{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T09:52:56Z","timestamp":1769161976591,"version":"3.49.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2008,4,1]],"date-time":"2008-04-01T00:00:00Z","timestamp":1207008000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Artif Organs"],"published-print":{"date-parts":[[2008,4]]},"DOI":"10.1007\/s10047-007-0400-5","type":"journal-article","created":{"date-parts":[[2008,4,14]],"date-time":"2008-04-14T13:53:50Z","timestamp":1208181230000},"page":"29-37","source":"Crossref","is-referenced-by-count":12,"title":["Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve"],"prefix":"10.1007","volume":"11","author":[{"given":"Hiroshi","family":"Sugiki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshifumi","family":"Murashita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norihiko","family":"Shiiya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiro","family":"Matsui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Sugiki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2008,4,15]]},"reference":[{"key":"400_CR1","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/0167-5273(88)90057-5","volume":"18","author":"J.L. Gibbs","year":"1988","unstructured":"Gibbs JL, Wharton GA, Williams GJ. Doppler ultrasound of normally functioning mechanical mitral and aortic valve prostheses. Int J Cardiol 1988;18:391\u2013398","journal-title":"Int J Cardiol"},{"key":"400_CR2","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/0735-1097(89)90576-7","volume":"13","author":"M. Jones","year":"1989","unstructured":"Jones M, Eidbo EE. Doppler color flow evaluation of prosthetic mitral valves: experimental epicardial studies. J Am Coll Cardiol 1989;13:234\u2013240","journal-title":"J Am Coll Cardiol"},{"key":"400_CR3","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/S0022-5223(19)37627-5","volume":"81","author":"A. Chaux","year":"1981","unstructured":"Chaux A, Gray RJ, Matloff JM, Feldman H, Sustaita H et al. An appreciation of the new St. Jude valvular prosthesis. J Thorac Cardiovasc Surg 1981;81:202\u2013211","journal-title":"J Thorac Cardiovasc Surg"},{"key":"400_CR4","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1016\/S0735-1097(84)80087-X","volume":"4","author":"I.P. Panidis","year":"1984","unstructured":"Panidis IP, Ren J-F, Kotler MN, Mintz GS, Mundth ED, Goel IP et al. Clinical and echocardiographic evaluation of the St. Jude cardiac valve prosthesis: follow-up of 126 patients. J Am Coll Cardiol 1984;4:454\u2013462","journal-title":"J Am Coll Cardiol"},{"key":"400_CR5","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/0002-9149(82)90033-9","volume":"49","author":"H.J. Feldman","year":"1982","unstructured":"Feldman HJ, Gray RJ, Chaux A, Halpern SW, Kraus R, Allen HN. Noninvasive in vivo and in vitro study of the St. Jude mitral valve prosthesis: evaluation using two-dimensional and M-mode echocardiography, phonocardiography, and cinefluoroscopy. Am J Cardiol 1982;49:1101\u20131109","journal-title":"Am J Cardiol"},{"key":"400_CR6","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1378\/chest.66.1.44","volume":"66","author":"R.F. Gordon","year":"1974","unstructured":"Gordon RF, Najmi M, Kingsley B, Segal BL, Linhart JW. Spectro-analytic evaluation of aortic prosthetic valves. Chest 1974;66:44\u201349","journal-title":"Chest"},{"key":"400_CR7","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1620\/tjem.123.77","volume":"123","author":"Y. Kagawa","year":"1977","unstructured":"Kagawa Y, Nitta S, Satoh N, Saji K, Shibota Y, Horiuchi T et al. Sound spectroanalytic diagnosis of malfunctioning prosthetic heart valve. Tohoku J Exp Med 1977;123:77\u201389","journal-title":"Tohoku J Exp Med"},{"key":"400_CR8","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/S0022-5223(19)37880-8","volume":"79","author":"Y. Kagawa","year":"1980","unstructured":"Kagawa Y, Sato N, Nitta S, Hongo T, Tanaka M, Mohri H et al. Real-time sound spectroanalysis for diagnosis of malfunctioning prosthetic valves. J Thorac Cardiovasc Surg 1980;79:671\u2013679","journal-title":"J Thorac Cardiovasc Surg"},{"key":"400_CR9","first-page":"831","volume":"34","author":"N. Sato","year":"1988","unstructured":"Sato N, Mohri H, Kagawa Y, Horiuchi T, Tanaka M, Nitta S. Real-time sound spectral analysis for diagnosis of thrombosed prosthetic valves. ASAIO Trans 1988;34:831\u2013834","journal-title":"ASAIO Trans"},{"key":"400_CR10","doi-asserted-by":"crossref","first-page":"271","DOI":"10.3349\/ymj.1994.35.3.271","volume":"35","author":"S.H. Kim","year":"1994","unstructured":"Kim SH, Chang BC, Tack G, Huh JM, Kang MS, Cho BK et al. In vitro sound spectral analysis of prosthetic heart valves by mock circulatory system. Yonsei Med J 1994;35:271\u2013278","journal-title":"Yonsei Med J"},{"key":"400_CR11","first-page":"736","volume":"11","author":"P. Johansen","year":"2002","unstructured":"Johansen P, Lomholt M, Nygaard H. Spectral characteristics of mechanical heart valve closing sounds. J Heart Valve Dis 2002;11:736\u2013744","journal-title":"J Heart Valve Dis"},{"key":"400_CR12","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1016\/S0002-8703(05)80304-7","volume":"119","author":"R.L. Donnerstein","year":"1990","unstructured":"Donnerstein RL, Allen HD. Asynchronous leaflet closure in the normally functioning bileaflet mechanical valve. Am Heart J 1990;119:694\u2013697","journal-title":"Am Heart J"},{"key":"400_CR13","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1016\/S0022-5223(19)36624-3","volume":"101","author":"R.L. Donnerstein","year":"1991","unstructured":"Donnerstein RL, Scott WA, Vasu A, Copeland JG. Acoustic analysis of the closing sounds of bileaflet prosthetic valves in a sheep model. J Thorac Cardiovasc Surg 1991;101:1060\u20131068","journal-title":"J Thorac Cardiovasc Surg"},{"key":"400_CR14","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1007\/s10047-005-0319-7","volume":"9","author":"H. Sugiki","year":"2006","unstructured":"Sugiki H, Shiiya N, Murashita T, Yasuda K. Bileaflet mechanical valve sound analysis with continuous wavelet transform. J Artif Organs 2006;9:42\u201349","journal-title":"J Artif Organs"},{"key":"400_CR15","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s10047-006-0364-x","volume":"10","author":"H. Sugiki","year":"2007","unstructured":"Sugiki H, Shiiya N, Murashita T, Kunihara T, Matsuzaki K, Kubota T et al. Wavelet analysis of bileaflet mechanical valve sounds. J Artif Organs 2007;10:16\u201321","journal-title":"J Artif Organs"},{"key":"400_CR16","first-page":"42","volume-title":"Includes MEM software on CD-ROM","author":"Y. Ishikawa","year":"2000","unstructured":"Ishikawa Y. Wavelet analysis for clinical medicine (in Japanese). Includes MEM software on CD-ROM. Tokyo: Igaku-Shuppan, 2000, pp 42\u201376"},{"key":"400_CR17","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/S0022-5223(19)35130-X","volume":"97","author":"W. Klepetko","year":"1989","unstructured":"Klepetko W, Moritz A, Mlczoch J, Schurawitzki H, Domanig E, Wolner E. Leaflet fracture in Edwards-Duromedics bileaflet valves. J Thorac Cardiovasc Surg 1989;97:90\u201394","journal-title":"J Thorac Cardiovasc Surg"},{"key":"400_CR18","first-page":"764","volume":"12","author":"P. Johansen","year":"2003","unstructured":"Johansen P, Hansen SB, Hasenkam M, Nygaard H. Noise levels of closing sounds in vivo are equal for different bileaflet mechanical heart valves. J Heart Valve Dis 2003;12:764\u2013771","journal-title":"J Heart Valve Dis"},{"key":"400_CR19","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.athoracsur.2005.06.080","volume":"81","author":"T.S. Anderson","year":"2006","unstructured":"Anderson TS, Johansen P, Christensen BO, Paulsen PK, Nygaard H, Hasenkam M. Intraoperative and postoperative evaluation of cavitation in mechanical heart valve patients. Ann Thorac Surg 2006;81:34\u201341","journal-title":"Ann Thorac Surg"},{"issue":"suppl1","key":"400_CR20","first-page":"S8","volume":"3","author":"L.A. Garrison","year":"1994","unstructured":"Garrison LA, Lamson TC, Deutsch S, Geselowitz DB, Gaumond RP, Tarebell JM. An in-vitro investigation of prosthetic heart valve cavitation in blood. J Heart Valve Dis 1994;3(suppl 1):S8\u2013S22","journal-title":"J Heart Valve Dis"}],"container-title":["Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-007-0400-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10047-007-0400-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-007-0400-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,4]],"date-time":"2020-05-04T08:53:00Z","timestamp":1588582380000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10047-007-0400-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,4]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2008,4]]}},"alternative-id":["400"],"URL":"https:\/\/doi.org\/10.1007\/s10047-007-0400-5","relation":{},"ISSN":["1434-7229","1619-0904"],"issn-type":[{"value":"1434-7229","type":"print"},{"value":"1619-0904","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,4]]}}}