{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T13:57:37Z","timestamp":1770818257690,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T00:00:00Z","timestamp":1770768000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T00:00:00Z","timestamp":1770768000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Hernia"],"DOI":"10.1007\/s10029-026-03592-z","type":"journal-article","created":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T12:20:03Z","timestamp":1770812403000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ergonomic evaluation of a novel suturing device (SutureTOOL) versus traditional needle-driver for aponeurotic closure: a randomized experimental study"],"prefix":"10.1007","volume":"30","author":[{"given":"Diane","family":"Bernard de Lajartre","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8077-0288","authenticated-orcid":false,"given":"Vincent","family":"Dochez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aur\u00e9lie","family":"Sarcher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thibault","family":"Thubert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,11]]},"reference":[{"key":"3592_CR1","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1002\/bjs.9364","volume":"101","author":"C Fink","year":"2014","unstructured":"Fink C, Baumann P, Wente MN et al (2014) Incisional hernia rate 3 years after midline laparotomy. J Br Surg 101:51\u201354. https:\/\/doi.org\/10.1002\/bjs.9364","journal-title":"J Br Surg"},{"key":"3592_CR2","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.amjsurg.2012.01.012","volume":"204","author":"GH van Ramshorst","year":"2012","unstructured":"van Ramshorst GH, Eker HH, Hop WCJ et al (2012) Impact of incisional hernia on health-related quality of life and body image: a prospective cohort study. Am J Surg 204:144\u2013150. https:\/\/doi.org\/10.1016\/j.amjsurg.2012.01.012","journal-title":"Am J Surg"},{"key":"3592_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10029-014-1342-5","volume":"19","author":"FE Muysoms","year":"2015","unstructured":"Muysoms FE, Antoniou SA, Bury K et al (2015) European Hernia Society guidelines on the closure of abdominal wall incisions. Hernia 19:1\u201324. https:\/\/doi.org\/10.1007\/s10029-014-1342-5","journal-title":"Hernia"},{"key":"3592_CR4","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1097\/SLA.0b013e3181d973e4","volume":"251","author":"MK Diener","year":"2010","unstructured":"Diener MK, Voss S, Jensen K et al (2010) Elective midline laparotomy closure: the INLINE systematic review and meta-analysis. Ann Surg 251:843\u2013856. https:\/\/doi.org\/10.1097\/SLA.0b013e3181d973e4","journal-title":"Ann Surg"},{"key":"3592_CR5","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1016\/S0140-6736(15)60459-7","volume":"386","author":"EB Deerenberg","year":"2015","unstructured":"Deerenberg EB, Harlaar JJ, Steyerberg EW et al (2015) Small bites versus large bites for closure of abdominal midline incisions (STITCH): a double-blind, multicentre, randomised controlled trial. Lancet 386:1254\u20131260. https:\/\/doi.org\/10.1016\/S0140-6736(15)60459-7","journal-title":"Lancet"},{"key":"3592_CR6","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/s10029-002-0070-4","volume":"6","author":"JJ H\u00f6er","year":"2002","unstructured":"H\u00f6er JJ, Junge K, Schachtrupp A et al (2002) Influence of laparotomy closure technique on collagen synthesis in the incisional region. Hernia 6:93\u201398. https:\/\/doi.org\/10.1007\/s10029-002-0070-4","journal-title":"Hernia"},{"key":"3592_CR7","doi-asserted-by":"publisher","first-page":"1712","DOI":"10.1007\/s00464-009-0834-3","volume":"24","author":"GPY Szeto","year":"2010","unstructured":"Szeto GPY, Ho P, Ting ACW et al (2010) A study of surgeons\u2019 postural muscle activity during open, laparoscopic, and endovascular surgery. Surg Endosc 24:1712\u20131721. https:\/\/doi.org\/10.1007\/s00464-009-0834-3","journal-title":"Surg Endosc"},{"key":"3592_CR8","doi-asserted-by":"publisher","first-page":"e19","DOI":"10.1016\/j.jss.2011.08.004","volume":"172","author":"GPY Szeto","year":"2012","unstructured":"Szeto GPY, Cheng SWK, Poon JTC et al (2012) Surgeons\u2019 static posture and movement repetitions in open and laparoscopic surgery. J Surg Res 172:e19\u201331. https:\/\/doi.org\/10.1016\/j.jss.2011.08.004","journal-title":"J Surg Res"},{"key":"3592_CR9","doi-asserted-by":"publisher","first-page":"6335","DOI":"10.1007\/s00464-020-08085-3","volume":"35","author":"L Yang","year":"2021","unstructured":"Yang L, Wang T, Weidner TK et al (2021) Intraoperative musculoskeletal discomfort and risk for surgeons during open and laparoscopic surgery. Surg Endosc 35:6335\u20136343. https:\/\/doi.org\/10.1007\/s00464-020-08085-3","journal-title":"Surg Endosc"},{"key":"3592_CR10","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1055\/s-0039-1693026","volume":"32","author":"AT Schlussel","year":"2019","unstructured":"Schlussel AT, Maykel JA (2019) Ergonomics and musculoskeletal health of the surgeon. Clin Colon Rectal Surg 32:424\u2013434. https:\/\/doi.org\/10.1055\/s-0039-1693026","journal-title":"Clin Colon Rectal Surg"},{"key":"3592_CR11","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1097\/GCO.0000000000000502","volume":"30","author":"T Catanzarite","year":"2018","unstructured":"Catanzarite T, Tan-Kim J, Menefee SA (2018) Ergonomics in gynecologic surgery. Curr Opin Obstet Gynecol 30:432\u2013440. https:\/\/doi.org\/10.1097\/GCO.0000000000000502","journal-title":"Curr Opin Obstet Gynecol"},{"key":"3592_CR12","doi-asserted-by":"publisher","DOI":"10.3390\/s23031686","volume":"23","author":"J Merbah","year":"2023","unstructured":"Merbah J, Car\u00e9 BR, Gorce P et al (2023) A new approach to quantifying muscular fatigue using wearable EMG sensors during surgery: an ergonomic case study. Sensors 23:1686. https:\/\/doi.org\/10.3390\/s23031686","journal-title":"Sensors"},{"key":"3592_CR13","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1080\/13645700410033652","volume":"13","author":"S Koneczny","year":"2004","unstructured":"Koneczny S, Matern U (2004) Instruments for the evaluation of ergonomics in surgery. Minim Invasive Ther Allied Technol 13:167\u2013177. https:\/\/doi.org\/10.1080\/13645700410033652","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"3592_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.apergo.2022.103737","volume":"102","author":"J Maillet","year":"2022","unstructured":"Maillet J, Rossi J, Hug F et al (2022) Influence of experience on kinematics of upper limbs during sewing gesture. Appl Ergon 102:103737. https:\/\/doi.org\/10.1016\/j.apergo.2022.103737","journal-title":"Appl Ergon"},{"key":"3592_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00268-019-05179-5","volume":"44","author":"G B\u00f6rner","year":"2020","unstructured":"B\u00f6rner G, Montgomery A (2020) Suture-Tool: a mechanical needle driver for standardized wound closure. World J Surg 44:1. https:\/\/doi.org\/10.1007\/s00268-019-05179-5","journal-title":"World J Surg"},{"key":"3592_CR16","doi-asserted-by":"publisher","DOI":"10.1016\/j.sipas.2022.100137","volume":"11","author":"G B\u00f6rner","year":"2022","unstructured":"B\u00f6rner G, Edelhamre M, Rogmark P, Montgomery A (2022) Suture-TOOL: a suturing device for swift and standardized abdominal aponeurosis closure. Surgery in Practice and Science 11:100137. https:\/\/doi.org\/10.1016\/j.sipas.2022.100137","journal-title":"Surgery in Practice and Science"},{"key":"3592_CR17","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1016\/j.jelekin.2012.02.019","volume":"22","author":"M Gonz\u00e1lez-Izal","year":"2012","unstructured":"Gonz\u00e1lez-Izal M, Malanda A, Gorostiaga E, Izquierdo M (2012) Electromyographic models to assess muscle fatigue. J Electromyogr Kinesiol 22:501\u2013512. https:\/\/doi.org\/10.1016\/j.jelekin.2012.02.019","journal-title":"J Electromyogr Kinesiol"},{"key":"3592_CR18","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/s1050-6411(00)00027-4","volume":"10","author":"HJ Hermens","year":"2000","unstructured":"Hermens HJ, Freriks B, Disselhorst-Klug C, Rau G (2000) Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol 10:361\u2013374. https:\/\/doi.org\/10.1016\/s1050-6411(00)00027-4","journal-title":"J Electromyogr Kinesiol"},{"key":"3592_CR19","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.cmpb.2014.01.012","volume":"114","author":"A Barre","year":"2014","unstructured":"Barre A, Armand S (2014) Biomechanical toolkit: open-source framework to visualize and process biomechanical data. Comput Methods Programs Biomed 114:80\u201387. https:\/\/doi.org\/10.1016\/j.cmpb.2014.01.012","journal-title":"Comput Methods Programs Biomed"},{"key":"3592_CR20","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/0003-6870(93)90080-S","volume":"24","author":"L McAtamney","year":"1993","unstructured":"McAtamney L, Nigel Corlett E (1993) RULA: a survey method for the investigation of work-related upper limb disorders. Appl Ergon 24:91\u201399. https:\/\/doi.org\/10.1016\/0003-6870(93)90080-S","journal-title":"Appl Ergon"},{"key":"3592_CR22","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1007\/s10029-025-03378-9","volume":"29","author":"G B\u00f6rner","year":"2025","unstructured":"B\u00f6rner G, Toft L, Rogmark P, Edelhamre M (2025) A feasibility and safety trial investigating a device for swift and standardized median laparotomy closure. Hernia 29:196. https:\/\/doi.org\/10.1007\/s10029-025-03378-9","journal-title":"Hernia"},{"key":"3592_CR23","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1177\/1553350620950896","volume":"28","author":"ES Abdelall","year":"2021","unstructured":"Abdelall ES, Stone RT, Rajana Nedved L, Fales C (2021) Bend the tool, not the wrist: an ergonomic investigation of medical suturing needle holder design and medical engineering solution. Surg Innov 28:62\u201370. https:\/\/doi.org\/10.1177\/1553350620950896","journal-title":"Surg Innov"},{"key":"3592_CR24","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1007\/s004640080141","volume":"15","author":"TA Emam","year":"2001","unstructured":"Emam TA, Frank TG, Hanna GB, Cuschieri A (2001) Influence of handle design on the surgeon\u2019s upper limb movements, muscle recruitment, and fatigue during endoscopic suturing. Surg Endosc 15:667\u2013672. https:\/\/doi.org\/10.1007\/s004640080141","journal-title":"Surg Endosc"},{"key":"3592_CR25","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0313568","volume":"20","author":"A Minor-Mart\u00ednez","year":"2025","unstructured":"Minor-Mart\u00ednez A, Ordorica-Flores RM, Mota-Carmona JR et al (2025) Evaluating the performance of a new ergonomic laparoscopic needle holder for intracorporeal suturing. PLoS One 20:e0313568. https:\/\/doi.org\/10.1371\/journal.pone.0313568","journal-title":"PLoS One"},{"key":"3592_CR26","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1007\/s00464-015-4217-7","volume":"30","author":"T Bensignor","year":"2016","unstructured":"Bensignor T, Morel G, Reversat D et al (2016) Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills. Surg Endosc 30:446\u2013454. https:\/\/doi.org\/10.1007\/s00464-015-4217-7","journal-title":"Surg Endosc"},{"key":"3592_CR27","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1007\/s11548-017-1636-z","volume":"12","author":"JA S\u00e1nchez-Margallo","year":"2017","unstructured":"S\u00e1nchez-Margallo JA, S\u00e1nchez-Margallo FM (2017) Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons\u2019 task performance and ergonomics. Int J Comput Assist Radiol Surg 12:2069\u20132077. https:\/\/doi.org\/10.1007\/s11548-017-1636-z","journal-title":"Int J Comput Assist Radiol Surg"}],"container-title":["Hernia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-026-03592-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10029-026-03592-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10029-026-03592-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T12:20:04Z","timestamp":1770812404000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10029-026-03592-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,11]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3592"],"URL":"https:\/\/doi.org\/10.1007\/s10029-026-03592-z","relation":{},"ISSN":["1248-9204"],"issn-type":[{"value":"1248-9204","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,11]]},"assertion":[{"value":"18 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval was obtained from the \u201cComit\u00e9 d\u2019\u00e9thique, de d\u00e9ontologie et d\u2019int\u00e9grit\u00e9 scientifique (CEDIS)\u201d of Nantes University, which issued a favorable opinion (no. 18122024, IRB00013074).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Ethics statement"}},{"value":"The protocol was prospectively registered on the Open Science Framework (OSF) on April 14, 2025 (registration DOI: 10.17605\/OSF.IO\/38WCN).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Trial registration"}},{"value":"The experimental study was conducted as part of a research collaboration between the \u201cMotricit\u00e9, Interactions, Performance\u201d laboratory (University of Nantes, France) and Suturion AB (Sweden). Suturion AB financially supported the study through a service contract (\u20ac14,785.5 excluding taxes) covering the experimental setup, data collection, and analysis performed on the PEPSE platform. However, the company had no involvement in the experimental procedures, data interpretation, or manuscript preparation. Diane Bernard de Lajartre, Vincent Dochez and Aur\u00e9lie Sarcher declare that they have no conflict of interest. Thibault Thubert has received a speaker honorarium from Pierre Fabre, Effik and General Electrics. Thibault Thubert declare that he have no conflict of interest with this study and this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"93"}}