{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T05:46:48Z","timestamp":1778824008154,"version":"3.51.4"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2018,2,20]],"date-time":"2018-02-20T00:00:00Z","timestamp":1519084800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"JSPS KAKENHI","award":["JP17K16602"],"award-info":[{"award-number":["JP17K16602"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Artif Organs"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1007\/s10047-018-1027-4","type":"journal-article","created":{"date-parts":[[2018,2,20]],"date-time":"2018-02-20T12:59:14Z","timestamp":1519131554000},"page":"265-270","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Left heart pressures can be the key to know the limitation of left ventricular assist device support against progression of aortic insufficiency"],"prefix":"10.1007","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0517-9893","authenticated-orcid":false,"given":"Kei","family":"Iizuka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Nishinaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noritsugu","family":"Naito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daichi","family":"Akiyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshiaki","family":"Takewa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenji","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eisuke","family":"Tatsumi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,2,20]]},"reference":[{"key":"1027_CR1","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.healun.2014.09.045","volume":"34","author":"J Cowger","year":"2015","unstructured":"Cowger J, Rao V, Massey T, Sun B, May-Newman K, Jorde U, et al. Comprehensive review and suggested strategies for the detection and management of aortic insufficiency in patients with a continuous-flow left ventricular assist device. J Heart Lung Transplant. 2015;34:149\u201357.","journal-title":"J Heart Lung Transplant"},{"key":"1027_CR2","doi-asserted-by":"publisher","first-page":"1172","DOI":"10.1016\/j.healun.2010.05.018","volume":"29","author":"SW Pak","year":"2010","unstructured":"Pak SW, Uriel N, Takayama H, Cappleman S, Song R, Colombo PC, et al. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices. J Heart Lung Transplant. 2010;29:1172\u20136.","journal-title":"J Heart Lung Transplant"},{"key":"1027_CR3","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1253\/circj.CJ-10-1106","volume":"75","author":"M Hatano","year":"2011","unstructured":"Hatano M, Kinugawa K, Shiga T, Kato N, Endo M, Hisagi M, et al. Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device. Circ J. 2011;75:1147\u201355.","journal-title":"Circ J"},{"key":"1027_CR4","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1161\/CIRCHEARTFAILURE.109.917765","volume":"3","author":"J Cowger","year":"2010","unstructured":"Cowger J, Pagani FD, Haft JW, Romano MA, Aaronson KD, Kolias TJ. The development of aortic insufficiency in left ventricular assist device-supported patients. Circ Heart Fail. 2010;3:668\u201374.","journal-title":"Circ Heart Fail"},{"key":"1027_CR5","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1016\/j.athoracsur.2014.05.030","volume":"98","author":"NP Patil","year":"2014","unstructured":"Patil NP, Sabashnikov A, Mohite PN, Garcia D, Weymann A, Zych B, et al. De novo aortic regurgitation after continuous-flow left ventricular assist device implantation. Ann Thorac Surg. 2014;98:850\u20137.","journal-title":"Ann Thorac Surg"},{"key":"1027_CR6","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1007\/s10047-017-0960-y","volume":"20","author":"K Iizuka","year":"2017","unstructured":"Iizuka K, Nishinaka T, Takewa Y, Yamazaki K, Tatsumi E. The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation. J Artif Organs. 2017;20:194\u20139.","journal-title":"J Artif Organs"},{"key":"1027_CR7","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1007\/BF02919636","volume":"50","author":"K Yamazaki","year":"2002","unstructured":"Yamazaki K, Kihara S, Akimoto T, Tagusari O, Kawai A, Umezu M, et al. EVAHEART an implantable centrifugal blood pump for long-term circulatory support. Jpn J Thorac Cardiovasc Surg. 2002;50:461\u20135.","journal-title":"Jpn J Thorac Cardiovasc Surg"},{"key":"1027_CR8","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1007\/s11748-007-0098-6","volume":"55","author":"K Yamazaki","year":"2007","unstructured":"Yamazaki K, Saito S, Kihara S, Tagusari O, Kurosawa H. Completely pulsatile high flow circulatory support with a constant-speed centrifugal blood pump: mechanisms and early clinical observations. Gen Thorac Cardiovasc Surg. 2007;55:158\u201362.","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"1027_CR9","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1038\/bmt.2012.244","volume":"48","author":"Y Kanda","year":"2013","unstructured":"Kanda Y. Investigation of the freely available easy-to-use software \u2018EZR\u2019 for medical statistics. Bone Marrow Transplant. 2013;48:452\u20138.","journal-title":"Bone Marrow Transplant"},{"key":"1027_CR10","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1097\/01.MAT.0000104819.23235.2F","volume":"50","author":"E Tuzun","year":"2004","unstructured":"Tuzun E, Eya K, Keun Chee H, Conger JL, Bruno NK, Frazier OH, et al. Myocardial hemodynamics, physiology, and perfusion with an axial flow left ventricular assist device in the calf. ASAIO J. 2004;50:47\u201353.","journal-title":"ASAIO J"},{"key":"1027_CR11","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1111\/j.1525-1594.2008.00677.x","volume":"33","author":"P Voitl","year":"2009","unstructured":"Voitl P, Vollkron M, Bergmeister H, Wieselthaler G, Schima H. Coronary hemodynamics and myocardial oxygen consumption during support with rotary blood pumps. Artif Organs. 2009;33:77\u201380.","journal-title":"Artif Organs"},{"key":"1027_CR12","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1007\/s10047-016-0929-2","volume":"20","author":"Y Itoda","year":"2017","unstructured":"Itoda Y, Nawata K, Yamauchi H, Kinoshita O, Kimura M, Ono M. Central aortic valve closure successfully treated aortic insufficiency of the patient with Jarvik 2000 continuous flow left ventricular assist device: a case report. J Artif Organs. 2017;20:99\u2013101.","journal-title":"J Artif Organs"}],"container-title":["Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10047-018-1027-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-018-1027-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-018-1027-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,2,19]],"date-time":"2019-02-19T19:39:11Z","timestamp":1550605151000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10047-018-1027-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2,20]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,9]]}},"alternative-id":["1027"],"URL":"https:\/\/doi.org\/10.1007\/s10047-018-1027-4","relation":{},"ISSN":["1434-7229","1619-0904"],"issn-type":[{"value":"1434-7229","type":"print"},{"value":"1619-0904","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2,20]]},"assertion":[{"value":"11 December 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 February 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Kenji Yamazaki has received consulting fees from Sun Medical Technology Research Corporation (Nagano, Japan). Eisuke Tatsumi has received research funding from Sun Medical Technology Research Corporation (Nagano, Japan). The other authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}