{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T14:44:37Z","timestamp":1785768277762,"version":"3.56.0"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2023,12,8]],"date-time":"2023-12-08T00:00:00Z","timestamp":1701993600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,12,8]],"date-time":"2023-12-08T00:00:00Z","timestamp":1701993600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomech Model Mechanobiol"],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1007\/s10237-023-01784-5","type":"journal-article","created":{"date-parts":[[2023,12,8]],"date-time":"2023-12-08T15:02:06Z","timestamp":1702047726000},"page":"453-468","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Stenosis to stented: decrease in flow disturbances following stent implantation of a diseased arteriovenous fistula"],"prefix":"10.1007","volume":"23","author":[{"given":"Sanjiv","family":"Gunasekera","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charitha","family":"de Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olivia","family":"Ng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shannon","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramon","family":"Varcoe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tracie","family":"Barber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,12,8]]},"reference":[{"key":"1784_CR1","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1111\/hdi.12608","volume":"22","author":"S Anwar","year":"2017","unstructured":"Anwar S, Vachharajani TJ (2017) Stent use for hemodialysis access: what a general nephrologist needs to know. Hemodial Int 22:143\u2013149","journal-title":"Hemodial Int"},{"issue":"4","key":"1784_CR2","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1114\/1.276","volume":"28","author":"JL Berry","year":"2000","unstructured":"Berry JL, Santamarina A, Moore JE, Roychowdhury S, Routh WD (2000) Experimental and computational flow evaluation of coronary stents. Ann Biomed Eng 28(4):386\u2013398","journal-title":"Ann Biomed Eng"},{"key":"1784_CR3","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1017\/S0022112006003740","volume":"573","author":"HM Blackburn","year":"2007","unstructured":"Blackburn HM, Sherwin SJ (2007) Instability modes and transition of pulsatile stenotic flow: pulse-period dependence. J Fluid Mech 573:57\u201388","journal-title":"J Fluid Mech"},{"issue":"8","key":"1784_CR4","doi-asserted-by":"publisher","first-page":"2388","DOI":"10.1007\/s10439-015-1525-y","volume":"44","author":"M Bozzetto","year":"2016","unstructured":"Bozzetto M, Ene-Iordache B, Remuzzi A (2016) Transitional flow in the venous side of patient-specific arteriovenous fistulae for hemodialysis. Ann Biomed Eng 44(8):2388\u20132401. https:\/\/doi.org\/10.1007\/s10439-015-1525-y","journal-title":"Ann Biomed Eng"},{"key":"1784_CR5","doi-asserted-by":"crossref","unstructured":"Bozzetto M, Soliveri L, Poloni S, Brambilla P, Curt\u00f2 D, Condemi GC, Cefal\u00ec P, Spina I, Villa A, Caroli A, et al (2022) Arteriovenous fistula creation with VasQ\u2122 device: a feasibility study to reveal hemodynamic implications. J Vasc Access, 11297298221087160","DOI":"10.1177\/11297298221087160"},{"key":"1784_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2019.105203","volume":"186","author":"JE Carroll","year":"2020","unstructured":"Carroll JE, Colley ES, Thomas SD, Varcoe RL, Simmons A, Barber TJ (2020) Tracking geometric and hemodynamic alterations of an arteriovenous fistula through patient-specific modelling. Comput Methods Programs Biomed 186:105203","journal-title":"Comput Methods Programs Biomed"},{"issue":"7","key":"1784_CR7","doi-asserted-by":"publisher","DOI":"10.1115\/1.2960953","volume":"130","author":"IB Celik","year":"2008","unstructured":"Celik IB, Ghia U, Roache PJ et al (2008) Procedure for estimation and reporting of uncertainty due to discretization in $$\\{$$CFD$\\}$ applications. J Fluids Eng 130(7):078001","journal-title":"J Fluids Eng"},{"issue":"3","key":"1784_CR8","doi-asserted-by":"publisher","first-page":"243","DOI":"10.5301\/jva.5000527","volume":"17","author":"E Chemla","year":"2016","unstructured":"Chemla E, Velazquez CC, D\u2019abate F, Ramachandran V, Maytham G (2016) Arteriovenous fistula construction with the VasQ\u2122 external support device: a pilot study. J Vasc Access 17(3):243\u2013248","journal-title":"J Vasc Access"},{"issue":"3\u20134","key":"1784_CR9","doi-asserted-by":"publisher","first-page":"241","DOI":"10.3233\/BIR-1991-283-415","volume":"28","author":"YI Cho","year":"1991","unstructured":"Cho YI, Kensey KR (1991) Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: steady flows. Biorheology 28(3\u20134):241\u2013262","journal-title":"Biorheology"},{"issue":"8","key":"1784_CR10","doi-asserted-by":"publisher","first-page":"1885","DOI":"10.1109\/TBME.2017.2782781","volume":"65","author":"E Colley","year":"2018","unstructured":"Colley E, Carroll J, Thomas S, Varcoe RL, Simmons A, Barber T (2018) A methodology for non-invasive 3-d surveillance of arteriovenous fistulae using freehand ultrasound. IEEE Trans Biomed Eng 65(8):1885\u20131891","journal-title":"IEEE Trans Biomed Eng"},{"issue":"2","key":"1784_CR11","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1147\/rd.112.0215","volume":"11","author":"R Courant","year":"1967","unstructured":"Courant R, Friedrichs K, Lewy H (1967) On the partial difference equations of mathematical physics. IBM J Res Dev 11(2):215\u2013234","journal-title":"IBM J Res Dev"},{"issue":"3","key":"1784_CR12","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1007\/s13239-014-0185-7","volume":"5","author":"I Decorato","year":"2014","unstructured":"Decorato I, Salsac A-V, Legallais C, Alimohammadi M, Diaz-Zuccarini V, Kharboutly Z (2014) Influence of an arterial stenosis on the hemodynamics within an arteriovenous fistula (AVF): comparison before and after balloon-angioplasty. Cardiovasc Eng Technol 5(3):233\u2013243","journal-title":"Cardiovasc Eng Technol"},{"issue":"1","key":"1784_CR13","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1053\/j.ajkd.2016.08.025","volume":"69","author":"JC Duque","year":"2017","unstructured":"Duque JC, Tabbara M, Martinez L, Cardona J, Vazquez-Padron RI, Salman LH (2017) Dialysis arteriovenous fistula failure and angioplasty: intimal hyperplasia and other causes of access failure. Am J Kidney Dis 69(1):147\u2013151","journal-title":"Am J Kidney Dis"},{"issue":"3","key":"1784_CR14","doi-asserted-by":"publisher","DOI":"10.1115\/1.4038289","volume":"140","author":"D Fulker","year":"2018","unstructured":"Fulker D, Ene-Iordache B, Barber T (2018) High-resolution computational fluid dynamic simulation of haemodialysis cannulation in a patient-specific arteriovenous fistula. J Biomech Eng 140(3):031011","journal-title":"J Biomech Eng"},{"key":"1784_CR15","doi-asserted-by":"crossref","unstructured":"Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2020a) Tomographic PIV analysis of physiological flow conditions in a patient-specific arteriovenous fistula. Exp Fluids 61(12):1\u201314","DOI":"10.1007\/s00348-020-03085-4"},{"key":"1784_CR16","doi-asserted-by":"crossref","unstructured":"Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2020b) A numerical investigation of a stented arteriovenous fistula. In: Chanson H, Brown R (eds) Proceedings of the 22nd Australasian fluid mechanics conference. The University of Queensland, St Lucia","DOI":"10.14264\/160df47"},{"key":"1784_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijheatfluidflow.2021.108874","volume":"92","author":"S Gunasekera","year":"2021","unstructured":"Gunasekera S, Ng O, Thomas S, Varcoe R, de Silva C, Barber T (2021) Impact of juxta-anastomotic stent implantation on the haemodynamics within a single representative patient AVF. Int J Heat Fluid Flow 92:108874","journal-title":"Int J Heat Fluid Flow"},{"key":"1784_CR18","doi-asserted-by":"publisher","first-page":"123101","DOI":"10.1103\/PhysRevFluids.7.123101","volume":"7","author":"S Gunasekera","year":"2022","unstructured":"Gunasekera S, Barber T, Ng O, Thomas S, Varcoe R, de Silva C (2022) Mitigation of the turbulence within an arteriovenous fistula with a stent implantation. Phys Rev Fluids 7:123101. https:\/\/doi.org\/10.1103\/PhysRevFluids.7.123101","journal-title":"Phys Rev Fluids"},{"issue":"1","key":"1784_CR19","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1115\/1.2795948","volume":"118","author":"X He","year":"1996","unstructured":"He X, Ku DN (1996) Pulsatile flow in the human left coronary artery bifurcation: average conditions. J Biomech Eng 118(1):74\u201382","journal-title":"J Biomech Eng"},{"key":"1784_CR20","unstructured":"Hunt JC, Wray AA, Moin P (1988) Eddies, streams, and convergence zones in turbulent flows. In: Studying turbulence using numerical simulation databases, 2. Proceedings of the 1988 summer program"},{"issue":"8","key":"1784_CR21","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1177\/0954411916644474","volume":"230","author":"E Jabir","year":"2016","unstructured":"Jabir E, Lal SA (2016) Numerical analysis of blood flow through an elliptic stenosis using large eddy simulation. Proc Inst Mech Eng Part H 230(8):709\u2013726","journal-title":"Proc Inst Mech Eng Part H"},{"issue":"04","key":"1784_CR22","doi-asserted-by":"publisher","first-page":"1950032","DOI":"10.1142\/S1758825119500327","volume":"11","author":"N Johari","year":"2019","unstructured":"Johari N, Wood N, Cheng Z, Torii R, Oishi M, Oshima M, Xu X (2019) Disturbed flow in a stenosed carotid artery bifurcation: comparison of rans-based transitional model and les with experimental measurements. Int J Appl Mech 11(04):1950032","journal-title":"Int J Appl Mech"},{"issue":"12","key":"1784_CR23","doi-asserted-by":"publisher","first-page":"2773","DOI":"10.1109\/TVCG.2013.189","volume":"19","author":"B K\u00f6hler","year":"2013","unstructured":"K\u00f6hler B, Gasteiger R, Preim U, Theisel H, Gutberlet M, Preim B (2013) Semi-automatic vortex extraction in 4D PC-MRI cardiac blood flow data using line predicates. IEEE Trans Vis Comput Graph 19(12):2773\u20132782","journal-title":"IEEE Trans Vis Comput Graph"},{"issue":"8","key":"1784_CR24","doi-asserted-by":"publisher","first-page":"1139","DOI":"10.1016\/j.medengphy.2011.12.002","volume":"34","author":"J Lantz","year":"2012","unstructured":"Lantz J, G\u00e5rdhagen R, Karlsson M (2012) Quantifying turbulent wall shear stress in a subject specific human aorta using large eddy simulation. Med Eng Phys 34(8):1139\u20131148","journal-title":"Med Eng Phys"},{"issue":"9981","key":"1784_CR25","doi-asserted-by":"publisher","first-page":"1975","DOI":"10.1016\/S0140-6736(14)61601-9","volume":"385","author":"T Liyanage","year":"2015","unstructured":"Liyanage T, Ninomiya T, Jha V, Neal B, Patrice HM, Okpechi I, Zhao M-H, Lv J, Garg AX, Knight J et al (2015) Worldwide access to treatment for end-stage kidney disease: a systematic review. The Lancet 385(9981):1975\u20131982","journal-title":"The Lancet"},{"issue":"4","key":"1784_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1053\/j.ajkd.2019.12.001","volume":"75","author":"CE Lok","year":"2020","unstructured":"Lok CE, Huber TS, Lee T, Shenoy S, Yevzlin AS, Abreo K, Allon M, Asif A, Astor BC, Glickman MH et al (2020) Kdoqi clinical practice guideline for vascular access: 2019 update. Am J Kidney Dis 75(4):1\u2013164","journal-title":"Am J Kidney Dis"},{"issue":"1","key":"1784_CR27","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.jvs.2010.12.050","volume":"54","author":"M Mallik","year":"2011","unstructured":"Mallik M, Sivaprakasam R, Pettigrew GJ, Callaghan CJ (2011) Operative salvage of radiocephalic arteriovenous fistulas by formation of a proximal neoanastomosis. J Vasc Surg 54(1):168\u2013173","journal-title":"J Vasc Surg"},{"key":"1784_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s13239-021-00536-9","volume":"12","author":"EL Manchester","year":"2021","unstructured":"Manchester EL, Pirola S, Salmasi MY, O\u2019Regan DP, Athanasiou T, Xu XY (2021) Analysis of turbulence effects in a patient-specific aorta with aortic valve stenosis. Cardiovasc Eng Technol 12:1\u201316","journal-title":"Cardiovasc Eng Technol"},{"issue":"3","key":"1784_CR29","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1007\/s10237-013-0527-7","volume":"13","author":"PM McGah","year":"2014","unstructured":"McGah PM, Leotta DF, Beach KW, Aliseda A (2014) Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula. Biomech Model Mechanobiol 13(3):679\u2013695","journal-title":"Biomech Model Mechanobiol"},{"key":"1784_CR30","doi-asserted-by":"crossref","unstructured":"Ng O, Gunasekera S, Thomas S, Varcoe R, Barber T (2020) A clinical predictive indicator for arteriovenous fistula (AVF) failure. In: Chanson H, Brown R (eds) Proceedings of the 22nd Australasian fluid mechanics conference. The University of Queensland, St Lucia","DOI":"10.14264\/d3dc63e"},{"key":"1784_CR31","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.779043","volume":"9","author":"H Northrup","year":"2021","unstructured":"Northrup H, Somarathna M, Corless S, Falzon I, Totenhagen J, Lee T, Shiu Y-T (2021) Analysis of geometric and hemodynamic profiles in rat arteriovenous fistula following PDE5A inhibition. Front Bioeng Biotechnol 9:779043","journal-title":"Front Bioeng Biotechnol"},{"issue":"7","key":"1784_CR32","doi-asserted-by":"publisher","DOI":"10.1115\/1.4027610","volume":"136","author":"A Pal","year":"2014","unstructured":"Pal A, Anupindi K, Delorme Y, Ghaisas N, Shetty DA, Frankel SH (2014) Large eddy simulation of transitional flow in an idealized stenotic blood vessel: evaluation of subgrid scale models. J Biomech Eng 136(7):071009","journal-title":"J Biomech Eng"},{"issue":"11","key":"1784_CR33","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1088\/0957-0233\/12\/11\/705","volume":"12","author":"SB Pope","year":"2001","unstructured":"Pope SB (2001) Turbulent flows. Meas Sci Technol 12(11):2020\u20132021. https:\/\/doi.org\/10.1088\/0957-0233\/12\/11\/705","journal-title":"Meas Sci Technol"},{"issue":"4","key":"1784_CR34","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1681\/ASN.2005050615","volume":"17","author":"P Roy-Chaudhury","year":"2006","unstructured":"Roy-Chaudhury P, Sukhatme VP, Cheung AK (2006) Hemodialysis vascular access dysfunction: a cellular and molecular viewpoint. J Am Soc Nephrol 17(4):1112\u20131127","journal-title":"J Am Soc Nephrol"},{"key":"1784_CR35","doi-asserted-by":"publisher","first-page":"281","DOI":"10.2147\/IJNRD.S46643","volume":"7","author":"D Santoro","year":"2014","unstructured":"Santoro D, Benedetto F, Mondello P, Pipit\u00f2 N, Barill\u00e0 D, Spinelli F, Ricciardi CA, Cernaro V, Buemi M (2014) Vascular access for hemodialysis: current perspectives. Int J Nephrol Renov Dis 7:281","journal-title":"Int J Nephrol Renov Dis"},{"issue":"3","key":"1784_CR36","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1159\/000343669","volume":"22","author":"R Stolic","year":"2013","unstructured":"Stolic R (2013) Most important chronic complications of arteriovenous fistulas for hemodialysis. Med Princ Pract 22(3):220\u2013228","journal-title":"Med Princ Pract"},{"issue":"3","key":"1784_CR37","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1177\/1526602819842851","volume":"26","author":"SD Thomas","year":"2019","unstructured":"Thomas SD, Peden S, Crowe P, Varcoe RL (2019) Interwoven nitinol stents to treat radiocephalic anastomotic arteriovenous fistula stenosis. J Endovasc Ther 26(3):394\u2013401","journal-title":"J Endovasc Ther"},{"issue":"2","key":"1784_CR38","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1177\/15266028221075230","volume":"30","author":"SD Thomas","year":"2023","unstructured":"Thomas SD, Peden S, Katib N, Crowe P, Barber T, Varcoe RL (2023) Long-term results of interwoven nitinol stents to treat the radiocephalic anastomotic arteriovenous fistula stenosis. J Endovasc Ther 30(2):176\u2013184","journal-title":"J Endovasc Ther"},{"issue":"12","key":"1784_CR39","doi-asserted-by":"publisher","first-page":"3210","DOI":"10.1016\/j.jbiomech.2014.04.018","volume":"47","author":"K Valen-Sendstad","year":"2014","unstructured":"Valen-Sendstad K, Piccinelli M, Steinman DA (2014) High-resolution computational fluid dynamics detects flow instabilities in the carotid siphon: implications for aneurysm initiation and rupture? J Biomech 47(12):3210\u20133216","journal-title":"J Biomech"},{"key":"1784_CR40","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1017\/S0022112007005836","volume":"582","author":"SS Varghese","year":"2007","unstructured":"Varghese SS, Frankel SH, Fischer PF (2007) Direct numerical simulation of stenotic flows. Part 2. Pulsatile flow. J Fluid Mech 582:281\u2013318","journal-title":"J Fluid Mech"},{"issue":"6","key":"1784_CR41","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0128178","volume":"10","author":"PR Vijayaratnam","year":"2015","unstructured":"Vijayaratnam PR, O\u2019Brien CC, Reizes JA, Barber TJ, Edelman ER (2015) The impact of blood rheology on drug transport in stented arteries: steady simulations. PLoS ONE 10(6):e0128178","journal-title":"PLoS ONE"},{"issue":"9","key":"1784_CR42","doi-asserted-by":"publisher","first-page":"2130","DOI":"10.1161\/ATVBAHA.113.301826","volume":"33","author":"C Wang","year":"2013","unstructured":"Wang C, Baker BM, Chen CS, Schwartz MA (2013) Endothelial cell sensing of flow direction. Arterioscler Thromb Vasc Biol 33(9):2130\u20132136","journal-title":"Arterioscler Thromb Vasc Biol"},{"issue":"2","key":"1784_CR43","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.jtcvs.2020.02.034","volume":"162","author":"H Xu","year":"2021","unstructured":"Xu H, Xiong J, Han X, Mei Y, Shi Y, Wang D, Zhang M, Chen D (2021) Computed tomography-based hemodynamic index for aortic dissection. J Thorac Cardiovasc Surg 162(2):165\u2013176","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Biomechanics and Modeling in Mechanobiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-023-01784-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10237-023-01784-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-023-01784-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,25]],"date-time":"2024-03-25T13:27:10Z","timestamp":1711373230000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10237-023-01784-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,8]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["1784"],"URL":"https:\/\/doi.org\/10.1007\/s10237-023-01784-5","relation":{},"ISSN":["1617-7959","1617-7940"],"issn-type":[{"value":"1617-7959","type":"print"},{"value":"1617-7940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,8]]},"assertion":[{"value":"11 March 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Shannon Thomas reports a relationship with Abbott Vascular, Medtronic, W. L. Gore, Bio-Excel, and Shockwave that includes: consulting or advisory, funding grants, paid expert testimony, speaking and lecture fees, and travel reimbursement. Shannon Thomas is a shareholder and chief medical officer in Vexev. Ramon Varcoe reports a relationship with Abbott Vascular, Medtronic, InterVene Inc., Surmodics, Philips, BD Bard Inc., Boston Scientific, W. L. Gore, and Nectero that includes: consulting or advisory fees. Ramon Varcoe is a shareholder in EBR systems and Provision Inc. Tracie Barber reports a relationship with Abbott Vascular that includes: consulting or advisory.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The patient\u2019s data were obtained after informed consent was given under the Low\/Negligible Risk (LNR) Application with the Human Research Ethics Committee number 15\/063 (LNR\/16\/POWH\/7). The ethics for the related longitudinal study was updated under the Human Research Ethics Application ID 2018\/ETH00577.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}