{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T06:39:15Z","timestamp":1789799955380,"version":"4.0.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Neurosurg Rev"],"DOI":"10.1007\/s10143-024-02306-2","type":"journal-article","created":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T06:03:03Z","timestamp":1707112983000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Risk factor analysis of changes in blood flow in the A1 segment of the anterior cerebral artery after flow-diverter coverage of it"],"prefix":"10.1007","volume":"47","author":[{"given":"WuLin","family":"Ma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JunFan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"XinBin","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,5]]},"reference":[{"issue":"4","key":"2306_CR1","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1177\/1971400915602803","volume":"28","author":"F Briganti","year":"2015","unstructured":"Briganti F, Leone G, Marseglia M et al (2015) Endovascular treatment of cerebral aneurysms using flow-diverter devices: a systematic review. Neuroradiol J 28(4):365\u2013375","journal-title":"Neuroradiol J"},{"issue":"9","key":"2306_CR2","doi-asserted-by":"publisher","first-page":"1745","DOI":"10.1007\/s00701-016-2875-4","volume":"158","author":"F Briganti","year":"2016","unstructured":"Briganti F, Leone G, Ugga L et al (2016) Safety and efficacy of flow re-direction endoluminal device (FRED) in the treatment of cerebral aneurysms: a single center experience. Acta Neurochir (Wien) 158(9):1745\u20131755","journal-title":"Acta Neurochir (Wien)"},{"issue":"1","key":"2306_CR3","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1136\/neurintsurg-2016-012502","volume":"9","author":"F Briganti","year":"2017","unstructured":"Briganti F, Leone G, Ugga L et al (2017) Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience. J Neurointerv Surg 9(1):70\u201376","journal-title":"J Neurointerv Surg"},{"issue":"1","key":"2306_CR4","doi-asserted-by":"publisher","first-page":"98","DOI":"10.3174\/ajnr.A4078","volume":"36","author":"AK Wakhloo","year":"2015","unstructured":"Wakhloo AK, Lylyk P, de Vries J et al (2015) Surpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study. AJNR Am J Neuroradiol 36(1):98\u2013107","journal-title":"AJNR Am J Neuroradiol"},{"issue":"3","key":"2306_CR5","doi-asserted-by":"publisher","first-page":"542","DOI":"10.3174\/ajnr.A4143","volume":"36","author":"B Lubicz","year":"2015","unstructured":"Lubicz B, Van der Elst O, Collignon L, Mine B, Alghamdi F (2015) Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results. AJNR Am J Neuroradiol 36(3):542\u2013546","journal-title":"AJNR Am J Neuroradiol"},{"issue":"3","key":"2306_CR6","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1007\/s00062-009-9005-0","volume":"19","author":"L Augsburger","year":"2009","unstructured":"Augsburger L, Farhat M, Reymond P et al (2009) Effect of flow diverter porosity on intraaneurysmal blood flow. Klin Neuroradiol 19(3):204\u2013214","journal-title":"Klin Neuroradiol"},{"issue":"6","key":"2306_CR7","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1114\/1.1495867","volume":"30","author":"BB Lieber","year":"2002","unstructured":"Lieber BB, Livescu V, Hopkins LN, Wakhloo AK (2002) Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow. Ann Biomed Eng 30(6):768\u2013777","journal-title":"Ann Biomed Eng"},{"issue":"3","key":"2306_CR8","doi-asserted-by":"publisher","first-page":"034506","DOI":"10.1115\/1.3049528","volume":"131","author":"AL Trager","year":"2009","unstructured":"Trager AL, Sadasivan C, Seong J, Lieber BB (2009) Correlation between angiographic and particle image velocimetry quantifications of flow diverters in an in vitro model of elastase-induced rabbit aneurysms. J Biomech Eng 131(3):034506","journal-title":"J Biomech Eng"},{"issue":"4","key":"2306_CR9","doi-asserted-by":"publisher","first-page":"725","DOI":"10.3174\/ajnr.A4191","volume":"36","author":"G Gascou","year":"2015","unstructured":"Gascou G, Lobotesis K, Brunel H et al (2015) Extra-aneurysmal flow modification following Pipeline embolization device implantation: focus on regional branches, perforators, and the parent vessel. AJNR Am J Neuroradiol 36(4):725\u2013731","journal-title":"AJNR Am J Neuroradiol"},{"issue":"10-S","key":"2306_CR10","first-page":"e2020003","volume":"91","author":"S Hohenstatt","year":"2020","unstructured":"Hohenstatt S, Arrichiello A, Conte G et al (2020) Branch vessel occlusion in aneurysm treatment with flow diverter stent. Acta Biomed. 91(10-S):e2020003","journal-title":"Acta Biomed."},{"issue":"1","key":"2306_CR11","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.neurad.2018.07.006","volume":"46","author":"F Cagnazzo","year":"2019","unstructured":"Cagnazzo F, Lefevre PH, Mantilla D et al (2019) Patency of the supraclinoid internal carotid artery branches after flow diversion treatment A meta-analysis. J Neuroradiol 46(1):9\u201314","journal-title":"J Neuroradiol"},{"issue":"5","key":"2306_CR12","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1136\/neurintsurg-2014-011183","volume":"7","author":"E Nossek","year":"2015","unstructured":"Nossek E, Chalif DJ, Levine M, Setton A (2015) Modifying flow in the ACA-ACoA complex: endovascular treatment option for wide-neck internal carotid artery bifurcation aneurysms. J Neurointerv Surg 7(5):351\u2013356","journal-title":"J Neurointerv Surg"},{"issue":"2","key":"2306_CR13","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1177\/159101991001600204","volume":"16","author":"CJ O'Kelly","year":"2010","unstructured":"O\u2019Kelly CJ, Krings T, Fiorella D, Marotta TR (2010) A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents. Interv Neuroradiol 16(2):133\u2013137","journal-title":"Interv Neuroradiol"},{"issue":"12","key":"2306_CR14","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1136\/neurintsurg-2020-016051","volume":"12","author":"F Cagnazzo","year":"2020","unstructured":"Cagnazzo F, Ahmed R, Lefevre PH et al (2020) Flow modification on the internal carotid artery bifurcation region and A1 segment after M1-internal carotid artery flow diverter deployment. J Neurointerv Surg 12(12):1226\u20131230","journal-title":"J Neurointerv Surg"},{"issue":"11","key":"2306_CR15","doi-asserted-by":"publisher","first-page":"2125","DOI":"10.3174\/ajnr.A4013","volume":"35","author":"E Nossek","year":"2014","unstructured":"Nossek E, Chalif DJ, Chakraborty S, Setton A (2014) Modifying flow in the ICA bifurcation: Pipeline deployment from the supraclinoid ICA extending into the M1 segment-clinical and anatomic results. AJNR Am J Neuroradiol Nov-Dec 35(11):2125\u20132129","journal-title":"AJNR Am J Neuroradiol Nov-Dec"},{"issue":"3","key":"2306_CR16","doi-asserted-by":"publisher","first-page":"H1173","DOI":"10.1152\/ajpheart.00821.2010","volume":"301","author":"P Reymond","year":"2011","unstructured":"Reymond P, Bohraus Y, Perren F, Lazeyras F, Stergiopulos N (2011) Validation of a patient-specific one-dimensional model of the systemic arterial tree. Am J Physiol Heart Circ Physiol 301(3):H1173-1182","journal-title":"Am J Physiol Heart Circ Physiol"},{"issue":"Suppl 1","key":"2306_CR17","doi-asserted-by":"publisher","first-page":"i9","DOI":"10.1136\/jnis.2009.000083.rep","volume":"10","author":"D Fiorella","year":"2018","unstructured":"Fiorella D, Lylyk P, Szikora I et al (2018) Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms. J Neurointerv Surg 10(Suppl 1):i9\u2013i18","journal-title":"J Neurointerv Surg"},{"key":"2306_CR18","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.clineuro.2014.02.018","volume":"120","author":"W Brinjikji","year":"2014","unstructured":"Brinjikji W, Lanzino G, Cloft HJ, Kallmes DF (2014) Patency of the posterior communicating artery after flow diversion treatment of internal carotid artery aneurysms. Clin Neurol Neurosurg 120:84\u201388","journal-title":"Clin Neurol Neurosurg"},{"issue":"2","key":"2306_CR19","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1227\/NEU.0000000000000595","volume":"76","author":"A Vedantam","year":"2015","unstructured":"Vedantam A, Rao VY, Shaltoni HM, Mawad ME (2015) Incidence and clinical implications of carotid branch occlusion following treatment of internal carotid artery aneurysms with the Pipeline embolization device. Neurosurgery 76(2):173\u2013178","journal-title":"Neurosurgery"},{"issue":"6","key":"2306_CR20","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1227\/01.NEU.0000064567.15270.27","volume":"52","author":"DK Lopes","year":"2003","unstructured":"Lopes DK, Ringer AJ, Boulos AS et al (2003) Fate of branch arteries after intracranial stenting. Neurosurgery 52(6):1275\u20131278","journal-title":"Neurosurgery"},{"issue":"5","key":"2306_CR21","first-page":"1043","volume":"16","author":"AK Wakhloo","year":"1995","unstructured":"Wakhloo AK, Tio FO, Lieber BB, Schellhammer F, Graf M, Hopkins LN (1995) Self-expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response. AJNR Am J Neuroradiol 16(5):1043\u20131051","journal-title":"AJNR Am J Neuroradiol"},{"issue":"8","key":"2306_CR22","doi-asserted-by":"publisher","first-page":"2346","DOI":"10.1161\/STROKEAHA.106.479576","volume":"38","author":"DF Kallmes","year":"2007","unstructured":"Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ (2007) A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 38(8):2346\u20132352","journal-title":"Stroke"},{"issue":"4","key":"2306_CR23","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1161\/STROKEAHA.111.636019","volume":"43","author":"S Pistocchi","year":"2012","unstructured":"Pistocchi S, Blanc R, Bartolini B, Piotin M (2012) Flow diverters at and beyond the level of the circle of willis for the treatment of intracranial aneurysms. Stroke 43(4):1032\u20131038","journal-title":"Stroke"},{"issue":"6","key":"2306_CR24","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1227\/NEU.0000000000000522","volume":"75","author":"S Saleme","year":"2014","unstructured":"Saleme S, Iosif C, Ponomarjova S et al (2014) Flow-diverting stents for intracranial bifurcation aneurysm treatment. Neurosurgery. 75(6):623\u2013631","journal-title":"Neurosurgery."}],"container-title":["Neurosurgical Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10143-024-02306-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10143-024-02306-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10143-024-02306-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T05:43:14Z","timestamp":1741066994000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10143-024-02306-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,5]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2306"],"URL":"https:\/\/doi.org\/10.1007\/s10143-024-02306-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-3502386\/v1","asserted-by":"object"}]},"ISSN":["1437-2320"],"issn-type":[{"value":"1437-2320","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,5]]},"assertion":[{"value":"28 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 January 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This is an observational study. The Zhengzhou University First Affiliated Hospital Research Ethics Committee has confirmed that no ethical approval is required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"74"}}