{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T05:46:32Z","timestamp":1744177592176},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2013,12,31]],"date-time":"2013-12-31T00:00:00Z","timestamp":1388448000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Artif Organs"],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1007\/s10047-013-0747-8","type":"journal-article","created":{"date-parts":[[2013,12,30]],"date-time":"2013-12-30T04:56:44Z","timestamp":1388379404000},"page":"99-102","source":"Crossref","is-referenced-by-count":5,"title":["Clinical experience of more than 2\u00a0months usage of extracorporeal membrane oxygenation (Endumo\u00ae4000) without circuit exchange"],"prefix":"10.1007","volume":"17","author":[{"given":"Kunio","family":"Kusajima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takaya","family":"Hoashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji","family":"Kagisaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kotaro","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Nishigaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruyuki","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hajime","family":"Ichikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,12,31]]},"reference":[{"key":"747_CR1","first-page":"1391","volume":"12","author":"C Chrysostomou","year":"2012","unstructured":"Chrysostomou C, Morell VO, Kuch BA, O\u2019Malley E, Munoz R, Wearden PD. Short- and intermediate-term survival after extracorporeal membrane oxygenation in children with cardiac disease. J Thorac Cardiovasc Surg. 2012;12:1391\u20138.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"747_CR2","doi-asserted-by":"crossref","first-page":"2975","DOI":"10.1161\/CIRCULATIONAHA.110.991505","volume":"25","author":"CS Almond","year":"2011","unstructured":"Almond CS, Singh TP, Gauvreau K, Piercey GE, Fynn-Thompson F, Rycus PT, Bartlett RH, Thiagarajan RR. Extracorporeal membrane oxygenation for bridge to heart transplantation among children in the United States: analysis of data from the organ procurement and transplant network and extracorporeal life support organization registry. Circulation. 2011;25:2975\u201384.","journal-title":"Circulation"},{"key":"747_CR3","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.athoracsur.2006.02.011","volume":"82","author":"VH Thourani","year":"2006","unstructured":"Thourani VH, Kirshbom PM, Kanter KR, Simsic J, Kogon BE, Wagoner S, Dykes F, Fortenberry J, Forbess JM. Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) in pediatric cardiac support. Ann Thorac Surg. 2006;82:138\u201344.","journal-title":"Ann Thorac Surg"},{"key":"747_CR4","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/S0022-3476(96)70252-4","volume":"129","author":"B Urlesberger","year":"1996","unstructured":"Urlesberger B, Zobel G, Zenz W, Kuttnig-Haim M, Maurer U, Reiterer F, Riccabona M, Dacar D, Gallisti S, Leschnik B, Muntean W. Activation of the clotting system during extracorporeal membrane oxygenation in term newborn infants. J Pediatr. 1996;129:264\u20138.","journal-title":"J Pediatr"},{"key":"747_CR5","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1046\/j.1525-1594.1999.06451.x","volume":"23","author":"W Muntean","year":"1999","unstructured":"Muntean W. Coagulation and anticoagulation in extracorporeal membrane oxygenation. Artif Organs. 1999;23:979\u201383.","journal-title":"Artif Organs"},{"key":"747_CR6","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1046\/j.1525-1594.2002.06886_3.x","volume":"26","author":"T Nishinaka","year":"2002","unstructured":"Nishinaka T, Tatsumi E, Taenaka Y, Katagiri N, Ohnishi H, Shioya K, Matsuda T. At least 34\u00a0days of animal continuous perfusion by a newly developed extracorporeal membrane oxygenation system without systemic anticoagulants. Artif Organs. 2002;26:548\u201351.","journal-title":"Artif Organs"},{"key":"747_CR7","doi-asserted-by":"crossref","unstructured":"Hoashi T, Kagisaki K, Yamashita K, Tatsumi E, Nishigaki T, Yoshida K, Hayashi T, Ichikawa H. Early clinical outcomes of new pediatric extra-corporeal life support system (Endumo\u00ae 2000) in neonates and infants. J Artif Organs 2013;16:267\u201372.","DOI":"10.1007\/s10047-013-0713-5"},{"key":"747_CR8","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1164\/rccm.201109-1599OC","volume":"185","author":"T Fuehner","year":"2012","unstructured":"Fuehner T, Kuehn C, Hadem J, Wiesner O, Gottlieb J, Tudorache I, Olsson KM, Greer M, Sommer W, Welte T, Haverich A, Hoeper MM, Warnecke G. Extracorporeal membrane oxygenation in awake patients as bridge to lung transplantation. Am J Respir Crit Care Med. 2012;185:763\u20138.","journal-title":"Am J Respir Crit Care Med"},{"key":"747_CR9","doi-asserted-by":"crossref","first-page":"2173","DOI":"10.1111\/j.1600-6143.2010.03192.x","volume":"10","author":"KM Olsson","year":"2010","unstructured":"Olsson KM, Simon A, Strueber M, Hadem J, Wiesner O, Gottlieb J, Fuehner T, Fischer S, Warnecke G, K\u00fchn C, Haverich A, Welte T, Hoeper MM. Extracorporeal membrane oxygenation in non-intubated patients as bridge to lung transplantation. Am J Transplant. 2010;10:2173\u20138.","journal-title":"Am J Transplant"},{"key":"747_CR10","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1111\/j.1525-1594.1995.tb02391.x","volume":"19","author":"N Mender","year":"1995","unstructured":"Mender N, Podechtl F, Feil G, Hiltmann P, Sebending F. Seal-less centrifugal blood pump with magnetically suspended rotor: rot-a-flot. Artif Organs. 1995;19:620\u20134.","journal-title":"Artif Organs"}],"container-title":["Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-013-0747-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10047-013-0747-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-013-0747-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T08:02:19Z","timestamp":1559116939000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10047-013-0747-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12,31]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,3]]}},"alternative-id":["747"],"URL":"https:\/\/doi.org\/10.1007\/s10047-013-0747-8","relation":{},"ISSN":["1434-7229","1619-0904"],"issn-type":[{"value":"1434-7229","type":"print"},{"value":"1619-0904","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,12,31]]}}}