{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T22:29:05Z","timestamp":1793831345750,"version":"4.6.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,11,2]],"date-time":"2018-11-02T00:00:00Z","timestamp":1541116800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Artif Organs"],"published-print":{"date-parts":[[2019,6]]},"DOI":"10.1007\/s10047-018-1078-6","type":"journal-article","created":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T22:12:59Z","timestamp":1541110379000},"page":"98-103","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Left ventricular assist device-related infections: does the time of onset matter?"],"prefix":"10.1007","volume":"22","author":[{"given":"Amy L.","family":"Lehnert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda","family":"Hart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara D.","family":"Brouse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard J.","family":"Charnigo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Branam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maya E.","family":"Guglin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,11,2]]},"reference":[{"key":"1078_CR1","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s11908-012-0261-9","volume":"14","author":"D Spelman","year":"2012","unstructured":"Spelman D, Esmore D. Ventricular assist device infections. Curr Infect Dis Rep. 2012;14:359\u201366.","journal-title":"Curr Infect Dis Rep"},{"key":"1078_CR2","doi-asserted-by":"publisher","first-page":"1108","DOI":"10.1086\/428728","volume":"40","author":"D Simon","year":"2005","unstructured":"Simon D, Fischer S, Grossman A, et al. Left ventricular assist device-related infection: treatment and outcome. Clin Infect Dis. 2005;40:1108\u201315.","journal-title":"Clin Infect Dis"},{"key":"1078_CR3","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.1056\/NEJMoa012175","volume":"345","author":"EA Rose","year":"2001","unstructured":"Rose EA, Gelijns AC, Moskowitz AL, et al. Long-term use of a left ventricular assist device for end-stage heart failure. N Eng J Med. 2001;345:1435\u201343.","journal-title":"N Eng J Med"},{"key":"1078_CR4","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.healun.2011.01.717","volume":"30","author":"MM Hannan","year":"2011","unstructured":"Hannan MM, Husain S, Mattner F, et al. Working formulation for the standardization of definitions of infections in patients using ventricular assist devices. J Heart Lung Transpl. 2011;30:375\u201384.","journal-title":"J Heart Lung Transpl"},{"key":"1078_CR5","doi-asserted-by":"publisher","first-page":"1438","DOI":"10.1093\/cid\/cit536","volume":"57","author":"JJ Nienaber","year":"2013","unstructured":"Nienaber JJ, Kusne S, Riaz T, et al. Clinical manifestations and management of left ventricular assist device-associated infections. Clin Infect Dis. 2013;57:1438\u201348.","journal-title":"Clin Infect Dis"},{"key":"1078_CR6","first-page":"2151","volume":"7","author":"A Leuck","year":"2015","unstructured":"Leuck A. Left ventricular assist device driveline infections: recent advances and future goals. J Thorac Dis. 2015;7:2151\u20137.","journal-title":"J Thorac Dis"},{"key":"1078_CR7","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1161\/CIRCULATIONAHA.112.128132","volume":"127","author":"RJ Gordon","year":"2013","unstructured":"Gordon RJ, Weinberg AD, Pagani FD, et al. Prospective, multicenter study of ventricular assist device infections. Circulation. 2013;127:691\u2013702.","journal-title":"Circulation"},{"key":"1078_CR8","doi-asserted-by":"publisher","first-page":"522","DOI":"10.14503\/THIJ-14-4612","volume":"42","author":"EE Donahey","year":"2015","unstructured":"Donahey EE, Polly DM, Vega JD, et al. Multidrug-resistant organism infections in patients with left ventricular assist devices. Tex Heart Inst J. 2015;42:522\u20137.","journal-title":"Tex Heart Inst J"},{"key":"1078_CR9","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1016\/j.healun.2012.05.004","volume":"31","author":"DJ Goldstein","year":"2012","unstructured":"Goldstein DJ, Naftel D, Holman W, et al. Continuous-flow devices and percutaneous site infections: clinical outcomes. J Heart Lung Transpl. 2012;31:1151\u20137.","journal-title":"J Heart Lung Transpl"},{"key":"1078_CR10","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1016\/j.athoracsur.2012.09.011","volume":"95","author":"N Moazami","year":"2013","unstructured":"Moazami N, Milano CA, John R, et al. Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality. Ann Thorac Surg. 2013;95:500\u20135.","journal-title":"Ann Thorac Surg"},{"key":"1078_CR11","doi-asserted-by":"publisher","first-page":":267","DOI":"10.1016\/j.jtcvs.2014.08.054","volume":"149","author":"J Anand","year":"2015","unstructured":"Anand J, Singh SK, Hernandez R, et al. Continuous-flow ventricular assist device exchange is safe and effective in prolonging support time in patients with end-stage heart failure. J Thorac Cardiovasc Surg. 2015;149:267\u2013 75,278.e1.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1078_CR12","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1055\/s-0035-1564449","volume":"63","author":"N Bhatia","year":"2015","unstructured":"Bhatia N, Voelkel AJ, Hussain Z, et al. Safety and feasibility of induction immunosuppression when driveline infection is an indication for cardiac transplantation. Thorac Cardiovasc Surg. 2015;63:675\u201383.","journal-title":"Thorac Cardiovasc Surg"},{"key":"1078_CR13","doi-asserted-by":"publisher","first-page":"28","DOI":"10.14797\/mdcj-11-1-28","volume":"11","author":"BH Trachtenberg","year":"2015","unstructured":"Trachtenberg BH, Cordero-Reyes A, Elias B, Loebe M. A review of infections in patients with left ventricular assist devices: prevention, diagnosis and management. Methodist Debakey Cardiovasc J. 2015;11:28\u201332.","journal-title":"Methodist Debakey Cardiovasc J"},{"key":"1078_CR14","doi-asserted-by":"publisher","first-page":"282","DOI":"10.5301\/ijao.5000590","volume":"40","author":"N Aburjania","year":"2017","unstructured":"Aburjania N, Sherazi S, Tchantchaleishvili V, Alexis JD, Hay CM. Stopping conventional showering decreases Pseudomonas infections in left ventricular assist device patients. Int J Artif Organs. 2017;40:282\u2013285.","journal-title":"Int J Artif Organs"}],"container-title":["Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-018-1078-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10047-018-1078-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-018-1078-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,11,1]],"date-time":"2019-11-01T20:35:34Z","timestamp":1572640534000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10047-018-1078-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,2]]},"references-count":14,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["1078"],"URL":"https:\/\/doi.org\/10.1007\/s10047-018-1078-6","relation":{},"ISSN":["1434-7229","1619-0904"],"issn-type":[{"value":"1434-7229","type":"print"},{"value":"1619-0904","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,2]]},"assertion":[{"value":"12 August 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 October 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 November 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}