\/\/doi.org\/10.1111\/j.1067-1927.2004.012208.x","journal-title":"Wound Repair Regen"},{"issue":"1","key":"2941_CR22","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/s10029-021-02401-z","volume":"26","author":"A Grillo","year":"2022","unstructured":"Grillo A, Hyder Z, Mudera V, Kureshi A (2022) In vitro characterisation of low-cost synthetic meshes intended for hernia repair in the UK. Hernia 26(1):325\u2013334. https:\/\/doi.org\/10.1007\/s10029-021-02401-z","journal-title":"Hernia"},{"issue":"2","key":"2941_CR23","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1136\/bmjinnov-2020-000535","volume":"7","author":"M Skopec","year":"2021","unstructured":"Skopec M, Grillo A, Kureshi A, Bhatti Y, Harris M (2021) Double standards in healthcare innovations: the case of mosquito net mesh for hernia repair. BMJ Innovations 7(2):482. https:\/\/doi.org\/10.1136\/bmjinnov-2020-000535","journal-title":"BMJ Innovations"},{"key":"2941_CR24","unstructured":"Lonza RAFT 3D cell culture kit. Westburg Life Sciences. https:\/\/www.westburg.eu\/knowledge\/immunotherapy\/tools#protocols. Accessed 07 May 2023"},{"key":"2941_CR25","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.actbio.2017.11.047","volume":"67","author":"D Mukhey","year":"2018","unstructured":"Mukhey D, Phillips JB, Daniels JT, Kureshi AK (2018) Controlling human corneal stromal stem cell contraction to mediate rapid cell and matrix organization of real architecture for 3-dimensional tissue equivalents. Acta Biomater 67:229\u2013237. https:\/\/doi.org\/10.1016\/j.actbio.2017.11.047","journal-title":"Acta Biomater"},{"issue":"1","key":"2941_CR26","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1007\/s10029-016-1528-0","volume":"21","author":"S Harslof","year":"2017","unstructured":"Harslof S, Zinther N, Harslof T, Danielsen C, Wara P, Friis-Andersen H (2017) Mesh shrinkage depends on mesh properties and anchoring device: an experimental long-term study in sheep. Hernia: the journal of hernias and abdominal wall surgery 21(1):107\u2013113. https:\/\/doi.org\/10.1007\/s10029-016-1528-0","journal-title":"Hernia: the journal of hernias and abdominal wall surgery"},{"issue":"4","key":"2941_CR27","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1308\/003588410x12664192076296","volume":"92","author":"CN Brown","year":"2010","unstructured":"Brown CN, Finch JG (2010) Which mesh for hernia repair? Ann R Coll Surg Engl 92(4):272\u2013278. https:\/\/doi.org\/10.1308\/003588410x12664192076296","journal-title":"Ann R Coll Surg Engl"},{"issue":"6","key":"2941_CR28","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1049\/nbt2.12015","volume":"15","author":"D Feh\u00e9r","year":"2021","unstructured":"Feh\u00e9r D, Ferencz A, Szab\u00f3 G, Juhos K, Csuk\u00e1s D, Voniatis C, Reininger L, Moln\u00e1r K, Jedlovszky-Hajd\u00fa A, W\u00e9ber G (2021) Early and late effects of absorbable poly(vinyl alcohol) hernia mesh to tissue reconstruction. IET Nanobiotechnol 15(6):565\u2013574. https:\/\/doi.org\/10.1049\/nbt2.12015","journal-title":"IET Nanobiotechnol"},{"key":"2941_CR29","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2020.589223","volume":"8","author":"G Giuntoli","year":"2020","unstructured":"Giuntoli G, Muzio G, Actis C, Ganora A, Calzone S, Bruno M, Ciardelli G, Carmagnola I, Tonda-Turo C (2020) In-vitro characterization of a hernia mesh featuring a nanostructured coating. Front Bioeng Biotechnol 8:589223. https:\/\/doi.org\/10.3389\/fbioe.2020.589223","journal-title":"Front Bioeng Biotechnol"},{"issue":"6","key":"2941_CR30","doi-asserted-by":"publisher","first-page":"1586","DOI":"10.1002\/jbm.b.33697","volume":"105","author":"G Muzio","year":"2017","unstructured":"Muzio G, Perero S, Miola M, Oraldi M, Ferraris S, Vern\u00e8 E, Festa F, Canuto RA, Festa V, Ferraris M (2017) Biocompatibility versus peritoneal mesothelial cells of polypropylene prostheses for hernia repair, coated with a thin silica\/silver layer. J Biomed Mater Res B Appl Biomater 105(6):1586\u20131593. https:\/\/doi.org\/10.1002\/jbm.b.33697","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"3","key":"2941_CR31","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1016\/j.surg.2011.06.011","volume":"150","author":"EJ Culbertson","year":"2011","unstructured":"Culbertson EJ, Xing L, Wen Y, Franz MG (2011) Loss of mechanical strain impairs abdominal wall fibroblast proliferation, orientation, and collagen contraction function. Surgery 150(3):410\u2013417. https:\/\/doi.org\/10.1016\/j.surg.2011.06.011","journal-title":"Surgery"},{"issue":"5","key":"2941_CR32","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1038\/nrm809","volume":"3","author":"JJ Tomasek","year":"2002","unstructured":"Tomasek JJ, Gabbiani G, Hinz B, Chaponnier C, Brown RA (2002) Myofibroblasts and mechano-regulation of connective tissue remodelling. Nat Rev Mol Cell Biol 3(5):349\u2013363. https:\/\/doi.org\/10.1038\/nrm809","journal-title":"Nat Rev Mol Cell Biol"},{"issue":"2","key":"2941_CR33","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1243\/0954411981533854","volume":"212","author":"M Eastwood","year":"1998","unstructured":"Eastwood M, McGrouther DA, Brown RA (1998) Fibroblast responses to mechanical forces. Proc Inst Mech Eng H J Eng Med 212(2):85\u201392. https:\/\/doi.org\/10.1243\/0954411981533854","journal-title":"Proc Inst Mech Eng H J Eng Med"},{"issue":"1","key":"2941_CR34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/(sici)1097-0169(200001)45:1<1::Aid-cm1>3.0.Co;2-j","volume":"45","author":"VC Mudera","year":"2000","unstructured":"Mudera VC, Pleass R, Eastwood M, Tarnuzzer R, Schultz G, Khaw P, McGrouther DA, Brown RA (2000) Molecular responses of human dermal fibroblasts to dual cues: contact guidance and mechanical load. Cell Motil Cytoskeleton 45(1):1\u20139. https:\/\/doi.org\/10.1002\/(sici)1097-0169(200001)45:1%3c1::Aid-cm1%3e3.0.Co;2-j","journal-title":"Cell Motil Cytoskeleton"},{"issue":"11","key":"2941_CR35","doi-asserted-by":"publisher","first-page":"L1006","DOI":"10.1152\/ajplung.00015.2014","volume":"306","author":"T Kobayashi","year":"2014","unstructured":"Kobayashi T, Kim H, Liu X, Sugiura H, Kohyama T, Fang Q, Wen FQ, Abe S, Wang X, Atkinson JJ, Shipley JM, Senior RM, Rennard SI (2014) Matrix metalloproteinase-9 activates TGF-\u03b2 and stimulates fibroblast contraction of collagen gels. Am J Physiol Lung Cell Mol Physiol 306(11):L1006\u2013L1015. https:\/\/doi.org\/10.1152\/ajplung.00015.2014","journal-title":"Am J Physiol Lung Cell Mol Physiol"},{"issue":"3","key":"2941_CR36","doi-asserted-by":"publisher","first-page":"1104","DOI":"10.1167\/iovs.02-0412","volume":"44","author":"JT Daniels","year":"2003","unstructured":"Daniels JT, Cambrey AD, Occleston NL, Garrett Q, Tarnuzzer RW, Schultz GS, Khaw PT (2003) Matrix metalloproteinase inhibition modulates fibroblast-mediated matrix contraction and collagen production in vitro. Invest Ophthalmol Vis Sci 44(3):1104\u20131110. https:\/\/doi.org\/10.1167\/iovs.02-0412","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"5","key":"2941_CR37","doi-asserted-by":"publisher","DOI":"10.1002\/cpz1.788","volume":"3","author":"T Whitehead-Clarke","year":"2023","unstructured":"Whitehead-Clarke T, Grillo A, Mudera V, Kureshi A (2023) The isolation, culture, and cryopreservation of human rectus sheath fibroblasts. Curr Protoc 3(5):e788. https:\/\/doi.org\/10.1002\/cpz1.788","journal-title":"Curr Protoc"}],"container-title":["Hernia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-023-02941-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10029-023-02941-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-023-02941-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,5]],"date-time":"2024-04-05T13:07:04Z","timestamp":1712322424000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10029-023-02941-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,5]]},"references-count":37,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["2941"],"URL":"https:\/\/doi.org\/10.1007\/s10029-023-02941-6","relation":{},"ISSN":["1248-9204"],"issn-type":[{"value":"1248-9204","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,5]]},"assertion":[{"value":"10 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no other conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This work required no additional ethical considerations.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"No animal of human subjects were used for this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"This work did not require informed consent of any subjects.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}