{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T12:26:17Z","timestamp":1766492777391,"version":"build-2065373602"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T00:00:00Z","timestamp":1756857600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T00:00:00Z","timestamp":1756857600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Artif Organs"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1007\/s10047-025-01526-7","type":"journal-article","created":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T18:39:15Z","timestamp":1756924755000},"page":"631-635","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Use of shunt-side esCCO monitoring for hemodynamic management during hemodialysis as a novel approach for early detection of hypotension: a report of two cases"],"prefix":"10.1007","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9961-797X","authenticated-orcid":false,"given":"Koji","family":"Nakai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuichi","family":"Hirate","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeyuki","family":"Hiramatsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazue","family":"Kojima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuika","family":"Wada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aiko","family":"Nakai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,3]]},"reference":[{"key":"1526_CR1","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1159\/000508979","volume":"45","author":"H Li","year":"2020","unstructured":"Li H, Xue J, Dai W, Liao X, Zhu P, Zhou Q, et al. Blood pressure variability and outcomes in end-stage renal disease patients on dialysis: a systematic review and meta-analysis. Kidney Blood Press Res. 2020;45:631\u201344.","journal-title":"Kidney Blood Press Res"},{"key":"1526_CR2","doi-asserted-by":"publisher","DOI":"10.1080\/08037051.2025.2469260","author":"E Habas","year":"2025","unstructured":"Habas E, Rayani A, Habas A, Farfar K, Habas E, Alarbi K, et al. Intradialytic hypotension pathophysiology and therapy update: review and update. Blood Press. 2025. https:\/\/doi.org\/10.1080\/08037051.2025.2469260.","journal-title":"Blood Press"},{"key":"1526_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrc.2024.154944","volume":"85","author":"JH Kim","year":"2025","unstructured":"Kim JH, Yoon J, Kim JE, Jo S, Lee Y, Kim JW, et al. Cumulative impact of hypotension during intermittent hemodialysis on kidney recovery in critically ill patients with AKI-D. J Crit Care. 2025;85:154944.","journal-title":"J Crit Care"},{"key":"1526_CR4","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1159\/000479250","volume":"191","author":"M Cozzolino","year":"2017","unstructured":"Cozzolino M, Galassi A, Pivari F, Ciceri P, Conte F. The cardiovascular burden in end-stage renal disease. Contrib Nephrol. 2017;191:44\u201357.","journal-title":"Contrib Nephrol"},{"key":"1526_CR5","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1186\/s12882-019-1542-4","volume":"20","author":"K Doenyas-Barak","year":"2019","unstructured":"Doenyas-Barak K, de Abreu MH, Borges LE, Tavares Filho HA, Yunlin F, Yurong Z, et al. Non-invasive hemodynamic profiling of patients undergoing hemodialysis\u2014a multicenter observational cohort study. BMC Nephrol. 2019;20:347.","journal-title":"BMC Nephrol"},{"key":"1526_CR6","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1186\/s12871-023-02244-4","volume":"23","author":"Y Uemura","year":"2023","unstructured":"Uemura Y, Kinoshita M, Sakai Y, Tanaka K. Hemodynamic impact of ephedrine on hypotension during general anesthesia: a prospective cohort study on middle-aged and older patients. BMC Anesthesiol. 2023;23:283.","journal-title":"BMC Anesthesiol"},{"key":"1526_CR7","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1159\/000534601","volume":"53","author":"S Spano","year":"2024","unstructured":"Spano S, Maeda A, Lam J, Chaba A, Phongphithakchai A, Pattamin N, et al. A pilot and feasibility study of continuous cardiac output and blood pressure monitoring during intermittent hemodialysis. Blood Purif. 2024;53:928\u201336.","journal-title":"Blood Purif"},{"key":"1526_CR8","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1111\/1744-9987.14193","volume":"29","author":"K Nakai","year":"2025","unstructured":"Nakai K, Hirate Y, Nakajima T, Doi A, Hiramatsu T, Higaki T, et al. Reliability and benefit of estimated continuous cardiac output measurement using shunt-side SpO2 monitor in hemodialysis. Ther Apher Dial. 2025;29:61\u20139.","journal-title":"Ther Apher Dial"},{"key":"1526_CR9","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1016\/j.bja.2021.06.048","volume":"127","author":"L Meng","year":"2021","unstructured":"Meng L. Heterogeneous impact of hypotension on organ perfusion and outcomes: a narrative review. Br J Anaesth. 2021;127:845\u201361.","journal-title":"Br J Anaesth"},{"key":"1526_CR10","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1159\/000534601","volume":"53","author":"S Spano","year":"2024","unstructured":"Spano S, Maeda A, Lam J, Chaba A, See E, Mount P, et al. Cardiac output changes during renal replacement therapy: a scoping review. Blood Purif. 2024;53:151\u201361.","journal-title":"Blood Purif"},{"key":"1526_CR11","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1007\/s00540-023-03176-6","volume":"37","author":"M Takakura","year":"2023","unstructured":"Takakura M, Fujii T, Taniguchi T, Suzuki S, Nishiwaki K. Accuracy of a non-invasive estimated continuous cardiac output measurement under different respiratory conditions: a prospective observational study. J Anesth. 2023;37:394\u2013400.","journal-title":"J Anesth"},{"key":"1526_CR12","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s12630-013-0055-z","volume":"61","author":"MO Fischer","year":"2014","unstructured":"Fischer MO, Balaire X, Le Mauff de Kergal C, Boisselier C, G\u00e9rard JL, Hanouz JL, et al. The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography. Can J Anesth. 2014;61:19\u201326.","journal-title":"Can J Anesth"},{"key":"1526_CR13","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/s10877-016-9853-5","volume":"31","author":"AA Smetkin","year":"2017","unstructured":"Smetkin AA, Hussain A, Fot EV, Zakharov VI, Izotova NN, Yudina AS, et al. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution. J Clin Monit Comput. 2017;31:361\u201370.","journal-title":"J Clin Monit Comput"},{"key":"1526_CR14","doi-asserted-by":"publisher","first-page":"1857","DOI":"10.1038\/s41598-020-58910-x","volume":"10","author":"E Schneck","year":"2020","unstructured":"Schneck E, Drubel P, Sch\u00fcrg R, Markmann M, Kohl T, Henrich M, et al. Evaluation of pulse wave transit time analysis for non-invasive cardiac output quantification in pregnant patients. Sci Rep. 2020;10:1857.","journal-title":"Sci Rep"},{"key":"1526_CR15","doi-asserted-by":"publisher","first-page":"2009","DOI":"10.3233\/THC-220520","volume":"31","author":"SC Lee","year":"2023","unstructured":"Lee SC, Lee GH, Lee TY, Park SY. Comparison of parameter types for the calibration of noninvasive continuous cardiac output monitoring of patients undergoing lumbar spinal surgery in the prone position. Technol Health Care. 2023;31:2009\u201319.","journal-title":"Technol Health Care"},{"key":"1526_CR16","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1007\/s10877-019-00330-y","volume":"34","author":"M Sanders","year":"2020","unstructured":"Sanders M, Servaas S, Slagt C. Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis. J Clin Monit Comput. 2020;34:433\u201360.","journal-title":"J Clin Monit Comput"},{"key":"1526_CR17","first-page":"340","volume":"28","author":"VK Arya","year":"2022","unstructured":"Arya VK, Al-Moustadi W, Dutta V. Cardiac output monitoring - invasive and noninvasive. Curr Opin Crit Care. 2022;28:340\u20137.","journal-title":"Curr Opin Crit Care"}],"container-title":["Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-025-01526-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10047-025-01526-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-025-01526-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T05:03:15Z","timestamp":1761195795000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10047-025-01526-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,3]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["1526"],"URL":"https:\/\/doi.org\/10.1007\/s10047-025-01526-7","relation":{},"ISSN":["1434-7229","1619-0904"],"issn-type":[{"type":"print","value":"1434-7229"},{"type":"electronic","value":"1619-0904"}],"subject":[],"published":{"date-parts":[[2025,9,3]]},"assertion":[{"value":"2 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the ethics review committees of Chubu University (approval number 20200084; dated February 26, 2021) and Nagoya Ekisaikai Hospital (approval number 2020\u2013076; dated April 7, 2021). Written informed consent was obtained from all patients.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}