{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T20:59:14Z","timestamp":1768597154436,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T00:00:00Z","timestamp":1768521600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T00:00:00Z","timestamp":1768521600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Hernia"],"DOI":"10.1007\/s10029-025-03552-z","type":"journal-article","created":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T10:33:14Z","timestamp":1768559594000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Less pain and foreign body sensation after incisional hernia repair with partially absorbable mesh than with non-absorbable mesh: a retrospective sequential cohort study"],"prefix":"10.1007","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-6720-6279","authenticated-orcid":false,"given":"Hessa","family":"Alsuwaidan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-5957-2950","authenticated-orcid":false,"given":"Fran\u00e7ois","family":"Ansart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alya","family":"Bellemin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3904-6888","authenticated-orcid":false,"given":"M\u00e9gane","family":"Homa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6735-9769","authenticated-orcid":false,"given":"David","family":"Moszkowicz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,16]]},"reference":[{"key":"3552_CR1","doi-asserted-by":"publisher","first-page":"e0138745","DOI":"10.1371\/journal.pone.0138745","volume":"One10","author":"DC Bosanquet","year":"2015","unstructured":"Bosanquet DC, Ansell J, Abdelrahman T, Cornish J, Harries R, Stimpson A et al (2015) Systematic review and Meta-Regression of factors affecting midline incisional hernia rates: analysis of 14,618 patients. PLoS One10:e0138745","journal-title":"PLoS"},{"key":"3552_CR2","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1089\/sur.2015.124","volume":"17","author":"JL Holihan","year":"2016","unstructured":"Holihan JL, Askenasy EP, Greenberg JA, Keith JN, Martindale RG, Roth JS et al (2016) Component separation vs. Bridged repair for large ventral hernias: A Multi-Institutional Risk-Adjusted Comparison, systematic Review, and Meta-Analysis. Surg Infect 17:17\u201326","journal-title":"Surg Infect"},{"key":"3552_CR3","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s10029-013-1066-y","volume":"18","author":"A Eriksson","year":"2014","unstructured":"Eriksson A, Rosenberg J, Bisgaard T (2014) Surgical treatment for giant incisional hernia: a qualitative systematic review. Hernia 18:31\u201338","journal-title":"Hernia"},{"key":"3552_CR4","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1097\/01.sla.0000141193.08524.e7","volume":"240","author":"JWA Burger","year":"2004","unstructured":"Burger JWA, Luijendijk RW, Hop WCJ, Halm JA, Verdaasdonk EGG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg 240:578\u2013583","journal-title":"Ann Surg"},{"key":"3552_CR5","doi-asserted-by":"publisher","first-page":"2773","DOI":"10.1007\/s00464-011-1799-6","volume":"25","author":"R Bittner","year":"2011","unstructured":"Bittner R, Arregui ME, Bisgaard T, Dudai M, Ferzli GS, Fitzgibbons RJ et al (2011) Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia [International endohernia society (IEHS)]. Surg Endosc 25:2773\u20132843","journal-title":"Surg Endosc"},{"key":"3552_CR6","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1056\/NEJM200008103430603","volume":"343","author":"RW Luijendijk","year":"2000","unstructured":"Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343:392\u2013398","journal-title":"N Engl J Med"},{"key":"3552_CR7","doi-asserted-by":"publisher","first-page":"226","DOI":"10.4240\/wjgs.v7.i10.226","volume":"7","author":"LM Zhu","year":"2015","unstructured":"Zhu LM, Schuster P, Klinge U (2015) Mesh implants: an overview of crucial mesh parameters. World J Gastrointest Surg 7:226\u2013236","journal-title":"World J Gastrointest Surg"},{"key":"3552_CR8","first-page":"754","volume":"60","author":"P Negro","year":"2008","unstructured":"Negro P, Gossetti F, D\u2019Amore L (2008) Open abdominal surgery for large incisional hernia: proposal of a personal technique. Chir Ital 60:754","journal-title":"Chir Ital"},{"key":"3552_CR9","first-page":"125","volume":"28","author":"K Handojo","year":"2016","unstructured":"Handojo K, Meylemans D, Devroe K, Vermeiren K, Aelvoet C, Tollens T (2016) Initial experience with a new macroporous partially absorbable mesh: introducing Ultrapro\u00ae AdvancedTM. Surg Technol Int 28:125\u201330","journal-title":"Surg Technol Int"},{"key":"3552_CR10","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1016\/j.jviscsurg.2024.07.006","volume":"161","author":"AZ Bellemin","year":"2024","unstructured":"Bellemin AZ, Belloni E, Moszkowicz D (2024) Posterior component separation for the treatment of a complex incisional hernia: surgical technique (with video). J Visc Surg 161:330\u2013332","journal-title":"J Visc Surg"},{"key":"3552_CR11","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1007\/s10029-019-01924-w","volume":"23","author":"JF Gillion","year":"2019","unstructured":"Gillion JF, Lepere M, Barrat C, Cas O, Dabrowski A, Jurczak F et al (2019) Two-year patient-related outcome measures (PROM) of primary ventral and incisional hernia repair using a novel three-dimensional composite polyester monofilament mesh: the SymCHro registry study. Hernia 23:767\u2013781","journal-title":"Hernia"},{"key":"3552_CR12","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1093\/bjs\/znad284","volume":"110","author":"DL Sanders","year":"2023","unstructured":"Sanders DL, Pawlak MM, Simons MP, Aufenacker T, Balla A, Berger C et al (2023) Midline incisional hernia guidelines: the European Hernia Society. Br J Surg 110:1732\u201368","journal-title":"Br J Surg"},{"key":"3552_CR13","doi-asserted-by":"crossref","unstructured":"Basukala S, Gupta RK, Thapa N, Rayamajhi BB, Mishra R, Mandal P (2021) Transversus abdominis release for complex incisional hernias-a case report. J Surg Case Rep (7):rjab281","DOI":"10.1093\/jscr\/rjab281"},{"key":"3552_CR14","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1001\/jamasurg.2023.4847","volume":"158","author":"BT Miller","year":"2023","unstructured":"Miller BT, Ellis RC, Petro CC, Krpata DM, Prabhu AS, Beffa LRA et al (2023) Quantitative tension on the abdominal wall in posterior components separation with transversus abdominis release. JAMA Surg 158:1321\u20131326","journal-title":"JAMA Surg"},{"key":"3552_CR15","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1007\/s10029-025-03455-z","volume":"29","author":"D Remulla","year":"2025","unstructured":"Remulla D, Woo KP, Bennett WC, Carvalho A, Slatnick BL, Blackman MH (2025) Predicting fascial non-closure in ventral hernia repair with transversus abdominis release: risk factors, clinical outcomes, and implications for surgical planning. Hernia 29:268","journal-title":"Hernia"},{"key":"3552_CR16","doi-asserted-by":"publisher","first-page":"198","DOI":"10.21614\/sgo-460","volume":"27","author":"MH Goda","year":"2022","unstructured":"Goda MH, Abdelrahim HS, Elmaleh HM, Amer AF, Fadl EMA (2022) Transversus abdominis release versus anterior component separation in ventral abdominal hernia \u2013 a prospective comparative study. Surg Gastroenterol Oncol 27:198\u2013207","journal-title":"Surg Gastroenterol Oncol"},{"key":"3552_CR17","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s10029-025-03487-5","volume":"29","author":"AY Mohamedahmed","year":"2025","unstructured":"Mohamedahmed AY, Issa MT, Zaman S et al (2025) Outcomes of anterior component separation versus posterior component separation with transversus abdominis muscle release for large incisional hernias: a systematic review and meta-analysis. Hernia 29:289","journal-title":"Hernia"},{"key":"3552_CR18","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.cej.2018.01.010","volume":"340","author":"D Da Silva","year":"2018","unstructured":"Da Silva D, Kaduri M, Poley M, Adir O, Krinsky N, Shainsky-Roitman J et al (2018) Biocompatibility, biodegradation and excretion of polylactic acid (PLA) in medical implants and theranostic systems. Chem Eng J 340:9\u201314","journal-title":"Chem Eng J"},{"key":"3552_CR19","doi-asserted-by":"publisher","first-page":"369","DOI":"10.2147\/MDER.S198988","volume":"12","author":"C Totten","year":"2019","unstructured":"Totten C, Becker P, Lourd M, Roth JS (2019) Polyester vs polypropylene, do mesh materials matter? A meta-analysis and systematic review. Med Devices 12:369\u2013378","journal-title":"Med Devices"},{"key":"3552_CR20","first-page":"388","volume":"6","author":"B Agca","year":"2019","unstructured":"Agca B, Iscan Y, Memisoglu K (2019) Early results of comparison of polypropylene mesh and 75% resorbable mesh (monofilament polypropylene and poly-L-lactic acid (PLLA) mesh) for laparoscopic total extraperitoneal (TEP) inguinal hernia repair. North Clin Istanb 6:388\u2013392","journal-title":"North Clin Istanb"},{"key":"3552_CR21","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1001\/jamasurg.2021.6902","volume":"157","author":"MJ Rosen","year":"2022","unstructured":"Rosen MJ, Krpata DM, Petro CC, Carbonell A, Warren J, Poulose BK et al (2022) Biologic vs synthetic mesh for single-stage repair of contaminated ventral hernias: a randomized clinical trial. JAMA Surg 157:293\u2013301","journal-title":"JAMA Surg"},{"key":"3552_CR22","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s10029-022-02616-8","volume":"27","author":"T Layer","year":"2023","unstructured":"Layer T, Benammi S, Dubuisson V, Manfredelli S, Passot G, Charleux-Muller D et al (2023) Incisional hernia repair with a slowly absorbable P4HB mesh: what happens after the mesh disappears? A retrospective longitudinal clinical study. Hernia 27:387\u2013394","journal-title":"Hernia"},{"key":"3552_CR23","doi-asserted-by":"crossref","unstructured":"Aldohayan A, Alamri H, Aljunidel R, Alotaibi A, Alosaimi M, Alburakan A et al (2021) Laparoscopic ventral hernia repair with Poly-4-Hydroxybutyrate absorbable barrier composite mesh. JSLS 25:e2020.00105","DOI":"10.4293\/JSLS.2020.00105"},{"key":"3552_CR24","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1007\/s10029-024-02981-6","volume":"28","author":"J Bueno-Lled\u00f3","year":"2024","unstructured":"Bueno-Lled\u00f3 J, Porrero-Guerrero B, Ferreira F, Pe\u00f1a-Soria MJ, Sanz-S\u00e1nchez M, Mansilla-Rosell\u00f3 A et al (2024) Long-term results with biosynthetic absorbable P4HB mesh in ventral abdominal wall repair: a multicentre analysis. Hernia 28:1103\u20131112","journal-title":"Hernia"},{"key":"3552_CR25","doi-asserted-by":"publisher","first-page":"1280991","DOI":"10.3389\/fsurg.2023.1280991","volume":"10","author":"CR Deeken","year":"2023","unstructured":"Deeken CR, Rosen MJ, Poulose BK, Bradbury K, Huang LC, Ma J et al (2023) Early wound morbidity and clinical outcomes associated with P4HB mesh compared to permanent synthetic mesh in umbilical and small to medium, routine ventral hernia repairs. Front Surg 10:1280991","journal-title":"Front Surg"},{"key":"3552_CR26","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1007\/s00464-010-1432-0","volume":"25","author":"CR Deeken","year":"2011","unstructured":"Deeken CR, Abdo MS, Frisella MM, Matthews BD (2011) Physicomechanical evaluation of absorbable and nonabsorbable barrier composite meshes for laparoscopic ventral hernia repair. Surg Endosc 25:1541\u20131552","journal-title":"Surg Endosc"},{"key":"3552_CR27","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1007\/s10029-012-0916-3","volume":"16","author":"K Bury","year":"2012","unstructured":"Bury K, \u015amieta\u0144ski M, Polish Hernia Study Group (2012) Five-year results of a randomized clinical trial comparing a polypropylene mesh with a poliglecaprone and polypropylene composite mesh for inguinal hernioplasty. Hernia 16:549\u2013553","journal-title":"Hernia"},{"key":"3552_CR28","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1002\/bjs.4387","volume":"91","author":"S Post","year":"2004","unstructured":"Post S, Weiss B, Willer M, Neufang T, Lorenz D (2004) Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg 91:44\u201348","journal-title":"Br J Surg"}],"container-title":["Hernia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-025-03552-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10029-025-03552-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-025-03552-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T10:33:20Z","timestamp":1768559600000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10029-025-03552-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,16]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3552"],"URL":"https:\/\/doi.org\/10.1007\/s10029-025-03552-z","relation":{},"ISSN":["1248-9204"],"issn-type":[{"value":"1248-9204","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,16]]},"assertion":[{"value":"28 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"David MOSZKOWICZ reports having received consulting fees from Cousin Biotech. Hessa ALSUWAIDAN, Alya BELLEMIN and Fran\u00e7ois ANSART have no biomedical financial interests or potential conflicts of interest to declare. M\u00e9gane Homa is employed by Cousin Biotech.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interests"}}],"article-number":"68"}}