{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T10:24:29Z","timestamp":1773829469827,"version":"3.50.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2013,7,3]],"date-time":"2013-07-03T00:00:00Z","timestamp":1372809600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Emerg Radiol"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1007\/s10140-013-1141-9","type":"journal-article","created":{"date-parts":[[2013,7,2]],"date-time":"2013-07-02T10:17:25Z","timestamp":1372760245000},"page":"475-483","source":"Crossref","is-referenced-by-count":29,"title":["Dual energy CT in patients with acute abdomen; is it possible for virtual non-enhanced images to replace true non-enhanced images?"],"prefix":"10.1007","volume":"20","author":[{"given":"A. Lan","family":"Im","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Hwan","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong Ho","family":"Bang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kwon Ha","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sang Hyun","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,7,3]]},"reference":[{"key":"1141_CR1","doi-asserted-by":"crossref","first-page":"2136","DOI":"10.1007\/s00330-002-1569-x","volume":"12","author":"B Marincek","year":"2002","unstructured":"Marincek B (2002) Nontraumatic abdominal emergencies: acute abdominal pain: diagnostic strategies. Eur Radiol 12:2136\u20132150","journal-title":"Eur Radiol"},{"key":"1141_CR2","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1007\/s00330-002-1715-5","volume":"13","author":"MP Rosen","year":"2003","unstructured":"Rosen MP, Siewert B, Sands DZ, Bromberg R, Edlow J, Raptopoulos V (2003) Value of abdominal CT in the emergency department for patients with abdominal pain. Eur Radiol 13:418\u2013424","journal-title":"Eur Radiol"},{"issue":"1","key":"1141_CR3","doi-asserted-by":"crossref","first-page":"S64","DOI":"10.1259\/bjr\/31892755","volume":"77","author":"JG Cahir","year":"2004","unstructured":"Cahir JG, Freeman AH, Courtney HM (2004) Multislice CT of the abdomen. Br J Radiol 77(1):S64\u2013S73","journal-title":"Br J Radiol"},{"key":"1141_CR4","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1097\/RLI.0b013e3181379bac","volume":"42","author":"H Scheffel","year":"2007","unstructured":"Scheffel H, Stolzmann P, Frauenfelder T, Schertler T, Desbiolles L, Leschka S et al (2007) Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease. Invest Radiol 42:823\u2013829","journal-title":"Invest Radiol"},{"key":"1141_CR5","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1148\/radiol.2522080557","volume":"252","author":"A Graser","year":"2009","unstructured":"Graser A, Johnson TR, Hecht EM, Becker CR, Leidecker C, Staehler M et al (2009) Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 252:433\u2013440","journal-title":"Radiology"},{"key":"1141_CR6","doi-asserted-by":"crossref","first-page":"2870","DOI":"10.1007\/s00330-010-1874-8","volume":"20","author":"CN Cecco De","year":"2010","unstructured":"De Cecco CN, Buffa V, Fedeli S, Luzietti M, Vallone A, Ruopoli R et al (2010) Dual-energy CT (DECT) of the liver: conventional versus virtual unenhanced images. Eur Radiol 20:2870\u20132875","journal-title":"Eur Radiol"},{"issue":"4","key":"1141_CR7","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1007\/s10140-006-0474-z","volume":"12","author":"ST Lee","year":"2006","unstructured":"Lee ST et al (2006) Prospective comparison of helical CT of the abdomen and pelvis without and with oral contrast in assessing acute abdominal pain in adult Emergency Department patients. Emerg Radiol 12(4):150\u2013157","journal-title":"Emerg Radiol"},{"issue":"1","key":"1141_CR8","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/s10140-008-0743-0","volume":"16","author":"UK Udayasankar","year":"2009","unstructured":"Udayasankar UK et al (2009) Acute abdominal pain: value of non-contrast enhanced ultra-low-dose multi-detector row CT as a substitute for abdominal radiographs. Emerg Radiol 16(1):61\u201370","journal-title":"Emerg Radiol"},{"key":"1141_CR9","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.2214\/ajr.169.6.9393150","volume":"169","author":"W Huda","year":"1997","unstructured":"Huda W (1997) Radiation dosimetry in diagnostic radiology. AJR Am J Roentgenol 169:1487\u20131488","journal-title":"AJR Am J Roentgenol"},{"key":"1141_CR10","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1148\/radiology.210.3.r99mr05645","volume":"210","author":"DE Ware","year":"1999","unstructured":"Ware DE, Huda W, Mergo PJ, Litwiller AL (1999) Radiation effective doses to patients undergoing abdominal CT examinations. Radiology 210:645\u2013650","journal-title":"Radiology"},{"key":"1141_CR11","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1148\/radiol.2303021726","volume":"230","author":"MK Kalra","year":"2004","unstructured":"Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA et al (2004) Strategies for CT radiation dose optimization. Radiology 230:619\u2013628","journal-title":"Radiology"},{"key":"1141_CR12","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1258\/ar.2011.110563","volume":"53","author":"L Borgen","year":"2012","unstructured":"Borgen L, Kalra MK, Laerum F, Hachette IW, Fredriksson CH, Sandborg M et al (2012) Application of adaptive non-linear 2D and 3D postprocessing filters for reduced dose abdominal CT. Acta Radiol 53:335\u2013342","journal-title":"Acta Radiol"},{"key":"1141_CR13","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1016\/j.acra.2009.05.002","volume":"16","author":"LM Ho","year":"2009","unstructured":"Ho LM, Yoshizumi TT, Hurwitz LM, Nelson RC, Marin D, Toncheva G et al (2009) Dual-energy versus single-energy MDCT: measurement of radiation dose using adult abdominal imaging protocols. Acad Radiol 16:1400\u20131407","journal-title":"Acad Radiol"},{"key":"1141_CR14","doi-asserted-by":"crossref","first-page":"1258","DOI":"10.1007\/s11547-010-0583-3","volume":"115","author":"CN Cecco De","year":"2010","unstructured":"De Cecco CN, Buffa V, Fedeli S, Vallone A, Ruopoli R, Luzietti M et al (2010) Preliminary experience with abdominal dual-energy CT (DECT): true versus virtual nonenhanced images of the liver. Radiol Med 115:1258\u20131266","journal-title":"Radiol Med"},{"key":"1141_CR15","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/RLI.0b013e31824c86a3","volume":"47","author":"FG Meinel","year":"2012","unstructured":"Meinel FG, Bischoff B, Zhang QW, Bamberg F, Reiser MF, Johnson TRC (2012) Metal artifact reduction by dual-energy computed tomography using energetic extrapolation a systematically optimized protocol. Investig Radiol 47:406\u2013414","journal-title":"Investig Radiol"},{"key":"1141_CR16","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/RCT.0b013e3181aac7ec","volume":"34","author":"MJ Sangwaiya","year":"2010","unstructured":"Sangwaiya MJ, Kalra MK, Sharma A, Halpern EF, Shepard JA, Digumarthy SR (2010) Dual-energy computed tomographic pulmonary angiography: a pilot study to assess the effect on image quality and diagnostic confidence. J Comput Assist Tomogr 34:46\u201351","journal-title":"J Comput Assist Tomogr"},{"key":"1141_CR17","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1148\/radiol.12110851","volume":"264","author":"S Mangold","year":"2012","unstructured":"Mangold S, Thomas C, Fenchel M, Vuust M, Krauss B, Ketelsen D et al (2012) Virtual nonenhanced dual-energy CT urography with tin-filter technology: determinants of detection of urinary calculi in the renal collecting system. Radiology 264:119\u2013125","journal-title":"Radiology"}],"container-title":["Emergency Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-013-1141-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10140-013-1141-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-013-1141-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,29]],"date-time":"2020-07-29T14:01:48Z","timestamp":1596031308000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10140-013-1141-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,3]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["1141"],"URL":"https:\/\/doi.org\/10.1007\/s10140-013-1141-9","relation":{},"ISSN":["1070-3004","1438-1435"],"issn-type":[{"value":"1070-3004","type":"print"},{"value":"1438-1435","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,3]]}}}