{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,26]],"date-time":"2026-07-26T04:46:49Z","timestamp":1785041209029,"version":"3.55.0"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2021,2,4]],"date-time":"2021-02-04T00:00:00Z","timestamp":1612396800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,2,4]],"date-time":"2021-02-04T00:00:00Z","timestamp":1612396800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000055","name":"National Institute on Deafness and Other Communication Disorders","doi-asserted-by":"publisher","award":["P50 DC 00242"],"award-info":[{"award-number":["P50 DC 00242"]}],"id":[{"id":"10.13039\/100000055","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["JARO"],"published-print":{"date-parts":[[2021,4]]},"DOI":"10.1007\/s10162-021-00785-4","type":"journal-article","created":{"date-parts":[[2021,2,4]],"date-time":"2021-02-04T16:26:59Z","timestamp":1612456019000},"page":"161-176","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Residual Hair Cell Responses in Electric-Acoustic Stimulation Cochlear Implant Users with Complete Loss of Acoustic Hearing After Implantation"],"prefix":"10.1007","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7585-9619","authenticated-orcid":false,"given":"Viral D.","family":"Tejani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeong-Seo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6343-3274","authenticated-orcid":false,"given":"Jacob J.","family":"Oleson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul J.","family":"Abbas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolyn J.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6884-4897","authenticated-orcid":false,"given":"Marlan R.","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9916-6048","authenticated-orcid":false,"given":"Bruce J.","family":"Gantz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,2,4]]},"reference":[{"key":"785_CR1","doi-asserted-by":"publisher","unstructured":"Abbas PJ, Tejani VD, Scheperle RA, Brown CJ (2017) Using neural response telemetry to monitor physiological responses to acoustic stimulation in hybrid cochlear implant users. Ear Hear. 38(4):409\u2013425. https:\/\/doi.org\/10.1097\/AUD.0000000000000400","DOI":"10.1097\/AUD.0000000000000400"},{"key":"785_CR2","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1159\/000262601","volume":"67","author":"OF Adunka","year":"2010","unstructured":"Adunka OF, Pillsbury HC, Buchman CA (2010) Minimizing intracochlear trauma during cochlear implantation. Adv Otorhinolaryngol. 67:96\u2013107. https:\/\/doi.org\/10.1159\/000262601","journal-title":"Adv Otorhinolaryngol."},{"key":"785_CR3","first-page":"55e65","volume-title":"Electrocochleography","author":"J-M Aran","year":"1976","unstructured":"Aran J-M, Charlet de Sauvage R (1976) Clinical value of cochlear microphonic recordings. In: Ruben RJ, Elberling C, Salomon G (eds) Electrocochleography. University Park Press, Baltimore, MD, p 55e65"},{"issue":"5","key":"785_CR4","doi-asserted-by":"publisher","first-page":"3130","DOI":"10.1121\/1.1804627","volume":"116","author":"D Ba\u015fkent","year":"2004","unstructured":"Ba\u015fkent D, Shannon RV (2004) Frequency-place compression and expansion in cochlear implant listeners. J Acoust Soc Am. 116(5):3130\u20133140. https:\/\/doi.org\/10.1121\/1.1804627","journal-title":"J Acoust Soc Am."},{"issue":"3 Pt 1","key":"785_CR5","doi-asserted-by":"publisher","first-page":"1405","DOI":"10.1121\/1.1856273","volume":"117","author":"D Ba\u015fkent","year":"2005","unstructured":"Ba\u015fkent D, Shannon RV (2005) Interactions between cochlear implant electrode insertion depth and frequency-place mapping. J Acoust Soc Am. 117(3 Pt 1):1405\u20131416. https:\/\/doi.org\/10.1121\/1.1856273","journal-title":"J Acoust Soc Am."},{"key":"785_CR6","doi-asserted-by":"publisher","unstructured":"Briggs RJ, Tykocinski M, Xu J, Risi F, Svehla M, Cowan R, Stover T, Erfurt P, Lenarz T (2006) Comparison of round window and cochleostomy approaches with a prototype hearing preservation electrode. Audiol. Neuro. Otol. 42e48. https:\/\/doi.org\/10.1159\/000095613","DOI":"10.1159\/000095613"},{"issue":"1-2","key":"785_CR7","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.heares.2005.03.018","volume":"205","author":"C-H Choi","year":"2005","unstructured":"Choi C-H, Oghalai JS (2005) Predicting the effect of post-implant cochlear fibrosis on residual hearing. Hear Res. 205(1-2):193\u2013200. https:\/\/doi.org\/10.1016\/j.heares.2005.03.018","journal-title":"Hear Res."},{"key":"785_CR8","doi-asserted-by":"publisher","unstructured":"Choi J, Payne MR, Campbell LJ, Bester CW, Newbold C, Eastwood H, O'Leary SJ (2017) Electrode impedance fluctuations as a biomarker for inner ear pathology after cochlear implantation. Otol Neurotol. 38(10):1433\u20131439. https:\/\/doi.org\/10.1097\/MAO.0000000000001589","DOI":"10.1097\/MAO.0000000000001589"},{"issue":"9","key":"785_CR9","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1097\/MAO.0b013e31826dbc80","volume":"33","author":"B Choudhury","year":"2012","unstructured":"Choudhury B, Fitzpatrick DC, Buchman CA, Wei BP, Dillon MT, He S, Adunka OF (2012) Intraoperative round window recordings to acoustic stimuli from cochlear implant patients. Otol Neurotol. 33(9):1507\u20131515. https:\/\/doi.org\/10.1097\/MAO.0b013e31826dbc80","journal-title":"Otol Neurotol."},{"key":"785_CR10","doi-asserted-by":"publisher","unstructured":"Driscoll CL, Carlson ML, Fama AF, Lane JI (2011) Evaluation of the Hybrid-L24 electrode using microcomputed tomography. Laryngoscope 121(7):e1508\u2013e1516. https:\/\/doi.org\/10.1002\/lary.21837","DOI":"10.1002\/lary.21837"},{"key":"785_CR11","doi-asserted-by":"publisher","unstructured":"Dunn CC, Oleson J, Parkinson A, Hansen MR, Gantz BJ (2020) Nucleus hybrid S12: multicenter clinical trial results. Laryngoscope. 130(10):E548\u2013E558. https:\/\/doi.org\/10.1002\/lary.28628","DOI":"10.1002\/lary.28628"},{"issue":"4","key":"785_CR12","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1109\/tbme.1976.324585","volume":"23","author":"AM Dymond","year":"1976","unstructured":"Dymond AM (1976) Characteristics of the metal-tissue interface of stimulation electrodes. IEEE Trans Biomed Eng. 23(4):274\u2013280. https:\/\/doi.org\/10.1109\/tbme.1976.324585","journal-title":"IEEE Trans Biomed Eng."},{"key":"785_CR13","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3389\/fnsys.2017.00002","volume":"11","author":"JJ Eggermont","year":"2017","unstructured":"Eggermont JJ (2017) Ups and Downs in 75 Years of Electrocochleography. Front Syst Neurosci. 11:2. https:\/\/doi.org\/10.3389\/fnsys.2017.00002","journal-title":"Front Syst Neurosci."},{"key":"785_CR14","doi-asserted-by":"publisher","unstructured":"Eshraghi AA, Gupta C, Van De Water TR, Bohorquez JE, Garnham C, Bas E, Talamo VM (2013) Molecular mechanisms involved in cochlear implantation trauma and the protection of hearing and auditory sensory cells by inhibition of c-Jun-N-terminal kinase signaling. Laryngoscope. 123 Suppl 1:S1\u201314. https:\/\/doi.org\/10.1002\/lary.23902","DOI":"10.1002\/lary.23902"},{"issue":"1","key":"785_CR15","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1097\/MAO.0000000000000219","volume":"35","author":"DC Fitzpatrick","year":"2014","unstructured":"Fitzpatrick DC, Campbell AP, Choudhury B, Dillon MT, Forgues M, Buchman CA, Adunka OF (2014) Round window electrocochleography just before cochlear implantation: relationship to word recognition outcomes in adults. Otol Neurotol 35(1):64\u201371. https:\/\/doi.org\/10.1097\/MAO.0000000000000219","journal-title":"Otol Neurotol"},{"issue":"6","key":"785_CR16","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1002\/lio2.329","volume":"4","author":"MJ Foggia","year":"2019","unstructured":"Foggia MJ, Quevedo RV, Hansen MR (2019) Intracochlear fibrosis and the foreign body response to cochlear implant biomaterials. Laryngoscope Investig Otolaryngol 4(6):678\u2013683. https:\/\/doi.org\/10.1002\/lio2.329","journal-title":"Laryngoscope Investig Otolaryngol"},{"key":"785_CR17","doi-asserted-by":"publisher","unstructured":"Fontenot TE, Giardina CK, Dillon M, Rooth MA, Teagle HF, Park LR, Brown KD, Adunka OF, Buchman CA, Pillsbury HC, Fitzpatrick DC (2019) Residual cochlear function in adults and children receiving cochlear implants: correlations with speech perception outcomes. Ear Hear. 40(3):577\u2013591. https:\/\/doi.org\/10.1097\/AUD.0000000000000630","DOI":"10.1097\/AUD.0000000000000630"},{"issue":"3","key":"785_CR18","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1152\/jn.00446.2013","volume":"111","author":"M Forgues","year":"2014","unstructured":"Forgues M, Koehn HA, Dunnon AK, Pulver SH, Buchman CA, Adunka OF, Fitzpatrick DC (2014) Distinguishing hair cell from neural potentials recorded at the round window. J Neurophysiol. 111(3):580\u2013593. https:\/\/doi.org\/10.1152\/jn.00446.2013","journal-title":"J Neurophysiol."},{"issue":"2","key":"785_CR19","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1097\/AUD.0000000000000106","volume":"36","author":"E Formeister","year":"2015","unstructured":"Formeister E, McClellan JH, Merwin WH 3rd, Iseli CE, Calloway NH, Teagle HF, Buchman CA, Adunka OF, Fitzpatrick DC (2015) Intraoperative round window electrocochleography and speech perception outcomes in pediatric cochlear implant recipients. Ear Hear. 36(2):249\u2013260. https:\/\/doi.org\/10.1097\/AUD.0000000000000106","journal-title":"Ear Hear."},{"key":"785_CR20","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1002\/lary.25572","volume":"126","author":"BJ Gantz","year":"2016","unstructured":"Gantz BJ, Dunn CC, Oleson J, Hansen MR, Parkinson A, Turner C (2016) Multicenter clinical trial of the Nucleus hybrid S8 cochlear implant: Final outcomes. Laryngoscope. 126:962\u2013973. https:\/\/doi.org\/10.1002\/lary.25572","journal-title":"Laryngoscope."},{"key":"785_CR21","doi-asserted-by":"publisher","unstructured":"Gantz BJ, Dunn CC, Oleson J, Hansen MR (2018) Acoustic plus electric speech processing: long-term results. Laryngoscope. 128(2):473\u2013481. https:\/\/doi.org\/10.1002\/lary.26669","DOI":"10.1002\/lary.26669"},{"issue":"6","key":"785_CR22","doi-asserted-by":"publisher","first-page":"585","DOI":"10.3109\/00016489.2010.544327","volume":"131","author":"S Helbig","year":"2011","unstructured":"Helbig S, Van de Heyning P, Kiefer J, Baumann U, Kleine-Punte A, Brockmeier H, Anderson I, Gstoettner W (2011) Combined electric acoustic stimulation with the PULSARCI100 implant system using the FLEXEAS electrode array. Acta Otolaryngol. 131(6):585\u2013595. https:\/\/doi.org\/10.3109\/00016489.2010.544327","journal-title":"Acta Otolaryngol."},{"issue":"1-2","key":"785_CR23","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/0378-5955(95)00162-6","volume":"90","author":"KR Henry","year":"1995","unstructured":"Henry KR (1995) Auditory nerve neurophonic recorded from the round window of the Mongolian gerbil. Hear Res. 90(1-2):176\u2013184. https:\/\/doi.org\/10.1016\/0378-5955(95)00162-6","journal-title":"Hear Res."},{"key":"785_CR24","doi-asserted-by":"publisher","unstructured":"Kim JS, Tejani VD, Abbas PJ, Brown CJ (2018) Postoperative electrocochleography from hybrid cochlear implant users: an alternative analysis procedure. Hear Res. 370:304\u2013315. https:\/\/doi.org\/10.1016\/j.heares.2018.10.016","DOI":"10.1016\/j.heares.2018.10.016"},{"key":"785_CR25","doi-asserted-by":"publisher","unstructured":"Koka K, Saoji AA, Litvak LM (2017) Electrocochleography in cochlear implant recipients with residual hearing: comparison with audiometric thresholds. Ear Hear. 38(3):e161\u2013e167. https:\/\/doi.org\/10.1097\/AUD.0000000000000385","DOI":"10.1097\/AUD.0000000000000385"},{"key":"785_CR26","doi-asserted-by":"publisher","unstructured":"Kopelovich JC, Reiss LA, Etler CP, Xu L, Bertroche JT, Gantz BJ, Hansen MR (2015) Hearing loss after activation of hearing preservation cochlear implants might be related to afferent cochlear innervation injury. Otol Neurotol. 36(6):1035\u20131044. https:\/\/doi.org\/10.1097\/MAO.0000000000000754","DOI":"10.1097\/MAO.0000000000000754"},{"key":"785_CR27","doi-asserted-by":"publisher","unstructured":"Landsberger DM, Svrakic M, Roland JT Jr, Svirsky M (2015) The relationship between insertion angles, default frequency allocations, and spiral ganglion place pitch in cochlear implants. Ear Hear. 36(5):e207\u2013e213. https:\/\/doi.org\/10.1097\/AUD.0000000000000163","DOI":"10.1097\/AUD.0000000000000163"},{"key":"785_CR28","doi-asserted-by":"publisher","unstructured":"Lenarz T, Stover T, Buechner A, Paasche G, Briggs R, Risi F, Pesch J, Battmer RD (2006) Temporal bone results and hearing preservation with a new straight electrode. Audiol. Neuro. Otol. 11 (Suppl. 1), 34e41. https:\/\/doi.org\/10.1159\/000095612","DOI":"10.1159\/000095612"},{"issue":"12","key":"785_CR29","doi-asserted-by":"publisher","first-page":"838","DOI":"10.3109\/14992027.2013.802032","volume":"52","author":"T Lenarz","year":"2013","unstructured":"Lenarz T, James C, Cuda D, Fitzgerald O'Connor A, Frachet B, Frijns JH, Klenzner T, Laszig R, Manrique M, Marx M, Merkus P, Mylanus EA, Offeciers E, Pesch J, Ramos-Macias A, Robier A, Sterkers O, Uziel A (2013) European multi-centre study of the Nucleus Hybrid L24 cochlear implant. Int J Audiol. 52(12):838\u2013848. https:\/\/doi.org\/10.3109\/14992027.2013.802032","journal-title":"Int J Audiol."},{"issue":"6","key":"785_CR30","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1002\/cne.24802","volume":"528","author":"Q Li","year":"2020","unstructured":"Li Q, Lu T, Zhang C, Hansen MR, Li S (2020) Electrical stimulation induces synaptic changes in the peripheral auditory system. J Comp Neurol. 528(6):893\u2013905. https:\/\/doi.org\/10.1002\/cne.24802","journal-title":"J Comp Neurol."},{"issue":"1","key":"785_CR31","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1097\/AUD.0b013e31825f9bd3","volume":"34","author":"JT Lichtenhan","year":"2013","unstructured":"Lichtenhan JT, Cooper NP, Guinan JJ Jr (2013) A new auditory threshold estimation technique for low frequencies: Proof of concept. Ear Hear. 34(1):42\u201351. https:\/\/doi.org\/10.1097\/AUD.0b013e31825f9bd3","journal-title":"Ear Hear."},{"key":"785_CR32","doi-asserted-by":"publisher","unstructured":"Mouney DF, Berlin CI, Cullen JK Jr, Hughes LF (1978) Changes in human eighth nerve action potential as a function of stimulation rate. Arch Otolaryngol. 104(10):551\u2013554. https:\/\/doi.org\/10.1001\/archotol.1978.00790100005001","DOI":"10.1001\/archotol.1978.00790100005001"},{"key":"785_CR33","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.heares.2013.01.012","volume":"298","author":"SJ O'Leary","year":"2013","unstructured":"O'Leary SJ, Monksfield P, Kel G, Connolly T, Souter MA, Chang A, Marovic P, O'Leary JS, Richardson R, Eastwood H (2013) Relations between cochlear histopathology and hearing loss in experimental cochlear implantation. Hear Res. 298:27\u201335. https:\/\/doi.org\/10.1016\/j.heares.2013.01.012","journal-title":"Hear Res."},{"issue":"6","key":"785_CR34","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1152\/jn.00006.2019","volume":"121","author":"AK Pappa","year":"2019","unstructured":"Pappa AK, Hutson KA, Scott WC, Wilson JD, Fox KE, Masood MM, Giardina CK, Pulver SH, Grana GD, Askew C, Fitzpatrick DC (2019) Hair cell and neural contributions to the cochlear summating potential. J Neurophysiol. 121(6):2163\u20132180. https:\/\/doi.org\/10.1152\/jn.00006.2019","journal-title":"J Neurophysiol."},{"key":"785_CR35","doi-asserted-by":"publisher","unstructured":"Pillsbury HC 3rd, Dillon MT, Buchman CA, Staecker H, Prentiss SM, Ruckenstein MJ, Bigelow DC, Telischi FF, Martinez DM, Runge CL, Friedland DR, Blevins NH, Larky JB, Alexiades G, Kaylie DM, Roland PS, Miyamoto RT, Backous DD, Warren FM, El-Kashlan HK, Slager HK, Reyes C, Racey AI, Adunka OF (2018) Multicenter US clinical trial with an Electric-Acoustic Stimulation (EAS) system in adults: final outcomes. Otol Neurotol. 39(3):299\u2013305. https:\/\/doi.org\/10.1097\/MAO.0000000000001691","DOI":"10.1097\/MAO.0000000000001691"},{"key":"785_CR36","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.heares.2015.08.018","volume":"333","author":"AM Quesnel","year":"2016","unstructured":"Quesnel AM, Nakajima HH, Rosowski JJ, Hansen MR, Gantz BJ, Nadol JB Jr (2016) Delayed loss of hearing after hearing preservation cochlear implantation: Human temporal bone pathology and implications for etiology. Hear Res. 333:225\u2013234. https:\/\/doi.org\/10.1016\/j.heares.2015.08.018","journal-title":"Hear Res."},{"issue":"20","key":"785_CR37","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1001\/jama.2011.679","volume":"305","author":"SD Rauch","year":"2011","unstructured":"Rauch SD, Halpin CF, Antonelli PJ, Babu S, Carey JP, Gantz BJ, Goebel JA, Hammerschlag PE, Harris JP, Isaacson B, Lee D, Linstrom CJ, Parnes LS, Shi H, Slattery WH, Telian SA, Vrabec JT, Reda DJ (2011) Oral vs intratympanic corticosteroid therapy for idiopathic sudden sensorineural hearing loss: a randomized trial. JAMA. 305(20):2071\u20132079. https:\/\/doi.org\/10.1001\/jama.2011.679","journal-title":"JAMA."},{"key":"785_CR38","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.heares.2015.06.007","volume":"327","author":"LA Reiss","year":"2015","unstructured":"Reiss LA, Stark G, Nguyen-Huynh AT, Spear KA, Zhang H, Tanaka C, Li H (2015) Morphological correlates of hearing loss after cochlear implantation and electro-acoustic stimulation in a hearing-impaired Guinea pig model. Hear Res. 327:163\u2013174. https:\/\/doi.org\/10.1016\/j.heares.2015.06.007","journal-title":"Hear Res."},{"issue":"1","key":"785_CR39","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1002\/lary.25451","volume":"126","author":"JT Roland Jr","year":"2016","unstructured":"Roland JT Jr, Gantz BJ, Waltzman SB, Parkinson AJ, Multicenter Clinical Trial Group (2016) United States multicenter clinical trial of the cochlear nucleus hybrid implant system. Laryngoscope. 126(1):175\u2013181. https:\/\/doi.org\/10.1002\/lary.25451","journal-title":"Laryngoscope."},{"issue":"8","key":"785_CR40","doi-asserted-by":"publisher","first-page":"1939","DOI":"10.1002\/lary.27073","volume":"128","author":"JT Roland Jr","year":"2018","unstructured":"Roland JT Jr, Gantz BJ, Waltzman SB, Parkinson AJ (2018) Long-term outcomes of cochlear implantation in patients with high-frequency hearing loss. Laryngoscope. 128(8):1939\u20131945. https:\/\/doi.org\/10.1002\/lary.27073","journal-title":"Laryngoscope."},{"key":"785_CR41","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.heares.2017.04.005","volume":"350","author":"RA Scheperle","year":"2017","unstructured":"Scheperle RA, Tejani VD, Omtvedt JK, Brown CJ, Abbas PJ, Hansen MR, Gantz BJ, Oleson JJ, Ozanne MV (2017) Delayed changes in auditory status in cochlear implant users with preserved acoustic hearing. Hear Res. 350:45\u201357. https:\/\/doi.org\/10.1016\/j.heares.2017.04.005","journal-title":"Hear Res."},{"issue":"2","key":"785_CR42","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1007\/s10162-007-0076-9","volume":"8","author":"O Stakhovskaya","year":"2007","unstructured":"Stakhovskaya O, Sridhar D, Bonham BH, Leake PA (2007) Frequency map for the human cochlear spiral ganglion: implications for cochlear implants. J Assoc Res Otolaryngol. 8(2):220\u2013233. https:\/\/doi.org\/10.1007\/s10162-007-0076-9","journal-title":"J Assoc Res Otolaryngol."},{"key":"785_CR43","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.heares.2014.07.011","volume":"316","author":"C Tanaka","year":"2014","unstructured":"Tanaka C, Nguyen-Huynh A, Loera K, Stark G, Reiss L (2014) Factors associated with hearing loss in a normal-hearing guinea pig model of Hybrid cochlear implants. Hear Res. 316:82\u201393. https:\/\/doi.org\/10.1016\/j.heares.2014.07.011","journal-title":"Hear Res."},{"key":"785_CR44","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.heares.2019.01.002","volume":"373","author":"VD Tejani","year":"2019","unstructured":"Tejani VD, Abbas PJ, Brown CJ, Woo J (2019) An improved method of obtaining electrocochleography recordings from Nucleus Hybrid cochlear implant users. Hear Res. 373:113\u2013120. https:\/\/doi.org\/10.1016\/j.heares.2019.01.002","journal-title":"Hear Res."},{"issue":"5","key":"785_CR45","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1097\/01.mao.0000185056.99888.f3","volume":"26","author":"M Tykocinski","year":"2005","unstructured":"Tykocinski M, Cohen LT, Cowan RS (2005) Measurement and analysis of access resistance and polarization impedance in cochlear implant recipients. Otol Neurotol. 26(5):948\u2013956. https:\/\/doi.org\/10.1097\/01.mao.0000185056.99888.f3","journal-title":"Otol Neurotol."},{"issue":"3","key":"785_CR46","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1097\/mao.0000000000000703","volume":"36","author":"KM Van Abel","year":"2015","unstructured":"Van Abel KM, Dunn CC, Sladen DP, Oleson JJ, Beatty CW, Neff BA, Hansen M, Gantz BJ, Driscoll CL (2015) Hearing preservation among patients undergoing cochlear implantation. Otol Neurotol 36(3):416\u2013421. https:\/\/doi.org\/10.1097\/mao.0000000000000703","journal-title":"Otol Neurotol"},{"key":"785_CR47","unstructured":"Yang H, Tejani VD, Kim J-S, Abbas PJ, Brown CJ, Woo J (2019) Localized impedance changes with delayed-onset hearing loss in hybrid cochlear implant users. in: conference on implantable auditory prostheses, lake Tahoe, CA, July 2019"}],"container-title":["Journal of the Association for Research in Otolaryngology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10162-021-00785-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10162-021-00785-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10162-021-00785-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T16:52:11Z","timestamp":1615308731000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10162-021-00785-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,4]]},"references-count":47,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,4]]}},"alternative-id":["785"],"URL":"https:\/\/doi.org\/10.1007\/s10162-021-00785-4","relation":{},"ISSN":["1525-3961","1438-7573"],"issn-type":[{"value":"1525-3961","type":"print"},{"value":"1438-7573","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,4]]},"assertion":[{"value":"14 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"BJG is a consultant for Cochlear Ltd. MRH is co-founder and Chief Medical Officer for iotaMotion, Inc. VDT is a consultant for iotaMotion, Inc. All other authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}