{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T04:18:59Z","timestamp":1768450739817,"version":"3.49.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2022,1,13]],"date-time":"2022-01-13T00:00:00Z","timestamp":1642032000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,13]],"date-time":"2022-01-13T00:00:00Z","timestamp":1642032000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"National Key Research and Development Program of China","award":["2018YFC1002500"],"award-info":[{"award-number":["2018YFC1002500"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neurosurg Rev"],"published-print":{"date-parts":[[2022,6]]},"DOI":"10.1007\/s10143-021-01729-5","type":"journal-article","created":{"date-parts":[[2022,1,13]],"date-time":"2022-01-13T05:46:22Z","timestamp":1642052782000},"page":"2183-2192","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Can C1 lateral mass and C3 pedicle screw fixation be used as an option for atlantoaxial reduction and stabilization in Klippel-Feil patients? A study of its morphological feasibility, technical nuances, and clinical efficiency"],"prefix":"10.1007","volume":"45","author":[{"given":"Yue-Qi","family":"Du","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi-Heng","family":"Yin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teng","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8518-0642","authenticated-orcid":false,"given":"Guang-Yu","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin-Guang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,13]]},"reference":[{"key":"1729_CR1","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3406\/bmsap.1912.8505","volume":"3","author":"FA Klippel","year":"1912","unstructured":"Klippel FA (1912) Un cas d\u2019absence des ver-tebres cerviales. Avec cage thoracique remontant jusqu\u2019a la base du crane (cage thoracique cervicale). Cahiers Du Centre De Recherches Anthropologiques 3:101\u2013102. https:\/\/doi.org\/10.3406\/bmsap.1912.8505","journal-title":"Cahiers Du Centre De Recherches Anthropologiques"},{"key":"1729_CR2","doi-asserted-by":"publisher","unstructured":"Shen FH, Samartzis D, Herman J, Lubicky JP (2006) Radiographic assessment of segmental motion at the atlantoaxial junction in the Klippel-Feil patient. Spine (Phila Pa 1976) 31 (2):171\u2013177.https:\/\/doi.org\/10.1097\/01.brs.0000195347.35380.68","DOI":"10.1097\/01.brs.0000195347.35380.68"},{"key":"1729_CR3","doi-asserted-by":"publisher","unstructured":"Wang S, Wang C, Leng H, Zhao W, Yan M, Zhou H (2012) Cable-strengthened C2 pedicle screw fixation in the treatment of congenital C2\u20133 fusion, atlas occipitalization, and atlantoaxial dislocation. Neurosurgery 71 (5):976\u2013984; discussion 984.https:\/\/doi.org\/10.1227\/NEU.0b013e31826cdd3b","DOI":"10.1227\/NEU.0b013e31826cdd3b"},{"key":"1729_CR4","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.wneu.2016.07.058","volume":"95","author":"YH Yin","year":"2016","unstructured":"Yin YH, Qiao GY, Yu XG (2016) Surgical treatment of occipitocervical dislocation with atlas assimilation and Klippel-Feil syndrome using occipitalized C1 lateral mass and C2 fixation and reduction technique. World Neurosurg 95:46\u201352. https:\/\/doi.org\/10.1016\/j.wneu.2016.07.058","journal-title":"World Neurosurg"},{"key":"1729_CR5","doi-asserted-by":"crossref","unstructured":"Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51 (6):1351\u20131356; discussion 1356\u20131357","DOI":"10.1097\/00006123-200212000-00004"},{"issue":"1\u20132","key":"1729_CR6","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/bf01400872","volume":"129","author":"A Goel","year":"1994","unstructured":"Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129(1\u20132):47\u201353. https:\/\/doi.org\/10.1007\/bf01400872","journal-title":"Acta Neurochir (Wien)"},{"key":"1729_CR7","doi-asserted-by":"crossref","unstructured":"Harms J, Melcher RP (2001) Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26 (22):2467\u20132471","DOI":"10.1097\/00007632-200111150-00014"},{"key":"1729_CR8","doi-asserted-by":"publisher","unstructured":"Yin YH, Tong HY, Qiao GY, Yu XG (2016) Posterior reduction of fixed atlantoaxial dislocation and basilar invagination by atlantoaxial facet joint release and fixation: a modified technique with 174 cases. Neurosurgery 78 (3):391\u2013400; discussion 400.https:\/\/doi.org\/10.1227\/NEU.0000000000001026","DOI":"10.1227\/NEU.0000000000001026"},{"issue":"2","key":"1729_CR9","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1097\/00024720-200404000-00014","volume":"17","author":"NM Wright","year":"2004","unstructured":"Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17(2):158\u2013162","journal-title":"J Spinal Disord Tech"},{"issue":"3 Suppl","key":"1729_CR10","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1227\/01.Neu.0000365743.16893.Ea","volume":"66","author":"DS Yanni","year":"2010","unstructured":"Yanni DS, Perin NI (2010) Fixation of the axis. Neurosurgery 66(3 Suppl):147\u2013152. https:\/\/doi.org\/10.1227\/01.Neu.0000365743.16893.Ea","journal-title":"Neurosurgery"},{"key":"1729_CR11","doi-asserted-by":"publisher","unstructured":"Chang CC, Huang WC, Tu TH, Chang PY, Fay LY, Wu JC, Cheng H (2018) Differences in fixation strength among constructs of atlantoaxial fixation. J Neurosurg Spine:1\u20138.https:\/\/doi.org\/10.3171\/2018.6.SPINE171390","DOI":"10.3171\/2018.6.SPINE171390"},{"key":"1729_CR12","doi-asserted-by":"crossref","unstructured":"Dmitriev AE, Lehman RA, Jr., Helgeson MD, Sasso RC, Kuhns C, Riew DK (2009) Acute and long-term stability of atlantoaxial fixation methods: a biomechanical comparison of pars, pedicle, and intralaminar fixation in an intact and odontoid fracture model. Spine (Phila Pa 1976) 34 (4):365-370.10.1097\/BRS.0b013e3181976aa9","DOI":"10.1097\/BRS.0b013e3181976aa9"},{"key":"1729_CR13","doi-asserted-by":"publisher","unstructured":"Dorward IG, Wright NM (2011) Seven years of experience with C2 translaminar screw fixation: clinical series and review of the literature. Neurosurgery 68 (6):1491\u20131499; discussion 1499.https:\/\/doi.org\/10.1227\/NEU.0b013e318212a4d7","DOI":"10.1227\/NEU.0b013e318212a4d7"},{"issue":"6","key":"1729_CR14","doi-asserted-by":"publisher","first-page":"577","DOI":"10.3171\/2012.9.Spine111021","volume":"17","author":"RE Elliott","year":"2012","unstructured":"Elliott RE, Tanweer O, Boah A, Smith ML, Frempong-Boadu A (2012) Comparison of safety and stability of C-2 pars and pedicle screws for atlantoaxial fusion: meta-analysis and review of the literature. J Neurosurg Spine 17(6):577\u2013593. https:\/\/doi.org\/10.3171\/2012.9.Spine111021","journal-title":"J Neurosurg Spine"},{"issue":"8","key":"1729_CR15","doi-asserted-by":"publisher","first-page":"1730","DOI":"10.1007\/s00586-014-3397-5","volume":"23","author":"P Xiu","year":"2014","unstructured":"Xiu P, Wang Q, Wang G, Wang S, Dai G, Lan Y (2014) Morphological and clinical feasibility of C3 pedicle screw instrumentation in patients with congenital C2\u20133 fusion. Eur Spine J 23(8):1730\u20131736. https:\/\/doi.org\/10.1007\/s00586-014-3397-5","journal-title":"Eur Spine J"},{"key":"1729_CR16","doi-asserted-by":"publisher","first-page":"e722","DOI":"10.1016\/j.wneu.2019.09.139","volume":"133","author":"YQ Du","year":"2020","unstructured":"Du YQ, Qiao GY, Yin YH, Li T, Tong HY, Yu XG (2020) Usefulness of 3D printed models in the management of complex craniovertebral junction anomalies: choice of treatment strategy, design of screw trajectory, and protection of vertebral artery. World Neurosurg 133:e722\u2013e729. https:\/\/doi.org\/10.1016\/j.wneu.2019.09.139","journal-title":"World Neurosurg"},{"key":"1729_CR17","doi-asserted-by":"publisher","unstructured":"Yin YH, Yu XG, Qiao GY, Guo SL, Zhang JN (2014) C1 lateral mass screw placement in occipitalization with atlantoaxial dislocation and basilar invagination: a report of 146 cases. Spine (Phila Pa 1976) 39 (24):2013\u20132018.https:\/\/doi.org\/10.1097\/brs.0000000000000611","DOI":"10.1097\/brs.0000000000000611"},{"key":"1729_CR18","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.wneu.2017.01.015","volume":"100","author":"A Goel","year":"2017","unstructured":"Goel A (2017) Caudally directed inferior facetal and transfacetal screws for C1\u2013C2 and C1-2-3 fixation. World Neurosurg 100:236\u2013243. https:\/\/doi.org\/10.1016\/j.wneu.2017.01.015","journal-title":"World Neurosurg"},{"key":"1729_CR19","doi-asserted-by":"publisher","first-page":"e70","DOI":"10.1016\/j.wneu.2018.09.014","volume":"121","author":"R Zong","year":"2019","unstructured":"Zong R, Li T, Lu L, Qiao G, Yu X (2019) Posterior C2 fixation using trans-C2 inferior articular process screws: a case series and technical note. World Neurosurg 121:e70\u2013e76. https:\/\/doi.org\/10.1016\/j.wneu.2018.09.014","journal-title":"World Neurosurg"},{"issue":"1","key":"1729_CR20","doi-asserted-by":"publisher","first-page":"15","DOI":"10.3171\/2009.3.Spine08166","volume":"11","author":"DM Sciubba","year":"2009","unstructured":"Sciubba DM, Noggle JC, Vellimana AK, Alosh H, McGirt MJ, Gokaslan ZL, Wolinsky JP (2009) Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws. Clinical article J Neurosurg Spine 11(1):15\u201322. https:\/\/doi.org\/10.3171\/2009.3.Spine08166","journal-title":"Clinical article J Neurosurg Spine"},{"issue":"8","key":"1729_CR21","doi-asserted-by":"publisher","first-page":"1306","DOI":"10.1007\/s00586-010-1418-6","volume":"19","author":"S Wang","year":"2010","unstructured":"Wang S, Wang C, Passias PG, Yan M, Zhou H (2010) Pedicle versus laminar screws: what provides more suitable C2 fixation in congenital C2\u20133 fusion patients? Eur Spine J 19(8):1306\u20131311. https:\/\/doi.org\/10.1007\/s00586-010-1418-6","journal-title":"Eur Spine J"},{"key":"1729_CR22","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.wneu.2016.07.037","volume":"94","author":"RS Tubbs","year":"2016","unstructured":"Tubbs RS, Granger A, Fisahn C, Loukas M, Moisi M, Iwanaga J, Paulson D, Jeyamohan S, Chapman JR, Oskouian RJ (2016) The vertebral artery cave at C2: anatomic study with application to C2 pedicle screw placement. World Neurosurg 94:368\u2013374. https:\/\/doi.org\/10.1016\/j.wneu.2016.07.037","journal-title":"World Neurosurg"},{"key":"1729_CR23","doi-asserted-by":"publisher","unstructured":"Du YQ, Li T, Ma C, Qiao GY, Yin YH, Yu XG (2020) Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2\/3 transarticular screw fixation. J Neurosurg Spine:1\u20137.https:\/\/doi.org\/10.3171\/2019.11.Spine191178","DOI":"10.3171\/2019.11.Spine191178"},{"key":"1729_CR24","doi-asserted-by":"publisher","unstructured":"Park JH, Jeon SR, Roh SW, Kim JH, Rhim SC (2014) The safety and accuracy of freehand pedicle screw placement in the subaxial cervical spine: a series of 45 consecutive patients. Spine (Phila Pa 1976) 39 (4):280\u2013285.https:\/\/doi.org\/10.1097\/brs.0000000000000133","DOI":"10.1097\/brs.0000000000000133"},{"key":"1729_CR25","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.clineuro.2014.07.017","volume":"125","author":"M Bydon","year":"2014","unstructured":"Bydon M, Mathios D, Macki M, De la Garza-Ramos R, Aygun N, Sciubba DM, Witham TF, Gokaslan ZL, Bydon A, Wolinksy JP (2014) Accuracy of C2 pedicle screw placement using the anatomic freehand technique. Clin Neurol Neurosurg 125:24\u201327. https:\/\/doi.org\/10.1016\/j.clineuro.2014.07.017","journal-title":"Clin Neurol Neurosurg"},{"issue":"7","key":"1729_CR26","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/j.spinee.2017.11.010","volume":"18","author":"P Punyarat","year":"2018","unstructured":"Punyarat P, Buchowski JM, Klawson BT, Peters C, Lertudomphonwanit T, Riew KD (2018) Freehand technique for C2 pedicle and pars screw placement: is it safe? Spine J 18(7):1197\u20131203. https:\/\/doi.org\/10.1016\/j.spinee.2017.11.010","journal-title":"Spine J"},{"key":"1729_CR27","doi-asserted-by":"publisher","unstructured":"Du YQ, Yin YH, Qiao GY, Yu XG (2020) C2 medial pedicle screw: a novel \u201cin-out-in\u201d technique as an alternative option for posterior C2 fixation in cases with a narrow C2 isthmus. J Neurosurg Spine:1\u20137.https:\/\/doi.org\/10.3171\/2020.2.Spine191517","DOI":"10.3171\/2020.2.Spine191517"}],"container-title":["Neurosurgical Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10143-021-01729-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10143-021-01729-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10143-021-01729-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T05:08:05Z","timestamp":1654060085000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10143-021-01729-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,13]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["1729"],"URL":"https:\/\/doi.org\/10.1007\/s10143-021-01729-5","relation":{},"ISSN":["1437-2320"],"issn-type":[{"value":"1437-2320","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,13]]},"assertion":[{"value":"28 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 December 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 December 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 January 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was conducted under the auspices of the Ethic Committee of Chinese PLA General Hospital (S2018\u2013280\u201301). This study followed all requirements of the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Formal consent is not required for the retrospective and noninterventional study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}}]}}