{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T16:11:15Z","timestamp":1789056675254,"version":"build-2803163510"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Artif Organs"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1007\/s10047-026-01563-w","type":"journal-article","created":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T12:51:19Z","timestamp":1781355079000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Severe right heart failure following HeartMate 3 implantation in a small pediatric patient: a case report"],"prefix":"10.1007","volume":"29","author":[{"given":"Ryoichi","family":"Kondo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shogo","family":"Shimada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tetsuri","family":"Takei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenta","family":"Matsui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiaki","family":"Mishima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaomi","family":"Fukuzumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomo","family":"Yoshizumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshimi","family":"Tamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuta","family":"Murai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Otani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaho","family":"Aoi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kagami","family":"Miyaji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,13]]},"reference":[{"key":"1563_CR1","doi-asserted-by":"publisher","first-page":"1114","DOI":"10.1016\/j.healun.2022.04.007","volume":"41","author":"M Essandoh","year":"2022","unstructured":"Essandoh M, et al. Pulmonary artery pulsatility index as a predictor of right ventricular failure in left ventricular assist device recipients: a systematic review. J Heart Lung Transplant. 2022;41:1114\u201323.","journal-title":"J Heart Lung Transplant"},{"key":"1563_CR2","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.healun.2015.06.009","volume":"35","author":"G Kang","year":"2016","unstructured":"Kang G, et al. Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation. J Heart Lung Transplant. 2016;35:67\u201373.","journal-title":"J Heart Lung Transplant"},{"key":"1563_CR3","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1161\/CIRCULATIONAHA.117.030543","volume":"137","author":"OII Soliman","year":"2018","unstructured":"Soliman OII, et al. Derivation and validation of a novel right-sided heart failure model after implantation of continuous flow left ventricular assist devices: the EUROMACS (European registry for patients with mechanical circulatory support) right-sided heart failure risk score. Circulation. 2018;137:891\u2013906.","journal-title":"Circulation"},{"key":"1563_CR4","first-page":"S52","volume":"6","author":"M Argiriou","year":"2014","unstructured":"Argiriou M, et al. Right heart failure post left ventricular assist device implantation. J Thorac Dis. 2014;6:S52\u20139.","journal-title":"J Thorac Dis"},{"key":"1563_CR5","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.jtcvs.2009.11.020","volume":"139","author":"RL Kormos","year":"2010","unstructured":"Kormos RL, et al. Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes. J Thorac Cardiovasc Surg. 2010;139:1316\u201324.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1563_CR6","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1016\/j.atssr.2024.04.015","volume":"2","author":"A Furuta","year":"2024","unstructured":"Furuta A, et al. Preoperative computed tomography virtual simulation for HeartMate 3 implantation in small children. Ann Thorac Surg Short Rep. 2024;2:404\u20136.","journal-title":"Ann Thorac Surg Short Rep"},{"key":"1563_CR7","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1093\/icvts\/ivac009","volume":"34","author":"J Van Puyvelde","year":"2022","unstructured":"Van Puyvelde J, et al. Heartmate 3 implantation in small patients: CT-guided chest diameter assessment. Interact Cardiovasc Thorac Surg. 2022;34:939\u201340.","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"1563_CR8","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1016\/j.healun.2023.06.015","volume":"42","author":"MJ O'Connor","year":"2023","unstructured":"O\u2019Connor MJ, et al. Expanding use of the HeartMate 3 ventricular assist device in pediatric and adult patients within the advanced cardiac therapies improving outcomes network (ACTION). J Heart Lung Transplant. 2023;42:1546\u201356.","journal-title":"J Heart Lung Transplant"},{"key":"1563_CR9","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.xjtc.2024.03.015","volume":"30","author":"T Ushijima","year":"2024","unstructured":"Ushijima T, et al. Technical considerations for successful durable left ventricular assist device implantation in a small child. JTCVS Tech. 2024;30:157\u20139.","journal-title":"JTCVS Tech"}],"container-title":["Journal of Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-026-01563-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10047-026-01563-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10047-026-01563-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T16:03:09Z","timestamp":1789056189000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10047-026-01563-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,13]]},"references-count":9,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1563"],"URL":"https:\/\/doi.org\/10.1007\/s10047-026-01563-w","relation":{},"ISSN":["1434-7229","1619-0904"],"issn-type":[{"value":"1434-7229","type":"print"},{"value":"1619-0904","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,13]]},"assertion":[{"value":"26 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethical approval was not required for this single case report according to institutional policy. Written informed consent for publication was obtained from the patient and her legal guardian. Patient confidentiality was strictly maintained.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"33"}}