{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T21:37:19Z","timestamp":1782769039472,"version":"3.54.5"},"reference-count":68,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2016,11,30]],"date-time":"2016-11-30T00:00:00Z","timestamp":1480464000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomech Model Mechanobiol"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1007\/s10237-016-0857-3","type":"journal-article","created":{"date-parts":[[2016,11,30]],"date-time":"2016-11-30T05:13:46Z","timestamp":1480482826000},"page":"851-869","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["A resolved two-way coupled CFD\/6-DOF approach for predicting embolus transport and the embolus-trapping efficiency of IVC filters"],"prefix":"10.1007","volume":"16","author":[{"given":"Kenneth I.","family":"Aycock","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert L.","family":"Campbell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9029-5217","authenticated-orcid":false,"given":"Keefe B.","family":"Manning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brent A.","family":"Craven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,11,30]]},"reference":[{"key":"857_CR1","doi-asserted-by":"publisher","first-page":"055505","DOI":"10.1088\/0169-5983\/46\/5\/055505","volume":"46","author":"E Abolfazli","year":"2014","unstructured":"Abolfazli E, Fatouraee N, Vahidi B (2014) Dynamics of motion of a clot through an arterial bifurcation: a finite element analysis. Fluid Dyn Res 46:055505","journal-title":"Fluid Dyn Res"},{"issue":"01","key":"857_CR2","doi-asserted-by":"publisher","first-page":"S38","DOI":"10.1016\/j.thromres.2014.03.017","volume":"133","author":"MM Aleman","year":"2014","unstructured":"Aleman MM, Walton BL, Byrnes JR, Wolberg AS (2014) Fibrinogen and red blood cells in venous thrombosis. Thromb Res 133(01):S38\u2013S40","journal-title":"Thromb Res"},{"issue":"7","key":"857_CR3","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1016\/j.jcin.2015.12.268","volume":"9","author":"M Alkhouli","year":"2016","unstructured":"Alkhouli M, Morad M, Narins CR, Raza F, Bashir R (2016) Inferior vena cava thrombosis. JACC Cardiovasc Interv 9(7):629\u2013643","journal-title":"JACC Cardiovasc Interv"},{"issue":"7","key":"857_CR4","doi-asserted-by":"publisher","first-page":"071008","DOI":"10.1115\/1.4026498","volume":"136","author":"IR Argueta-Morales","year":"2014","unstructured":"Argueta-Morales IR, Tran R, Ceballos A, Clark WD, Osorio R, Divo EA, Kassab AJ, DeCampli WM (2014) Mathematical modeling of patient-specific ventricular assist device implantation to reduce particulate embolization rate to cerebral vessels. J Biomech Eng 136(7):071008","journal-title":"J Biomech Eng"},{"key":"857_CR5","doi-asserted-by":"publisher","unstructured":"Aycock KI, Campbell RL, Lynch FC, Manning KB, Craven BA (2016) The importance of hemorheology and patient anatomy on the hemodynamics in the inferior vena cava. Ann Biomed Eng 44(12):3568\u20133582","DOI":"10.1007\/s10439-016-1663-x"},{"key":"857_CR6","doi-asserted-by":"crossref","unstructured":"Aycock KI, Campbell RL, Manning KB, Sastry SP, Shontz SM, Lynch FC, Craven BA (2014) A computational method for predicting inferior vena cava filter performance on a patient-specific basis. J Biomech Eng 136(8):1\u201313 (Erratum, 137:1\u20132, 2015)","DOI":"10.1115\/1.4031634"},{"key":"857_CR7","unstructured":"Campbell RL (2010) Fluid\u2013structure interaction and inverse design simulations for flexible turbomachinery. PhD thesis, The Pennsylvania State University"},{"key":"857_CR8","doi-asserted-by":"publisher","first-page":"H732","DOI":"10.1152\/ajpheart.00320.2013","volume":"305","author":"IA Carr","year":"2013","unstructured":"Carr IA, Nemoto N, Schwartz RS, Shadden SC (2013) Size-dependent predilections of cardiogenic embolic transport. Am J Physiol Heart Circul Physiol 305:H732\u2013H739","journal-title":"Am J Physiol Heart Circul Physiol"},{"issue":"4","key":"857_CR9","doi-asserted-by":"publisher","first-page":"H1161-7","DOI":"10.1152\/ajpheart.00641.2002","volume":"284","author":"CP Cheng","year":"2003","unstructured":"Cheng CP, Herfkens RJ, Taylor CA (2003) Inferior vena caval hemodynamics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging. Am J Physiol Heart Circul Physiol 284(4):H1161-7","journal-title":"Am J Physiol Heart Circul Physiol"},{"issue":"9","key":"857_CR10","doi-asserted-by":"publisher","first-page":"e73485","DOI":"10.1371\/journal.pone.0073485","volume":"8","author":"HW Choi","year":"2013","unstructured":"Choi HW, Navia JA, Kassab GS (2013) Stroke propensity is increased under atrial fibrillation hemodynamics: a simulation study. PLoS ONE 8(9):e73485","journal-title":"PLoS ONE"},{"issue":"2","key":"857_CR11","first-page":"11","volume":"2","author":"J Cipolla","year":"2008","unstructured":"Cipolla J, Weger NS, Sharma R, Schrag SP, Sarani B, Truitt M, Lorenzo M, Sims CA, Kim PK, Torigian D, Temple-Lykens B, Sicoutris CP, Stawicki SP (2008) Complications of vena cava filters: a comprehensive clinical review. OPUS 12 Sci 2(2):11\u201324","journal-title":"OPUS 12 Sci"},{"issue":"3","key":"857_CR12","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1007\/s13239-015-0230-1","volume":"6","author":"WD Clark","year":"2015","unstructured":"Clark WD, Eslahpazir BA, Argueta-Morales IR, Kassab AJ, Divo EA, DeCampli WM (2015) Comparison between bench-top and computational modelling of cerebral thromboembolism in ventricular assist device circulation. Cardiovasc Eng Technol 6(3):242\u2013255","journal-title":"Cardiovasc Eng Technol"},{"key":"857_CR13","unstructured":"DCS\u00a0Computing GmbH. LIGGGHTS public documentation, version 3.1.0 (2015)"},{"issue":"3","key":"857_CR14","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/j.ces.2003.09.037","volume":"59","author":"A Renzo Di","year":"2004","unstructured":"Di Renzo A, Di Maio FP (2004) Comparison of contact-force models for the simulation of collisions in DEM-based granular flow codes. Chem Eng Sci 59(3):525\u2013541","journal-title":"Chem Eng Sci"},{"key":"857_CR15","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.oceaneng.2015.08.066","volume":"110","author":"AJ Dunbar","year":"2015","unstructured":"Dunbar AJ, Craven BA, Paterson EG (2015) Development and validation of a tightly coupled CFD\/6-DOF solver for simulating floating offshore wind turbine platforms. Ocean Eng 110:98\u2013105","journal-title":"Ocean Eng"},{"key":"857_CR16","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1007\/s10237-014-0561-0","volume":"13","author":"D Fabbri","year":"2014","unstructured":"Fabbri D, Long Q, Das S, Pinelli M (2014) Computational modelling of emboli travel trajectories in cerebral arteries: influence of microembolic particle size and density. Biomech Model Mechanobiol 13:289\u2013302","journal-title":"Biomech Model Mechanobiol"},{"key":"857_CR17","doi-asserted-by":"publisher","unstructured":"Ferreira JM, Chhabra RP (1998) Accelerating motion of a vertically falling sphere in incompressible Newtonian media: an analytical solution. Powder Technol 97(1):6\u201315","DOI":"10.1016\/S0032-5910(97)03386-X"},{"key":"857_CR18","volume-title":"Computational methods for fluid dynamics","author":"JH Ferziger","year":"2012","unstructured":"Ferziger JH, Peric M (2012) Computational methods for fluid dynamics. Springer, New York"},{"issue":"2","key":"857_CR19","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1006\/jcph.2000.6542","volume":"169","author":"R Glowinski","year":"2001","unstructured":"Glowinski R, Pan TW, Hesla TI, Joseph DD, P\u00e9riaux J (2001) A fictitious domain approach to the direct numerical simulation of incompressible viscous flow past moving rigid bodies: application to particulate flow. J Comput Phys 169(2):363\u2013426","journal-title":"J Comput Phys"},{"issue":"1","key":"857_CR20","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1080\/00221686.2010.538572","volume":"49","author":"J Guo","year":"2011","unstructured":"Guo J (2011) Motion of spheres falling through fluids. J Hydraul Res 49(1):32\u201341","journal-title":"J Hydraul Res"},{"key":"857_CR21","unstructured":"Hager A (2014) CFD-DEM on multiple scales: An extensive investigation of particle\u2013fluid interactions. PhD thesis, Technisch-Naturwissenschaftliche Fakult\u00e4t"},{"key":"857_CR22","doi-asserted-by":"publisher","unstructured":"Hager A, Kloss C, Pirker S, Goniva C (2014) Parallel resolved open source CFD-DEM: method, validation and application. J Comput Multiph Flows 6(1):13\u201327","DOI":"10.1260\/1757-482X.6.1.13"},{"issue":"6","key":"857_CR23","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/S1051-0443(94)71627-4","volume":"5","author":"FD Hammer","year":"1994","unstructured":"Hammer FD, Rousseau HP, Joffre FG, Sentenac BP, Tran-Van T, Barthelemy RP (1994) In vitro evaluation of vena cava filters. J Vasc Interv Radiol 5(6):869\u2013876","journal-title":"J Vasc Interv Radiol"},{"key":"857_CR24","first-page":"55","volume":"1","author":"AC Hindmarsh","year":"1983","unstructured":"Hindmarsh AC (1983) ODEPACK, a systematized collection of ODE solvers. IMACS Trans Sci Comput 1:55\u201364","journal-title":"IMACS Trans Sci Comput"},{"key":"857_CR25","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/0021-9991(90)90227-R","volume":"87","author":"DB Ingham","year":"1990","unstructured":"Ingham DB, Tang T (1990) A numerical investigation into the steady flow past a rotating cylinder at low and intermediate Reynolds numbers. J Comput Phys 87:91\u2013107","journal-title":"J Comput Phys"},{"issue":"2","key":"857_CR26","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/S1051-0443(98)70272-6","volume":"9","author":"HJ Jaeger","year":"1998","unstructured":"Jaeger HJ, Kolb S, Mair T, Geller M, Christmann A, Kinne RKH, Mathias KD (1998) In vitro model for the evaluation of inferior vena cava filters: effect of experimental parameters on thrombus-capturing efficacy of the Vena Tech-LGM filter. J Vasc Interv Radiol 9(2):295\u2013304","journal-title":"J Vasc Interv Radiol"},{"issue":"04","key":"857_CR27","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1017\/S002211206500109X","volume":"22","author":"KOLF Jayaweera","year":"1965","unstructured":"Jayaweera KOLF, Mason BJ (1965) The behaviour of freely falling cylinders and cones in a viscous fluid. J Fluid Mech 22(04):709","journal-title":"J Fluid Mech"},{"issue":"2","key":"857_CR28","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1148\/radiology.166.2.3336712","volume":"166","author":"AA Katsamouris","year":"1988","unstructured":"Katsamouris AA, Waltman AC, Delichatsios MA, Athanasoulis CA (1988) Inferior vena cava filters: in vitro comparison of clot trapping and flow dynamics. Radiology 166(2):361\u2013366","journal-title":"Radiology"},{"key":"857_CR29","doi-asserted-by":"publisher","unstructured":"Khodaee F, Vahidi B, Fatouraee N (2016) Analysis of mechanical parameters on the thromboembolism using a patient-specific computational model. Biomech Model Mechanobiol 15(5):1295\u20131305","DOI":"10.1007\/s10237-016-0762-9"},{"key":"857_CR30","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1504\/PCFD.2012.047457","volume":"12","author":"C Kloss","year":"2012","unstructured":"Kloss C, Goniva C, Hager A, Amberger S, Pirker S (2012) Models, algorithms and validation for opensource DEM and CFD-DEM. PCFD 12:140\u2013152","journal-title":"PCFD"},{"issue":"3","key":"857_CR31","doi-asserted-by":"publisher","first-page":"839","DOI":"10.2214\/AJR.06.5035","volume":"188","author":"RS Kuzo","year":"2007","unstructured":"Kuzo RS, Pooley RA, Crook JE, Heckman MG, Gerber TC (2007) Measurement of caval blood flow with MRI during respiratory maneuvers: implications for vascular contrast opacification on pulmonary CT angiographic studies. Am J Roentgenol 188(3):839\u2013842","journal-title":"Am J Roentgenol"},{"issue":"5","key":"857_CR32","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1007\/s00270-015-1077-4","volume":"38","author":"A Laborda","year":"2015","unstructured":"Laborda A, Kuo WT, Ioakeim I, De Blas I, Malv\u00e8 M, Lahuerta C, De Gregorio MA (2015) Respiratory-induced haemodynamic changes: a contributing factor to IVC filter penetration. Cardiovasc Interv Radiol 38(5):1192\u20131197","journal-title":"Cardiovasc Interv Radiol"},{"issue":"1","key":"857_CR33","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1093\/imammb\/dqq005","volume":"28","author":"K Leiderman","year":"2011","unstructured":"Leiderman K, Fogelson AL (2011) Grow with the flow: a spatial-temporal model of platelet deposition and blood coagulation under flow. Math Med Biol 28(1):47\u201384","journal-title":"Math Med Biol"},{"issue":"16","key":"857_CR34","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1001\/jama.2015.3780","volume":"313","author":"P Mismetti","year":"2015","unstructured":"Mismetti P, Laporte S, Pellerin O, Ennezat P-V, Couturaud F, Elias A, Falvo N, Meneveau N, Quere I, Roy P-M, Sanchez O, Schmidt J, Seinturier C, Sevestre M-A, Beregi J-P, Tardy B, Lacroix P, Presles E, Leizorovicz A, Decousus H, Barral F-G, Meyer G (2015) Effect of a retrievable inferior vena cava filter plus anticoagulation vs anticoagulation alone on risk of recurrent pulmonary embolism. JAMA 313(16):1627","journal-title":"JAMA"},{"issue":"1","key":"857_CR35","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1146\/annurev.fluid.37.061903.175743","volume":"37","author":"R Mittal","year":"2005","unstructured":"Mittal R, Iaccarino G (2005) Immersed boundary methods. Annu Rev Fluid Mech 37(1):239\u2013261","journal-title":"Annu Rev Fluid Mech"},{"issue":"1","key":"857_CR36","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00162-015-0359-4","volume":"30","author":"D Mukherjee","year":"2016","unstructured":"Mukherjee D, Padilla J, Shadden SC (2016) Numerical investigation of fluid\u2013particle interactions for embolic stroke. Theor Comput Fluid Dyn 30(1):23\u201329","journal-title":"Theor Comput Fluid Dyn"},{"issue":"6","key":"857_CR37","doi-asserted-by":"publisher","first-page":"3766","DOI":"10.1121\/1.2201251","volume":"119","author":"V Nahirnyak","year":"2006","unstructured":"Nahirnyak V, Yoon SW, Holland CK (2006) Acousto-mechanical and thermal properties of clotted blood. J Acoust Soc Am 119(6):3766\u20133772","journal-title":"J Acoust Soc Am"},{"issue":"8","key":"857_CR38","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1002\/(SICI)1097-0258(19980430)17:8<857::AID-SIM777>3.0.CO;2-E","volume":"17","author":"RG Newcombe","year":"1998","unstructured":"Newcombe RG (1998) Two-sided confidence intervals for the single proportion: comparison of seven methods. Stat Med 17(8):857\u2013872","journal-title":"Stat Med"},{"key":"857_CR39","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1016\/j.jbiomech.2014.11.047","volume":"48","author":"M Nicol\u00e1s","year":"2015","unstructured":"Nicol\u00e1s M, Malv\u00e8 M, Pe\u00f1a E, Mart\u00ednez MA, Leask R (2015) In vitro comparison of G\u00fcnther Tulip and Celect filters: testing filtering efficiency and pressure drop. J Biomech 48:504\u2013511","journal-title":"J Biomech"},{"key":"857_CR40","unstructured":"OpenCFD Ltd. User guide, OpenFOAM version 2.3.x (2014)"},{"issue":"6","key":"857_CR41","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1080\/10255842.2011.629616","volume":"16","author":"AF Osorio","year":"2011","unstructured":"Osorio AF, Osorio R, Ceballos A, Tran R, Clark WD, Divo EA, Argueta-Morales IR, Kassab AJ, DeCampli WM (2011) Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk. Comput Methods Biomech Biomed Eng 16(6):622\u2013638","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"12","key":"857_CR42","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1016\/j.crme.2005.10.006","volume":"333","author":"RW Pan","year":"2005","unstructured":"Pan RW, Glowinski R (2005) Direct simulation of the motion of neutrally buoyant balls in a three-dimensional Poiseuille flow. C R Mec 333(12):884\u2013895","journal-title":"C R Mec"},{"key":"857_CR43","first-page":"2825","volume":"12","author":"F Pedregosa","year":"2012","unstructured":"Pedregosa F, Varoquaux G, Gramfort A, Michel V, Thirion B, Grisel O, Blondel M, Prettenhofer P, Weiss R, Dubourg V, Vanderplas J, Passos A, Cournapeau D, Brucher M, Perrot M, Duchesnay \u00c9 (2012) Scikit-learn: machine learning in Python. J Mach Learn Res 12:2825\u20132830","journal-title":"J Mach Learn Res"},{"issue":"2","key":"857_CR44","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/0021-9991(72)90065-4","volume":"10","author":"CS Peskin","year":"1972","unstructured":"Peskin CS (1972) Flow patterns around heart valves: a numerical method. J Comput Phys 10(2):252\u2013271","journal-title":"J Comput Phys"},{"issue":"1","key":"857_CR45","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/0021-9991(80)90007-8","volume":"37","author":"CS Peskin","year":"1980","unstructured":"Peskin CS, McQueen DM (1980) Modeling prosthetic heart valves for numerical analysis of blood flow in the heart. J Comput Phys 37(1):113\u2013132","journal-title":"J Comput Phys"},{"issue":"1","key":"857_CR46","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1006\/jcph.1995.1039","volume":"117","author":"S Plimpton","year":"1995","unstructured":"Plimpton S (1995) Fast parallel algorithms for short-range molecular dynamics. J Comput Phys 117(1):1\u201319","journal-title":"J Comput Phys"},{"key":"857_CR47","doi-asserted-by":"publisher","unstructured":"PREPIC Study Group (2005) Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism: the PREPIC (prevention du risque d\u2019embolie pulmonaire par interruption cave) randomized study. Circulation 112(3):416\u2013422","DOI":"10.1161\/CIRCULATIONAHA.104.512834"},{"issue":"6","key":"857_CR48","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1016\/j.jvir.2010.12.024","volume":"22","author":"E Rahbar","year":"2011","unstructured":"Rahbar E, Mori D, Moore JE (2011) Three-dimensional analysis of flow disturbances caused by clots in inferior vena cava filters. J Vasc Interv Radiol 22(6):835\u2013842","journal-title":"J Vasc Interv Radiol"},{"issue":"3","key":"857_CR49","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1007\/s11517-012-0867-y","volume":"50","author":"Z Ren","year":"2012","unstructured":"Ren Z, Wang SL, Singer MA (2012) Modeling hemodynamics in an unoccluded and partially occluded inferior vena cava under rest and exercise conditions. Med Biol Eng Comput 50(3):277\u2013287","journal-title":"Med Biol Eng Comput"},{"key":"857_CR50","first-page":"49","volume":"6","author":"RA Robinson","year":"2013","unstructured":"Robinson RA, Herbertson LH, Sarkar Das S, Malinauskas RA, Pritchard WF, Grossman LW (2013) Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters. Med Devices (Auckl.) 6:49\u201357","journal-title":"Med Devices (Auckl.)"},{"issue":"4760","key":"857_CR51","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1038\/189209a0","volume":"189","author":"G Segr\u00e9","year":"1961","unstructured":"Segr\u00e9 G, Silberberg A (1961) Radial particle displacements in Poiseuille flow of suspensions. Nature 189(4760):209\u2013210","journal-title":"Nature"},{"issue":"7","key":"857_CR52","doi-asserted-by":"publisher","first-page":"2366","DOI":"10.1016\/j.jcp.2008.12.006","volume":"228","author":"AA Shirgaonkar","year":"2009","unstructured":"Shirgaonkar AA, MacIver MA, Patankar NA (2009) A new mathematical formulation and fast algorithm for fully resolved simulation of self-propulsion. J Comput Phys 228(7):2366\u20132390","journal-title":"J Comput Phys"},{"key":"857_CR53","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1001\/archinte.158.6.585","volume":"158","author":"MD Silverstein","year":"1998","unstructured":"Silverstein MD, Heit JA, Mohr DN, Petterson TM, O\u2019Fallon WM, Melton J (1998) Trends in the incidence of deep vein thrombosis and pulmonary embolism. Arch Intern Med 158:585\u2013593","journal-title":"Arch Intern Med"},{"issue":"6","key":"857_CR54","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.jvir.2009.02.015","volume":"20","author":"MA Singer","year":"2009","unstructured":"Singer MA, Henshaw WD, Wang SL (2009) Computational modeling of blood flow in the TrapEase inferior vena cava filter. J Vasc Interv Radiol 20(6):799\u2013805","journal-title":"J Vasc Interv Radiol"},{"issue":"10","key":"857_CR55","doi-asserted-by":"publisher","first-page":"101006","DOI":"10.1115\/1.4002488","volume":"132","author":"MA Singer","year":"2010","unstructured":"Singer MA, Wang SL, Diachin DP (2010) Design optimization of vena cava filters: an application to dual filtration devices. J Biomech Eng 132(10):101006 1\u201310","journal-title":"J Biomech Eng"},{"issue":"2","key":"857_CR56","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.jvir.2010.09.032","volume":"22","author":"MA Singer","year":"2011","unstructured":"Singer MA, Wang SL (2011) Modeling blood flow in a tilted inferior vena cava filter: does tilt adversely affect hemodynamics? J Vasc Interv Radiol 22(2):229\u2013235","journal-title":"J Vasc Interv Radiol"},{"issue":"11","key":"857_CR57","doi-asserted-by":"publisher","first-page":"1764","DOI":"10.1007\/s10439-008-9560-6","volume":"36","author":"SFC Stewart","year":"2008","unstructured":"Stewart SFC, Robinson RA, Nelson RA, Malinauskas RA (2008) Effects of thrombosed vena cava filters on blood flow: flow visualization and numerical modeling. Ann Biomed Eng 36(11):1764\u20131781","journal-title":"Ann Biomed Eng"},{"issue":"5","key":"857_CR58","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1016\/S1051-0443(95)71175-7","volume":"6","author":"GW Stoneham","year":"1995","unstructured":"Stoneham GW, Burbridge BE, Millward SF (1995) Temporary inferior vena cava filters: in vitro comparison with permanent IVC filters. J Vasc Interv Radiol 6(5):731\u2013736","journal-title":"J Vasc Interv Radiol"},{"issue":"3","key":"857_CR59","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1115\/1.2187034","volume":"128","author":"TN Swaminathan","year":"2006","unstructured":"Swaminathan TN, Hu HH, Patel AA (2006) Numerical analysis of the hemodynamics and embolus capture of a Greenfield vena cava filter. J Biomech Eng 128(3):360\u2013370","journal-title":"J Biomech Eng"},{"key":"857_CR60","doi-asserted-by":"publisher","unstructured":"Taylor JO, Meyer RS, Deutsch S, Manning KB (2016) Development of a computational model for macroscopic predictions of device-induced thrombosis. Biomech Model Mechanobiol 15(6):1713\u20131731","DOI":"10.1007\/s10237-016-0793-2"},{"issue":"11","key":"857_CR61","doi-asserted-by":"publisher","first-page":"1514","DOI":"10.1016\/j.jvir.2011.08.006","volume":"22","author":"TKB Teo","year":"2011","unstructured":"Teo TKB, Angle JF, Shipp JI, Bluett MK, Gilliland CA, Turba UC, Matsumoto AH (2011) Incidence and management of inferior vena cava filter thrombus detected at time of filter retrieval. J Vasc Interv Radiol 22(11):1514\u20131520","journal-title":"J Vasc Interv Radiol"},{"issue":"04","key":"857_CR62","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1017\/S0022112059000829","volume":"6","author":"DJ Tritton","year":"1959","unstructured":"Tritton DJ (1959) Experiments on the flow past a circular cylinder at low Reynolds numbers. J Fluid Mech 6(04):547\u2013567","journal-title":"J Fluid Mech"},{"issue":"7","key":"857_CR63","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1016\/j.jbiomech.2012.01.020","volume":"45","author":"B Vahidi","year":"2012","unstructured":"Vahidi B, Fatouraee N (2012) Large deforming buoyant embolus passing through a stenotic common carotid artery: a computational simulation. J Biomech 45(7):1312\u20131322","journal-title":"J Biomech"},{"issue":"3","key":"857_CR64","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1016\/j.jvir.2009.11.013","volume":"21","author":"SL Wang","year":"2010","unstructured":"Wang SL, Singer MA (2010) Toward an optimal position for inferior vena cava filters: computational modeling of the impact of renal vein inflow with Celect and TrapEase filters. J Vasc Interv Radiol 21(3):367\u2013374","journal-title":"J Vasc Interv Radiol"},{"issue":"6","key":"857_CR65","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1016\/S1051-0443(95)71208-8","volume":"6","author":"ZY Xian","year":"1995","unstructured":"Xian ZY, Roy S, Hosaka J, Kvernebo K, Laerum F (1995) Multiple emboli and filter function: an in vitro comparison of three vena cava filters. J Vasc Interv Radiol 6(6):887\u2013893","journal-title":"J Vasc Interv Radiol"},{"key":"857_CR66","unstructured":"Zhang Y (2013) Flow past a sphere and a prolate spheroid at low Reynolds numbers. Masters, Texas A&M University"},{"issue":"4","key":"857_CR67","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1007\/s12195-014-0356-5","volume":"7","author":"P Zhang","year":"2014","unstructured":"Zhang P, Gao C, Zhang N, Slepian MJ, Deng Y, Bluestein D (2014) Multiscale particle-based modeling of flowing platelets in blood plasma using dissipative particle dynamics and coarse grained molecular dynamics. Cell Mol Bioeng 7(4):552\u2013574","journal-title":"Cell Mol Bioeng"},{"issue":"284","key":"857_CR68","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1016\/j.jcp.2015.01.004","volume":"1","author":"P Zhang","year":"2015","unstructured":"Zhang P, Zhang N, Deng Y, Bluestein D (2015) A multiple time stepping algorithm for efficient multiscale modeling of platelets flowing in blood plasma. J Comput Phys 1(284):668\u2013686","journal-title":"J Comput Phys"}],"container-title":["Biomechanics and Modeling in Mechanobiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10237-016-0857-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-016-0857-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-016-0857-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,15]],"date-time":"2019-09-15T23:18:31Z","timestamp":1568589511000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10237-016-0857-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,11,30]]},"references-count":68,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["857"],"URL":"https:\/\/doi.org\/10.1007\/s10237-016-0857-3","relation":{},"ISSN":["1617-7959","1617-7940"],"issn-type":[{"value":"1617-7959","type":"print"},{"value":"1617-7940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,11,30]]}}}