{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T00:06:01Z","timestamp":1791504361477,"version":"4.3.4"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2022,5,25]],"date-time":"2022-05-25T00:00:00Z","timestamp":1653436800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,5,25]],"date-time":"2022-05-25T00:00:00Z","timestamp":1653436800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Emerg Radiol"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1007\/s10140-022-02063-z","type":"journal-article","created":{"date-parts":[[2022,5,25]],"date-time":"2022-05-25T08:03:38Z","timestamp":1653465818000},"page":"809-817","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Efficacy of the scatter correction algorithm in portable chest radiography"],"prefix":"10.1007","volume":"29","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1512-620X","authenticated-orcid":false,"given":"Michael","family":"Lawson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0237-9010","authenticated-orcid":false,"given":"Lijun","family":"Qian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7424-9947","authenticated-orcid":false,"given":"Kenneth K.","family":"Lau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9973-1174","authenticated-orcid":false,"given":"Theo","family":"Lau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3374-8640","authenticated-orcid":false,"given":"David","family":"Massey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8029-9951","authenticated-orcid":false,"given":"Mohamed","family":"Badawy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,25]]},"reference":[{"issue":"5","key":"2063_CR1","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1097\/00003246-199705000-00015","volume":"25","author":"A Brainsky","year":"1997","unstructured":"Brainsky A, Fletcher RH, Glick HA, Lanken PN, Williams SV, Kundel HL (1997) Routine portable chest radiographs in the medical intensive care unit: effects and costs. Crit Care Med 25(5):801\u2013805","journal-title":"Crit Care Med"},{"key":"2063_CR2","doi-asserted-by":"crossref","unstructured":"P. Yeung, J.-A. Pinson, M. Lawson, C. Leong, and M. K. Badawy, \u201cCOVID-19 pandemic and the effect of increased utilisation of mobile X-ray examinations on radiation dose to radiographers,\u201d J. Med. Radiat. Sci., vol. N\/A, no. N\/A, 2022.","DOI":"10.1002\/jmrs.570"},{"issue":"1","key":"2063_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12913-017-2173-8","volume":"17","author":"E Kjelle","year":"2017","unstructured":"Kjelle E, Lysdahl KB (2017) Mobile radiography services in nursing homes: a systematic review of residents\u2019 and societal outcomes. BMC Health Serv Res 17(1):1\u20138","journal-title":"BMC Health Serv Res"},{"key":"2063_CR4","unstructured":"C. A. for D. and T. in Health, \u201cPortable versus fixed X-ray equipment: a review of the clinical effectiveness, cost-effectiveness, and guidelines [Internet],\u201d URL https\/\/www. cadth. ca (\u0434a\u0442a o\u0431pa\u0449e\u043d\u0438\u044f 22.02. 2016)."},{"issue":"3","key":"2063_CR5","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1148\/rg.273065075","volume":"27","author":"M Korner","year":"2007","unstructured":"Korner M, Weber CH, Wirth S, Pfeifer K-J, Reiser MF, Treitl M (2007) Advances in digital radiography: physical principles and system overview. Radiographics 27(3):675\u2013686","journal-title":"Radiographics"},{"key":"2063_CR6","doi-asserted-by":"publisher","first-page":"5217","DOI":"10.1007\/s00330-020-06918-2","volume":"30","author":"G Wu","year":"2020","unstructured":"Wu G, Li X (2020) Mobile X-rays are highly valuable for critically ill COVID patients. Eur Radiol 30:5217\u20135219","journal-title":"Eur Radiol"},{"issue":"3","key":"2063_CR7","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s13246-020-00899-8","volume":"43","author":"Z Brady","year":"2020","unstructured":"Brady Z et al (2020) Technique, radiation safety and image quality for chest X-ray imaging through glass and in mobile settings during the COVID-19 pandemic. Phys Eng Sci Med 43(3):765\u2013779","journal-title":"Phys Eng Sci Med"},{"issue":"2","key":"2063_CR8","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1148\/radiographics.11.2.2028065","volume":"11","author":"GT Barnes","year":"1991","unstructured":"Barnes GT (1991) Contrast and scatter in x-ray imaging. Radiographics 11(2):307\u2013323","journal-title":"Radiographics"},{"issue":"2","key":"2063_CR9","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/0720-048X(91)90099-H","volume":"13","author":"R Miettunen","year":"1991","unstructured":"Miettunen R, Korhola O, Savikurki S (1991) The scatter-to-primary ratio as a function of varying X-ray absorption measured by computed radiography. Eur J Radiol 13(2):156\u2013159","journal-title":"Eur J Radiol"},{"issue":"5","key":"2063_CR10","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1118\/1.595027","volume":"8","author":"LT Niklason","year":"1981","unstructured":"Niklason LT, Sorenson JA, Nelson JA (1981) Scattered radiation in chest radiography. Med Phys 8(5):677\u2013681","journal-title":"Med Phys"},{"key":"2063_CR11","volume-title":"Bildgebende Systeme f\u00fcr die medizinische Diagnostik: R\u00f6ntgendiagnostik und Angiographie, Computertomographie, Nuklearmedizin","author":"H Morneburg","year":"1995","unstructured":"Morneburg H (1995) Bildgebende Systeme f\u00fcr die medizinische Diagnostik: R\u00f6ntgendiagnostik und Angiographie, Computertomographie, Nuklearmedizin. Sonographie, integrierte Informationssysteme. Publicis MCD-Verlag, Magnetresonanztomographie"},{"key":"2063_CR12","doi-asserted-by":"crossref","unstructured":"Aichinger H, Dierker J, Joite-Barfu\u00df S, S\u00e4bel M (2004) \u201cScattered radiation,\u201d in Radiation exposure and image quality in X-ray diagnostic radiology, Springer, pp. 45\u201356","DOI":"10.1007\/978-3-662-09654-3_6"},{"issue":"2","key":"2063_CR13","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1118\/1.596836","volume":"19","author":"U Neitzel","year":"1992","unstructured":"Neitzel U (1992) Grids or air gaps for scatter reduction in digital radiography: a model calculation. Med Phys 19(2):475\u2013481","journal-title":"Med Phys"},{"issue":"3","key":"2063_CR14","first-page":"151","volume":"18","author":"W Akhtar","year":"2008","unstructured":"Akhtar W, Aslam M, Ali A, Mirza K, Ahmad N (2008) Film retakes in digital and conventional radiography. J Coll Physicians Surg Pakistan 18(3):151","journal-title":"J Coll Physicians Surg Pakistan"},{"issue":"940","key":"2063_CR15","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1259\/bjr\/66912494","volume":"79","author":"DW Anderson","year":"2006","unstructured":"Anderson DW (2006) Introduction of grids to mobile ICU radiography in a teaching hospital. Br J Radiol 79(940):315\u2013318","journal-title":"Br J Radiol"},{"issue":"1","key":"2063_CR16","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1148\/radiology.184.1.1609094","volume":"184","author":"PB O\u2019Donovan","year":"1992","unstructured":"O\u2019Donovan PB, Skipper GJ, Litchney JC, Salupo AJ, Bortnick JR (1992) Device for facilitating precise alignment in bedside radiography. Radiology 184(1):284\u2013285","journal-title":"Radiology"},{"issue":"2","key":"2063_CR17","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.ejrad.2009.05.060","volume":"72","author":"M Uffmann","year":"2009","unstructured":"Uffmann M, Schaefer-Prokop C (2009) Digital radiography: the balance between image quality and required radiation dose. Eur J Radiol 72(2):202\u2013208","journal-title":"Eur J Radiol"},{"key":"2063_CR18","doi-asserted-by":"crossref","unstructured":"Martin CJ (2007) \u201cOptimisation in general radiography\u201d. Biomed Imaging Interv J 3(2)","DOI":"10.2349\/biij.3.2.e18"},{"key":"2063_CR19","unstructured":"P. SkyFlow, \u201cGrid-like contrast enhancement for bedside chest radiographs acquired without anti-scatter grid.\u201d"},{"issue":"6","key":"2063_CR20","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1177\/0284185119878348","volume":"61","author":"CG Lisson","year":"2020","unstructured":"Lisson CG et al (2020) Improvement of image quality applying iterative scatter correction for grid-less skeletal radiography in trauma room setting. Acta radiol 61(6):768\u2013775","journal-title":"Acta radiol"},{"issue":"6","key":"2063_CR21","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1177\/0284185118796668","volume":"60","author":"CG Lisson","year":"2019","unstructured":"Lisson CG, Lisson CS, Kleiner S, Regier M, Beer M, Schmidt SA (2019) Iterative scatter correction for grid-less skeletal radiography allows improved image quality equal to an antiscatter grid in adjunct with dose reduction: a visual grading study of 20 body donors. Acta radiol 60(6):735\u2013741","journal-title":"Acta radiol"},{"issue":"1\u20134","key":"2063_CR22","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1093\/rpd\/ncw031","volume":"169","author":"B Renger","year":"2016","unstructured":"Renger B et al (2016) Evaluation of dose reduction potentials of a novel scatter correction software for bedside chest x-ray imaging. Radiat Prot Dosimetry 169(1\u20134):60\u201367","journal-title":"Radiat Prot Dosimetry"},{"issue":"1","key":"2063_CR23","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1093\/rpd\/ncz129","volume":"187","author":"H Precht","year":"2019","unstructured":"Precht H et al (2019) Can scatter correction software replace a grid in DR pelvic examinations? Radiat Prot Dosimetry 187(1):8\u201316","journal-title":"Radiat Prot Dosimetry"},{"key":"2063_CR24","unstructured":"Suzuki R, Goto T, Ogawa H, Amimoto N (2016) \u201cEvaluation of no-grid radiography using the digital scattered x-ray removal processing\u201d"},{"key":"2063_CR25","first-page":"21","volume":"60","author":"T Kawamura","year":"2015","unstructured":"Kawamura T, Naito S, Okano K, Yamada M (2015) Improvement in image quality and workflow of x-ray examinations using a new image processing method, \u2018Virtual Grid Technology.\u2019 Fujifilm Res Dev 60:21\u201327","journal-title":"Fujifilm Res Dev"},{"issue":"6","key":"2063_CR26","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1097\/RLI.0000000000000646","volume":"55","author":"T Gossye","year":"2020","unstructured":"Gossye T, Smeets PV, Achten E, Bacher K (2020) Impact of software parameter settings on image quality of virtual grid processed radiography images: a contrast-detail phantom study. Invest Radiol 55(6):374\u2013380","journal-title":"Invest Radiol"},{"key":"2063_CR27","unstructured":"Go YS, Takayanagi, Hiroshi, Miyata, Keita Goto, T. M. Toma Hirai, Takashi Sasaki, Junya Yamamoto, K. H. Kazuyoshi Nishino, Masaaki Shibata, and and R. T. Yoshinori Ohno, Tetsuya Kobayashi (2017) \u201cDevelopment of scatter correction software,\u201d Kyoto, Japan, 1"},{"issue":"5","key":"2063_CR28","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1001\/jama.290.5.621","volume":"290","author":"HT Keenan","year":"2003","unstructured":"Keenan HT, Runyan DK, Marshall SW, Nocera MA, Merten DF, Sinal SH (2003) A population-based study of inflicted traumatic brain injury in young children. JAMA 290(5):621\u2013626","journal-title":"JAMA"},{"issue":"11","key":"2063_CR29","doi-asserted-by":"publisher","first-page":"2953","DOI":"10.1088\/0031-9155\/51\/11\/018","volume":"51","author":"P Doyle","year":"2006","unstructured":"Doyle P, Martin CJ, Gentle D (2006) Application of contrast-to-noise ratio in optimizing beam quality for digital chest radiography: comparison of experimental measurements and theoretical simulations. Phys Med Biol 51(11):2953","journal-title":"Phys Med Biol"},{"issue":"9","key":"2063_CR30","doi-asserted-by":"publisher","first-page":"e920","DOI":"10.1002\/mp.14227","volume":"47","author":"NB Bevins","year":"2020","unstructured":"Bevins NB, Silosky MS, Badano A, Marsh RM, Flynn MJ, Walz-Flannigan AI (2020) Practical application of AAPM Report 270 in display quality assurance: a report of Task Group 270. Med Phys 47(9):e920\u2013e928","journal-title":"Med Phys"},{"key":"2063_CR31","doi-asserted-by":"crossref","unstructured":"Landis JR, Koch GG (1977) \u201cThe measurement of observer agreement for categorical data\u201d. Biometrics 159\u2013174","DOI":"10.2307\/2529310"},{"issue":"1\u20134","key":"2063_CR32","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1093\/rpd\/ncv432","volume":"169","author":"D Mentrup","year":"2016","unstructured":"Mentrup D, Jockel S, Menser B, Neitzel U (2016) Iterative scatter correction for grid-less bedside chest radiography: performance for a chest phantom. Radiat Prot Dosimetry 169(1\u20134):308\u2013312","journal-title":"Radiat Prot Dosimetry"},{"key":"2063_CR33","doi-asserted-by":"crossref","unstructured":"Ulanowski A, Kaiser JC, Schneider U, Walsh L (2020) \u201cLifetime radiation risk of stochastic effects\u2013prospective evaluation for space flight or medicine\u201d. Ann ICRP 49(1_suppl):200\u2013212","DOI":"10.1177\/0146645320956517"}],"container-title":["Emergency Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-022-02063-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10140-022-02063-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-022-02063-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T12:37:04Z","timestamp":1744202224000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10140-022-02063-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,25]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["2063"],"URL":"https:\/\/doi.org\/10.1007\/s10140-022-02063-z","relation":{},"ISSN":["1070-3004","1438-1435"],"issn-type":[{"value":"1070-3004","type":"print"},{"value":"1438-1435","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,25]]},"assertion":[{"value":"29 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study has been reviewed by the local institutions ethical review board. Low-risk ethics has been granted for this project.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}