{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T05:14:26Z","timestamp":1788498866403,"version":"build-2803163510"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004913","name":"Universit\u00e0 degli Studi di Palermo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004913","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Biomech Model Mechanobiol"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>To develop a fully coupled, patient-specific fluid\u2013structure interaction (FSI) framework for quantitative assessment of post\u2013transcatheter aortic valve implantation (TAVI) hemodynamics and valve biomechanics, and to compare selected simulation-derived hemodynamic indices with post-procedural echocardiographic measurements. Patient-specific geometries were reconstructed from pre-operative computed tomography angiography in five subjects treated with SAPIEN 3 Ultra (S3) devices. Structural TAVI deployment was simulated using Abaqus\/Explicit and subsequently coupled with FlowVision for performing a two-way post-TAVI FSI analysis. Personalized boundary conditions were derived from clinical measurements, including heart rate, blood pressure, and echocardiographic flow data. Predicted peak velocity, effective orifice area (EOA), and transvalvular pressure gradients (TPG) were quantitatively compared with post-procedural echocardiography using empirical cumulative distribution functions and area-based error metrics. The FSI framework reproduced realistic leaflet kinematics and patient-specific flow patterns, highlighting marked inter-patient variability despite identical device types. Average of predicted peak systolic velocity (2.66\u2009\u00b1\u20090.59\u00a0m\/s) and TPG (22\u2009\u00b1\u200910.7\u00a0mmHg) showed good agreement with echocardiographic measurements as the area metric was below 10% for both peak TPG and velocity. Larger discrepancies were observed for EOA due to patient variability and reliability of echocardiographic measurements. The model additionally quantified biomechanical and hemodynamic parameters, including leaflet stress, time-averaged wall shear stress (TAWSS), and blood residence time (BRT). The proposed fully coupled FSI framework enables patient-specific analysis of post-TAVI hemodynamics and valve mechanics for S3 balloon-expandable intra-annular system. The preliminary comparison with echocardiographic measurements showed good agreement for peak velocity and peak TPG, while larger EOA discrepancies highlight the need for further clinical benchmarking using larger cohorts and more direct measurement modalities.<\/jats:p>","DOI":"10.1007\/s10237-026-02130-1","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T04:22:48Z","timestamp":1788495768000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Fully coupled patient-specific fluid\u2013structure interaction modeling of post-TAVI hemodynamics compared with echocardiographic measurements"],"prefix":"10.1007","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6567-061X","authenticated-orcid":false,"given":"Chiara","family":"Catalano","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deniz","family":"Ozturk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Bastron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandra","family":"Zerillo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Cannata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6049-8961","authenticated-orcid":false,"given":"Caterina","family":"Gandolfo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4841-2560","authenticated-orcid":false,"given":"Salvatore","family":"Pasta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"issue":"7","key":"2130_CR1","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1080\/10255842.2015.1058928","volume":"19","author":"J Bailey","year":"2016","unstructured":"Bailey J, Curzen N, Bressloff NW (2016) Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root. Comput Methods Biomech Biomed Eng 19(7):733\u2013744. https:\/\/doi.org\/10.1080\/10255842.2015.1058928","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"5","key":"2130_CR2","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/j.jacc.2018.10.078","volume":"73","author":"DJ Blackman","year":"2019","unstructured":"Blackman DJ, Saraf S, MacCarthy PA, Myat A, Anderson SG, Malkin CJ et al (2019) Long-term durability of transcatheter aortic valve prostheses. J Am Coll Cardiol 73(5):537\u2013545. https:\/\/doi.org\/10.1016\/j.jacc.2018.10.078","journal-title":"J Am Coll Cardiol"},{"key":"2130_CR3","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.jbiomech.2018.02.017","volume":"71","author":"GM Bosi","year":"2018","unstructured":"Bosi GM, Capelli C, Cheang MH, Delahunty N, Mullen M, Taylor AM et al (2018) Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations. J Biomech 71:236\u2013244","journal-title":"J Biomech"},{"issue":"1","key":"2130_CR4","doi-asserted-by":"publisher","first-page":"59","DOI":"10.21037\/cdt.2019.09.12","volume":"10","author":"J Braghiroli","year":"2020","unstructured":"Braghiroli J, Kapoor K, Thielhelm TP, Ferreira T, Cohen MG (2020) Transcatheter aortic valve replacement in low risk patients: a review of PARTNER 3 and Evolut low risk trials. Cardiovasc Diagn Ther 10(1):59\u201371. https:\/\/doi.org\/10.21037\/cdt.2019.09.12","journal-title":"Cardiovasc Diagn Ther"},{"issue":"1","key":"2130_CR5","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s10439-022-03047-3","volume":"51","author":"JA Brown","year":"2023","unstructured":"Brown JA, Lee JH, Smith MA, Wells DR, Barrett A, Puelz C et al (2023) Patient-specific immersed finite element-difference model of transcatheter aortic valve replacement. Ann Biomed Eng 51(1):103\u2013116. https:\/\/doi.org\/10.1007\/s10439-022-03047-3","journal-title":"Ann Biomed Eng"},{"issue":"1","key":"2130_CR6","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1007\/s13239-023-00699-7","volume":"15","author":"C Catalano","year":"2024","unstructured":"Catalano C, Turgut T, Zahalka O, G\u00f6tzen N, Cannata S, Gentile G et al (2024) On the material constitutive behavior of the aortic root in patients with transcatheter aortic valve implantation. Cardiovasc Eng Technol 15(1):95\u2013109","journal-title":"Cardiovasc Eng Technol"},{"issue":"4","key":"2130_CR7","doi-asserted-by":"publisher","first-page":"046101","DOI":"10.1063\/5.0280958","volume":"9","author":"C Catalano","year":"2025","unstructured":"Catalano C, Scuoppo R, Turgut T, Bouwman V, Gotzen N, Cannata S et al (2025) Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation. I. A population-based validation of patient-specific modeling. APL Bioeng. 9(4):046101. https:\/\/doi.org\/10.1063\/5.0280958","journal-title":"APL Bioeng."},{"issue":"3","key":"2130_CR8","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1093\/icvts\/ivt245","volume":"17","author":"G D'Ancona","year":"2013","unstructured":"D\u2019Ancona G, Amaducci A, Rinaudo A, Pasta S, Follis F, Pilato M et al (2013) Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis. Interact Cardiovasc Thorac Surg 17(3):576\u2013578. https:\/\/doi.org\/10.1093\/icvts\/ivt245","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"2","key":"2130_CR9","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1111\/j.1440-1681.2008.05099.x","volume":"36","author":"LP Dasi","year":"2009","unstructured":"Dasi LP, Simon HA, Sucosky P, Yoganathan AP (2009) Fluid mechanics of artificial heart valves. Clin Exp Pharmacol Physiol 36(2):225\u2013237","journal-title":"Clin Exp Pharmacol Physiol"},{"issue":"6","key":"2130_CR10","doi-asserted-by":"publisher","first-page":"e3704","DOI":"10.1002\/cnm.3704","volume":"39","author":"I Fumagalli","year":"2023","unstructured":"Fumagalli I, Polidori R, Renzi F, Fusini L, Quarteroni A, Pontone G et al (2023) Fluid-structure interaction analysis of transcatheter aortic valve implantation. Int J Numer Method Biomed Eng 39(6):e3704. https:\/\/doi.org\/10.1002\/cnm.3704","journal-title":"Int J Numer Method Biomed Eng"},{"issue":"3","key":"2130_CR11","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.ces.2003.10.013","volume":"59","author":"F Ghirelli","year":"2004","unstructured":"Ghirelli F, Leckner B (2004) Transport equation for the local residence time of a fluid. Chem Eng Sci 59(3):513\u2013523. https:\/\/doi.org\/10.1016\/j.ces.2003.10.013","journal-title":"Chem Eng Sci"},{"issue":"5","key":"2130_CR12","doi-asserted-by":"publisher","first-page":"1725","DOI":"10.1007\/s10237-020-01304-9","volume":"19","author":"RP Ghosh","year":"2020","unstructured":"Ghosh RP, Marom G, Bianchi M, D\u2019souza K, Zietak W, Bluestein D (2020a) Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid\u2013structure interaction analysis. Biomech Model Mechanobiol 19(5):1725\u20131740","journal-title":"Biomech Model Mechanobiol"},{"issue":"5","key":"2130_CR13","doi-asserted-by":"publisher","first-page":"1725","DOI":"10.1007\/s10237-020-01304-9","volume":"19","author":"RP Ghosh","year":"2020","unstructured":"Ghosh RP, Marom G, Bianchi M, D\u2019Souza K, Zietak W, Bluestein D (2020b) Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis. Biomech Model Mechanobiol 19(5):1725\u20131740. https:\/\/doi.org\/10.1007\/s10237-020-01304-9","journal-title":"Biomech Model Mechanobiol"},{"key":"2130_CR14","doi-asserted-by":"publisher","first-page":"109159","DOI":"10.1016\/j.compbiomed.2024.109159","volume":"182","author":"B Grossi","year":"2024","unstructured":"Grossi B, Barati S, Ramella A, Migliavacca F, Rodriguez Matas JF, Dubini G et al (2024) Validation evidence with experimental and clinical data to establish credibility of TAVI patient-specific simulations. Comput Biol Med 182:109159. https:\/\/doi.org\/10.1016\/j.compbiomed.2024.109159","journal-title":"Comput Biol Med"},{"key":"2130_CR15","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.xjon.2022.01.017","volume":"9","author":"H Hatoum","year":"2022","unstructured":"Hatoum H, Ahn S, Lilly S, Maureira P, Crestanello J, Thourani VH et al (2022) Flow dynamics of surgical and transcatheter aortic valves: past to present. JTCVS Open 9:43\u201356","journal-title":"JTCVS Open"},{"key":"2130_CR16","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.jmbbm.2018.06.032","volume":"86","author":"HS Kandail","year":"2018","unstructured":"Kandail HS, Trivedi SD, Shaikh AC, Bajwa TK, O\u2019Hair DP, Jahangir A et al (2018) Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics. J Mech Behav Biomed Mater 86:131\u2013142","journal-title":"J Mech Behav Biomed Mater"},{"issue":"5","key":"2130_CR17","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1038\/s41569-023-00862-6","volume":"20","author":"GB Lim","year":"2023","unstructured":"Lim GB (2023) Suitability of TAVI in low-risk patients. Nat Rev Cardiol 20(5):284","journal-title":"Nat Rev Cardiol"},{"issue":"3","key":"2130_CR18","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1007\/s13239-019-00427-0","volume":"10","author":"G Luraghi","year":"2019","unstructured":"Luraghi G, Migliavacca F, Garcia-Gonzalez A, Chiastra C, Rossi A, Cao D et al (2019) On the modeling of patient-specific transcatheter aortic valve replacement: a fluid-structure interaction approach. Cardiovasc Eng Technol 10(3):437\u2013455. https:\/\/doi.org\/10.1007\/s13239-019-00427-0","journal-title":"Cardiovasc Eng Technol"},{"issue":"4","key":"2130_CR19","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1007\/s13239-016-0285-7","volume":"7","author":"W Mao","year":"2016","unstructured":"Mao W, Li K, Sun W (2016) Fluid-structure interaction study of transcatheter aortic valve dynamics using smoothed particle hydrodynamics. Cardiovasc Eng Technol 7(4):374\u2013388. https:\/\/doi.org\/10.1007\/s13239-016-0285-7","journal-title":"Cardiovasc Eng Technol"},{"issue":"12","key":"2130_CR20","doi-asserted-by":"publisher","first-page":"e3649","DOI":"10.1002\/cnm.3649","volume":"38","author":"D Oks","year":"2022","unstructured":"Oks D, Samaniego C, Houzeaux G, Butakoff C, Vazquez M (2022) Fluid-structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements. Int j Numer Method Biomed Eng. 38(12):e3649. https:\/\/doi.org\/10.1002\/cnm.3649","journal-title":"Int j Numer Method Biomed Eng."},{"issue":"3","key":"2130_CR21","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1007\/s10439-023-03419-3","volume":"52","author":"D Oks","year":"2024","unstructured":"Oks D, Reza S, V\u00e1zquez M, Houzeaux G, Kovarovic B, Samaniego C et al (2024) Effect of sinotubular junction size on TAVR leaflet thrombosis: a fluid\u2013structure interaction analysis. Ann Biomed Eng 52(3):719\u2013733","journal-title":"Ann Biomed Eng"},{"issue":"6","key":"2130_CR22","doi-asserted-by":"publisher","first-page":"3405","DOI":"10.1007\/s00366-024-01973-5","volume":"40","author":"XG Pan","year":"2024","unstructured":"Pan XG, Corpuz AM, Rajanna MR, Johnson EL (2024) Parameterization, algorithmic modeling, and fluid\u2013structure interaction analysis for generative design of transcatheter aortic valves. Eng Comput 40(6):3405\u20133427","journal-title":"Eng Comput"},{"key":"2130_CR23","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-020-02138-4","author":"S Pasta","year":"2020","unstructured":"Pasta S, Cannata S, Gentile G, Di Giuseppe M, Cosentino F, Pasta F et al (2020) Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve. Med Biol Eng Comput. https:\/\/doi.org\/10.1007\/s11517-020-02138-4","journal-title":"Med Biol Eng Comput"},{"issue":"7","key":"2130_CR24","doi-asserted-by":"publisher","first-page":"91","DOI":"10.3390\/bioengineering8070091","volume":"8","author":"S Pasta","year":"2021","unstructured":"Pasta S, Cannata S, Gentile G, Agnese V, Raffa GM, Pilato M et al (2021) Transcatheter heart valve implantation in bicuspid patients with self-expanding device. Bioengineering (Basel) 8(7):91","journal-title":"Bioengineering (Basel)"},{"key":"2130_CR25","doi-asserted-by":"publisher","first-page":"750656","DOI":"10.3389\/fbioe.2021.750656","volume":"9","author":"MY Salmasi","year":"2021","unstructured":"Salmasi MY, Pirola S, Sasidharan S, Fisichella SM, Redaelli A, Jarral OA et al (2021) High wall shear stress can predict wall degradation in ascending aortic aneurysms: an integrated biomechanics study. Front Bioeng Biotech 9:750656","journal-title":"Front Bioeng Biotech"},{"key":"2130_CR26","doi-asserted-by":"publisher","first-page":"112357","DOI":"10.1016\/j.jbiomech.2024.112357","volume":"176","author":"R Scuoppo","year":"2024","unstructured":"Scuoppo R, Cannata S, Gandolfo C, Bellavia D, Pasta S (2024) On the accuracy of the segmentation process and transcatheter heart valve dimensions in TAVI patients. J Biomech 176:112357","journal-title":"J Biomech"},{"issue":"4","key":"2130_CR27","doi-asserted-by":"publisher","first-page":"046102","DOI":"10.1063\/5.0280959","volume":"9","author":"R Scuoppo","year":"2025","unstructured":"Scuoppo R, Catalano C, Turgut T, Gotzen N, Cannata S, Gentile G et al (2025) Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation-Part 2: uncertainty quantification and sensitivity analysis. APL Bioeng 9(4):046102. https:\/\/doi.org\/10.1063\/5.0280959","journal-title":"APL Bioeng"},{"key":"2130_CR28","doi-asserted-by":"publisher","DOI":"10.1016\/j.hjc.2024.10.006","author":"C Vasileios","year":"2024","unstructured":"Vasileios C, Ilias K, George F, Eutyxia S, Euaggelos L, Antonios M et al (2024) Vascular complications in TAVI procedures: assessment, management, and outcomes-a retrospective study. Hellenic J Cardiol. https:\/\/doi.org\/10.1016\/j.hjc.2024.10.006","journal-title":"Hellenic J Cardiol"},{"key":"2130_CR29","doi-asserted-by":"publisher","first-page":"105092","DOI":"10.1016\/j.jmbbm.2022.105092","volume":"127","author":"BJ Vogl","year":"2022","unstructured":"Vogl BJ, El Shaer A, Crestanello JA, Alkhouli M, Hatoum H (2022) Flow dynamics in the sinus and downstream of third and fourth generation balloon expandable transcatheter aortic valves. J Mech Behav Biomed Mater 127:105092","journal-title":"J Mech Behav Biomed Mater"},{"key":"2130_CR30","doi-asserted-by":"publisher","first-page":"112556","DOI":"10.1016\/j.cma.2019.07.025","volume":"357","author":"MCH Wu","year":"2019","unstructured":"Wu MCH, Muchowski HM, Johnson EL, Rajanna MR, Hsu MC (2019) Immersogeometric fluid-structure interaction modeling and simulation of transcatheter aortic valve replacement. Comput Methods Appl Mech Eng 357:112556. https:\/\/doi.org\/10.1016\/j.cma.2019.07.025","journal-title":"Comput Methods Appl Mech Eng"}],"container-title":["Biomechanics and Modeling in Mechanobiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-026-02130-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10237-026-02130-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10237-026-02130-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T04:22:49Z","timestamp":1788495769000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10237-026-02130-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["2130"],"URL":"https:\/\/doi.org\/10.1007\/s10237-026-02130-1","relation":{},"ISSN":["1617-7959","1617-7940"],"issn-type":[{"value":"1617-7959","type":"print"},{"value":"1617-7940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]},"assertion":[{"value":"25 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the IRCCS ISMETT Ethics Committee (approval no. IRRB04\/04). All participants provided written informed consent prior to enrolment in the study.","order":2,"name":"Ethics","label":"Ethical approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors were fully involved in the study and preparation of the manuscript which contribution originality can be confirmed by members of ISMETT and the University of Palermo. All authors approve the submission.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"98"}}