{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T20:37:55Z","timestamp":1785875875462,"version":"3.56.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:00:00Z","timestamp":1749081600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T00:00:00Z","timestamp":1749081600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Emerg Radiol"],"DOI":"10.1007\/s10140-025-02349-y","type":"journal-article","created":{"date-parts":[[2025,6,5]],"date-time":"2025-06-05T02:19:35Z","timestamp":1749089975000},"page":"559-568","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Diagnostic yield of an abbreviated MRI protocol in the evaluation of dizziness in the\u00a0emergency\u00a0department, a single institutional experience"],"prefix":"10.1007","volume":"32","author":[{"given":"Faryal","family":"Shareef","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Long","family":"Tu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anish","family":"Neupane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zaid","family":"Siddique","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rudra","family":"Joshi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward","family":"Melnick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Wira","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit","family":"Mahajan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,5]]},"reference":[{"key":"2349_CR1","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1111\/acem.14630","volume":"30","author":"VP Shah","year":"2023","unstructured":"Shah VP, Oliveira JESL, Farah W et al (2023) Diagnostic accuracy of the physical exam in emergency department patients with acute vertigo or dizziness: a systematic review and meta-analysis for GRACE-3. Acad Emerg Med 30:552\u2013578","journal-title":"Acad Emerg Med"},{"key":"2349_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10140-021-01947-w","volume":"29","author":"LH Tu","year":"2022","unstructured":"Tu LH, Venkatesh AK, Malhotra A et al (2022) Scenarios to improve CT head utilization in the emergency department delineated by critical results reporting. Emerg Radiol 29:1\u20138","journal-title":"Emerg Radiol"},{"key":"2349_CR3","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1111\/acem.14561","volume":"30","author":"VP Shah","year":"2023","unstructured":"Shah VP, Oliveira JESL, Farah W et al (2023) Diagnostic accuracy of neuroimaging in emergency department patients with acute vertigo or dizziness: a systematic review and meta-analysis for the guidelines for reasonable and appropriate care in the emergency department. Acad Emerg Med 30:517\u2013530","journal-title":"Acad Emerg Med"},{"issue":"1","key":"2349_CR4","doi-asserted-by":"publisher","first-page":"6114","DOI":"10.1038\/s41598-021-85725-1","volume":"11","author":"JS Kim","year":"2021","unstructured":"Kim JS, Bae HJ, Kim M et al (2021) Stroke prediction in patients presenting with isolated dizziness in the emergency department. Sci Rep 11(1):6114","journal-title":"Sci Rep"},{"issue":"3","key":"2349_CR5","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1212\/WNL.0000000000004120","volume":"89","author":"BL Edlow","year":"2017","unstructured":"Edlow BL, Hurwitz S, Edlow JA (2017) Diagnosis of DWI-negative acute ischemic stroke: a meta-analysis. Neurology 89(3):256\u2013262","journal-title":"Neurology"},{"issue":"3","key":"2349_CR6","first-page":"560","volume":"26","author":"H Nakamura","year":"2005","unstructured":"Nakamura H, Yamada K, Kizu O et al (2005) Effect of thin-section diffusion-weighted MR imaging on stroke diagnosis. AJNR Am J Neuroradiol 26(3):560\u2013565","journal-title":"AJNR Am J Neuroradiol"},{"issue":"5","key":"2349_CR7","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1111\/1754-9485.12490","volume":"60","author":"T Entwisle","year":"2016","unstructured":"Entwisle T, Perchyonok Y, Fitt G (2016) Thin section magnetic resonance diffusion-weighted imaging in the detection of acute infratentorial stroke. J Med Imaging Radiat Oncol 60(5):616\u2013623","journal-title":"J Med Imaging Radiat Oncol"},{"issue":"5","key":"2349_CR8","doi-asserted-by":"publisher","first-page":"1843","DOI":"10.1161\/STROKEAHA.120.032457","volume":"52","author":"P Steffen","year":"2021","unstructured":"Steffen P, Beyer LS, McDonough R et al (2021) Improved detectability of brain stem ischemia by combining axial and coronal diffusion-weighted imaging. Stroke 52(5):1843\u20131846","journal-title":"Stroke"},{"key":"2349_CR9","doi-asserted-by":"publisher","first-page":"2484","DOI":"10.1161\/01.STR.0000240329.48263.0d","volume":"37","author":"KA Kerber","year":"2006","unstructured":"Kerber KA, Brown DL, Lisabeth LD, Smith MA, Morgenstern LB (2006) Stroke among patients with dizziness, vertigo, and imbalance in the emergency department: a population-based study. Stroke 37:2484\u20132487","journal-title":"Stroke"},{"key":"2349_CR10","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1016\/j.mayocp.2012.05.023","volume":"87","author":"BB Navi","year":"2012","unstructured":"Navi BB, Kamel H, Shah MP et al (2012) Rate and predictors of serious neurologic causes of dizziness in the emergency department. Mayo Clin Proc 87:1080\u20131088","journal-title":"Mayo Clin Proc"},{"key":"2349_CR11","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1161\/STROKEAHA.114.007087","volume":"46","author":"K Grewal","year":"2015","unstructured":"Grewal K, Austin PC, Kapral MK, Lu H, Atzema CL (2015) Missed strokes using computed tomography imaging in patients with vertigo: population-based cohort study. Stroke 46:108\u2013113","journal-title":"Stroke"},{"issue":"2","key":"2349_CR12","doi-asserted-by":"publisher","first-page":"162","DOI":"10.5152\/iao.2014.209","volume":"10","author":"MK Park","year":"2014","unstructured":"Park MK, Kim JS, Seo DW et al (2014) The usefulness of magnetic resonance imaging for acute isolated vertigo patients in the emergency department. J Int Adv Otol 10(2):162","journal-title":"J Int Adv Otol"},{"key":"2349_CR13","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/S0140-6736(07)60151-2","volume":"369","author":"JA Chalela","year":"2007","unstructured":"Chalela JA, Kidwell CS, Nentwich LM et al (2007) Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke: a prospective comparison. Lancet 369:293\u2013298","journal-title":"Lancet"},{"key":"2349_CR14","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1177\/1971400920988665","volume":"34","author":"A Guarnizo","year":"2021","unstructured":"Guarnizo A, Farah K, Lelli DA et al (2021) Limited usefulness of routine head and neck CT angiogram in the imaging assessment of dizziness in the emergency department. Neuroradiol J 34:335\u2013340","journal-title":"Neuroradiol J"},{"key":"2349_CR15","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1111\/acem.14728","volume":"30","author":"JA Edlow","year":"2023","unstructured":"Edlow JA, Carpenter C, Akhter M et al (2023) Guidelines for reasonable and appropriate care in the emergency department 3 (GRACE-3): acute dizziness and vertigo in the emergency department. Acad Emerg Med 30:442\u2013486. https:\/\/doi.org\/10.1111\/acem.14728","journal-title":"Acad Emerg Med"},{"issue":"2","key":"2349_CR16","doi-asserted-by":"publisher","first-page":"e2330060","DOI":"10.2214\/AJR.23.30060","volume":"222","author":"LH Tu","year":"2024","unstructured":"Tu LH, Melnick E, Venkatesh AK et al (2024) Cost-effectiveness of CT, CTA, MRI, and specialized MRI for evaluation of patients presenting to the emergency department with dizziness. AJR Am J Roentgenol 222(2):e2330060","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"2349_CR17","doi-asserted-by":"publisher","first-page":"836","DOI":"10.2214\/AJR.23.29617","volume":"221","author":"LH Tu","year":"2023","unstructured":"Tu LH, Navaratnam D, Melnick ER et al (2023) CT with CTA versus MRI in patients presenting to the emergency department with dizziness: analysis using propensity score matching. AJR Am J Roentgenol 221(6):836\u2013845","journal-title":"AJR Am J Roentgenol"},{"key":"2349_CR18","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.clinimag.2021.12.001","volume":"82","author":"LH Tu","year":"2022","unstructured":"Tu LH, Mahajan A, Minja FJ et al (2022) Pilot MRI-based strategies to improve the detection of stroke in patients with dizziness\/vertigo. Clin Imaging 82:234\u2013236","journal-title":"Clin Imaging"},{"issue":"8","key":"2349_CR19","doi-asserted-by":"publisher","first-page":"1480","DOI":"10.3174\/ajnr.A5210","volume":"38","author":"M Buller","year":"2017","unstructured":"Buller M, Karis JP (2017) Introduction of a dedicated emergency department MR imaging scanner at the Barrow Neurological Institute. AJNR Am J Neuroradiol 38(8):1480\u20131485. https:\/\/doi.org\/10.3174\/ajnr.A5210","journal-title":"AJNR Am J Neuroradiol"},{"issue":"1\u20132","key":"2349_CR20","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.jns.2009.11.015","volume":"290","author":"E Anagnostou","year":"2010","unstructured":"Anagnostou E, Spengos K, Vassilopoulou S et al (2010) Incidence of rotational vertigo in supratentorial stroke: a prospective analysis of 112 consecutive patients. J Neurol Sci 290(1\u20132):33\u201336","journal-title":"J Neurol Sci"},{"key":"2349_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00415-023-11566-9","volume":"270","author":"JY Park","year":"2023","unstructured":"Park JY, Choi JH, Kwon JH et al (2023) Incidence, characteristics, and neuroanatomical substrates of vestibular symptoms in supratentorial stroke. J Neurol 270:1\u201310","journal-title":"J Neurol"},{"key":"2349_CR22","doi-asserted-by":"crossref","unstructured":"Newman-Toker DE, Peterson SM, Badihian S, et al. (2022) Diagnostic errors in the emergency department: a systematic review. Rockville, MD: Agency for Healthcare Research and Quality (US)","DOI":"10.23970\/AHRQEPCCER258"}],"container-title":["Emergency Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-025-02349-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10140-025-02349-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-025-02349-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T17:53:52Z","timestamp":1757181232000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10140-025-02349-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,5]]},"references-count":22,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,8]]}},"alternative-id":["2349"],"URL":"https:\/\/doi.org\/10.1007\/s10140-025-02349-y","relation":{},"ISSN":["1438-1435"],"issn-type":[{"value":"1438-1435","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,5]]},"assertion":[{"value":"18 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Yale University Institutional Review Board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was waived by the Yale University Institutional Review Board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Amit Mahajan reports a relationship with Reveal pharmaceutical that includes: consulting or advisory. Amit Mahajan reports a relationship with Thornhill Medical that includes: consulting or advisory. Edward Melnick reports a relationship with American Medical Association that includes: funding grants. Edward Melnick reports a relationship with National Institute on Drug Abuse that includes: funding grants. Edward Melnick reports a relationship with Agency for Healthcare Research and Quality, and the Centers for Medicaid and Medicare Services that includes: funding grants. Long Tu has patent with royalties paid to to\"Search Pattern: A Systematic Approach to Diagnostic Imaging\"(2020),\"A Brief Guide to the Neuroradiology Fellowship\"(2021), and\"How to be a More Efficient Radiologist: A Guide to Practice, Reporting, and Workflow Optimization\"(2023). If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}