{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T04:21:37Z","timestamp":1790050897905,"version":"4.0.1"},"reference-count":65,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2017,11,24]],"date-time":"2017-11-24T00:00:00Z","timestamp":1511481600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomech Model Mechanobiol"],"published-print":{"date-parts":[[2018,4]]},"DOI":"10.1007\/s10237-017-0974-7","type":"journal-article","created":{"date-parts":[[2017,11,24]],"date-time":"2017-11-24T11:36:13Z","timestamp":1511523373000},"page":"499-516","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model"],"prefix":"10.1007","volume":"17","author":[{"given":"Donnacha J.","family":"McGrath","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anja Lena","family":"Thiebes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian G.","family":"Cornelissen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barry","family":"O\u2019Brien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Jockenhoevel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Bruzzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter E.","family":"McHugh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,11,24]]},"reference":[{"key":"974_CR1","doi-asserted-by":"publisher","first-page":"4560","DOI":"10.1118\/1.3471020","volume":"37","author":"A Al-Mayah","year":"2010","unstructured":"Al-Mayah A, Moseley J, Velec M et al (2010) Deformable image registration of heterogeneous human lung incorporating the bronchial tree. Med Phys 37:4560\u20134571. \n                        https:\/\/doi.org\/10.1118\/1.3471020","journal-title":"Med Phys"},{"key":"974_CR2","doi-asserted-by":"publisher","first-page":"4701","DOI":"10.1088\/0031-9155\/56\/15\/005","volume":"56","author":"A Al-Mayah","year":"2011","unstructured":"Al-Mayah A, Moseley J, Velec M, Brock K (2011) Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy. Phys Med Biol 56:4701\u201313. \n                        https:\/\/doi.org\/10.1088\/0031-9155\/56\/15\/005","journal-title":"Phys Med Biol"},{"issue":"3","key":"974_CR3","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/S0045-7825(96)01232-7","volume":"146","author":"F Auricchio","year":"1997","unstructured":"Auricchio F, Taylor R, Lubliner J (1997) Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior. Comput methods Appl 146(3):281\u2013312","journal-title":"Comput methods Appl"},{"key":"974_CR4","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1111\/j.1439-0531.2012.02056.x","volume":"47","author":"A B\u00e4hr","year":"2012","unstructured":"B\u00e4hr A, Wolf E (2012) Domestic animal models for biomedical research. Reprod Domest Anim 47:59\u201371. \n                        https:\/\/doi.org\/10.1111\/j.1439-0531.2012.02056.x","journal-title":"Reprod Domest Anim"},{"key":"974_CR5","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.cam.2012.10.034","volume":"246","author":"J Bols","year":"2013","unstructured":"Bols J, Degroote J, Trachet B et al (2013) A computational method to assess the in vivo stresses and unloaded configuration of patient-specific blood vessels. J Comput Appl Math 246:10\u201317. \n                        https:\/\/doi.org\/10.1016\/j.cam.2012.10.034","journal-title":"J Comput Appl Math"},{"key":"974_CR6","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/j.ijrobp.2009.06.031","volume":"76","author":"KK Brock","year":"2010","unstructured":"Brock KK (2010) Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS). Int J Radiat Oncol Biol Phys 76:583\u2013596. \n                        https:\/\/doi.org\/10.1016\/j.ijrobp.2009.06.031","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"974_CR7","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1177\/000348940211100401","volume":"111","author":"AR Burningham","year":"2002","unstructured":"Burningham AR, Wax MK, Andersen PE et al (2002) Metallic tracheal stents: complications associated with long-term use in the upper airway. Ann Otol Rhinol Laryngol 111:285\u201390","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"974_CR8","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1007\/s10439-015-1504-3","volume":"44","author":"J Chaure","year":"2016","unstructured":"Chaure J, Serrano C, Fern\u00e1ndez-Parra R et al (2016) On studying the interaction between different stent models and rabbit tracheal tissue: numerical, endoscopic and histological comparison. Ann Biomed Eng 44:368\u2013381. \n                        https:\/\/doi.org\/10.1007\/s10439-015-1504-3","journal-title":"Ann Biomed Eng"},{"key":"974_CR9","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.ijpharm.2016.06.047","volume":"514","author":"W Chen","year":"2016","unstructured":"Chen W, Clauser J, Thiebes AL et al (2016) Selection and fabrication of a non-woven polycarbonate urethane cover for a tissue engineered airway stent. Int J Pharm 514:255\u2013262. \n                        https:\/\/doi.org\/10.1016\/j.ijpharm.2016.06.047","journal-title":"Int J Pharm"},{"key":"974_CR10","doi-asserted-by":"publisher","first-page":"1328","DOI":"10.1016\/j.jtcvs.2008.05.039","volume":"136","author":"FT Chung","year":"2008","unstructured":"Chung FT, Lin SM, Chen HC et al (2008) Factors leading to tracheobronchial self-expandable metallic stent fracture. J Thorac Cardiovasc Surg 136:1328\u20131335. \n                        https:\/\/doi.org\/10.1016\/j.jtcvs.2008.05.039","journal-title":"J Thorac Cardiovasc Surg"},{"key":"974_CR11","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/1749-8090-6-46","volume":"6","author":"F-T Chung","year":"2011","unstructured":"Chung F-T, Chen H-C, Chou C-L et al (2011) An outcome analysis of self-expandable metallic stents in central airway obstruction: a cohort study. J Cardiothorac Surg 6:46. \n                        https:\/\/doi.org\/10.1186\/1749-8090-6-46","journal-title":"J Cardiothorac Surg"},{"key":"974_CR12","doi-asserted-by":"crossref","first-page":"2627","DOI":"10.1152\/jappl.1994.76.6.2627","volume":"76","author":"SL Codd","year":"1994","unstructured":"Codd SL, Lambert RK, Alley MR, Pack RJ (1994) Tensile stiffness of ovine tracheal wall. J Appl Physiol 76:2627\u20132635","journal-title":"J Appl Physiol"},{"key":"974_CR13","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1007\/s13239-012-0104-8","volume":"3","author":"C Conway","year":"2012","unstructured":"Conway C, Sharif F, McGarry JP, McHugh PE (2012) A computational test-bed to assess coronary stent implantation mechanics using a population-specific approach. Cardiovasc Eng Technol 3:374\u2013387. \n                        https:\/\/doi.org\/10.1007\/s13239-012-0104-8","journal-title":"Cardiovasc Eng Technol"},{"key":"974_CR14","doi-asserted-by":"publisher","first-page":"2477","DOI":"10.1016\/j.jbiomech.2013.07.010","volume":"46","author":"S Bock De","year":"2013","unstructured":"De Bock S, Iannaccone F, De Beule M et al (2013) Filling the void: a coalescent numerical and experimental technique to determine aortic stent graft mechanics. J Biomech 46:2477\u201382. \n                        https:\/\/doi.org\/10.1016\/j.jbiomech.2013.07.010","journal-title":"J Biomech"},{"key":"974_CR15","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1159\/000203364","volume":"77","author":"C Dooms","year":"2009","unstructured":"Dooms C, De Keukeleire T, Janssens A, Carron K (2009) Performance of fully covered self-expanding metallic stents in benign airway strictures. Respiration 77:420\u20136. \n                        https:\/\/doi.org\/10.1159\/000203364","journal-title":"Respiration"},{"key":"974_CR16","doi-asserted-by":"publisher","DOI":"10.2312\/VCBM\/VCBM08\/069-076","author":"J Ehrhardt","year":"2008","unstructured":"Ehrhardt J, Werner R, Schmidt-Richberg A et al (2008) Generation of a mean motion model of the lung using 4D-CT Image Data. Eurographics Workshop Vis Comput Biomed. \n                        https:\/\/doi.org\/10.2312\/VCBM\/VCBM08\/069-076","journal-title":"Eurographics Workshop Vis Comput Biomed"},{"key":"974_CR17","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1109\/TMI.2010.2076299","volume":"30","author":"J Ehrhardt","year":"2011","unstructured":"Ehrhardt J, Werner R, Schmidt-Richberg A, Handels H (2011) Statistical modeling of 4D respiratory lung motion using diffeomorphic image registration. IEEE Trans Med Imaging 30:251\u2013265. \n                        https:\/\/doi.org\/10.1109\/TMI.2010.2076299","journal-title":"IEEE Trans Med Imaging"},{"key":"974_CR18","doi-asserted-by":"publisher","unstructured":"Fern\u00e1ndez-Bussy S, Majid A, Caviedes I et al (2011) Treatment of airway complications following lung transplantation. Arch Bronconeumol (English Ed) 47:128\u2013133. \n                        https:\/\/doi.org\/10.1016\/S1579-2129(11)70031-3","DOI":"10.1016\/S1579-2129(11)70031-3"},{"key":"974_CR19","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1183\/1025448x.00991409","volume-title":"Interventional pulmonology","author":"L Freitag","year":"2010","unstructured":"Freitag L (2010) Airway stents. In: Strausz J, Bolliger CT (eds) Interventional pulmonology. European Respiratory Society Journals Ltd, Sheffield, pp 190\u2013217"},{"key":"974_CR20","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1109\/TMI.2014.2363611","volume":"34","author":"B Fuerst","year":"2015","unstructured":"Fuerst B, Mansi T, Carnis F et al (2015) Patient-specific biomechanical model for the prediction of lung motion from 4-D CT images. IEEE Trans Med Imaging 34:599\u2013607. \n                        https:\/\/doi.org\/10.1109\/TMI.2014.2363611","journal-title":"IEEE Trans Med Imaging"},{"key":"974_CR21","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.jmbbm.2012.02.006","volume":"10","author":"A Garc\u00eda","year":"2012","unstructured":"Garc\u00eda A, Pe\u00f1a E, Mart\u00ednez MA (2012) Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent. J Mech Behav Biomed Mater 10:166\u201375. \n                        https:\/\/doi.org\/10.1016\/j.jmbbm.2012.02.006","journal-title":"J Mech Behav Biomed Mater"},{"key":"974_CR22","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1080\/10255842.2012.683427","volume":"17","author":"RN Ghriallais","year":"2014","unstructured":"Ghriallais RN, Bruzzi M (2014) Self-expanding stent modelling and radial force accuracy. Comput Methods Biomech Biomed Eng 17:318\u2013333. \n                        https:\/\/doi.org\/10.1080\/10255842.2012.683427","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"974_CR23","doi-asserted-by":"publisher","first-page":"1793","DOI":"10.1148\/rg.347130063","volume":"34","author":"MCB Godoy","year":"2014","unstructured":"Godoy MCB, Saldana DA, Rao PP et al (2014) Multidetector CT evaluation of airway stents: what the radiolo-gist should know. Radiographics 34:1793\u20131806. \n                        https:\/\/doi.org\/10.1148\/rg.347130063","journal-title":"Radiographics"},{"key":"974_CR24","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1378\/chest.128.2.986","volume":"128","author":"PH Grewe","year":"2005","unstructured":"Grewe PH, M\u00fcller KM, Lindstaedt M et al (2005) Reaction patterns of the tracheobronchial wall to implanted noncovered metal stents. Chest 128:986\u2013990. \n                        https:\/\/doi.org\/10.1378\/chest.128.2.986","journal-title":"Chest"},{"key":"974_CR25","doi-asserted-by":"publisher","first-page":"8049","DOI":"10.1016\/j.biomaterials.2013.07.010","volume":"34","author":"JA Grogan","year":"2013","unstructured":"Grogan JA, Leen SB, McHugh PE (2013) Optimizing the design of a bioabsorbable metal stent using computer simulation methods. Biomaterials 34:8049\u20138060. \n                        https:\/\/doi.org\/10.1016\/j.biomaterials.2013.07.010","journal-title":"Biomaterials"},{"key":"974_CR26","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1183\/16000617.00010014","volume":"24","author":"N Guibert","year":"2015","unstructured":"Guibert N, Mazieres J, Marquette CH et al (2015) Integration of interventional bronchoscopy in the management of lung cancer. Eur Respir Rev 24:378\u2013391. \n                        https:\/\/doi.org\/10.1183\/16000617.00010014","journal-title":"Eur Respir Rev"},{"key":"974_CR27","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1007\/s002709900343","volume":"22","author":"H Hautmann","year":"1999","unstructured":"Hautmann H, Rieger J, Huber RM, Pfeifer KJ (1999) Elastic deformation properties of implanted endobronchial wire stents in benign and malignant bronchial disease: a radiographic in vivo evaluation. Cardiovasc Intervent Radiol 22:103\u20138","journal-title":"Cardiovasc Intervent Radiol"},{"key":"974_CR28","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1055\/s-0030-1250667","volume":"59","author":"H-C Hu","year":"2011","unstructured":"Hu H-C, Liu Y-H, Wu Y-C et al (2011) Granulation tissue formation following Dumon airway stenting: the influence of stent diameter. Thorac Cardiovasc Surg 59:163\u2013168","journal-title":"Thorac Cardiovasc Surg"},{"key":"974_CR29","doi-asserted-by":"crossref","first-page":"1162","DOI":"10.1152\/jappl.1984.56.5.1162","volume":"56","author":"AN Hurewitz","year":"1984","unstructured":"Hurewitz AN, Sidhu U, Bergofsky EH, Chanana AD (1984) How alterations in pleural pressure influence esophageal pressure. J Appl Physiol 56:1162\u20131169","journal-title":"J Appl Physiol"},{"key":"974_CR30","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.jtcvs.2012.03.077","volume":"144","author":"BH Jeong","year":"2012","unstructured":"Jeong BH, Um SW, Suh GY et al (2012) Results of interventional bronchoscopy in the management of postoperative tracheobronchial stenosis. J Thorac Cardiovasc Surg 144:217\u2013222. \n                        https:\/\/doi.org\/10.1016\/j.jtcvs.2012.03.077","journal-title":"J Thorac Cardiovasc Surg"},{"key":"974_CR31","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.ccm.2009.08.002","volume":"31","author":"P Lee","year":"2010","unstructured":"Lee P, Kupeli E, Mehta AC (2010) Airway stents. Clin Chest Med 31:141\u2013150. \n                        https:\/\/doi.org\/10.1016\/j.ccm.2009.08.002","journal-title":"Clin Chest Med"},{"key":"974_CR32","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1016\/j.athoracsur.2005.02.071","volume":"80","author":"A Lemaire","year":"2005","unstructured":"Lemaire A, Burfeind WR, Toloza E et al (2005) Outcomes of tracheobronchial stents in patients with malignant airway disease. Ann Thorac Surg 80:434\u2013438. \n                        https:\/\/doi.org\/10.1016\/j.athoracsur.2005.02.071","journal-title":"Ann Thorac Surg"},{"key":"974_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icheatmasstransfer.2014.02.001","volume":"53","author":"M Malv\u00e8","year":"2014","unstructured":"Malv\u00e8 M, Serrano C, Pe\u00f1a E et al (2014) Modelling the air mass transfer in a healthy and a stented rabbit trachea: CT-images, computer simulations and experimental study. Int Commun Heat Mass Transf 53:1\u20138. \n                        https:\/\/doi.org\/10.1016\/j.icheatmasstransfer.2014.02.001","journal-title":"Int Commun Heat Mass Transf"},{"key":"974_CR34","doi-asserted-by":"publisher","unstructured":"Malv\u00e8 M, Palomar Del AP, Chandra S et al (2011a) FSI analysis of a human trachea before and after prosthesis implantation. J Biomech Eng 133:71003. \n                        https:\/\/doi.org\/10.1115\/1.4004315","DOI":"10.1115\/1.4004315"},{"key":"974_CR35","doi-asserted-by":"publisher","unstructured":"Malv\u00e8 M, P\u00e9rez del Palomar a, Chandra S et al (2011b) FSI Analysis of a healthy and a stenotic human trachea under impedance-based boundary conditions. J Biomech Eng 133:21001. \n                        https:\/\/doi.org\/10.1115\/1.4003130","DOI":"10.1115\/1.4003130"},{"key":"974_CR36","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.jmbbm.2014.08.029","volume":"40","author":"DJ McGrath","year":"2014","unstructured":"McGrath DJ, O\u2019Brien B, Bruzzi M, McHugh PE (2014) Nitinol stent design-understanding axial buckling. J Mech Behav Biomed Mater 40:252\u2013263. \n                        https:\/\/doi.org\/10.1016\/j.jmbbm.2014.08.029","journal-title":"J Mech Behav Biomed Mater"},{"key":"974_CR37","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1016\/j.jmbbm.2016.04.023","volume":"61","author":"DJ McGrath","year":"2016","unstructured":"McGrath DJ, O\u2019Brien B, Bruzzi M et al (2016) Evaluation of cover effects on bare stent mechanical response. J Mech Behav Biomed Mater 61:567\u2013580. \n                        https:\/\/doi.org\/10.1016\/j.jmbbm.2016.04.023","journal-title":"J Mech Behav Biomed Mater"},{"key":"974_CR38","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-017-0904-8","author":"DJ McGrath","year":"2017","unstructured":"McGrath DJ, Thiebes AL, Cornelissen CG et al (2017) An ovine in vivo framework for tracheobronchial stent analysis. Biomech Model Mechanobiol. \n                        https:\/\/doi.org\/10.1007\/s10237-017-0904-8","journal-title":"Biomech Model Mechanobiol"},{"key":"974_CR39","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1109\/TMI.2011.2158349","volume":"30","author":"K Murphy","year":"2011","unstructured":"Murphy K, van Ginneken B, Reinhardt JM et al (2011) Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge. IEEE Trans Med Imaging 30:1901\u20131920. \n                        https:\/\/doi.org\/10.1109\/TMI.2011.2158349","journal-title":"IEEE Trans Med Imaging"},{"key":"974_CR40","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1055\/s-2004-832711","volume":"25","author":"SC Murthy","year":"2004","unstructured":"Murthy SC, Gildea TR, Mehta AC (2004) Removal of self-expandable metallic stents: Is it possible? Semin Respir Crit Care Med 25:381\u2013385. \n                        https:\/\/doi.org\/10.1055\/s-2004-832711","journal-title":"Semin Respir Crit Care Med"},{"key":"974_CR41","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1002\/pen.23622","volume":"54","author":"I Nadzeyka","year":"2014","unstructured":"Nadzeyka I, Gabler C, Erarslan D et al (2014) Manufacturing of biocompatible nonwoven structures by using spray atomization of dissolved polymers. Polym Eng Sci 54:867\u2013873. \n                        https:\/\/doi.org\/10.1002\/pen.23622","journal-title":"Polym Eng Sci"},{"key":"974_CR42","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1378\/chest.127.2.482","volume":"127","author":"M Noppen","year":"2005","unstructured":"Noppen M, Stratakos G, D\u2019Haese J et al (2005) Removal of covered self-expandable metallic airway stents in benign disorders: indications, technique, and outcomes. Chest 127:482\u20137. \n                        https:\/\/doi.org\/10.1378\/chest.127.2.482","journal-title":"Chest"},{"key":"974_CR43","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1378\/chest.11-2005","volume":"141","author":"DE Ost","year":"2012","unstructured":"Ost DE, Shah AM, Lei X et al (2012) Respiratory infections increase the risk of granulation tissue formation following airway stenting in patients with malignant airway obstruction. Chest 141:1473\u201381. \n                        https:\/\/doi.org\/10.1378\/chest.11-2005","journal-title":"Chest"},{"key":"974_CR44","doi-asserted-by":"publisher","first-page":"2881","DOI":"10.1098\/rsta.2010.0092","volume":"368","author":"A Perez del Palomar","year":"2010","unstructured":"Perez del Palomar A, Trabelsi O, Mena A et al (2010) Patient-specific models of human trachea to predict mechanical consequences of endoprosthesis implantation. Philos Trans R Soc A Math Phys Eng Sci 368:2881\u20132896. \n                        https:\/\/doi.org\/10.1098\/rsta.2010.0092","journal-title":"Philos Trans R Soc A Math Phys Eng Sci"},{"key":"974_CR45","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1016\/S0003-4975(00)01092-4","volume":"69","author":"F Puma","year":"2000","unstructured":"Puma F, Farabi R, Urbani M et al (2000) Long-term safety and tolerance of silicone and self-expandable airway stents: an experimental study. Ann Thorac Surg 69:1030\u20134","journal-title":"Ann Thorac Surg"},{"key":"974_CR46","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/j.jmbbm.2011.01.006","volume":"4","author":"SMK Rausch","year":"2011","unstructured":"Rausch SMK, Martin C, Bornemann PB et al (2011) Material model of lung parenchyma based on living precision-cut lung slice testing. J Mech Behav Biomed Mater 4:583\u201392. \n                        https:\/\/doi.org\/10.1016\/j.jmbbm.2011.01.006","journal-title":"J Mech Behav Biomed Mater"},{"key":"974_CR47","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1016\/j.athoracsur.2010.06.093","volume":"90","author":"SS Razi","year":"2010","unstructured":"Razi SS, Lebovics RS, Schwartz G et al (2010) Timely airway stenting improves survival in patients with malignant central airway obstruction. Ann Thorac Surg 90:1088\u20131093. \n                        https:\/\/doi.org\/10.1016\/j.athoracsur.2010.06.093","journal-title":"Ann Thorac Surg"},{"key":"974_CR48","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1378\/chest.124.5.1993","volume":"124","author":"CP Saad","year":"2003","unstructured":"Saad CP, Murthy S, Krizmanich G, Mehta AC (2003) Self-expandable metallic airway stents and flexible bronchoscopy. Chest 124:1993\u20131999. \n                        https:\/\/doi.org\/10.1378\/chest.124.5.1993","journal-title":"Chest"},{"key":"974_CR49","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s00595-004-2942-y","volume":"35","author":"Y Saito","year":"2005","unstructured":"Saito Y, Imamura H (2005) Airway stenting. Surg Today 35:265\u201370. \n                        https:\/\/doi.org\/10.1007\/s00595-004-2942-y","journal-title":"Surg Today"},{"key":"974_CR50","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.tibtech.2008.02.002","volume":"26","author":"JPY Scheerlinck","year":"2008","unstructured":"Scheerlinck JPY, Snibson KJ, Bowles VM, Sutton P (2008) Biomedical applications of sheep models: from asthma to vaccines. Trends Biotechnol 26:259\u2013266. \n                        https:\/\/doi.org\/10.1016\/j.tibtech.2008.02.002","journal-title":"Trends Biotechnol"},{"key":"974_CR51","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1097\/00005537-200308000-00024","volume":"113","author":"F Schm\u00e4l","year":"2003","unstructured":"Schm\u00e4l F, Fegeler W, Terpe HJ et al (2003) Bacteria and granulation tissue associated with Montgomery T-tubes. Laryngoscope 113:1394\u20131400. \n                        https:\/\/doi.org\/10.1097\/00005537-200308000-00024","journal-title":"Laryngoscope"},{"key":"974_CR52","doi-asserted-by":"publisher","first-page":"1949","DOI":"10.1016\/j.jiec.2013.03.008","volume":"19","author":"H Sheikhy","year":"2013","unstructured":"Sheikhy H, Shahidzadeh M, Ramezanzadeh B, Noroozi F (2013) Studying the effects of chain extenders chemical structures on the adhesion and mechanical properties of a polyurethane adhesive. J Ind Eng Chem 19:1949\u20131955. \n                        https:\/\/doi.org\/10.1016\/j.jiec.2013.03.008","journal-title":"J Ind Eng Chem"},{"key":"974_CR53","unstructured":"Si H, G\u00e4rtner K (2015) Meshing piecewise linear complexes by constrained delaunay tetrahedralizations. In: Proceedings of the 14th international meshing roundtable. Springer, Berlin, pp 147\u2013163"},{"key":"974_CR54","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1007\/s00330-003-2022-5","volume":"14","author":"D Stoeckel","year":"2004","unstructured":"Stoeckel D, Pelton A, Duerig T (2004) Self-expanding nitinol stents: material and design considerations. Eur Radiol 14:292\u2013301. \n                        https:\/\/doi.org\/10.1007\/s00330-003-2022-5","journal-title":"Eur Radiol"},{"key":"974_CR55","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1152\/japplphysiol.00324.2009","volume":"107","author":"MH Tawhai","year":"2009","unstructured":"Tawhai MH, Nash MP, Lin C-L, Hoffman E (2009) Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shape. J Appl Physiol 107:912\u201320. \n                        https:\/\/doi.org\/10.1152\/japplphysiol.00324.2009","journal-title":"J Appl Physiol"},{"key":"974_CR56","doi-asserted-by":"publisher","first-page":"8833","DOI":"10.1088\/0031-9155\/60\/22\/8833","volume":"60","author":"JN Tehrani","year":"2015","unstructured":"Tehrani JN, Yang Y, Werner R et al (2015) Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters. Phys Med Biol 60:8833\u20138849. \n                        https:\/\/doi.org\/10.1088\/0031-9155\/60\/22\/8833","journal-title":"Phys Med Biol"},{"key":"974_CR57","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/s10439-016-1737-9","volume":"45","author":"AL Thiebes","year":"2017","unstructured":"Thiebes AL, Kelly N, Sweeney CA et al (2017) Pulmostent: in vitro to in vivo evaluation of a tissue engineered endobronchial stent. Ann Biomed Eng 45:873\u2013883. \n                        https:\/\/doi.org\/10.1007\/s10439-016-1737-9","journal-title":"Ann Biomed Eng"},{"key":"974_CR58","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.medengphy.2009.10.010","volume":"32","author":"O Trabelsi","year":"2010","unstructured":"Trabelsi O, del Palomar AP, L\u00f3pez-villalobos JL (2010) Experimental characterization and constitutive modeling of the mechanical behavior of the human trachea. Med Eng Phys 32:76\u201382. \n                        https:\/\/doi.org\/10.1016\/j.medengphy.2009.10.010","journal-title":"Med Eng Phys"},{"key":"974_CR59","doi-asserted-by":"publisher","first-page":"4902","DOI":"10.1016\/j.apm.2011.03.041","volume":"35","author":"O Trabelsi","year":"2011","unstructured":"Trabelsi O, P\u00e9rez del Palomar A, Mena Tobar A et al (2011) FE simulation of human trachea swallowing movement before and after the implantation of an endoprothesis. Appl Math Model 35:4902\u20134912. \n                        https:\/\/doi.org\/10.1016\/j.apm.2011.03.041","journal-title":"Appl Math Model"},{"key":"974_CR60","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1080\/10255842.2014.930448","volume":"18","author":"O Trabelsi","year":"2015","unstructured":"Trabelsi O, Malve M, Mena Tobar A, Doblare M (2015) Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion. Comput Methods Biomech Biomed Eng 18:1596\u20131605. \n                        https:\/\/doi.org\/10.1080\/10255842.2014.930448","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"974_CR61","doi-asserted-by":"crossref","unstructured":"Villard P-F, Beuve M, Shariat B et al (2005) Simulation of lung behaviour with finite elements: influence of bio-mechanical parameters. In: Third international conference on medical information visualisation\u2013biomedical visualisation. IEEE, pp 9\u201314","DOI":"10.1109\/MEDIVIS.2005.15"},{"key":"974_CR62","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1002\/fld.1763","volume":"57","author":"WA Wall","year":"2008","unstructured":"Wall WA, Rabczuk T (2008) Fluid-structure interaction in lower airways of CT-based lung geometries. Int J Numer Methods Fluids 57:653\u2013675. \n                        https:\/\/doi.org\/10.1002\/fld.1763","journal-title":"Int J Numer Methods Fluids"},{"key":"974_CR63","doi-asserted-by":"publisher","first-page":"1500","DOI":"10.1118\/1.3101820","volume":"36","author":"R Werner","year":"2009","unstructured":"Werner R, Ehrhardt J, Schmidt R, Handels H (2009) Patient-specific finite element modeling of respiratory lung motion using 4D CT image data. Med Phys 36:1500. \n                        https:\/\/doi.org\/10.1118\/1.3101820","journal-title":"Med Phys"},{"key":"974_CR64","volume-title":"Respiratory physiology: the essentials","author":"JB West","year":"2012","unstructured":"West JB (2012) Respiratory physiology: the essentials. Lippincott Williams and Wilkins, Philadelphia"},{"key":"974_CR65","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1016\/mhn.2003.107","volume":"128","author":"SA Zakaluzny","year":"2003","unstructured":"Zakaluzny SA, Lane JD, Mair EA (2003) Complications of tracheobronchial airway stents. Otolaryngol Head Neck Surg 128:478\u201388. \n                        https:\/\/doi.org\/10.1016\/mhn.2003.107","journal-title":"Otolaryngol Head Neck Surg"}],"container-title":["Biomechanics and Modeling in Mechanobiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10237-017-0974-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-017-0974-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-017-0974-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,3,9]],"date-time":"2018-03-09T09:23:42Z","timestamp":1520587422000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10237-017-0974-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,24]]},"references-count":65,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,4]]}},"alternative-id":["974"],"URL":"https:\/\/doi.org\/10.1007\/s10237-017-0974-7","relation":{},"ISSN":["1617-7959","1617-7940"],"issn-type":[{"value":"1617-7959","type":"print"},{"value":"1617-7940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,11,24]]}}}