{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T11:08:22Z","timestamp":1781176102813,"version":"3.54.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2006,8,29]],"date-time":"2006-08-29T00:00:00Z","timestamp":1156809600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Emerg Radiol"],"published-print":{"date-parts":[[2006,10,30]]},"DOI":"10.1007\/s10140-006-0513-9","type":"journal-article","created":{"date-parts":[[2006,8,28]],"date-time":"2006-08-28T04:26:37Z","timestamp":1156739197000},"page":"69-72","source":"Crossref","is-referenced-by-count":36,"title":["Multidetector-row computed tomography diagnosis of small bowel obstruction: can coronal reformations replace axial images?"],"prefix":"10.1007","volume":"13","author":[{"given":"Vahid","family":"Yaghmai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Nikolaidis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nancy A.","family":"Hammond","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bojan","family":"Petrovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard M.","family":"Gore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank H.","family":"Miller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2006,8,29]]},"reference":[{"key":"513_CR1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/BF02616381","volume":"2","author":"RS Suh","year":"1995","unstructured":"Suh RS, Maglinte DDT, Lavonas EJ et al (1995) Emergency abdominal radiography: discrepancies of preliminary and final interpretation and management relevance. Emerg Radiol 2:1\u20134","journal-title":"Emerg Radiol"},{"key":"513_CR2","first-page":"1015","volume-title":"Principles of surgery","author":"DW McFadden","year":"1994","unstructured":"McFadden DW, Zinner MJ (1994) Manifestations of gastrointestinal disease. In: Schwartz SI, Shires GT, Spencer FC (eds) Principles of surgery. McGraw-Hill, New York, pp 1015\u20131042"},{"key":"513_CR3","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1148\/radiology.180.2.2068291","volume":"180","author":"AJ Megibow","year":"1991","unstructured":"Megibow AJ, Balthazar EJ, Cho KC, Medwid SW, Birnbaum BA, Noz ME (1991) Bowel obstruction: evaluation with CT. Radiology 180:313\u2013318","journal-title":"Radiology"},{"key":"513_CR4","doi-asserted-by":"crossref","first-page":"765","DOI":"10.2214\/ajr.158.4.1546591","volume":"158","author":"T Fukuya","year":"1992","unstructured":"Fukuya T, Hawes DR, Lu CC, Chang PJ, Barloon TJ (1992) CT diagnosis of small-bowel obstruction: efficacy in 60 patients. AJR Am J Roentgenol 158:765\u2013769","journal-title":"AJR Am J Roentgenol"},{"key":"513_CR5","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1148\/radiographics.21.2.g01mr05341","volume":"21","author":"A Furukawa","year":"2001","unstructured":"Furukawa A, Yamasaki M, Furuichi K et al (2001) Helical CT in the diagnosis of small bowel obstruction. Radiographics 21:341\u2013355","journal-title":"Radiographics"},{"key":"513_CR6","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.2214\/ajr.167.6.8956576","volume":"167","author":"DT Maglinte","year":"1996","unstructured":"Maglinte DT, Reyes BL, Harmon BH et al (1996) Reliability and role of plain film radiography and CT in the diagnosis of small-bowel obstruction. AJR Am J Roentgenol 167:1451\u20131455","journal-title":"AJR Am J Roentgenol"},{"key":"513_CR7","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1148\/radiology.215.1.r00ap3755","volume":"215","author":"H Hu","year":"2000","unstructured":"Hu H, He HD, Foley WD, Fox SH (2000) Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 215:55\u201362","journal-title":"Radiology"},{"key":"513_CR8","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1148\/radiol.2353040037","volume":"235","author":"TG Flohr","year":"2005","unstructured":"Flohr TG, Schaller S, Stierstorfer K, Bruder H, Ohnesorge BM, Schoepf UJ (2005) Multi-detector row CT systems and image-reconstruction techniques. Radiology 235:756\u2013773","journal-title":"Radiology"},{"key":"513_CR9","doi-asserted-by":"crossref","first-page":"1787","DOI":"10.1148\/radiographics.20.6.g00nv071787","volume":"20","author":"J Rydberg","year":"2000","unstructured":"Rydberg J, Buckwalter KA, Caldemeyer KS et al (2000) Multisection CT: scanning techniques and clinical applications. Radiographics 20:1787\u20131806","journal-title":"Radiographics"},{"key":"513_CR10","doi-asserted-by":"crossref","first-page":"993","DOI":"10.2214\/ajr.174.4.1740993","volume":"174","author":"EM Caoili","year":"2000","unstructured":"Caoili EM, Paulson EK (2000) CT of small-bowel obstruction: another perspective using multiplanar reformations. AJR Am J Roentgenol 174:993\u2013998","journal-title":"AJR Am J Roentgenol"},{"key":"513_CR11","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1046\/j.1365-2168.1998.00813.x","volume":"85","author":"V Donckier","year":"1998","unstructured":"Donckier V, Closset J, Van Gransbeke D et al (1998) Contribution of computer tomography to decision making in the management of adhesive small bowel obstruction. Br J Surg 85:1071\u20131074","journal-title":"Br J Surg"},{"key":"513_CR12","doi-asserted-by":"crossref","first-page":"899","DOI":"10.2214\/ajr.183.4.1830899","volume":"183","author":"EK Paulson","year":"2004","unstructured":"Paulson EK, Jaffe TA, Thomas J, Harris JP, Nelson RC (2004) MDCT of patients with acute abdominal pain: a new perspective using coronal reformations from submillimeter isotropic voxels. AJR Am J Roentgenol 183:899\u2013906","journal-title":"AJR Am J Roentgenol"},{"key":"513_CR13","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0720-048X(00)00270-9","volume":"36","author":"GD Rubin","year":"2000","unstructured":"Rubin GD (2000) Data explosion: the challenge of multidetector-row CT. Eur J Radiol 36:74\u201380","journal-title":"Eur J Radiol"},{"key":"513_CR14","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1148\/radiol.2342032017","volume":"234","author":"AJ Sherbondy","year":"2005","unstructured":"Sherbondy AJ, Holmlund D, Rubin GD, Schraedley PK, Winograd T, Napel S (2005) Alternative input devices for efficient navigation of large CT angiography data sets. Radiology 234:391\u2013398","journal-title":"Radiology"},{"key":"513_CR15","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1007\/s00330-004-2546-3","volume":"15","author":"S Schmidt","year":"2005","unstructured":"Schmidt S, Chevallier P, Chalaron M et al (2005) Multidetector CT enteroclysis: comparison of the reading performance for axial and coronal views. Eur Radiol 15:238\u2013246","journal-title":"Eur Radiol"}],"container-title":["Emergency Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-006-0513-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10140-006-0513-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-006-0513-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T06:22:10Z","timestamp":1559110930000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10140-006-0513-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,8,29]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2006,10,30]]}},"alternative-id":["513"],"URL":"https:\/\/doi.org\/10.1007\/s10140-006-0513-9","relation":{},"ISSN":["1070-3004","1438-1435"],"issn-type":[{"value":"1070-3004","type":"print"},{"value":"1438-1435","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,8,29]]}}}