{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T08:22:00Z","timestamp":1769070120883,"version":"3.49.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,9,11]],"date-time":"2019-09-11T00:00:00Z","timestamp":1568160000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,9,11]],"date-time":"2019-09-11T00:00:00Z","timestamp":1568160000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Odontology"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s10266-019-00453-3","type":"journal-article","created":{"date-parts":[[2019,9,11]],"date-time":"2019-09-11T10:02:35Z","timestamp":1568196155000},"page":"194-201","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments"],"prefix":"10.1007","volume":"108","author":[{"given":"Wooyoung","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soram","family":"Oh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gil-Joo","family":"Ryu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tae-Hwan","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Jae","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong-Hyung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin-Na","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kee-Yeon","family":"Kum","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seok Woo","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4672-3381","authenticated-orcid":false,"given":"Ji-Hyun","family":"Jang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,9,11]]},"reference":[{"key":"453_CR1","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1111\/iej.12924","volume":"51","author":"J Zupanc","year":"2018","unstructured":"Zupanc J, Vahdat-Pajouh N, Sch\u00e4fer E. New thermomechanically treated NiTi alloys\u2014a review. Int Endod J. 2018;51:1088\u2013103.","journal-title":"Int Endod J"},{"key":"453_CR2","doi-asserted-by":"publisher","first-page":"2407","DOI":"10.1016\/0956-7151(94)90319-0","volume":"42","author":"PG McCormick","year":"1994","unstructured":"McCormick PG, Liu Y. Thermodynamic analysis of the martensitic transformation in NiTi-II. Effect of transformation cycling. Acta Metall Mater. 1994;42:2407\u201313.","journal-title":"Acta Metall Mater"},{"key":"453_CR3","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.msea.2005.05.102","volume":"405","author":"CP Frick","year":"2005","unstructured":"Frick CP, Ortega AM, Tyber J, Maksound AEM, Maier HJ, Liu Y, et al. Thermal processing of polycrystalline NiTi shape memory alloys. Mater Sci Eng A. 2005;405:34\u201349.","journal-title":"Mater Sci Eng A"},{"key":"453_CR4","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.joen.2012.11.028","volume":"39","author":"JH Ha","year":"2013","unstructured":"Ha JH, Kim SK, Cohenca N, Kim HC. Effect of R-phase heat treatment on torsional resistance and cyclic fatigue fracture. J Endod. 2013;39:389\u201393.","journal-title":"J Endod"},{"key":"453_CR5","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.joen.2015.10.004","volume":"42","author":"E Pedulla","year":"2016","unstructured":"Pedulla E, Lo Savio F, Boninelli S, Plotino G, Grande NM, La Rosa G, et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42:156\u20139.","journal-title":"J Endod"},{"key":"453_CR6","doi-asserted-by":"publisher","first-page":"1840","DOI":"10.1016\/j.joen.2016.07.015","volume":"42","author":"ME Kaval","year":"2016","unstructured":"Kaval ME, Capar ID, Ertas H. Evaluation of the cyclic fatigue and torsional resistance of novel nickel-titanium rotary files with various alloy properties. J Endod. 2016;42:1840\u20133.","journal-title":"J Endod."},{"key":"453_CR7","doi-asserted-by":"publisher","first-page":"1872","DOI":"10.1016\/j.joen.2017.05.025","volume":"43","author":"HJ Goo","year":"2017","unstructured":"Goo HJ, Kwak SW, Ha JH, Pedulla E, Kim HC. Mechanical properties of various heat-treated nickel-titanium rotary instruments. J Endod. 2017;43:1872\u20137.","journal-title":"J Endod."},{"key":"453_CR8","doi-asserted-by":"publisher","first-page":"224","DOI":"10.5395\/rde.2017.42.3.224","volume":"42","author":"T \u00d6zy\u00fcrek","year":"2017","unstructured":"\u00d6zy\u00fcrek T, Keskin NB, Furuncuoglu F, Inan U. Comparison of cyclic fatigue life of nickel-titanium files: an examination using high-speed camera. Restor Dent Endod. 2017;42:224\u201331.","journal-title":"Restor Dent Endod."},{"key":"453_CR9","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1111\/iej.12550","volume":"49","author":"D Zhao","year":"2016","unstructured":"Zhao D, Shen Y, Peng B, Haapasalo M. Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments. Int Endod J. 2016;49:990\u20135.","journal-title":"Int Endod J"},{"key":"453_CR10","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.dental.2007.05.003","volume":"24","author":"DK Pun","year":"2008","unstructured":"Pun DK, Berzins DW. Corrosion behavior of shape memory, superelastic, and non superelastic nickel-titanium-based orthodontic wires at various temperatures. Dent Mater. 2008;24:221\u20137.","journal-title":"Dent Mater"},{"key":"453_CR11","doi-asserted-by":"publisher","first-page":"218","DOI":"10.4103\/0972-0707.157256","volume":"18","author":"AS Nair","year":"2015","unstructured":"Nair AS, Tilakchand M, Naik BD. The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: an in vitro atomic force microscopy investigation. J Conserv Dent. 2015;18:218\u201322.","journal-title":"J Conserv Dent."},{"key":"453_CR12","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1111\/j.1365-2591.2012.02088.x","volume":"45","author":"G Spagnuolo","year":"2012","unstructured":"Spagnuolo G, Ametrano G, D\u2019Ant\u00f2 V, Rengo C, Simeone M, Riccitiello F, et al. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments. Int Endod J. 2012;45:1148\u201355.","journal-title":"Int Endod J"},{"key":"453_CR13","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.joen.2011.10.017","volume":"38","author":"G Plotino","year":"2012","unstructured":"Plotino G, Costanzo A, Grande NM, Petrovic R, Testarelli L, Gambarini G. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. J Endod. 2012;38:222\u20135.","journal-title":"J Endod."},{"key":"453_CR14","doi-asserted-by":"publisher","first-page":"301","DOI":"10.5395\/rde.2017.42.4.301","volume":"42","author":"T \u00d6zy\u00fcrek","year":"2017","unstructured":"\u00d6zy\u00fcrek T, Yilmaz K, Uslu G. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments. Restor Dent Endod. 2017;42:301\u20138.","journal-title":"Restor Dent Endod."},{"key":"453_CR15","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.joen.2010.09.011","volume":"37","author":"PB Hilfer","year":"2011","unstructured":"Hilfer PB, Bergeron BE, Mayerchak MJ, Roberts HW, Jeansonne BG. Multiple autoclave cycle effects on cyclic fatigue of nickel-titanium rotary files produced by new manufacturing methods. J Endod. 2011;37:72\u20134.","journal-title":"J Endod."},{"key":"453_CR16","doi-asserted-by":"publisher","first-page":"4528601","DOI":"10.1155\/2017\/4528601","volume":"2017","author":"KS Shim","year":"2017","unstructured":"Shim KS, Oh S, Kum K, Kim YC, Jee KK, Chang SW. Mechanical and mtallurgical properties of various nickel-titanium rotary instruments. Biomed Res Int. 2017;2017:4528601.","journal-title":"Biomed Res Int"},{"key":"453_CR17","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1016\/j.joen.2015.01.023","volume":"41","author":"O Higuera","year":"2015","unstructured":"Higuera O, Plotino G, Tocci L, Carrillo G, Gambarini G, Jaramillo DE. Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals. J Endod. 2015;41:913\u20135.","journal-title":"J Endod."},{"key":"453_CR18","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1016\/j.joen.2011.07.008","volume":"37","author":"RB Casper","year":"2011","unstructured":"Casper RB, Roberts HW, Roberts MD, Himel VT, Bergeron BE. Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems. J Endod. 2011;37:1572\u20135.","journal-title":"J Endod."},{"key":"453_CR19","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1111\/j.1365-2591.2011.01958.x","volume":"45","author":"JB King","year":"2012","unstructured":"King JB, Roberts HW, Bergeron BE, Mayerchak MJ. The effect of autoclaving on torsional moment of two nickel-titanium endodontic files. Int Endod J. 2012;45:156\u201361.","journal-title":"Int Endod J"},{"key":"453_CR20","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1590\/1679-775720130083","volume":"21","author":"\u00dcK Bulem","year":"2013","unstructured":"Bulem \u00dcK, Kececi AD, Guldas HE. Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and\/or sterilization. J Appl Oral Sci. 2013;21:505\u201310.","journal-title":"J Appl Oral Sci."},{"key":"453_CR21","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1016\/j.joen.2017.11.022","volume":"44","author":"A Arias","year":"2018","unstructured":"Arias A, Macorra JC, Govindjee S, Peters OA. Correlation between temperature-dependent fatigue resistance and differential scanning calorimetry analysis for 2 contemporary rotary instruments. J Endod. 2018;44:630\u20134.","journal-title":"J Endod."},{"key":"453_CR22","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.joen.2016.10.014","volume":"43","author":"G Plotino","year":"2017","unstructured":"Plotino G, Grande NM, Mercad\u00e9 Bellido M, Testarelli L, Gambarini G. Influence of temperature on cyclic fatigue resistance of ProTaper Gold and ProTaper Universal rotary files. J Endod. 2017;43:200\u20132.","journal-title":"J Endod."},{"key":"453_CR23","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1046\/j.1365-2591.2000.00339.x","volume":"33","author":"SA Thompson","year":"2000","unstructured":"Thompson SA. An overview of nickel-titanium alloys used in dentistry. Int Endod J. 2000;33:297\u2013310.","journal-title":"Int Endod J"},{"key":"453_CR24","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1111\/iej.12620","volume":"50","author":"F Iacono","year":"2017","unstructured":"Iacono F, Pirani C, Generali L, Bolelli G, Sassatelli P, Lusvarghi L, et al. Structural analysis of HyFlex EDM instruments. Int Endod J. 2017;50:303\u201313.","journal-title":"Int Endod J"},{"key":"453_CR25","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1016\/j.joen.2013.04.004","volume":"39","author":"Y Shen","year":"2013","unstructured":"Shen Y, Zhou HM, Wang Z, Campbell L, Zheng YF, Haapasalo M. Phase transformation behavior and mechanical properties of thermomechanically treated K3XF nickel-titanium instruments. J Endod. 2013;39:919\u201323.","journal-title":"J Endod."},{"key":"453_CR26","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1016\/j.joen.2015.02.030","volume":"41","author":"A Hieawy","year":"2015","unstructured":"Hieawy A, Haapasalo M, Zhou H, Wang Z-J, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper universal instruments. J Endod. 2015;41:1134\u20138.","journal-title":"J Endod."},{"key":"453_CR27","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/S0099-2399(97)80250-6","volume":"23","author":"JP Pruett","year":"1997","unstructured":"Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997;23:77\u201385.","journal-title":"J Endod."},{"key":"453_CR28","doi-asserted-by":"publisher","first-page":"2975","DOI":"10.1007\/s00784-018-2382-5","volume":"22","author":"K Yilmaz","year":"2018","unstructured":"Yilmaz K, Uslu G, \u00d6zy\u00fcrek T. Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study. Clin Oral Investig. 2018;22:2975\u201380.","journal-title":"Clin Oral Investig."},{"key":"453_CR29","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1016\/j.joen.2012.04.022","volume":"38","author":"RC Wycoff","year":"2012","unstructured":"Wycoff RC, Berzins DW. An in vitro comparison of torsional stress properties of three different rotary nickel-titanium files with a similar cross-sectional design. J Endod. 2012;38:1118\u201320.","journal-title":"J Endod."},{"key":"453_CR30","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1016\/j.joen.2008.05.007","volume":"34","author":"G Gambarini","year":"2008","unstructured":"Gambarini G, Grande NM, Plotino G, Somma F, Garala M, De Luca M, et al. Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods. J Endod. 2008;34:1003\u20135.","journal-title":"J Endod."},{"key":"453_CR31","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1016\/j.joen.2010.11.028","volume":"37","author":"J Yum","year":"2011","unstructured":"Yum J, Cheung GS, Park JK, Hur B, Kim HC. Torsional strength and toughness of nickel-titanium rotary files. J Endod. 2011;37:382\u20136.","journal-title":"J Endod."}],"container-title":["Odontology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-019-00453-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10266-019-00453-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10266-019-00453-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,10]],"date-time":"2020-09-10T16:47:44Z","timestamp":1599756464000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10266-019-00453-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9,11]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["453"],"URL":"https:\/\/doi.org\/10.1007\/s10266-019-00453-3","relation":{},"ISSN":["1618-1247","1618-1255"],"issn-type":[{"value":"1618-1247","type":"print"},{"value":"1618-1255","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,9,11]]},"assertion":[{"value":"16 April 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 September 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Multiple autoclave sterilization generally did not adversely affect the cyclic and torsional fracture resistance of ProTaper Universal, K3XF, TF Adaptive, and HyFlex EDM.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Statement of clinical relevance"}}]}}