{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T23:53:39Z","timestamp":1790985219262,"version":"4.1.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Emerg Radiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Computed tomography (CT) is state of the art imaging modality in patients after severe trauma. A double-bolus contrast media protocol can be used to combine both arterial and parenchymal contrast in one scan. In case of lower extremity trauma, the CT scans can be extended to include the legs in order to rule out vascular pathologies. Virtual monoenergetic (VME) images derived from a Photon-Counting detector CT (PCDCT) proved to be helpful in vascular diagnostics and could therefore also add information in these extended trauma scans. Aim of this study was to determine the VME reconstructions with sufficient vascular contrast (&gt;\u2009200 Hounsfield Units) and to examine, which VME level has best specificity and sensitivity as well as best subjective vascular visibility.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In a retrospective analysis, we identified 34 patients undergoing extended whole-body trauma scans including lower extremities on a PCDCT with pathologies of the lower extremity arteries (extravasation, dissection etc.) and paired them with 34 patients without vascular pathologies. We measured CT values and noise of six vascular segments on energy levels 40 to 190\u00a0keV and calculated signal to noise (SNR) and contrast to noise (CNR) ratio. Subjective ratings for vascular visibility were performed on a five point Likert scale and two readers analyzed the images for vascular lesions across four energy levels (40, 70, 90 and 110\u00a0keV).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>CT attenuation was measured above 200 HU below 88\u00a0keV in the common femoral artery, below 86\u00a0keV in the superficial femoral artery and below 85\u00a0keV in the popliteal artery. For the tibial arteries, we found higher CT values above 200 HU at the energy levels below 87\u00a0keV. Noise was highest at 40\u00a0keV for all energy levels, SNR and CNR for common femoral artery was highest at 40\u00a0keV.<\/jats:p>\n                    <jats:p>Sensitivity peaked at 40 keV (78.4%) and showed decreasing values for higher energy levels. Specificity increased with higher keV levels up to 91.7%. 40 keV showed the highest sum of Likert ratings regarding vascular visibility.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>PCDCT derived VME reconstructions below 86 keV showed sufficient vascular contrast in extended whole-body trauma scans after double-bolus contrast media administration. Smaller vessel depiction can be hampered by increased noise on lower energy levels resulting in decreased image parameters.<\/jats:p>\n                    <jats:p>Lower energy levels have the potential to improve the detection of vascular pathologies, such as bleeding and vascular occlusions.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10140-026-02502-1","type":"journal-article","created":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T02:22:29Z","timestamp":1781576549000},"page":"981-990","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Impact of virtual monoenergetic images on the assessability of lower extremity arteries in (Poly-) trauma photon-counting detector CT"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2088-0167","authenticated-orcid":false,"given":"Daniel","family":"Dillinger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Bauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanns L.","family":"Kaatsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Achim","family":"Neufang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Achim","family":"Hagen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Waldeck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Overhoff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,16]]},"reference":[{"issue":"6","key":"2502_CR1","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1055\/a-2276-6357","volume":"162","author":"D Benning","year":"2024","unstructured":"Benning D, Hackenberg L, Pavlu F, Weber W, Franke A, Kollig E et al (2024) New Recommendations for the Care of Severely Injured Patients: Revision of the S3 Guideline on Treatment of Polytrauma\/Severe Injuries. Z Orthop Unfall 162(6):630\u2013637","journal-title":"Z Orthop Unfall"},{"issue":"1","key":"2502_CR2","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1007\/s00068-025-02852-4","volume":"51","author":"CR Valcarcel","year":"2025","unstructured":"Valcarcel CR, Bieler D, Bass GA, Gaarder C, Hildebrand F, Group EPC (2025) ESTES recommendations for the treatment of polytrauma-a European consensus based on the German S3 guidelines for the treatment of patients with severe\/multiple injuries. Eur J Trauma Emerg Surg 51(1):171","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"2","key":"2502_CR3","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.ejvs.2024.12.018","volume":"69","author":"CM Wahlgren","year":"2025","unstructured":"Wahlgren CM, Aylwin C, Davenport RA, Davidovic LB, DuBose JJ, Gaarder C et al (2025) Editor's choice -- European Society for Vascular Surgery (ESVS) 2025 clinical practice guidelines on the management of vascular trauma. Eur J Vasc Endovasc Surg 69(2):179\u2013237","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"3","key":"2502_CR4","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1148\/radiol.11100604","volume":"261","author":"BR Foster","year":"2011","unstructured":"Foster BR, Anderson SW, Uyeda JW, Brooks JG, Soto JA (2011) Integration of 64-detector lower extremity CT angiography into whole-body trauma imaging: feasibility and early experience. Radiology 261(3):787\u2013795","journal-title":"Radiology"},{"issue":"4","key":"2502_CR5","doi-asserted-by":"publisher","first-page":"2461","DOI":"10.1007\/s00330-022-09278-1","volume":"33","author":"BV Becker","year":"2023","unstructured":"Becker BV, Kaatsch HL, Nestler K, Overhoff D, Schneider J, Dillinger D et al (2023) Initial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure. Eur Radiol 33(4):2461\u20132468","journal-title":"Eur Radiol"},{"key":"2502_CR6","doi-asserted-by":"crossref","unstructured":"Dillinger D, Overhoff D, Booz C, Kaatsch HL, Piechotka J, Hagen A et al (2023) Impact of CT Photon-counting virtual monoenergetic imaging on visualization of abdominal arterial vessels. Diagnostics (Basel) 13(5)","DOI":"10.3390\/diagnostics13050938"},{"key":"2502_CR7","doi-asserted-by":"crossref","unstructured":"Dillinger D, Overhoff D, Ayx I, Kaatsch HL, Hagen A, Schonberg SO et al (2024) Optimizing arterial vessel contrast in portal venous phase with virtual monoenergetic images from photon-counting detector CT scans of the abdomen-first clinical experiences. Diagnostics (Basel) 14(6)","DOI":"10.3390\/diagnostics14060627"},{"key":"2502_CR8","doi-asserted-by":"crossref","unstructured":"Dillinger D, Overhoff D, Froelich MF, Kaatsch HL, Booz C, Hagen A et al (2024) Photon-counting detector CT virtual monoenergetic images in cervical trauma imaging-optimization of dental metal artifacts and image quality. Diagnostics (Basel) 14(6)","DOI":"10.3390\/diagnostics14060626"},{"issue":"4","key":"2502_CR9","doi-asserted-by":"publisher","first-page":"2005","DOI":"10.1016\/j.acra.2024.10.045","volume":"32","author":"D Dillinger","year":"2025","unstructured":"Dillinger D, Waldeck S, Overhoff D, Faby S, Jurgens M, Schmidt B et al (2025) Automated Kidney Stone Composition Analysis with Photon-Counting Detector CT, a Performance Study-A Phantom Study. Acad Radiol 32(4):2005\u20132012","journal-title":"Acad Radiol"},{"key":"2502_CR10","first-page":"19","volume":"14","author":"HL Kaatsch","year":"2024","unstructured":"Kaatsch HL, Vollmecke MF, Becker BV, Dillinger D, Kubitscheck L, Wohler A et al (2024) Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT. Diagnostics (Basel) 14:19","journal-title":"Diagnostics (Basel)"},{"issue":"2","key":"2502_CR11","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1097\/RLI.0000000000000816","volume":"57","author":"A Euler","year":"2022","unstructured":"Euler A, Higashigaito K, Mergen V, Sartoretti T, Zanini B, Schmidt B et al (2022) High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta: Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose. Invest Radiol 57(2):115\u2013121","journal-title":"Invest Radiol"},{"issue":"2","key":"2502_CR12","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1148\/radiol.2019182297","volume":"293","author":"MH Albrecht","year":"2019","unstructured":"Albrecht MH, Vogl TJ, Martin SS, Nance JW, Duguay TM, Wichmann JL et al (2019) Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT. Radiology 293(2):260\u2013271","journal-title":"Radiology"},{"key":"2502_CR13","doi-asserted-by":"publisher","first-page":"1276738","DOI":"10.3389\/fcvm.2023.1276738","volume":"10","author":"G Fahrni","year":"2023","unstructured":"Fahrni G, Mingas T, Deliessche A, Hraichi S, Rotzinger DC, Si-Mohamed SA et al (2023) Low-iodine 40-keV virtual monoenergetic CT angiography of the lower extremities. Front Cardiovasc Med 10:1276738","journal-title":"Front Cardiovasc Med"},{"issue":"1","key":"2502_CR14","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1186\/s41747-018-0070-5","volume":"2","author":"S O\u2019Neill","year":"2018","unstructured":"O\u2019Neill S, Kavanagh RG, Carey BW, Moore N, Maher M, O\u2019Connor OJ (2018) Using body mass index to estimate individualised patient radiation dose in abdominal computed tomography. Eur Radiol Exp 2(1):38","journal-title":"Eur Radiol Exp"},{"issue":"3","key":"2502_CR15","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1148\/radiol.2493080652","volume":"249","author":"SW Anderson","year":"2008","unstructured":"Anderson SW, Foster BR, Soto JA (2008) Upper extremity CT angiography in penetrating trauma: use of 64-section multidetector CT. Radiology 249(3):1064\u20131073","journal-title":"Radiology"},{"issue":"1","key":"2502_CR16","doi-asserted-by":"publisher","first-page":"16143","DOI":"10.1038\/s41598-025-97868-6","volume":"15","author":"W Mei","year":"2025","unstructured":"Mei W, Tang Q, Li C, Wang S, Zhou Q, Xu L et al (2025) Improving lower-extremity artery depiction and diagnostic confidence using dual-energy technique and popliteal artery monitoring in dual-low dose CT angiography. Sci Rep 15(1):16143","journal-title":"Sci Rep"},{"issue":"11","key":"2502_CR17","doi-asserted-by":"publisher","first-page":"1633","DOI":"10.1007\/s11547-024-01889-6","volume":"129","author":"C Booz","year":"2024","unstructured":"Booz C, Bucolo GM, D\u2019Angelo T, Mazziotti S, Lanzafame LRM, Yel I et al (2024) Carotid artery assessment in dual-source photon-counting CT: impact of low-energy virtual monoenergetic imaging on image quality, vascular contrast and diagnostic assessability. Radiol Med 129(11):1633\u20131643","journal-title":"Radiol Med"},{"key":"2502_CR18","doi-asserted-by":"publisher","first-page":"109061","DOI":"10.1016\/j.ejrad.2020.109061","volume":"128","author":"X Jia","year":"2020","unstructured":"Jia X, Li X, Li J, Tian Q, Yao Y, Zhu S et al (2020) Improving diagnostic accuracy for arteries of lower extremities with dual-energy spectral CT imaging. Eur J Radiol 128:109061","journal-title":"Eur J Radiol"},{"issue":"8","key":"2502_CR19","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1097\/RLI.0000000000001058","volume":"59","author":"AA Marth","year":"2024","unstructured":"Marth AA, Goller SS, Kajdi GW, Marcus RP, Sutter R, Photon-Counting Detector CT (2024) Clinical Utility of Virtual Monoenergetic Imaging Combined With Tin Prefiltration to Reduce Metal Artifacts in the Postoperative Ankle. Invest Radiol 59(8):545\u2013553","journal-title":"Invest Radiol"},{"key":"2502_CR20","doi-asserted-by":"publisher","first-page":"111209","DOI":"10.1016\/j.ejrad.2023.111209","volume":"170","author":"TS Patzer","year":"2024","unstructured":"Patzer TS, Grunz JP, Huflage H, Hennes JL, Pannenbecker P, Gruschwitz P et al (2024) Ultra-high resolution photon-counting CT with tin prefiltration for bone-metal interface visualization. Eur J Radiol 170:111209","journal-title":"Eur J Radiol"},{"key":"2502_CR21","doi-asserted-by":"publisher","first-page":"110946","DOI":"10.1016\/j.ejrad.2023.110946","volume":"165","author":"D Popp","year":"2023","unstructured":"Popp D, Sinzinger AX, Decker JA, Braun F, Bette S, Risch F et al (2023) Spectral metal artifact reduction after posterior spinal fixation in photon-counting detector CT datasets. Eur J Radiol 165:110946","journal-title":"Eur J Radiol"},{"issue":"8","key":"2502_CR22","doi-asserted-by":"publisher","first-page":"5578","DOI":"10.1007\/s00330-023-09511-5","volume":"33","author":"A Rau","year":"2023","unstructured":"Rau A, Straehle J, Stein T, Diallo T, Rau S, Faby S et al (2023) Photon-Counting Computed Tomography (PC-CT) of the spine: impact on diagnostic confidence and radiation dose. Eur Radiol 33(8):5578\u20135586","journal-title":"Eur Radiol"},{"issue":"12","key":"2502_CR23","doi-asserted-by":"publisher","first-page":"9286","DOI":"10.1007\/s00330-023-09879-4","volume":"33","author":"J Schreck","year":"2023","unstructured":"Schreck J, Laukamp KR, Niehoff JH, Michael AE, Boriesosdick J, Woltjen MM et al (2023) Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images. Eur Radiol 33(12):9286\u20139295","journal-title":"Eur Radiol"},{"issue":"11","key":"2502_CR24","doi-asserted-by":"publisher","first-page":"7818","DOI":"10.1007\/s00330-023-09790-y","volume":"33","author":"TS Patzer","year":"2023","unstructured":"Patzer TS, Kunz AS, Huflage H, Gruschwitz P, Pannenbecker P, Afat S et al (2023) Combining virtual monoenergetic imaging and iterative metal artifact reduction in first-generation photon-counting computed tomography of patients with dental implants. Eur Radiol 33(11):7818\u20137829","journal-title":"Eur Radiol"},{"issue":"9","key":"2502_CR25","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1097\/RLI.0000000000000967","volume":"58","author":"F Risch","year":"2023","unstructured":"Risch F, Decker JA, Popp D, Sinzinger A, Braun F, Bette S et al (2023) Artifact Reduction From Dental Material in Photon-Counting Detector Computed Tomography Data Sets Based on High-keV Monoenergetic Imaging and Iterative Metal Artifact Reduction Reconstructions-Can We Combine the Best of Two Worlds? Invest Radiol 58(9):691\u2013696","journal-title":"Invest Radiol"},{"issue":"3","key":"2502_CR26","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s10140-022-02037-1","volume":"29","author":"R Joshi","year":"2022","unstructured":"Joshi R, LeBedis C, Dao K, Qureshi M, Gupta A (2022) Dual energy CT angiography for lower extremity trauma: comparison with conventional CT. Emerg Radiol 29(3):471\u2013477","journal-title":"Emerg Radiol"}],"container-title":["Emergency Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-026-02502-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10140-026-02502-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10140-026-02502-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T23:03:34Z","timestamp":1790982214000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10140-026-02502-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,16]]},"references-count":26,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["2502"],"URL":"https:\/\/doi.org\/10.1007\/s10140-026-02502-1","relation":{},"ISSN":["1438-1435"],"issn-type":[{"value":"1438-1435","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,16]]},"assertion":[{"value":"4 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}