{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T08:08:53Z","timestamp":1790150933060,"version":"4.0.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"International Spine Research Foundation"},{"name":"CBP Nonprofit Inc"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomech Model Mechanobiol"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1007\/s10237-026-02126-x","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T07:45:37Z","timestamp":1790149537000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Validation of lumped-parameter models of the human lumbar spine using in vivo driving-point compliance data during spinal manipulation"],"prefix":"10.1007","volume":"25","author":[{"given":"Christopher J.","family":"Colloca","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Gunzburg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"issue":"6","key":"2126_CR1","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1016\/S2665-9913(23)00098-X","volume":"5","author":"ML Ferreira","year":"2023","unstructured":"Ferreira ML, Luca K, Haile LM et al (2023) Global, regional, and national burden of low back pain, 1990\u20132020, its attributable risk factors, and projections to 2050: a systematic analysis of the Global Burden of Disease Study 2021. Lancet Rheumatol 5(6):316\u2013329. https:\/\/doi.org\/10.1016\/S2665-9913(23)00098-X","journal-title":"Lancet Rheumatol"},{"issue":"9","key":"2126_CR2","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1001\/jama.2020.0734","volume":"323","author":"JL Dieleman","year":"2020","unstructured":"Dieleman JL, Cao J, Chapin A et al (2020) US health care spending by payer and health condition, 1996\u20132016. JAMA 323(9):863\u2013884. https:\/\/doi.org\/10.1001\/jama.2020.0734","journal-title":"JAMA"},{"issue":"7","key":"2126_CR3","doi-asserted-by":"publisher","first-page":"514","DOI":"10.7326\/M16-2367","volume":"166","author":"A Qaseem","year":"2017","unstructured":"Qaseem A, Wilt TJ, McLean RM, Forciea MA (2017) Noninvasive treatments for acute, subacute, and chronic low back pain: a clinical practice guideline from the American College of Physicians. Ann Intern Med 166(7):514\u2013530. https:\/\/doi.org\/10.7326\/M16-2367","journal-title":"Ann Intern Med"},{"key":"2126_CR4","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1136\/bmj.l689","volume":"364","author":"SM Rubinstein","year":"2019","unstructured":"Rubinstein SM, Zoete A, Middelkoop M et al (2019) Benefits and harms of spinal manipulative therapy for the treatment of chronic low back pain: systematic review and meta-analysis of randomised controlled trials. BMJ 364:689. https:\/\/doi.org\/10.1136\/bmj.l689","journal-title":"BMJ"},{"issue":"14","key":"2126_CR5","doi-asserted-by":"publisher","first-page":"1451","DOI":"10.1001\/jama.2017.3086","volume":"317","author":"NM Paige","year":"2017","unstructured":"Paige NM, Miake-Lye IM, Booth MS et al (2017) Association of spinal manipulative therapy with clinical benefit and harm for acute low back pain: systematic review and meta-analysis. JAMA 317(14):1451\u20131460. https:\/\/doi.org\/10.1001\/jama.2017.3086","journal-title":"JAMA"},{"issue":"2","key":"2126_CR6","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.math.2008.01.011","volume":"14","author":"TR Stanton","year":"2009","unstructured":"Stanton TR, Kawchuk GN (2009) Reliability of assisted indentation in measuring lumbar spinal stiffness. Man Ther 14(2):197\u2013205. https:\/\/doi.org\/10.1016\/j.math.2008.01.011","journal-title":"Man Ther"},{"issue":"3","key":"2126_CR7","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.jbmt.2010.03.004","volume":"14","author":"W Herzog","year":"2010","unstructured":"Herzog W (2010) The biomechanics of spinal manipulation. J Bodywork Mov Ther 14(3):280\u2013286. https:\/\/doi.org\/10.1016\/j.jbmt.2010.03.004","journal-title":"J Bodywork Mov Ther"},{"issue":"5","key":"2126_CR8","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/S1529-9430(02)00400-X","volume":"2","author":"JG Pickar","year":"2002","unstructured":"Pickar JG (2002) Neurophysiological effects of spinal manipulation. Spine J 2(5):357\u2013371. https:\/\/doi.org\/10.1016\/S1529-9430(02)00400-X","journal-title":"Spine J"},{"key":"2126_CR9","unstructured":"Triano J (2000) The mechanics of spinal manipulation. In: Herzog W. (ed.) Clinical Biomechanics of Spinal Manipulation, pp. 92\u2013190. Churchill Livingstone, ???"},{"issue":"1","key":"2126_CR10","first-page":"30","volume":"20","author":"J Gal","year":"1997","unstructured":"Gal J, Herzog W, Kawchuk G, Conway P, Zhang Y (1997) Movements of vertebrae during manipulative thrusts to unembalmed human cadavers. J Manipulative Physiol Ther 20(1):30\u201340","journal-title":"J Manipulative Physiol Ther"},{"key":"2126_CR11","unstructured":"Colloca CJ, Keller TS, Seltzer DE, Fuhr AW (2000) Mechanical impedance of the human lower thoracic and lumbar spine exposed to in vivo posterior-anterior manipulative thrusts. In: Proceedings of the 12th Conference of the European Society of Biomechanics, Dublin, Ireland, p. 171"},{"issue":"14","key":"2126_CR12","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1097\/01.BRS.0000132305.13306.D6","volume":"29","author":"CJ Colloca","year":"2004","unstructured":"Colloca CJ, Keller TS, Gunzburg R (2004) Biomechanical and neurophysiological responses to spinal manipulation in patients with lumbar disc herniations. Spine 29(14):1611\u20131618. https:\/\/doi.org\/10.1097\/01.BRS.0000132305.13306.D6","journal-title":"Spine"},{"issue":"8","key":"2126_CR13","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1067\/mmt.2002.127075","volume":"25","author":"TS Keller","year":"2002","unstructured":"Keller TS, Colloca CJ (2002) A rigid body model of the dynamic posteroanterior motion response of the human lumbar spine. J Manipulative Physiol Ther 25(8):485\u2013496. https:\/\/doi.org\/10.1067\/mmt.2002.127075","journal-title":"J Manipulative Physiol Ther"},{"issue":"3","key":"2126_CR14","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/S0268-0033(02)00003-0","volume":"17","author":"TS Keller","year":"2002","unstructured":"Keller TS, Colloca CJ, B\u00e9liveau J-G (2002) Force-deformation response of the lumbar spine: a sagittal plane model and its validation. Clin Biomech 17(3):185\u2013196. https:\/\/doi.org\/10.1016\/S0268-0033(02)00003-0","journal-title":"Clin Biomech"},{"issue":"3","key":"2126_CR15","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1088\/0143-0815\/11\/3\/003","volume":"11","author":"M Lee","year":"1990","unstructured":"Lee M, Svensson NL (1990) Measurement of stiffness during simulated spinal physiotherapy. Clin Phys Physiol Meas 11(3):201\u2013207. https:\/\/doi.org\/10.1088\/0143-0815\/11\/3\/003","journal-title":"Clin Phys Physiol Meas"},{"issue":"3","key":"2126_CR16","first-page":"157","volume":"21","author":"J Latimer","year":"1998","unstructured":"Latimer J, Lee M, Adams RD (1998) The effects of high and low loading forces on measured values of lumbar stiffness. J Manipulative Physiol Ther 21(3):157\u2013163","journal-title":"J Manipulative Physiol Ther"},{"issue":"23","key":"2126_CR17","doi-asserted-by":"publisher","first-page":"2724","DOI":"10.1097\/00007632-199712010-00004","volume":"22","author":"A Viner","year":"1997","unstructured":"Viner A, Lee M, Adams R (1997) Posteroanterior stiffness in the lumbosacral spine: the correlation between adjacent vertebral levels. Spine 22(23):2724\u20132729","journal-title":"Spine"},{"key":"2126_CR18","volume-title":"Modal Testing: Theory, Practice and Application","author":"DJ Ewins","year":"2000","unstructured":"Ewins DJ (2000) Modal Testing: Theory, Practice and Application, 2nd edn. Research Studies Press, Baldock","edition":"2"},{"issue":"6","key":"2126_CR19","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.jmpt.2007.05.004","volume":"30","author":"CJ Colloca","year":"2007","unstructured":"Colloca CJ, Gunzburg R, Freeman BJC, Szpalski M, Afifi M, Moore RJ (2007) Biomechanical quantification of pathologic manipulable spinal lesions: an in vivo ovine model of spondylolysis and intervertebral disc degeneration. J Manipulative Physiol Ther 30(6):413\u2013425. https:\/\/doi.org\/10.1016\/j.jmpt.2007.05.004","journal-title":"J Manipulative Physiol Ther"},{"key":"2126_CR20","doi-asserted-by":"publisher","first-page":"1849593","DOI":"10.3389\/fbioe.2026.1849593","volume":"14","author":"CJ Colloca","year":"2026","unstructured":"Colloca CJ, Gunzburg R, Hegazy MA, Szpalski M (2026) Mechanical transmission of impulsive instrument-assisted spinal manipulation: contact-site-dependent biomechanical coupling in the in vivo human lumbar spine. Front Bioeng Biotechnol 14:1849593. https:\/\/doi.org\/10.3389\/fbioe.2026.1849593","journal-title":"Front Bioeng Biotechnol"},{"issue":"4","key":"2126_CR21","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1093\/comjnl\/7.4.308","volume":"7","author":"JA Nelder","year":"1965","unstructured":"Nelder JA, Mead R (1965) A simplex method for function minimization. Comput J 7(4):308\u2013313. https:\/\/doi.org\/10.1093\/comjnl\/7.4.308","journal-title":"Comput J"},{"issue":"3","key":"2126_CR22","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1061\/JMCEA3.0000098","volume":"85","author":"NM Newmark","year":"1959","unstructured":"Newmark NM (1959) A method of computation for structural dynamics. J Eng Mech Div 85(3):67\u201394","journal-title":"J Eng Mech Div"},{"key":"2126_CR23","doi-asserted-by":"publisher","unstructured":"Keller TS, Spengler DM (1987) Mechanical behavior of the human lumbar spine. I. Creep analysis during static compressive loading. J Orthop Res 5(4):467\u2013478. https:\/\/doi.org\/10.1002\/jor.1100050402","DOI":"10.1002\/jor.1100050402"},{"issue":"7","key":"2126_CR24","first-page":"690","volume":"25","author":"AB Solinger","year":"2000","unstructured":"Solinger AB (2000) Oscillatory loading of the spine to detect and characterize spinal abnormalities. Spine 25(7):690\u2013696","journal-title":"Spine"},{"issue":"1","key":"2126_CR25","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1054\/math.1998.0312","volume":"3","author":"SJ Edmondston","year":"1998","unstructured":"Edmondston SJ, Allison GT, Gregg CD et al (1998) Effect of position on the posteroanterior stiffness of the lumbar spine. Man Ther 3(1):21\u201326","journal-title":"Man Ther"},{"issue":"8","key":"2126_CR26","first-page":"522","volume":"24","author":"GN Kawchuk","year":"2001","unstructured":"Kawchuk GN, Fauvel OR (2001) Sources of variation in spinal indentation testing: indentation site, examiner, and instrument. J Manipulative Physiol Ther 24(8):522\u2013531","journal-title":"J Manipulative Physiol Ther"},{"issue":"2","key":"2126_CR27","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.clinbiomech.2007.08.025","volume":"23","author":"SHM Brown","year":"2008","unstructured":"Brown SHM, Gregory DE, McGill SM (2008) Muscle force-stiffness characteristics influence joint stability. Clin Biomech 23(2):218\u2013224. https:\/\/doi.org\/10.1016\/j.clinbiomech.2007.08.025","journal-title":"Clin Biomech"},{"issue":"1","key":"2126_CR28","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/S0030-5898(20)30944-5","volume":"8","author":"MM Panjabi","year":"1977","unstructured":"Panjabi MM, Krag MH, White AA, Southwick WO (1977) Effects of preload on load-displacement curves of the lumbar spine. Orthop Clin North Am 8(1):181\u2013192","journal-title":"Orthop Clin North Am"},{"issue":"3","key":"2126_CR29","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1016\/j.clinbiomech.2005.10.006","volume":"21","author":"CJ Colloca","year":"2006","unstructured":"Colloca CJ, Keller TS, Harrison DE, Moore RJ, Gunzburg R, Harrison DD (2006) Spinal manipulation force and duration affect vertebral movement and neuromuscular responses. Clin Biomech 21(3):254\u2013262. https:\/\/doi.org\/10.1016\/j.clinbiomech.2005.10.006","journal-title":"Clin Biomech"},{"issue":"8","key":"2126_CR30","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1067\/mmt.2000.109679","volume":"23","author":"JY Maigne","year":"2000","unstructured":"Maigne JY, Guillon F (2000) Highlighting of intervertebral movements and variations of intradiskal pressure during lumbar spine manipulation: a feasibility study. J Manipulative Physiol Ther 23(8):531\u2013535","journal-title":"J Manipulative Physiol Ther"},{"key":"2126_CR31","doi-asserted-by":"publisher","unstructured":"Keller TS, Colloca CJ, Gunzburg R (2006) Neuromechanical characterization of in vivo lumbar spinal manipulation. Part I. Vertebral motion. J Manipulative Physiol Ther 29(1):14\u201325. https:\/\/doi.org\/10.1016\/j.jmpt.2005.10.003","DOI":"10.1016\/j.jmpt.2005.10.003"},{"issue":"1","key":"2126_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jmpt.2003.11.021","volume":"27","author":"CJ Colloca","year":"2004","unstructured":"Colloca CJ, Keller TS, Gunzburg R (2004) Biomechanical and neurophysiological responses to spinal manipulation in patients with lumbar disc herniations. J Manipulative Physiol Ther 27(1):1\u201315","journal-title":"J Manipulative Physiol Ther"},{"issue":"9","key":"2126_CR33","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1016\/j.jmpt.2003.08.004","volume":"26","author":"TS Keller","year":"2003","unstructured":"Keller TS, Colloca CJ (2003) Mechanical force spinal manipulation increases trunk muscle strength assessed by electromyography: a comparative clinical trial. J Manipulative Physiol Ther 26(9):568\u2013578. https:\/\/doi.org\/10.1016\/j.jmpt.2003.08.004","journal-title":"J Manipulative Physiol Ther"},{"issue":"6","key":"2126_CR34","doi-asserted-by":"publisher","first-page":"2015","DOI":"10.1007\/s10237-020-01322-7","volume":"19","author":"F M\u00f6rl","year":"2020","unstructured":"M\u00f6rl F, G\u00fcnther M, Riede JM, Hammer M, Schmitt S (2020) Loads distributed in vivo among vertebrae, muscles, spinal ligaments, and intervertebral discs in a passively flexed lumbar spine. Biomech Model Mechanobiol 19(6):2015\u20132047. https:\/\/doi.org\/10.1007\/s10237-020-01322-7","journal-title":"Biomech Model Mechanobiol"},{"key":"2126_CR35","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-023-01804-4","author":"M Hammer","year":"2024","unstructured":"Hammer M, Wenzel T, Santin G, Meszaros-Beller L, Little JP, Haasdonk B, Schmitt S (2024) A new method to design energy-conserving surrogate models for the coupled, nonlinear responses of intervertebral discs. Biomech Model Mechanobiol. https:\/\/doi.org\/10.1007\/s10237-023-01804-4","journal-title":"Biomech Model Mechanobiol"}],"container-title":["Biomechanics and Modeling in Mechanobiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-026-02126-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10237-026-02126-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-026-02126-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T07:45:42Z","timestamp":1790149542000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10237-026-02126-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":35,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["2126"],"URL":"https:\/\/doi.org\/10.1007\/s10237-026-02126-x","relation":{},"ISSN":["1617-7959","1617-7940"],"issn-type":[{"value":"1617-7959","type":"print"},{"value":"1617-7940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]},"assertion":[{"value":"29 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"C.J.C. is the developer, CEO and majority shareholder\u00a0of the company that manufactures\u00a0 the Impulse iQ Adjusting Instrument (Neuromechanical Innovations, LLC, Phoenix, AZ) used in this study. R.G. declares no conflict of interest.","order":1,"name":"Ethics","label":"Conflict of interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the institutional ethics committee (Authorization Belgium 2009). Written informed consent was obtained from all participants prior to the surgical procedure.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"110"}}