{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T20:58:18Z","timestamp":1788641898527,"version":"build-2803163510"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,4,15]],"date-time":"2016-04-15T00:00:00Z","timestamp":1460678400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Odontology"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1007\/s10266-016-0242-9","type":"journal-article","created":{"date-parts":[[2016,4,15]],"date-time":"2016-04-15T02:23:29Z","timestamp":1460687009000},"page":"62-67","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Fracture resistance of three-unit zirconia fixed partial denture with modified framework"],"prefix":"10.1007","volume":"105","author":[{"given":"Arthur","family":"Partiyan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Essam","family":"Osman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad M.","family":"Rayyan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moustafa","family":"Aboushelib","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Ibrahim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryo","family":"Jimbo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,4,15]]},"reference":[{"key":"242_CR1","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/j.1600-0501.2009.01717.x","volume":"20","author":"A Zembic","year":"2009","unstructured":"Zembic A, Sailer I, Jung RE, H\u00e4mmerle CHF. Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions: 3-year results. Clin Oral Implants Res. 2009;20:802\u20138.","journal-title":"Clin Oral Implants Res"},{"key":"242_CR2","first-page":"383","volume":"20","author":"I Sailer","year":"2007","unstructured":"Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20:383\u20138.","journal-title":"Int J Prosthodont"},{"key":"242_CR3","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1016\/j.dental.2011.09.006","volume":"27","author":"O Moldovan","year":"2011","unstructured":"Moldovan O, Luthardt RG, Corcodel N, Rudolph H. Three-dimensional fit of CAD\/CAM-made zirconia copings. Dent Mater. 2011;27:1273\u20138.","journal-title":"Dent Mater"},{"key":"242_CR4","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s00784-008-0224-6","volume":"13","author":"F Beuer","year":"2009","unstructured":"Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Invest. 2009;13:343\u20139.","journal-title":"Clin Oral Invest"},{"key":"242_CR5","first-page":"641","volume":"37","author":"B Al-Amleh","year":"2010","unstructured":"Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil. 2010;37:641\u201352.","journal-title":"J Oral Rehabil"},{"key":"242_CR6","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.jdent.2007.07.008","volume":"35","author":"PF Manicone","year":"2007","unstructured":"Manicone PF, Iommetti PR, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent. 2007;35:819\u201326.","journal-title":"J Dent"},{"key":"242_CR7","first-page":"217","volume":"21","author":"J Tinschert","year":"2008","unstructured":"Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont. 2008;21:217\u201322.","journal-title":"Int J Prosthodont"},{"key":"242_CR8","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.jmbbm.2010.07.004","volume":"3","author":"U Lohbauer","year":"2010","unstructured":"Lohbauer U, Amberger G, Quinn GD, Scherrer SS. Fractographic analysis of a dental zirconia framework: a case study on design issues. J Mech Behav Biomed Mater. 2010;3:623\u20139.","journal-title":"J Mech Behav Biomed Mater"},{"key":"242_CR9","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1590\/S1678-77572007000500005","volume":"15","author":"AB Motta","year":"2007","unstructured":"Motta AB, Pereira LC, Cunha ARCCd. All-ceramic and porcelain-fused-to-metal fixed partial dentures: a comparative study by 2D finite element analyses. J Appl Oral Sci. 2007;15:399\u2013405.","journal-title":"J Appl Oral Sci"},{"key":"242_CR10","first-page":"179","volume":"37","author":"DJ Mahmood","year":"2013","unstructured":"Mahmood DJ, Linderoth EH, Von Steyern PV, Wennerberg A. Fracture strength of all-ceramic (Y-TZP) three- and four-unit fixed dental prostheses with different connector design and production history. Swed Dent J. 2013;37:179\u201387.","journal-title":"Swed Dent J"},{"key":"242_CR11","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1067\/mpr.2002.123850","volume":"87","author":"WS Oh","year":"2002","unstructured":"Oh WS, Anusavice KJ. Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. J Prosthet Dent. 2002;87:536\u201342.","journal-title":"J Prosthet Dent"},{"key":"242_CR12","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1177\/154405910608500314","volume":"85","author":"B Taskonak","year":"2006","unstructured":"Taskonak B, Mecholsky JJ, Anusavice KJ. Fracture surface analysis of clinically failed fixed partial dentures. J Dent Res. 2006;85:277\u201381.","journal-title":"J Dent Res"},{"key":"242_CR13","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.dental.2011.11.009","volume":"28","author":"AK Mainjot","year":"2012","unstructured":"Mainjot AK, Schajer GS, Vanheusden AJ, Sadoun MJ. Influence of zirconia framework thickness on residual stress profile in veneering ceramic: measurement by hole-drilling. Dent Mater. 2012;28:378\u201384.","journal-title":"Dent Mater"},{"key":"242_CR14","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.dental.2007.06.030","volume":"24","author":"H Wang","year":"2008","unstructured":"Wang H, Aboushelib MN, Feilzer AJ. Strength influencing variables on CAD\/CAM zirconia frameworks. Dent Mater. 2008;24:633\u20138.","journal-title":"Dent Mater"},{"key":"242_CR15","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1111\/j.1600-0722.2007.00429.x","volume":"115","author":"P Kohorst","year":"2007","unstructured":"Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci. 2007;115:161\u20136.","journal-title":"Eur J Oral Sci"},{"key":"242_CR16","doi-asserted-by":"crossref","first-page":"586","DOI":"10.2341\/08-076-L","volume":"34","author":"M Comlekoglu","year":"2009","unstructured":"Comlekoglu M, Dundar M, \u00d6zcan M, Gungor M, Gokce B, Artunc C. Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns. Oper Dent. 2009;34:586\u201392.","journal-title":"Oper Dent"},{"key":"242_CR17","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1111\/j.1532-849X.2011.00787.x","volume":"21","author":"MN Aboushelib","year":"2012","unstructured":"Aboushelib MN. Fatigue and fracture resistance of zirconia crowns prepared with different finish line designs. J Prosthodont. 2012;21:22\u20137.","journal-title":"J Prosthodont"},{"key":"242_CR18","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1002\/jbm.b.31782","volume":"96","author":"W Kou","year":"2011","unstructured":"Kou W, Li D, Qiao J, Chen L, Ding Y, Sjogren G. A 3D numerical simulation of stress distribution and fracture process in a zirconia-based FPD framework. J Biomed Mater Res B Appl Biomater. 2011;96:376\u201385.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"242_CR19","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.dental.2004.07.013","volume":"21","author":"A Sundh","year":"2005","unstructured":"Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater. 2005;21:476\u201382.","journal-title":"Dent Mater"},{"key":"242_CR20","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.dental.2005.11.006","volume":"22","author":"A Sundh","year":"2006","unstructured":"Sundh A, Sjogren G. Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. Dent Mater. 2006;22:778\u201384.","journal-title":"Dent Mater"},{"key":"242_CR21","first-page":"231","volume":"14","author":"J Tinschert","year":"2001","unstructured":"Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001;14:231\u20138.","journal-title":"Int J Prosthodont"},{"key":"242_CR22","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/j.dental.2007.08.001","volume":"24","author":"B Taskonak","year":"2008","unstructured":"Taskonak B, Griggs JA, Mecholsky JJ Jr, Yan JH. Analysis of subcritical crack growth in dental ceramics using fracture mechanics and fractography. Dent Mater. 2008;24:700\u20137.","journal-title":"Dent Mater"},{"key":"242_CR23","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1111\/j.1365-2842.2004.01284.x","volume":"31","author":"A Sundh","year":"2004","unstructured":"Sundh A, Sjogren G. A comparison of fracture strength of yttrium-oxide- partially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil. 2004;31:682\u20138.","journal-title":"J Oral Rehabil"}],"container-title":["Odontology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-016-0242-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10266-016-0242-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-016-0242-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-016-0242-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T16:40:44Z","timestamp":1559148044000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10266-016-0242-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4,15]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["242"],"URL":"https:\/\/doi.org\/10.1007\/s10266-016-0242-9","relation":{},"ISSN":["1618-1247","1618-1255"],"issn-type":[{"value":"1618-1247","type":"print"},{"value":"1618-1255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,4,15]]}}}