{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T11:26:35Z","timestamp":1793964395454,"version":"4.8.0"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T00:00:00Z","timestamp":1789516800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T00:00:00Z","timestamp":1789516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"National Science Foundation","award":["No. 2322067"],"award-info":[{"award-number":["No. 2322067"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomech Model Mechanobiol"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Parkinson\u2019s disease (PD) is a progressive neurological disorder often treated with Deep Brain Stimulation (DBS), a surgical procedure that involves implanting electrodes to improve motor function. Accurate electrode placement is critical for treatment efficacy but can be influenced by tissue deformation, insertion forces, and the mechanical properties of brain tissue. In this study, we investigated the role of layer interface angle as a controlled biomechanical factor affecting insertion forces and electrode deviation. A two-layer agar gel phantom was constructed to produce a prescribed stiffness transition between a lower-stiffness and a higher-stiffness gel layer, and its small-amplitude dynamic shear-stiffness contrast was characterized using magnetic resonance elastography (MRE) at 100\u00a0Hz. A stage-wise analytical model was formulated to describe the Z-direction axial force\u2013depth response\n                    <jats:inline-formula>\n                      <jats:alternatives>\n                        <jats:tex-math>$${F}_{z}\\left(z\\right)$$<\/jats:tex-math>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                          <mml:mrow>\n                            <mml:msub>\n                              <mml:mi>F<\/mml:mi>\n                              <mml:mi>z<\/mml:mi>\n                            <\/mml:msub>\n                            <mml:mfenced>\n                              <mml:mi>z<\/mml:mi>\n                            <\/mml:mfenced>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    during indentation, fracture, relaxation, and frictional sliding, and a hybrid physics-guided residual neural network (PGNN) was explored as a secondary residual-correction approach for the remaining axial-force model discrepancies. The lateral interface-force change\n                    <jats:inline-formula>\n                      <jats:alternatives>\n                        <jats:tex-math>$${F}_{iy}$$<\/jats:tex-math>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                          <mml:msub>\n                            <mml:mi>F<\/mml:mi>\n                            <mml:mrow>\n                              <mml:mi>iy<\/mml:mi>\n                            <\/mml:mrow>\n                          <\/mml:msub>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    was obtained directly from the measured Y-direction force signal, while electrode deviation was quantified in a separate series of phantom experiments. Insertion experiments at interface angles of 0\u00b0, 15\u00b0, 30\u00b0, 45\u00b0, 60\u00b0, and 75\u00b0 demonstrated that the lateral (Y-direction) interface force increased from 0.886\u00a0mN at 0\u00b0 to 7.72\u00a0mN at 75\u00b0. For the deviation analysis, the mean value of the 0\u00b0 group was defined as the zero reference; relative to this baseline, the largest group mean deviation was 0.0529\u00a0mm at 75\u00b0. These findings highlight the role of interface geometry in probe trajectory stability and provide a mechanistic baseline for future studies of probe insertion in two-layer media.\n                  <\/jats:p>","DOI":"10.1007\/s10237-026-02122-1","type":"journal-article","created":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T21:21:31Z","timestamp":1789593691000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Interface geometry governs probe insertion mechanics and electrode deviation in layered brain-mimicking phantoms for deep brain stimulation"],"prefix":"10.1007","volume":"25","author":[{"given":"Siyu","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengyuan","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ethan","family":"Anders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rungun","family":"Nathan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olivia M.","family":"Bailey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qifu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Curtis L.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6216-5674","authenticated-orcid":false,"given":"Qianhong","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,16]]},"reference":[{"key":"2122_CR1","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.medengphy.2006.07.003","volume":"29","author":"N Abolhassani","year":"2007","unstructured":"Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29:413\u2013431. https:\/\/doi.org\/10.1016\/j.medengphy.2006.07.003","journal-title":"Med Eng Phys"},{"key":"2122_CR2","doi-asserted-by":"publisher","DOI":"10.3390\/gels9120944","author":"E Albor-Ram\u00edrez","year":"2023","unstructured":"Albor-Ram\u00edrez E, Reyes-Alberto M, Vidal-Flores LM et al (2023) Agarose gel characterization for the fabrication of brain tissue phantoms for infrared multispectral vision systems. Gels. https:\/\/doi.org\/10.3390\/gels9120944","journal-title":"Gels"},{"key":"2122_CR3","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.bspc.2007.06.003","volume":"2","author":"L Barb\u00e9","year":"2007","unstructured":"Barb\u00e9 L, Bayle B, de Mathelin M, Gangi A (2007) Needle insertions modeling: identifiability and limitations. Biomed Signal Process Control 2:191\u2013198. https:\/\/doi.org\/10.1016\/j.bspc.2007.06.003","journal-title":"Biomed Signal Process Control"},{"key":"2122_CR4","doi-asserted-by":"publisher","DOI":"10.1038\/s41531-022-00321-y","author":"M Beckers","year":"2022","unstructured":"Beckers M, Bloem BR, Verbeek MM (2022) Mechanisms of peripheral levodopa resistance in Parkinson\u2019s disease. NPJ Parkinsons Dis. https:\/\/doi.org\/10.1038\/s41531-022-00321-y","journal-title":"NPJ Parkinsons Dis"},{"key":"2122_CR5","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.jmbbm.2015.02.024","volume":"46","author":"S Budday","year":"2015","unstructured":"Budday S, Nay R, de Rooij R et al (2015) Mechanical properties of gray and white matter brain tissue by indentation. J Mech Behav Biomed Mater 46:318\u2013330. https:\/\/doi.org\/10.1016\/j.jmbbm.2015.02.024","journal-title":"J Mech Behav Biomed Mater"},{"key":"2122_CR6","doi-asserted-by":"publisher","DOI":"10.3171\/2015.4.FOCUS15179","author":"K Burchiel","year":"2015","unstructured":"Burchiel K, Liker MA, Lozano AM (2015) Deep brain stimulation: current assessment, new applications, and future innovations. Neurosurg Focus. https:\/\/doi.org\/10.3171\/2015.4.FOCUS15179","journal-title":"Neurosurg Focus"},{"key":"2122_CR7","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.657875","volume":"9","author":"F Chapelle","year":"2021","unstructured":"Chapelle F, Manciet L, Pereira B et al (2021) Early deformation of deep brain stimulation electrodes following surgical implantation: intracranial, brain, and electrode mechanics. Front Bioeng Biotechnol 9:657875. https:\/\/doi.org\/10.3389\/fbioe.2021.657875","journal-title":"Front Bioeng Biotechnol"},{"key":"2122_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.nicl.2019.101750","author":"CA Chaze","year":"2019","unstructured":"Chaze CA, McIlvain G, Smith DR et al (2019) Altered brain tissue viscoelasticity in pediatric cerebral palsy measured by magnetic resonance elastography. Neuroimage Clin. https:\/\/doi.org\/10.1016\/j.nicl.2019.101750","journal-title":"Neuroimage Clin"},{"key":"2122_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2026.107582","volume":"183","author":"S Chen","year":"2026","unstructured":"Chen S, Nathan R, Sidnawi B et al (2026) Biomechanical study of probe\u2013tissue interactions during deep brain stimulation: force measurement and channel deformation in agar gel phantoms. J Mech Behav Biomed Mater 183:107582. https:\/\/doi.org\/10.1016\/j.jmbbm.2026.107582","journal-title":"J Mech Behav Biomed Mater"},{"key":"2122_CR10","unstructured":"Siyu Chen, Rungun Nathan, Bchara Sidnawi, et al (2024) Experimental Investigation of Biomechanical Properties Influencing Electrode Deviation in Deep Brain Stimulation. Salt Lake City"},{"key":"2122_CR11","doi-asserted-by":"publisher","first-page":"2576","DOI":"10.1364\/BOE.487179","volume":"14","author":"KC Chong","year":"2023","unstructured":"Chong KC, Pramanik M (2023) Physics-guided neural network for tissue optical properties estimation. Biomed Opt Express 14:2576\u20132590. https:\/\/doi.org\/10.1364\/BOE.487179","journal-title":"Biomed Opt Express"},{"key":"2122_CR12","doi-asserted-by":"publisher","DOI":"10.1007\/s10915-022-01939-z","author":"S Cuomo","year":"2022","unstructured":"Cuomo S, Di Cola VS, Giampaolo F et al (2022) Scientific machine learning through physics\u2013informed neural networks: where we are and what\u2019s next. J Sci Comput. https:\/\/doi.org\/10.1007\/s10915-022-01939-z","journal-title":"J Sci Comput"},{"key":"2122_CR13","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.colsurfb.2015.06.044","volume":"134","author":"YM Efremov","year":"2015","unstructured":"Efremov YM, Bagrov DV, Kirpichnikov MP, Shaitan KV (2015) Application of the Johnson-Kendall-Roberts model in AFM-based mechanical measurements on cells and gel. Colloids Surf B Biointerfaces 134:131\u2013139. https:\/\/doi.org\/10.1016\/j.colsurfb.2015.06.044","journal-title":"Colloids Surf B Biointerfaces"},{"key":"2122_CR14","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.forsciint.2016.04.005","volume":"263","author":"L Falland-Cheung","year":"2016","unstructured":"Falland-Cheung L, Piccione N, Zhao T et al (2016) Investigation of dental alginate and agar impression materials as a brain simulant for ballistic testing. Forensic Sci Int 263:169\u2013175. https:\/\/doi.org\/10.1016\/j.forsciint.2016.04.005","journal-title":"Forensic Sci Int"},{"key":"2122_CR15","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1227\/ons.0000000000000977","volume":"26","author":"I Fayed","year":"2024","unstructured":"Fayed I, Smit RD, Vinjamuri S et al (2024) Robot-assisted minimally invasive asleep single-stage deep brain stimulation surgery: operative technique and systematic review. Oper Neurosurg 26:363\u2013371","journal-title":"Oper Neurosurg"},{"key":"2122_CR16","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1136\/jnnp.2010.205542","volume":"82","author":"T Foltynie","year":"2011","unstructured":"Foltynie T, Zrinzo L, Martinez-Torres I et al (2011) MRI-guided STN DBS in Parkinson\u2019s disease without microelectrode recording: efficacy and safety. J Neurol Neurosurg Psychiatry 82:358\u2013363. https:\/\/doi.org\/10.1136\/jnnp.2010.205542","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"2122_CR17","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1152\/ajplegacy.1967.213.6.1532","volume":"213","author":"YC Fung","year":"1967","unstructured":"Fung YC (1967) Elasticity of soft tissues in simple elongation. Am J Physiol 213:1532\u20131544. https:\/\/doi.org\/10.1152\/ajplegacy.1967.213.6.1532","journal-title":"Am J Physiol"},{"key":"2122_CR18","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1089\/089771503770802853","volume":"20","author":"A Gefen","year":"2003","unstructured":"Gefen A, Gefen N, Zhu Q et al (2003) Age-dependent changes in material properties of the brain and braincase of the rat. J Neurotrauma 20:1163\u20131177. https:\/\/doi.org\/10.1089\/089771503770802853","journal-title":"J Neurotrauma"},{"key":"2122_CR19","doi-asserted-by":"publisher","first-page":"5282","DOI":"10.1002\/hbm.25192","volume":"41","author":"LV Hiscox","year":"2020","unstructured":"Hiscox LV, McGarry MDJ, Schwarb H et al (2020) Standard-space atlas of the viscoelastic properties of the human brain. Hum Brain Mapp 41:5282\u20135300. https:\/\/doi.org\/10.1002\/hbm.25192","journal-title":"Hum Brain Mapp"},{"key":"2122_CR20","doi-asserted-by":"publisher","first-page":"3344","DOI":"10.1016\/j.jbiomech.2014.08.007","volume":"47","author":"S Jiang","year":"2014","unstructured":"Jiang S, Li P, Yu Y et al (2014) Experimental study of needle-tissue interaction forces: effect of needle geometries, insertion methods and tissue characteristics. J Biomech 47:3344\u20133353. https:\/\/doi.org\/10.1016\/j.jbiomech.2014.08.007","journal-title":"J Biomech"},{"key":"2122_CR21","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9781139171731","volume-title":"Contact mechanics","author":"KL Johnson","year":"1985","unstructured":"Johnson KL (1985) Contact mechanics, First edition. Cambridge University Press, Cambridge","edition":"First edition"},{"key":"2122_CR22","doi-asserted-by":"publisher","first-page":"722","DOI":"10.3171\/2021.12.JNS211729","volume":"137","author":"KJ Kluin","year":"2022","unstructured":"Kluin KJ, Mossner JM, Costello JT et al (2022) Motor speech effects in subthalamic deep brain stimulation for Parkinson\u2019s disease. J Neurosurg 137:722\u2013728. https:\/\/doi.org\/10.3171\/2021.12.JNS211729","journal-title":"J Neurosurg"},{"key":"2122_CR23","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1159\/000479527","volume":"95","author":"AL Ko","year":"2017","unstructured":"Ko AL, Ibrahim A, Magown P et al (2017) Factors affecting stereotactic accuracy in image-guided deep brain stimulator electrode placement. Stereotact Funct Neurosurg 95:315\u2013324. https:\/\/doi.org\/10.1159\/000479527","journal-title":"Stereotact Funct Neurosurg"},{"key":"2122_CR24","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1159\/000449206","volume":"94","author":"Z Li","year":"2016","unstructured":"Li Z, Zhang J-G, Ye Y, Li X (2016) Review on factors affecting targeting accuracy of deep brain stimulation electrode implantation between 2001 and 2015. Stereotact Funct Neurosurg 94:351\u2013362. https:\/\/doi.org\/10.1159\/000449206","journal-title":"Stereotact Funct Neurosurg"},{"key":"2122_CR25","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/S1361-8415(00)00039-6","volume":"5","author":"A Manduca","year":"2001","unstructured":"Manduca A, Oliphant TE, Dresner MA et al (2001) Magnetic resonance elastography: non-invasive mapping of tissue elasticity. Med Image Anal 5:237\u2013254. https:\/\/doi.org\/10.1016\/S1361-8415(00)00039-6","journal-title":"Med Image Anal"},{"key":"2122_CR26","doi-asserted-by":"publisher","DOI":"10.1038\/s41531-018-0058-0","author":"C Marras","year":"2018","unstructured":"Marras C, Beck JC, Bower JH et al (2018) Prevalence of parkinson\u2019s disease across North America. NPJ Parkinsons Dis. https:\/\/doi.org\/10.1038\/s41531-018-0058-0","journal-title":"NPJ Parkinsons Dis"},{"key":"2122_CR27","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1177\/2192568220902401","volume":"11","author":"PA Massey","year":"2021","unstructured":"Massey PA, Hoge S, Nelson BG et al (2021) Nitinol memory rods versus titanium rods: a biomechanical comparison of posterior spinal instrumentation in a synthetic corpectomy model. Global Spine J 11:277\u2013282. https:\/\/doi.org\/10.1177\/2192568220902401","journal-title":"Global Spine J"},{"key":"2122_CR28","doi-asserted-by":"publisher","first-page":"6388","DOI":"10.1118\/1.4754649","volume":"39","author":"MDJ McGarry","year":"2012","unstructured":"McGarry MDJ, Van Houten EEW, Johnson CL et al (2012) Multiresolution MR elastography using nonlinear inversion. Med Phys 39:6388\u20136396. https:\/\/doi.org\/10.1118\/1.4754649","journal-title":"Med Phys"},{"key":"2122_CR29","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.jmbbm.2019.05.001","volume":"97","author":"G McIlvain","year":"2019","unstructured":"McIlvain G, Ganji E, Cooper C et al (2019) Reliable preparation of agarose phantoms for use in quantitative magnetic resonance elastography. J Mech Behav Biomed Mater 97:65\u201373. https:\/\/doi.org\/10.1016\/j.jmbbm.2019.05.001","journal-title":"J Mech Behav Biomed Mater"},{"key":"2122_CR30","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1001\/2013.jamaneurol.45","volume":"70","author":"S Miocinovic","year":"2013","unstructured":"Miocinovic S, Somayajula S, Chitnis S, Vitek JL (2013) History, applications, and mechanisms of deep brain stimulation. JAMA Neurol 70:163\u2013171","journal-title":"JAMA Neurol"},{"key":"2122_CR31","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.neuroimage.2017.10.008","volume":"187","author":"MC Murphy","year":"2019","unstructured":"Murphy MC, Huston J, Ehman RL (2019) MR elastography of the brain and its application in neurological diseases. Neuroimage 187:176\u2013183. https:\/\/doi.org\/10.1016\/j.neuroimage.2017.10.008","journal-title":"Neuroimage"},{"key":"2122_CR32","doi-asserted-by":"publisher","first-page":"1854","DOI":"10.1126\/science.7569924","volume":"269","author":"R Muthupillai","year":"1995","unstructured":"Muthupillai R, Lomas DJ, Rossman PJ et al (1995) Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science 269:1854\u20131857. https:\/\/doi.org\/10.1126\/science.7569924","journal-title":"Science"},{"key":"2122_CR33","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.mric.2021.06.011","volume":"29","author":"M Nanjappa","year":"2021","unstructured":"Nanjappa M, Kolipaka A (2021) Magnetic resonance elastography of the brain. Magn Reson Imaging Clin N Am 29:617\u2013630. https:\/\/doi.org\/10.1016\/j.mric.2021.06.011","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"2122_CR34","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura AM, Simone C, O\u2019Leary MD (2004) Force modeling for needle insertion into soft tissue. IEEE Trans Biomed Eng 51:1707\u20131716. https:\/\/doi.org\/10.1109\/TBME.2004.831542","journal-title":"IEEE Trans Biomed Eng"},{"key":"2122_CR35","doi-asserted-by":"publisher","DOI":"10.1093\/neuros\/nyaa428","author":"LR Philipp","year":"2021","unstructured":"Philipp LR, Matias CM, Thalheimer S et al (2021) Robot-assisted stereotaxy reduces target error: a meta-analysis and meta-regression of 6056 trajectories. Neurosurgery. https:\/\/doi.org\/10.1093\/neuros\/nyaa428","journal-title":"Neurosurgery"},{"key":"2122_CR36","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.3171\/2022.8.JNS22968","volume":"138","author":"A Rajabian","year":"2023","unstructured":"Rajabian A, Vinke S, Candelario-Mckeown J et al (2023) Accuracy, precision, and safety of stereotactic, frame-based, intraoperative MRI-guided and MRI-verified deep brain stimulation in 650 consecutive procedures. J Neurosurg 138:1702\u20131711. https:\/\/doi.org\/10.3171\/2022.8.JNS22968","journal-title":"J Neurosurg"},{"key":"2122_CR37","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2017.00734","author":"A Ramirez-Zamora","year":"2018","unstructured":"Ramirez-Zamora A, Giordano JJ, Gunduz A et al (2018) Evolving applications, technological challenges and future opportunities in neuromodulation: proceedings of the fifth annual deep brain stimulation think tank. Front Neurosci. https:\/\/doi.org\/10.3389\/fnins.2017.00734","journal-title":"Front Neurosci"},{"key":"2122_CR38","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1016\/S1474-4422(18)30295-3","volume":"17","author":"E Ray Dorsey","year":"2018","unstructured":"Ray Dorsey E, Elbaz A, Nichols E et al (2018) Global, regional, and national burden of Parkinson\u2019s disease, 1990\u20132016: a systematic analysis for the global burden of disease study 2016. Lancet Neurol 17:939\u2013953. https:\/\/doi.org\/10.1016\/S1474-4422(18)30295-3","journal-title":"Lancet Neurol"},{"key":"2122_CR39","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aacb08","author":"LM Solamen","year":"2018","unstructured":"Solamen LM, McGarry MD, Tan L et al (2018) Phantom evaluations of nonlinear inversion MR elastography. Phys Med Biol. https:\/\/doi.org\/10.1088\/1361-6560\/aacb08","journal-title":"Phys Med Biol"},{"key":"2122_CR40","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/abb581","author":"M Vissani","year":"2020","unstructured":"Vissani M, Isaias IU, Mazzoni A (2020) Deep brain stimulation: a review of the open neural engineering challenges. J Neural Eng. https:\/\/doi.org\/10.1088\/1741-2552\/abb581","journal-title":"J Neural Eng"},{"key":"2122_CR41","doi-asserted-by":"publisher","DOI":"10.1227\/ons.0000000000001523","author":"C Wu","year":"2025","unstructured":"Wu C, Alizadeh M, Kramer MK et al (2025) Deep brain stimulation electrode deviations are associated with brain stiffness interfaces measured by magnetic resonance elastography. Oper Neurosurg. https:\/\/doi.org\/10.1227\/ons.0000000000001523","journal-title":"Oper Neurosurg"},{"key":"2122_CR42","unstructured":"Zhou B, Ziechmann R, Chen S, et al Re-evaluating Sources of Electrode Deviation in Deep Brain Stimulation: Surgical Technique vs. Patient-Specific Brain Mechanics. J Neurosurg"},{"key":"2122_CR43","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1227\/ONS.0000000000001754","volume":"31","author":"R Ziechmann","year":"2026","unstructured":"Ziechmann R, Hines K, Matias C et al (2026) Surgical technique for repositioning deep brain stimulation electrodes. Oper Neurosurg 31:28\u201335. https:\/\/doi.org\/10.1227\/ONS.0000000000001754","journal-title":"Oper Neurosurg"}],"container-title":["Biomechanics and Modeling in Mechanobiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-026-02122-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10237-026-02122-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-026-02122-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T10:53:28Z","timestamp":1793962408000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10237-026-02122-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,16]]},"references-count":43,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["2122"],"URL":"https:\/\/doi.org\/10.1007\/s10237-026-02122-1","relation":{},"ISSN":["1617-7959","1617-7940"],"issn-type":[{"value":"1617-7959","type":"print"},{"value":"1617-7940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,16]]},"assertion":[{"value":"14 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"106"}}